Housing Urban and Rular Development Government Departments Closing in 0 days TDR #40616285

Tender For Supply Installation Testing And Commissioning Of Ac Machines And Water Cooler Cum Purifier For Asst. Chief Medical Officer Of Health (Acmoh) Office, Khatra.

Issued by Government Departments · khatra, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Nov 2023
0 days left
EMD
7700
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
khatra → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Supply Installation Testing And Commissioning Of Ac Machines And Water Cooler Cum Purifier For Asst. Chief Medical Officer Of Health (Acmoh) Office, Khatra.

BOQ

Name of Work:- SITC of AC machines and water cooler cum purifier for Asst. Chief Medical Officer of Health (ACMOH) Office, Khatra.
Sl. No. Item Description
1ELECTRICAL INSTALLATION WORK Supply & Delivery of single phase 230V, 50 Hz A.C. Split type room air conditioner 2.0 ton capacity fitted with rotary/ reciprocating fixed speed compressor & copper cooling coil nominal cooling capacity: 4500 (KCal / h r.), cooling capacity minimum guaranteed 4250 K.Cal/hr, Minimum room discharge Air Flow 700 Cub.m/h, EER (w/w) 2.7-2.89, Star rating: 3 - Star Rated Energy efficient, incl. Remote etc. complete with 25 Amp suitable plug top as per direction of E1C (Make Hitachi / Mitshubisi / 0 General )
2Installation of the Split type 1.5 Ton 2.0 Ton A.C machine incl cutting of wall etc incl S & F suitable sizes Copper pipe of same make for Suction & Liquied line with insulation incl. S & F drain pipe of reqd. length to comp. the instn and mending good the damages as per direction of EIC.
3S & F laying of- (i) gauge copper pipe 5/8\" 0.7 mm thick for suction (ii) copper pipe 1/4\" 0.6 mm thick for discharge (OEM make) with 9 mm thick thermal insulation foam nitrile / rubber / K Flex / Accroflex with max saddling with max 1 mtr distance both for suction & discharge pipe and mending good the holes & damages as directed by EIC.(extra length for distance of ODU & IDU exceed3mtr.)
4S & Laying 3 core 2.5 sqmm PVC insulated & unarmoured copper wire (make--Finolex/Havells/KEI) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr distance as per direction of EIC.
5S & F of flexible PVC high quality water carrying pipe of 25 mm dia/proper sizefor drainage the condensate water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC.
6Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc
7Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
8Supplying and fixingof250 V AC timers fixed on wall withflat iron frame as per directionof EIC and the Box shuldbe comprising with the following accessorise ---i) Double-door SPN MCB Distribution Board with IP-42/43 protection10 / 12way Enclosureas reqd .( Make -Legrand / L & T) –1 no ii) 230 V , 50 Hz ,16 Amp Single dial 1 x 24 Hrs.Timer ( Microrex QT31 )of quartz driven running reserve Day dial back up by nickle cadmium battery (Make - GEC / Legrand) – 1 noiii) 250 V, 50 Hz , 40 Amp DP Conctractor with (2 NOor 1 NO + 1 NC Aux. Contract ) ( Make -Legrand / L & T)– 1 no iv) 250 V,50 HZ ,40 Amp , DPMCBIsolator ( Make -Legrand/L & T)– 1 no v) Auto / Manual By pass Toggle Switcharrangement – 1 no. vi) 250 V ,Diode type neon Indicator lamp ( Make -Legrand/L & T)– 1 no vii)Bakelite base with FP bolt typestud/ Terminalblock inclS & F Neutral Bar etc with this box for termination of power .viii) The complete arrangement must be wiring by 2.5 Sq mmPVC insulated Cu wire withsuitablelengthinclsocketing /lugs etc as per requirement &direction ofEIC (Make -Legrand/L & T / Crabtree)
9S & F 240V 25A OLP - 30 Electrronic motor starter in 175mm X 100mm X 65 mm depth 16 SWG MS Box coneled in wall with bakelite top cover incl. Necy. Conncetionas per direction of EIC for AC Machines
10RO+UV Water cooler cum purifier SITC OF GREEN MODEL COOLER CUM PURIFIER WITH EXTERNAL DIAMENSIONS (WxDxH)- 640 X450 X 1350, OPERATING POWER SUPPLY-230 ± 10 % V AC, 50 HZ, RUNNING CURRENT IN AMPS (MAX)-3.2 ± 10 %,POWER IN WATTS-625 ± 10 %,WATER STORAGE TANK CAPACITY-80 LTR,CAPACITY WITH COMFORT LEVEL WATER OUTLET TEMPERATURE AT 17 DEG C-60 LPH,REFRIGENT-R134 22,COMPRESSOR MAKE- EMERSON,THERMAL INSULATION FOR STORAGE TANK-PUF,TOTAL NO. OF FAUCETS-02 (1 NORMAL+1 COLD),WITH 80 LTRS STORAGE CAPACITY, RECOMMENDD MAX WATER FLOW RATE THROUGH THE FAUCETS IN LPM-1.5,NO OF STAGES FOR FILTER CUM PURIIER-03,NO OF PURIFIER CIRCUITS-03,PURIFIER FAULT INDICATION(BUZZER),VISUAL CONTROL (LEDS),WATER FLOW SWITH,10 MINUTES UV AUTO SHUT OFF,STORGE TANK MATERIAL & BODY MATERIAL- FRONT SS 304 & REST PRE COATED STEEL,WORKING WITH -0.4 KG/CC MIN. WATER INPUT PRESSURE AND 2 KG/CC OF MAX. WATER INPUT PRESSURE, INTEGRATED WATER COOLER CUM PURIFIER WITH ENDPOINT PURIFICATION TECHNOLOGY, INCLUDING 1 YEAR WARRENTY AS PER CONDITION. MAKE EUREKA FORBES/KENT

AI Tender Summary

OUR REF NO 40616285
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 17-11-2023
Authority
Authority Name Public Works Department
Work Description Tender For Supply Installation Testing And Commissioning Of Ac Machines And Water Cooler Cum Purifier For Asst. Chief Medical Officer Of Health (Acmoh) Office, Khatra.
Basic Detail
Tender No WBPWDTE/EE/BED/NIQ_60/Q of 2023-24
Bidding Type Tender
Location
City khatra
State West Bengal
Key Dates
Publish Date 10 Nov 2023
Submission Date 17 Nov 2023
Open Date 21 Nov 2023
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 7700
Exemption Not Available
Document List
9d6970d6-dd7b-4300-88cc-37c6fb3a605c.html
2911.pdf
BOQ_1279470.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 10, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 17, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 21, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

9d6970d6-dd7b-4300-88cc-37c6fb3a605c.html

pdf

2911.pdf

xls

BOQ_1279470.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders