Military Engineer Services-MES has published Tender For Misc Repair/Maint Of Lt Oh Line, Lt Ug Cable, Lt Panel And Security Lights Etc Of Restricted And Unrestricted Area Of Cod Under Age (Em) Of Ge (East) Jabalpur. Submission Date for this Tender is 07-12-2023. Electrical Panel Tenders in jabalpur Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40599972
Corrigendum : Tender For Misc Repair/Maint Of Lt Oh Line, Lt Ug Cable, Lt Panel And Security Lights Etc Of Restricted And Unrestricted Area Of Cod Under Age (Em) Of Ge (East) Jabalpur
Open Tender
Indian
Madhya Pradesh
jabalpur
07-12-2023

Tender Details

Misc Repair / Maint Of Lt Oh Line, Lt Ug Cable, Lt Panel And Security Lights Etc Of Restricted And Unrestricted Area Of Cod Under Age ( Em ) Of Ge ( East ) Jabalpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 72000.0 /-
Tender Value
INR 35.99 Lakhs /-

BOQ Items

Name of Work :MISC REPAIR/MAINT OF LT OH LINE, LT UG CABLE, LT PANEL AND SECURITY LIGHTS ETC OF RESTRICTED AND UNRESTRICTED AREA OFCOD UNDER AGE (E/M) OF GE (EAST) JABALPUR
Sl. No. Item Description
1M&L for painting carefully (by taking necessary shut down from respective sub station) on steel tubular poles 9 m high from (above grnd 7.5 RM) upto top of the pole, including cross arms, bracings, clamps, cable protection pipes, street light clamps & pipe (fix to poles) with two coats of 1st quality aluminium paint after preparation of surface by wire brush and painting with two coats of synthetic enamel paint, after preparation of surface with different colour code from ground level to 1.0 m high with writing Pole No. of suitable size of letters complete all as specified and directed.Note : Size of lettering and colours of paints shall be directed by Engr-in-Charge.
2M&L for painting carefully (by taking necessary shut down from respective sub-station) on LT PCCPole 9 m high from (above grnd 7.5 RM) upto top of the pole,applying two coats of cement base paint over a coat of alkalines resistant primer to surface of concrete polewith cement based paint after preparation of surfaces of poles including cross arms, bracings, clamps, cable protection pipes, street light clamps & pipe (fix to poles) with two coats of 1st quality of synthetic enamel paint, after preparation of surface with different colour code from ground level to 1.0 m high with writing Pole No. of suitable size of letters complete all as specified and directed.Note : Size of lettering and colours of paints shall be directed by Engr-in-Charge.
3Diasmantling of ACSR or AAC conductors of any size from LT poles or distrubution spancomplete all as specified and directed.
4Fixing only binding from disc/shackle/loop insulator etc and rebinding after tightening/restringingof AACSR/AAC/LT over head conductors of any size with and including 14 SWG binding wire and testing complete all as specified and directed.
5M&L for binding from disc/shackle/loop insulator etc and rebinding after tightening/restringingof AACSR/AAC/LT over head conductors of any size with and including 14 SWG binding wire and testing complete all as specified and directed.
6Dismantling ACSR conductor & GI Wire of any size from LT poles or distrubution span & removal from site complete all as specified and directed.
7Fixing only binding from disc/shackle/loop insulator etc and rebinding after tightening/restringingof Galvanised steel wire 3.15 or 4 mm diaLT over head earth wire complete all as specified and directed.
8M&L for stetching and then stengthening of over head Galvanised steel wire 3.15 or 4mm dia on existing LT poles including binding & jointing the conductorand testing complete all as specified and directed.
9M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20 x 15 cm size complete all as specified and directed.
10Dismantling/taking out of defective broken unserviceable insulators of any type and including MS spindles GI washers, nuts etc and S&F insulators pin/shockle type porcelain viterous white, brown or green insulator including on galvanised mild steel spindle, two GI washers & one GI nut, 100 mm height and 65 mm dia suitable for working pressure 1100 Volts grade complete all as specified and directed.
11S&F PVC Seperator 2 way for LT O/H electric line complete all as specified and directed.
12S&F PVC Seperator 4 way for LT O/H electric line complete all as specified and directed.
13S&F, erection steel tubular swaged poles type 410 SP-31 (9 meter long), painting with two coat of aluminium paint over one coat of red oxide primer and marking pole Nos with black sythetic enamelled paint including tarring one coat of steel surface embedded in concrete complete excluding earth work and PCC work and taking out old unserviceable LT pole complete all as specified and as directed.
14Dismantling ofLT Steel Tubular poles and setting aside for reuse within 50 metres complete all as specified and directed.Note : Excavation, RFR, Removal and PCC shall be measured and paid separately.
15Demolition of cement concrete unreinforced in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
