Civil And Interior Renovation Works For Setting Up Cert In Lab Dsci And Extension Of Cs Coe Located At Webel Bhavan Gr Floor, 24 Paraganas North-West Bengal

West Bengal Electronics Industry Development Corporation Limited has published Civil And Interior Renovation Works For Setting Up Cert In Lab Dsci And Extension Of Cs Coe Located At Webel Bhavan Gr Floor. Submission Date for this Tender is 08-12-2023. Interior Work Tenders in 24 Paraganas North West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

40619484
Corrigendum : Civil And Interior Renovation Works For Setting Up Cert In Lab Dsci And Extension Of Cs Coe Located At Webel Bhavan Gr Floor
Open Tender
Indian
West Bengal
24 Paraganas North
08-12-2023

Tender Details

Civil And Interior Renovation Works For Setting Up Cert In Lab Dsci And Extension Of Cs Coe Located At Webel Bhavan Gr Floor

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Nov-2023 DATE CORRIGENDUM -1 Date 01-12-2023
2 01-Dec-2023 Bid Closing Date is revised Date 08-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 76200.0 /-
Tender Value
INR 38.09 Lakhs /-

BOQ Items

Name of Work: Civil and interior renovation works for setting up CERT-in-Lab , DSCI and extension of CS COE located at Webel Bhavan Gr Floor
Sl. No. Item Description
1Full/Half Height Partition
2Supplying and erecting half height or full height partition I.e. upto soffit of the ceiling, beam, false ceiling, bulk head etc made of aluminium hollow tube (50 x 50 x 2) mm frame work for both vertical and horizontal members @ 600mm bothways linked horizontally and vertically,top runners bottom skirting end trims, corner posts both horizontal as per drawing and direction with all labour and materials. Allow for cutting chase to wall, floors and mending good damages. Partition which are to be terminated at false ceiling level, the end & intermediate vertical members are to be extended upto ceiling/beam and frames are to be fitted properly by means of approved metal (Brass) expansion fastener. (measurement for ply fixing area will be cosnidered for payment)
3Rate should include necessary hardware fittings and fixtures, adhesive, roof/height adjuster etc and arrangement shall be made to both vertical and horizontal members by cutting slots for drawing of raw power, UPS power, LAN connection, telephone etc and also making provisions for fixing of power outlets. Special cover plates, pierced for fittings of switch board should be fitted on the frame work as per drawing and direction. The rates should also include to cover the end trims by 75 mm x 25 mm (approx) Indian best quality moulded teak wood bead duly polished and malamine finish as per drawing / direction of EIC wherever applicable complete with all labour and materials.
4Partitions made with 9 mm thick phenol formaldehyde bonded BWR and borer proof plywood with IS 303 mark fitted on both sides of the frame work with groove design. All complete as per drawing and direction with all labour and materials.(Partition measurement will be single side)
5Extra over for making & Fixing of Pinup tile board made up of approved quality Fabric wrapped in polypropylene sheet encased in CRCA steel/ GI sheet/ply etc all complete as per directions of Engineer-in-Charge.
6Partitions made with glass (single glazed) each glass being 6mm clear float glass of approved make fixed to aluminium frame/wood with moulded best quality Indianteak wood beads duly polished and malamine finish of approved shade, all complete as per drawing and directions with all labour and materials.
7Extra Providing glass wool of 50mm thick having density of 48 Kg per cum. to be inserted into the pre - fabricated slot covered the glass wool by marking cloths treated with Naptha @ 0.07 Ltr.per Sq.m. of cloths for acoustic purpose. complete as per directions of Engineer-in-Charge.
8LAMINATES & VENEER
9Supplying and fixing 1.00 mm thick decorative laminate of approved quality and shade fitted over plywood (plywood measured and paid separately in the respective items) to partition wall, column encasing, furniture and for other surfaces as per the approved pattern andinstructions. The rate should include the costs of approved adhesive (Fevicol), nail, screws etc for proper fixing as per design, drawing and directioncomplete in all respects with all labour and materials.
10Supplying and fixing 1.25 mm thick premium range decorative laminate of approved quality and shade fitted over plywood (plywood measured and paid separately in the respective items) to partition wall, column encasing, furniture and for other surfaces as per the approved pattern andinstructions. The rate should include the costs of approved adhesive (Fevicol), nail, screws etc for proper fixing as per design, drawing and directioncomplete in all respects with all labour and materials. - Royal Touch brand premium quality or equivalent
11WALL PANELLING & Wall Paper
12Supplying and fixing panelling to wall, column upto soffit of ceiling, beam and bulk head made of (MIN SIZE 37.5 x 37.5 x 2) mm aluminium hollow tube frame work for both horizontal and vertical members linked horizontally & vertically, top runner, bottom skirtring, end twin corner posts, complete as per drawing and direction with all labour & materials. Allow for cutting chase to walls, floors and ceiling and mending good damages to match with the adjacent surface. Frames are to be fitted to floor/masonry/RCC surface by means of approved metal expansion fastener. The outer face of the panelling is to be finished with decorative laminate/veneer over 8/9 mm thick PF bonded BWR & borer proof plywood with IS 303 mark.(laminate/veneer shall be paid separately)
13The rate should include necessary approved quality hardware fittings and fixtures, adhesive etc required for the purpose and necessary arrangement shall be made to both vertical and horizontal members by cutting slots for drawingof raw power, UPS power, LAN connection, telephones etc and also making provision for fixing of power outlets switch etc. Special cover plates pierced for fittings of switch board should be fitted on the frame work.
14Supplying, fitting, fixing of premium quality wall paper with textured effect including jointing, adhesive all labour and material complete to the satisfaction of enginer in chge
15DOOR
16Providing, fitting and fixing in position frameless fully glazed door fixed to the lintel/AL section/glass and floor fitted with necessary SS Patch fittings with double action floor spring including providing 12 mm thick toughened float glass of special selected quality free from bubbles, holes or any surface deformation. Allow for cutting, chase to walls, lintel and floor and mending good damages. The rate shouldinclude for providing necessary approved quality locks, 900mm long SS round (32mm) handles both sides, pivot, floor spring etc complete inall respects withnecessary SS patch fittings & fixtures, as per drawing and direction with all labour and materials. -
17Providing and fixing Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Stainless steel Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Malysian
18Supplying solid flush type doors of deluxe decorative (both side Decorative Laminate) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: 35mm thick shutters (single leaf). All floor & roof
19Supplying, fitting & fixing Brass floor door stopper. Any floors. Roof & above.
20Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete75x50x2.5 mm All floor & roof.
21Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)(b) 40mm X 6mm, 200mm Length
22Supplying 6 leversCrystal Satine Mortice Lock with keys & plateincluding fitting & fixing complete. All floor & roof
23PLY
24Supplying, fitting and fixing boiling water resistant ply conforming to IS: 303-1989 bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge.[excluding the cost of supporting frame work and teak wood batten/Lipping]
2525mm
2619mm
2712mm
289 mm
296mm
306mm faxible ply
31Supplying, fitting and fixing boiling water proof block board conforming to IS:1659-1990 conforming to IS:848-1974 of approved make and brand, fitted and fixed as per design as per direction of Engineer-in-charge. [Excluding the cost of supporting frame work and teak wood batten/Lipping]. 19mm thik
32Seperator
33Providing, fitting & Fixing of 12mm thk toughened (coloured / tinted) glass separator with best quality brackets for additional privacy on workstation.The rate shall include all design, any support (if required) forEngineering, 3d view and shop drawing(cad & hard copy) including approval from client, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. complete in all respect.
34FLOORING
35Supplying , fitting & fixing Digital glazed 1st qualityCeramic tiles (Size - 600mm X 600mmor 200mm X400mm X minimum 8-10mm thick) ) infloors and dado to matchwith the existing work & 4 nos. of key stones (10 mm.) fixed with araldite atback ofeach tiles & finishing the joints with the white cement mixed withcolouring oxide if required to match the colour of tiles including roughening of concrete surface ,if necessary or bysynthetic adhesive & grout materials etc. Floor With Polymerised and epoxy grout pointing including spacer-2mm(When Tiles are laid over existing hard ready surface).Colour Decorative in any floors.
3650 mm thick interlocking designer concrete paver block M-30 grade for non-traffic zone,buiding premises,garden,parks,domestic drive as per IS: 15658-2006(over 20-30 mm medium sand bedincluding cost of sand for sand bed.Coloured Decorative
37FILM
38Providing & laying "3M FASARA" & digital artistic self adhesive frosted film of 70-80 microns on glass surface as per approved shade and design complete with all materials and labour and as per manufactures specification.
