| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 04-12-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 11-12-2023 |
| 2 | 22-11-2023 | Corrigendum1 | BOQ | 04-12-2023 |
| Sl. No. | Item Description |
| 1 | Maintenance and servicing of 250 KVA DG set of any make by the authorised technician/ service engineer of OEM or their authorised service dealer, checking the machanical and electrical healthyness of the diesal engine and alternator, servicing of the DG set including cleaning & replacement of air filter, changing of fuel filter and lubracatingoil filter, rubber hoses, worm drive clamps, nuts & bolts, draining out unserviceable engine oil from engine and refill with new engine oil, cleaning all sludge/deposits in the oil sump and removed off the site as per schedule, minor adjustment of control parameters, greasing, tracing out the defects and replacement of defective spares, testing and commissioning including taking out the old unserviceable one to keep the DG set healthy and serviceable required at 250 running hours or six months which ever is earlier as specified and directed by Engineer-in-Charge at site.(Notes :- (a) Spare Parts , engine oil will be measured and paid separately as supply only. (b) In case, any abnormalityfound in between normal routine inspections, the service personnels must attend the service call urgently within 24 hrs.(c)Apart from these routine servicings, major repair/replacement if any as decided by Engineer-in-Charge will be measured and paid separately available within the scope of this schedule.(d)A Log Book indicating the details of all types of repairs and maintenance carried out time to time has to be recorded by the contractor\"s rep/supervisor and endorsed by JE(E/M) and AGE(E/M) . The contractor\"s rep/supervisor will monitor the serviceability of all the DG Sets and give report to JE (E/M) and AGE(E/M). This register is required to be produced at the time of claiming payment. (e) Replaced spare part shall be as per make of DG sets duly recommended by OEM. |
| 2 | All as per Srl Item No. 1.00 here-in-before but DG set of capacity 200 KVA. |
| 3 | All as per Srl Item No. 1.00 here-in-before but DG set of capacity 100 KVA to 160 KVA. |
| 4 | All as per Srl Item No. 1.00 here-in-before but DG set of capacity 40 KVA to 63 KVA. |
| 5 | All as per Srl Item No. 1.00 here-in-before but DG set of capacity 15 KVAto 30 KVA. |
| 6 | Supply onlydiesel filter element with O ring suitable for D.G. Set250 KVAcomplete all as specified and directed. |
| 7 | All as per Srl Item No. 6.00 here-in-before but DG set of capacity 200 KVA. |
| 8 | All as per Srl Item No. 6.00 here-in-before but DG set of capacity 100 KVA to 160 KVA . |
| 9 | All as per Srl Item No. 6.00 here-in-before but DG set of capacity40 KVA to 63 KVA. |
| 10 | All as per Srl Item No. 6.00 here-in-before but DG set of capacity15 KVA to 30 KVA. |
| 11 | Supply onlyoil filter element with O ring suitable for D.G. Set250 KVA complete all as specified and directed. |
| 12 | All as per Srl Item No. 11.00 here-in-before but DG set of capacity 200 KVA |
| 13 | All as per Srl Item No. 11.00 here-in-before but DG set of capacity 100 KVA to 160 KVA |
| 14 | All as per Srl Item No.11.00 here-in-before suitable for but DG set of capacity 40 KVA to 63 KVA. |
| 15 | All as per Srl Item No.11.00 here-in-before suitable for but DG set of capacity 40 KVA to 63 KVA. |
| 16 | Supply only By-pass filter element with O ring suitable for D.G. Set 250 KVAcapacity complete all as specified and directed. |
| 17 | Supply only By-pass filter element with O ring suitable for D.G. Set 200 KVA capacity complete all as specified and directed. |
| 18 | Supply only By-pass filter element with O ring suitable for D.G. Set 100 KVA to 160 KVA capacity complete all as specified and directed. |
| 19 | Supply only By-pass filter element with O ring suitable for D.G. Set40 KVA to 63 KVA capacity complete all as specified and directed. |
| 20 | Supply only By-pass filter element with O ring suitable for D.G. Set 15 KVAto 30 KVAcapacity complete all as specified and directed. |
| 21 | Supply only air filter element complete with outer and inner suitable for D.G. Set 250 KVAcapacity complete all as specified and directed. |
| 22 | Supply only air filter element complete with outer and inner suitable for D.G. Set 200 KVAcapacity complete all as specified and directed. |
| 23 | Supply only air filter element complete with outer and inner suitable for D.G. Set 100 KVA to 160 KVAcapacity complete all as specified and directed. |
| 24 | Supply only air filter element complete with outer and inner suitable for D.G. Set 40 KVA to 63 KVAcapacity complete all as specified and directed. |
| 25 | Supply only air filter element complete with outer and inner suitable for D.G. Set 15 KVA to 30 KVAcapacity complete all as specified and directed. |
| 26 | Supply only fan belt suitable for D.G. Set of capacity 250 KVA, complete all as specified and directed. |
| 27 | Supply only fan belt suitable for D.G. Set of capacity 200 KVA, complete all as specified and directed. |
| 28 | Supply only fan belt suitable for D.G. Set of capacity 100 KVA to 160 KVA, complete all as specified and directed. |
| 29 | Supply only fan belt suitable for D.G. Set of capacity 40 KVA to 63 KVA, complete all as specified and directed. |
| 30 | Supply only fan belt suitable for D.G. Set of capacity 15 KVA to 30 KVA, complete all as specified and directed. |
| 31 | Supply only rubber hose pipe set with clamps suitable for D.G. Set 250 KVA capacitycomplete all as specified and directed. |
| 32 | All as per Srl Item No. 31.00 here-in-before but DG set of capacity 200 KVA. |
| 33 | All as per Srl Item No. 31.00 here-in-before but DG set of capacity 100 KVA to 160 KVA. |
| 34 | All as per Srl Item No. 31.00 here-in-before but DG set of capacity40 KVA to 63 KVA. |
| 35 | All as per Srl Item No. 31.00 here-in-before but DG set of capacity15 KVA to 30 KVA. |
| 36 | Supply of engine oil for DG sets, complete all as specified and directed. |
| 37 | Supply and filling in replacement of Coolant for Engine, complete all as specified and directed. |
| 38 | S&F in repair for water temperature gauge including sensor and cable complete all as specified and directed. |
| 39 | Taking down the radiator of 250 KVA, DG Sets from engine, transportation to the workshop, dismantling the radiator, repairing of top and bottom tank including necessary welding / brazing & making the radiator leak proof, cleaning the complete radiator internally with chemical agent (K Clean) and outside with Kerosene oil and high pressurewater jet,filling of coolant including replacement of defective copper core, suction connection, main pipe, stud, stay, spacer, rubber hose (02 Nos) and assembling the radiator including replacement of all old rusted mild steel nuts, bolts washers & gasket sets and hose pipe asembly including transportationfrom wksp to originalwork site & fixing to the engine and testing complete. (NOTE:- Coolant for radiator will be measurd and paid separately) |
| 40 | All as per Srl Item No. 39.00 here-in-before but DG set of capacity 200KVA. |
| 41 | All as per Srl Item No. 39.00 here-in-before but DG set of capacity 100 KVA to 160 KVA. |
| 42 | All as per Srl Item No. 39.00 here-in-before but DG set of capacity 40 KVA to 63 KVA. |
| 43 | All as per Srl Item No. 39.00 here-in-before but DG set of capacity 15 KVA to 30 KVA. |
| 44 | S&F in repair for water pump of suitable capacity for D.G. Set of any capacity, complete all as specified and directed. |
| 45 | S&F in repair for fuel pipe steel braded with benzo bolts, washers etc, length 30 cm long complete all as specified and directed. |
| 46 | S&F in repair for fuel pipe steel braded with benzo bolts, washers etc, length 45/60 cm long complete all as specified and directed. |
| 47 | S&F in repair for fuellevel indicator transparent PVC pipe of suitable dia for the fuel tanks complete all as specified and directed. |
| 48 | Overhauling & Calibration of fuel injection pump from the authorised dealer including petty repairs to make the fuel injection pump functional for DG set of any capacity, complete all as specified and directed. |
| 49 | S&F in replacement for gaskets, springs including tappet setting etc for DG set of capacity upto 100 KVA, complete all as specified and directed. |
| 50 | S&F in replacement for gaskets, springs including tappet setting etc for DG set of capacity above 100 KVA and upto 250 KVA, complete all as specified and directed. |
| 51 | S&F in repair for turbo charger of suitable capacity (cortrage) complete of DG set 40 KVA to 63 KVA capacity, complete all as specified and directed. |
| 52 | S&F in repair for turbo charger of suitable capacity (cortrage) complete of DG set 100 KVA to 250 KVA capacity, complete all as specified and directed. |
| 53 | S&F for battery 12 volts 180 AH red coloured specially designed for diesel Gen Set, including battery lead set of suitable size with thimble, complete all as specified and directed . |
| 54 | S&F for battery 12 volts 120 AH red coloured specially designed for diesel Gen Set, including battery lead set of suitable size with thimble, complete all as specified and directed . |
| 55 | Supply only electrolyte of suitable specific gravity in sealed container for lead acid batteries complete all as specified and directed. |
| 56 | Taking out self starter 12 volt (Make : Lucas as per existing) from the DG Set, transportation to workshop opening/disconnecting all internal connection, cleaning the same taking out burnt coil of armeture, segrigation of serviceable parts for re-use, rewinding of armeture with existing size of super enameled copper winding wire. Reassembling the same with replacement of carbon brush, bushes, Bearings and varnishing including testing complete all as directed by Engr-in-Charge.(Note :- All work mentioned above shall be included in the unit rate) |
| 57 | All as per Srl Item No. 56 here-in-before but Self starter of capacity 24 volts of existing make. (Make : Lucas as existing) |
| 58 | Preparation of old steel painted surfaces by cleaning/rubbing/scraping of old paint from the DG set and making surfaces ready for paint to DG set, 3 phase, capacity above 15 KVA and upto 250 KVA capacity and spray painting with gun one coat of synthetic enamel paint of approved colour, including writing SM/MES No, capacity and other details with white paint all as required at site or as directed. |
| 59 | Overhauling of engine mounted alternator of capacity 12 / 24 Volts including repair/replacement of rectifier, voltage regulator, diode plate carbon brushes complete all as specified and directed. |
| 60 | S&F in repair for battery charging circuit suitable for 12 /24 V, DC in existing DG set panel board including addition/ alteration in wiring system complete with auto transformer, diodes, filter circuit, condensers, DC Ammeter, DC Volt meter with selector switches, indicating bulbs etc complete all as specified and directed. |
| 61 | S&F in replacement for digital Voltmeter 0-500 Volts 96x96 mm square, flush patternwith selector switch and CT\"s complete all as specified and directed. |
| 62 | S&F in replacement for digital Ammeter 0-500 volts 96x96 mm square, flush patternwith selector switch and CT\"s complete all as specified and directed. |
| 63 | S&F in replacement for Phase indicator LED lamp with holder in different colours i.e. Red, yellow & green complete all as specified and directed. |
| 64 | S&F in replacement for battery charging alternator 12/24 Voltsuitable for 1500 RPM DG set as per exiting complete all as specified and directed. |
| 65 | S&F in repair for automatic voltage regulator for DG set of any capacity, complete as per existing all as specified and directed. |
| 66 | M&L for PCB assembly control PCC 1301, Item Code No. 0327-1513-01 suitable for Cummins/Kirloskar Engine DG sets complete as in repair all as specified and directed. |
| 67 | M&L for control assembly, Item Code No. 0300-6014 suitable for Cummins/Kirloskar Engine DG sets complete as in repair all as specified and directed. |
| 68 | M&L for disconnecting electric connections of alternator of any capacity removing from DG set, tranporting to workshop for removing burnt out winding, cleaning internally, rewinding the same with super copper enameled winding wire of suitable gauge including insulation, varnishing, drying complete including petty repair, reassembling, transporting back to site, re-fixing in position, making electric connection and testing complete all as specified and directed.Note:Winding copper wire used for rewinding will be measured and paid saparately.Cost for transportation and all other items/Materials used for thisjob are deemed to be included in the quoted rate. |
| 69 | M&L in repair for broken door of DG set capacity form 15 KVA to 250 KVA including complete denting painting with nut bolts all as specified and directed by Engr-in-Charge. |
| 70 | S&F in repairfor Onload change over switch of sheet steel enclosure confirmingSS Enclosure, front operated 4Pole 415 V, 50 Hzof Capacity 400Amps, complete all as specified and directed. |
| 71 | S&F in repairfor Onload change over switch of sheet steel enclosure confirmingSS Enclosure, front operated 4Pole 415 V, 50 Hzof Capacity 320Amps, complete all as specified and directed. |
| 72 | S&F in repairfor Onload change over switch of sheet steel enclosure confirmingSS Enclosure, front operated 4Pole 415 V, 50 Hzof Capacity 250Amps, complete all as specified and directed. |