39Supplying, fitting & fixing horizontal roller blinds of approved brand (VISTA/MARVEL/MAC) including all materials & labour complete as per specification & direction of Owner/Architect.
40Supplying, fitting and fixing 100 mm Vertical Blinds with all fittings and fixtures, as per approved make and shade.
41Fittings
42Wood work in post, post plates, rafters, battens, truss members, purlins,wall panelling etc. fitted and fixed complete including the cost of bolts, nails, screw etc.). Malayasian Sal
43Supplying, Fitting and Fixing of bubble free float glass of approved make and brand conforming to IS: 2835-1987.Including all fixing materials (putty etc.)
444mm thick clear glass.
456mm thick clear glass.
46Supply & fiting of Godrej Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete.Heavy duty type
47Supplying, fitting and fixing SS lock for tables/drawers/cabinets.
48CPU Trolley ( Size:245X245X240 mm)( MS) made with CRCA steel with 40 to 50 micron seven to eight processing powder coating. It will be supported on twin wheel nylon castors of four nos.
49Key Board Tray( Size:510x350x55 mm)( MS) made with CRCA /Alluminium steel with 40 to 50 micron seven to eight processing powder coating. It will be fixed with the table with the C Bracket and rolling channel for smoth running
50Supplying, fitting and fixing 300mm powder coated MS Telescopic channel.
51Supplying, fitting and fixing 100 mm SS handle.
52Supplying, fitting and fixing 75mm SS handle.
53Supplying, fitting and fixing S/S hinge auto closure
54a. 100 mm
55b. 75 mm
56Supplying, fitting, fixing of Tower Bolt as per direction of EIC
57100mm long
58300mm long
59Supplying, fitting and fixing wire manager cap including cutting hole as required.
60Supplying, fitting and fixing up to 25mm CP Teak liping including polishing.
61Supplying, fitting and fixing up to 50mm CP Teak liping including polishing.
62Supplying, fitting and fixing 2 mm thick PVC liping.
63French polishing of approved shade to wood work including preparation of surface with all labour and materials in all floors as per direction.
64Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge.ii) For openable / Casement windows a)EPDM / weather gasket for outer frame and mullion.
65Supplying stainless steel functional hinge for casement window as per approved brand as directed by Engineer- in -charge. (Natural White)(a) 250 mm long
66Supplying Heavy Duty Aluminium Handle (EBCO Type) (Natural White)
67Supplying & fixing Epoxy Powder coated ( 50 micron) aluminium sections (2.00 mm thick) for door/ window ventilators & partition etc with aluminium extruded sections of approved make and quality including providing PVC/neoprene gasket, sealent, window handles etc with provision of single/double glazed unit complete as per the direction of Engineer.(glass shall be paid separately)
68PAINTING
69Scraping of moss, blisters etc.thoroughly from interior/exterior surface of walls necessitating the use of scraper, wire brush etc. including stagging(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge)
70Rendering the surface of walls and ceiling, beams with white cement based wall putty WATER PROOF of approved make and brand(1.5mm thick) as directed by EIC in plumb line and level including preparation of base with all labour and materials. Specific approval to be taken before execution.
71Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC. (In Ground Floor)
72(a) Two Coat
73Providing and applying 1st quality acrylic emulsion paint having low VOC of approved shade to interior walls, ceiling, beams, etc (two coat or more coats to achieve even shade) over and including a Two coat of cement primer of approved quality (as per manufacturer"s specification) including cleaning, smoothening and repairing the putty surface where ever required thoroughly, scaffolding etc complete with all labour and materials in all floors. As direction of EIC
74Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
75Painting with 1st quality synthetic enamel paint two or more coats to achieve proper even shade of approved shade and quality syntheticenamelpaint over and inclusing a coat of approved primer tosteel /wooden /other surface after preparationofsurface properly with all labour & materials inallfloors. As direction of EIC
76Steel surface
77Joinery Surface
78General Civil works
79Dismantling carefully vitrified tiles, marble, kota stone, glazed/ceramic tiles, in flooring, steps, risers, dado skirting etc laid in cement mortar including stacking serviceable materials at site as per direction and disposal of unserviceable material from work site including mending good tod amaes to match with adjacent surface complete with all labour & materials at all floors.
80Dismantling the existing false ceiling boards and its frame work and removing & stacking the same in good condition as per direction of owner/Engineer-in-Charge
81Dismantling carefully wooden walling, wooden partition including glass (full heigrt) wall,flooring of ceiling and stacking dismantled materials as directed by EIC.
82Dismantling carefully the brick work in cement mortar with cement plaster on both faces for forming openings or removing the wall from its positionincludingstacking ofserviceable materials at site as per direction and removing debries from work site including mending good to damages to match with adjacent surfaces complete with all labour and materials,scaffoldings at all floors.
83Dismantling carefully RCC work of any thickness including chase cutting/cleaning reinforcements as directed including stacking of serviceable materials if any, at site as per direction and deposingof unserviceable materials from work site including mending good the surface to match with adjacent surface complete with all labour and materials in all floors.
84Dismantling carefully all types of plain cement concrete works including chase cuting , stacking serviceable materials at site and removing rubbish as directed from the site.any thickness. Any floor
85Dismantling carefully aluminium/wooden partition and refixing the same as per drawing
86Removal of misc unused items from the working site and disposal of the same beyond the compound loadingand cleaning the site in all respect as per direction of Engineer in charge within 10km
87Removal andshiftig of unused furnitures and other materials within the compound in suitable position in other floor.
88Labour charges for removal of exesting workstation & refixing the same as per direction of EIC.
89Cutting chase upto 125 x 150 mm. and subsequent mending of damages.
90In brick wall/floor tiles/wall tiles [Cement-3.6 Kg/Mtr]
91In concrete wall [Cement-3.6 Kg/Mtr]
92Earthwork in excavation of foundation trenches or drains, in all sorts of soilincluding removing, spreading or stacking the spoils within a lead of 75 m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm
93Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm including watering and ramming etc layer by layer complete (Payment to be made on the basis of measurement of finished quantity of work). With earth obtained from excavation of foundation.
94Hire and labour charges for shuttering (any architecture Design, curved beam ) with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works.12 mm thick approved quality ply board shuttering in any concrete work. All floor
95Hire and labour charges for shuttering (any architecture Design, curved beam ) with centering and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. Steel shuttering, 9 to 12mm ply wood or 25 to 30 mm thick Hard wood plank approved quality shuttering in any concrete work. Without Stagging.
96Providing cement concrete (1:1.5:3) screeding with 6 mm down stone chips to necessary gradient at roof, top finished smooth in one operation as per direction complete with all labour and materials in all floors
9715mmthick (average) cement plaster l:6 (1 cement : 6medium sand) to uneven surface, walls (risers or set back), inside of the masonry surface, beams & column flushed with brick wall including extra thickness of mortar due toinequalities of brick work & extra cement required for plastering toR.C. surface,rakingout joints including the cost of chisellingtheundulating surface of brick masonry or chipping out R.C surface where necessarycomplete in all respects as per specification including necessary scaffolding etcwith all labour and materials to all floors.
98Brick work with 1st class bricks in cement mortar (1:4). In foundation and plinth ). In foundation and plinth.
99Brick work in half brick thick masonry wall with bricks having crushing strength not less than 50 kg/sq cm in cement mortar 1:4 with H B wire netting reinforcement of approved quality at every third layerto all floors including necessary scaffolding complete as per specification and direction with all labour and materials.
100Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(pakur variety)
101Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
102M.S. structural works with hollow sections ( square or rectangular shape) conforming to IS: 806-1957 & IS:1161-1958) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineerin- Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816- 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. For other Structural works like galleries etc.
103The rate should include painting all steel surfaces with two coats of approved synthetic enamel paints over a coat of primer.(SAIL/TATA/RINL)
104Providing and fixing precoated galvanised iron profile sheets( size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.5 mm(+0.05%) total coated thickness with zinc coating 120 grams per sqm as per IS:277, in 240mpa steel grade, 5-7 micron epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard flim of 25 microns minimum to avoid scratches during transportation and should be supplied in asingle length upto 12 metre or as desired by Engineer-in-Charge. The steel shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafter and trussesand including cutting to size and shape where ever required. Make TATA Bluescope
105Ridge works in sheeting works - Providing & Fixing pre coated galvanised steel sheet works with roofing accessories 0.50mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete: with 300mm lapping each way and 225mm end lapping
106Gutter works in sheting - Providing & Fixing pre coated galvanised steel sheet works with roofing accessories 0.50mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete to make eave gutter fitted and fixed with necessary 50mm X 6mm MS flat bar clmps bent to shape and design , bolt,nuts,clamps etc complete including cost of all materials with 300mm end lapping - for 225m wide gutter
107Carefully removing,staking the paver block & refixing the same with preparation of bed as necessary withjoints properly filled in and packed with local sand
108Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction,
109For works in foundation, basement and upto roof of ground floor upto 4 m.
110Tor Steel/Mild Steel(SAIL/TATA/RINL)
111Providing,supplying & fixing light weight weather resistant pre-finished aluminium composit panel cladding on vertical or horizental surface of the building including 4mm ACP sheet exteriar grade (Aludecor/Alstrong/Pratab Bond) complete with fasteners,sealants etc with allnecessary fitting & fixtures(including frame work)
112Filling the gap in between aluminium frame & adjacent RCC / Brick/ Stone work by providing best quality weather silicon sealant over 6mm dia backer rod of approved quality as per architectural drawings and direction of Engineer-in-Charge complete. Upto 10mm depth & width
113False ceiling
114Supplying & fixing of approved mineral fibre false ceiling system on 15 mm flange stitched suspension Silhouette (3 mm) black reveal grid system having main tee 3000 mm long x 42 mm web height x 15 mm wide tee sections. The Main runner is to be fixed with 2 mm thick pre-stretched GI wire with soffit cleat @ GI Rawl Plug inserted on the main roof to be fixed at 1200 mm c/c the last hanger at the end of each main runner should not be greater than 450 mm from the adjacent wall, the Main Runner will be at the distance of 1200 mm c/c.
115The flush fitting 1200 mm x 42 mm x 15 mm wide cross tee sections, with precision stub end is to be click fit in between the Main tee at a distance of 600 mm to make a module of 1200 mm x 600 mm. Another cross tee with precision stub end of size 600 mm x 42 mm x 15 mm is to be click fitted at 12 mm sections parallel to Main tee at 600 mm centre to make a square grid of 600 mm x 600 mm.
116All base frame material clip end shold be made of cold rolled steel components and coated with hot dip galvanized steel. It should have a capping of material coated with baked polyester paint. The perimeter trim (shadow moulding) of dimension 300 mm x 19 mm x 7 mm x 7 mm x 14 mm, white colour secured at 450 mm c/c. Silhouettee main runners and cross tee to have mitred ends and "birds mouth" notches to provide mitred cruciform junctions.
117Prime Dune Premier 99 of M/s. Armstrong / M/s. AMF or similar equivalent, pre-painted regular edged tiles 15 mm thick suitable for 600 mm x 600 mm grid to be placed on grid. Tiles should have NRC of 0.50 having light reflection of 85% and thermal conductivity K-0.05200.057 W/M degrees centigrade and weight of 3.90 kg/sq mt. The fire rating of tile should be class 0 for fire propagation and Class I for spread of flames as per BS-476 and having humidity resistance of 99% Rh.
118For AC Grills and Light Fixtures, additional members, if required, is to be provided into the grid system. The work has to be done as per the direction and supervision of Architect/Manufacturer"s representative.
119Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430/1510 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 6 mm thick High Pressure Steam Cured Non Asbestos pearl designer Fibre Cement Standard Ceiling Board (Density > 1500 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type A Category IV of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-incharge. In ground floor. a) False Ceiling (with 6mm thick Pearl Designer Fibre Cement Board and E-Grid T-2430/1510).?
120MISC Work
121Renewing worn out putty of glass panes :
122Taking out carefully from shutter existing broken glass panes, cutting the same to smaller and utilising the same, small pane including cost of fitting and fixing.
123(a) Putty and Nails
124Supplying, Fitting and Fixing of Window Stopper(vi)steel peg stay 300 mm long including fitting and fixing. as per direction of E-I-C
125Supplying, Fitting and Fixing of Window Handle(iv) Two point nose steel handle including fitting and fixing. as per direction of E-I-C
126Supply, fiting and fixing of best quality Pin-Up board (Soft board) with heavy duty AL. frame works size 2ft wide X 3 ft high with all fiting and fixtures for hanging on walls.