| 73 | S&F in repairfor Onload change over switch of sheet steel enclosure confirmingSS Enclosure, front operated 4Pole 415 V, 50 Hzof Capacity 200Amps, complete all as specified and directed. |
| 74 | S&F in repairfor Onload change over switch of sheet steel enclosure confirmingSS Enclosure, front operated 4Pole 415 V, 50 Hzof Capacity 100Amps, complete all as specified and directed. |
| 75 | Taking out unserviceable control wiring complete from voltage stabilizer capacity from 5KVA and upto 25 KVA, 3 phase 415 volts of any make for unbalanced load, providing wiring loom complete, made out of suitable size PVC insulated copper conductor cable including cables lugs, connectors, channels etc complete all as specified and directed. |
| 76 | All as per Srl Item No 75.00 here-in-before but capacity of stabilizers above 25 KVA and up to 40 KVA. |
| 77 | All as per Srl Item No 75.00 here-in-before but capacity of stabilizers above 50 KVA and up to 63 KVA. |
| 78 | All as per Srl Item No 75.00 here-in-before but capacity of stabilizers above 100 KVA and up to 250 KVA. |
| 79 | S&F in replacement for analog voltmeter of size 72 x 72 mm range 30 to 300 volts complete all as specified and directed. |
| 80 | S&F in replacement for printed control card circuit suitable for voltage stabilizers complete all as specified and directed. |
| 81 | S&F in repair for servo motor single phase AC 230 volts suitable to work with voltage stabilizer from 5 KVA to 250 KVA capacity (Make AE/Blue line/Paradise/ Vintech / Electric field/ Sheeba/ Info tech) with torque up to 5 Kg/CM complete all as specified and directed. |
| 82 | S&F in repair for indicator with bulb (red, yellow, green) 230 volts as per sample complete all as specified and directed. |
| 83 | S&F in repair for dimmer stat suitable for voltage stabilizer of any capacity upto 5 to 25 KVA of any make to match with existing system. Complete all as specified and directed. |
| 84 | All as per Srl Item No. 83 here-in-before but for capacity of motor 25 KVA to 50 KVA |
| 85 | All as per Srl Item No. 83 here-in-before but for capacity of motor 50 KVA to 100 KVA |
| 86 | All as per Srl Item No. 83 here-in-before but for capacity of motor 100 KVA to 250 KVA |
| 87 | Supply and filling in replacement of new transformer oil of dielectric strength not less than 40 KV to various voltage stabilizers, complete all as specified and directed. |
| 88 | M&L for disconnecting, draining out oil dismantling voltage stabilizer, removing coil for rewinding primary and secondary coil with super enamelled copper winding wire of size and gauge as per existing including insulation varnishing, drying and reconnection at same location and testing for capacity of 05 KVA to 250 KVA, complete all as specified and directed.Note: Winding copper wire used for rewinding will be measured and paid saparately.Cost for transportatin and all other items / materials used for this job are deemed to be included in the quoted rate. |
| 89 | M&L in repair for burnt out unserviceable coil/ winding with super enameled copper winding wire of suitable size of gauge and turns as per original winding of stabilizer / alternator including all insulating papers and material required for making of coil, complete all as specified and directed. |
| 90 | Preparation of old steel painted surfaces by cleaning/rubbing/scraping of old paint from the voltage stabilizer and making surfaces ready for paint to voltage stabilizer, 3 phase, capacity upto 05 KVAto 250 KVA capacity and spray painting with gun one coat of synthetic enamel paint of approved colour, including writing SM/MES No, capacity and other details with white paint all as required at site or as directed. |
| 91 | S&F in repair of single pointed air termination aluminium rod 12mm dia and 300mm long on the highest point of the building on porcelain nase support and making termination roof / down conductor with necessary aluminium screws/ nuts, bolts etc, complete all as specified and directed. |
| 92 | S&F in repair of test point terminal block made of gun metal or phosphorous bronze of size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head brass screw in FRP box duly locking arrangement inlcuding connecting down conductor and earth strip, complete all as specified and directed. |
| 93 | S&F in repair for earth continuity conductor of aluminium strip of size 25x3mm, fixed to wall on insulators or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situationwith necessary fixing arrangement by providing porcelain base at 60cm interval and using cadmium plated fixing screws and insulators, complete all as specified and directed. |
| 94 | M&L for earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground levelconnected to and including 25X4mm thick galvanised iron strip by means ofbolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete all as specified and directed.Note:-Earthworl, Earth strip and protection pipe upto board is included in the rate quoted. |
| 95 | M&L for earthing complete with galvanised steel earth plate electrode of size 600x600x3.15mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground levelconnected to and including 25X3mm thick galvanised copper strip by means ofbolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete all as specified and directed.Note:-earthwork, Earth strip and protection pipe upto board is included in the rate quoted. |
| 96 | S&F in repair for 40 mm bore galvanized iron GI tubing medium grade with all fittings and jointing & erecting the pipe for lightening protection at any height with flat angle support to base, completeall as specified and directed. |
| 97 | S&F in repair for 80 mm bore galvanized iron GI tubing medium grade with all fittings and jointing & erecting the pipe for lightening protection at any height with flat angle support to base, completeall as specified and directed. |
| 98 | S&F in repair of GI strip of size 25x4mm as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles, complete all as specified and directed. |
| 99 | S&F in repair of copper strip of size 20x3mm as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles, complete all as specified and directed. |
| 100 | Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth in soft loose soil for foundation, etc, or for shafts, wells, drain pipes n.exc 10 Sqm on plan and getting out, complete all as specified and directed. |
| 101 | Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick ,complete all as specified and as directed. |
| 102 | Removing excavated material ,not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting poin, complete all as specified and directed. |
| 103 | M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed.(Note: Punned thickness of sand shall be measured and paid). |
| 104 | M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat,size 230mm x 115mmx 75mm, complete all as specified and as directed. |
| 105 | S&F in repair for 50 mm bore galvanized iron GI tubing light grade with all fittings such as bends, socket, tee, elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in trenches / culvert / road etc, completeall as specified and directed. |
| 106 | Supply, laying, jointng and testing,XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands, including taking down old cable complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushoining, brick cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE). |
| 107 | Supply, laying, jointng and testing,XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 35 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands, including taking down old cable complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushoining, brick cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE). |
| 108 | Supply, laying, jointng and testing,XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sqmm 4 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands, including taking down old cable complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushoining, brick cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE). |
| 109 | Supply, laying, jointng and testing,XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 Sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands, including taking down old cable complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushoining, brick cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE). |
| 110 | Supply, laying, jointng and testing,XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 6 Sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands, including taking down old cable complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushoining, brick cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE). |
| 111 | Supply, Fixing and testing of street light control panel digital 24 Hrs type of Max load 6 KW, in an inlcuding of contactor rating 32Amp TP, MCB 40Amp TPN, three phase of IP rating IP-54 with internal wiring of panel with FRLSH cable and with in-built short-circuit protection, including removing old unserviceable panel, complete all as specified and directed. |