127Supplying and application of chemical for post Installed rebar connection by using ETA approved for seismic criteria In rebar connection, Including drilling hole to the required depth by rotary hammer drill, cleonlng with brush & jet of clean air, /filling chemical(HIT-RE 500 or equivalant)using serrated nozzle to eliminate mIxIng error and in a voldless manner IncludIng charges for all tools & plants. Application to be designed for post· Installed rebars as per ECZ / TR023 or relevant tested and accepted design guidelines and the design document to be furnished by the manufacturer. The chemical should have ETA apprOVal for seIsmIc criteria of rebar fixing whIch should be furnished by manufacturer. The installation and the setting instructions should be strIctly followed as per manufacturer"sspecl/icatlons as approved by EICprior to drlll/ng along with post· Installed rebar embedment design report. The existing concrete member should be scanned using rebar scanner to avoid hitting existing reinforcement in concrete during drilling.complete in all respect & all floor, Roof & above.
128Cost of post installed rebaring application with chemical as speclfled for 10 mm dia per cm of depth
129Cost of post installed rebaring application with chemical as speclfled for 12 mm dia per cm of depth
130Antitermite & Waterproofing treatment
131The scope of service will include Anti Termite treatment post construction against Subterranean Termite for existing building at ground floor as per below mentioned treatment procedure: Drilling to be done at internal floor wall junction at an interval of 1 feet with 12 mm diameter drill bit at a depth of 4" and injecting 4 rounds of water base chemical emulsion. Drilling to be done in wooden door and window frames and inject 4 rounds water base chemical emulsion.All mud tubes to be removed after spraying water base chemical emulsion.Infested electrical switch boxes, Junction boxes (if any) to be treated with oil base chemicals.All drilling points to be sealed with white cement after injecting chemical emulsions. Three years warranty cerificate bond to be provided.
132Applying 2 coats of Non-Toxic Acrylic Polymer modified cementitious water proofing coatingby mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer"s specification in RCC/brick wall/plaster surfaces properly to all floors as perdirectioncomplete with all labour and materials to all floors.
133Cleaning glazed tiles with acid,polishing marble including removing stains.
134Supplying of Labour as per direction of E-I-C
135Supply of Mason (for Brick Work, plaster, plaster of paris work) 1st class
136Mazdoor (Male) / Unskilled labour / Helper for fitter / carpenter / mason / painter / putty works
137Supply of Carpenter 1st class
138Supply of Painter (for Putty, paint works)
139Supply of Technician (Electrical)
140Supply of Helper (Technician)
141Signage
142Supply & installation of 18 gz stainless steel name plate & puss/pull, itching & engraving including colouringas per matter given all complete as per the stisfaction of engineer
143providing and fitting 10 mm clear acrylic, pasting on indoor latex vinyl printing fixing matarial star nut,including labour.
144Supply & fitting fixingofglass door frosted filmpasting as per approveddesign direction of engineer-in charges complete.
145Chair
146High Back Chairs :For Manger Cabins Supply, fitting and installation of Executive High Back chair with overall dimesnion of height - 1200 to1350mm, width & depth - 650 to 800mm. The seat should be made up of 10-13 mm thick hot pressed plywood and moulded PU foam, back should be made up of injection moulded glass filled nylon and the seat & back should be upholstered using Quitted Leatherette fabric. .The armrest top should be moulded from polyurethane (PU) and should be height adjustable(6+/-.5 cm) type in differenet levels. The chair should have 360 degre revolving facility, synchronized tilting mechanism,continous adjustable lumbar support, multi point tilt locking features. The chair should have Pneumatic seat height adjustment facility (6+/-.5 cm),the pedestal should be 5 prong chrome plated pedestal with twin wheel nylon castors.
147Mid Back Chairs : For Workstations, visitors,others Supply, fitting and installation of Executive Mid Back chair(Overall dimesnion: Height - 900-1100mm, width & depth - 650-800mm) The seat should be made up of 12 - 14 mm thick hot pressed plywood & moulded PU foam upholstered with fabric. The back should be made up of injection moulded glass filled nylon and upholstered with mesh fabric.The armrest top should be moulded from polyurethane (PU) and should be height adjustable type. The chair should have 360 degre revolving facility, synchronized tilting mechanism,continoous adjustable lumbar support, multi point tilt locking features. The chair should have Pneumatic seat height adjustment facility (6+/-.5 cm),the pedestal should be 5 prong chrome plated pedestal with twin wheel nylon castors.