| 112 | Supply, Fixing and testing of street light control panel digital 24 Hrs type of Max load 6 KW, in an inlcuding of contactor rating 32Amp DP, MCB 32Amp SPN, single phase of IP rating IP-54 with internal wiring of panel with FRLSH cable and with in-built short-circuit protection, including removing old unserviceable panel, complete all as specified and directed. |
| 113 | S&F in replacement for decorative LED Bollard light with opal diffuers and aluminium reflector outdoor type LED Bollard light 8W, IP 65 lihgt including all accessories and connecting materials such as clamps, brackets, nut bolts reducer etc with base PCC 1:2:4 fixed on wall/floor and making electrical connection with copper cable complete all as specified and directed. |
| 114 | S&F LED 15 watts bush and spike light luminairewith IP-65 protection complete with all accessories duly prewired and connecting with PVC insulated, sheathered flexible copper conductor cable 3 core 0.5 sq mm of adequate length from looping box to light fitting including removing old unserviceable items complete as in repair all as specified and directed by Engineer -in-charge |
| 115 | S&F in repair for post top lantern light fitting 25 watts with cast aluminium spigot lid cover and clear acrylic cover with IP65 protection complete with all accessories including fixing arrangement on top surface of boundary wall or on pillar by providing GI pipe of suitable size and length as per site requirement and making good the distrubed portion to match with existing surface complete all as specified and directed. |
| 116 | S&F for LED street light fitting 30 watts dusk and dawn type, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 66 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fitting of any type complete all as specified and directed. |
| 117 | S&F for LED street light fitting 45 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 66 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fitting of any type complete all as specified and directed. |
| 118 | S&F for LED street light fitting 60 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 66 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fitting of any type complete all as specified and directed. |
| 119 | S&F in replacement of 70 watt LED flood light luminaire outdoor type with thermal management in multiple optics and equiped with IP-66 protection with impact and corrosion resistant complete with driver and lamp and all accessories duly prewired and including fixing arrangement such as clamps, nuts, bolts, and washers etc on poles/wall surfaces etc at any height complete all as specified and directed. |
| 120 | S&F for 170 watt LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium of IP-66 protection complete with all accessories duly prewired and including fixing arrangement on high mast poles/wall surfaces etc at any height providing clamps, nuts, bolts, and washers etc after taking down old unserviceable flood light fitting of any type complete all as specified and directed. |
| 121 | M&L for GI bracket pipe of size 25mm dia medium grade of 1.2 mtr long bent to shape hot or cold suitable for streetstreet light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket shall be fixed on wall/pole surfaces by providing suitable MS iron 25x4 mm clams 2 Nos of 25 cm long duly to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts, bolts and washers and after taking down old unserviceable GI brakcet of any type complete all as specified and directed. |
| 122 | S&F for FRP looping box of size 200x140x95 with aluminium bus bar (04 Nos) 100 Amps capacity connector and comprising oF MCB SP 6 Amps, ISI marked 240 V, \"C\" series/curves complete with including providing GI calmps, nuts bolts etc suitable for fixing on PCC pole/wall/steel tubular poles etc after taking down old unserviceable looping box of any type complete all as specified and directed. |
| 123 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion after dismantling of old unserviceable earthing with material etc. complete all as specified and directed. |
| 124 | S&F for copper conductor cable, PVC insulated, sheathed flexible, multistranded ISI marked 1100 volts grade 3 core 1.5 sqmm and including connection and testing and after taking down old unserviceable copper conductor cable complete all as specified and directed. |