16M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in filling & mass concrete complete all as specified and directed.
17M&L for PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in coping of pole ect including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and directed.
18M&L for PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregate as in filling in surface channels and drains etc complete all as specified and directed.
19M&L for cutting/trimming the trees branches size n.exc 80 mm dia at height of exc 3 mtrs but n.exc 12 mtrs crossing/touching/embracing the overhead lines of HT/LT and obstructing the uniform electric power supply including. Removing the same from site to a distance exc 50 m complete all as specified and directed.
20All as per srl item No 19 here-in-before but of tree branches size exc 80 mm and n.exc 150 mm dia complete all as specified and directed.
21M&L for excavation in trenches n.exc 1.5 m wide and exc 1.5 m but n.exc 3.00 m in depth, for foundation of poles/stays etc and and getting out in soft/loose soil complete all as specified and dirtected.
22M&L for excavation in trenches for laying of cables, poles and stay in any type of soil n.exc 1.5 m wide and n.exc 1.50 m deep and getting outin soft/loose soil complete all as specified and dirtected.
23M&L for returning & filling in, including spreading and leveling, watering and well ramming in layers n.exc 25 cm complete all as speicified and directed.
24M&L for removing excavated materials not exc 50 m and depositing where directed at a level n.exc 1.5 m above complete all as speicified and directed.
25M&L for unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deepbefore laying and 15 cm covering above the top edge of cable after laying complete all as speicified and directed.Note : Maesurement shall be done after puning down of sand.
26M&L for Fly Ash bricks Sub-class "B" locally available laid flat in trenches over sand cushioning for cable protection complete all as speciffied and directed.
27M&L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 32 mm dia with all fittings complete all as speicified and directed.
28M&L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 40 mm dia with all fittings complete all as speicified and directed.
29M&L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 50 mm dia with all fittings complete all as speicified and directed.
30M&L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 80 mm dia with all fittings complete all as speicified and directed.
31Taking down existing old Extg unserviceable LT UG/service cable of any description and size complete all as specified and directred.
32S& F XLPE insulated armoured and pvc sheated heavy duty electric cable with aluminium conductor 1100 Volt grade laid in tranches passing through pipes /ducts including testing complete of following cross sectional area and size.Note : Rrate is inclusive of cable gland & cable lugs.
332 Core x 10 Sqmm
344 Core x 10 Sqmm
354 Core x 16 Sqmm
364 Core x 25 Sqmm
373.5 Core x 35 Sqmm
383.5 Core x 50 Sqmm
393.5 Core x 70 Sqmm
403.5 Core x 95 Sqmm
413.5 Core x 120 Sqmm
423.5 Core x 150 Sqmm
433.5 Core x 240 Sqmm
44M&L for repair/maint of floor indoor/outdoor cubical type LT Feeder Pillar Box of various sizes including disconnecting all incoming and outgoing connection after taking necessary shut down, cleaning the carbon/rust from bus-bar, rethimbling with new lugs/thimble of existing size including and segregating the serviceable and unserviceable items with removing old burn out wiringand refixing the existing position replacement of unserviceable parts including rewiring and PCC works around the Feeder Pillar Box complete all as specified and directed.
45S&F MCCB 63 Amps, 4 Pole, 415 Volt, with breaking capacity 16 KA complete all as specified and directed.
46S&F MCCB 100 Amps, 4 Pole, 415 Volt, with breaking capacity 16 KA complete all as specified and directed.
47M&L for MCCB 4 Pole, 415 Volt, adjustable type 160 Amps with breaking capacity 36 KA complete all as specified and directed.
48M&L for MCCB 4 Pole, 415 Volt, adjustable type 200 Amps with breaking capacity 36 KA complete all as specified and directed.
49M&L for MCCB 4 Pole, 415 Volt, adjustable type 350 Amps with breaking capacity 36 KA complete all as specified and directed.
50M&L for MCCB 4 Pole, 415 Volt, adjustable type 400 Amps with breaking capacity 36 KA complete all as specified and directed.
51M&L for MCCB 4 Pole, 415 Volt, adjustable type 630 Amps with breaking capacity 50 KA complete all as specified and directed.
52S&F in replacement of Digital time switchincluding 3 phase power contactor 40 Amps and taking out old unserviceable timer & contactor complete all as specified and directed. Make : Legrand Cat No - 412641 & 3 phase contactor 40 A, Code No - 412549, Havells, L&T.
53Dismantling and taking down street light fittings any size and refixing again after erecting of LT Pole etc complete all as specified and directed.
54S&F cable junction box for street lights of size 155 x 210 x 92 mm IP-66 with integrated membranes/metric knockouts for cable entry of 10 to 25 Sqmm LT UG cable suitable for 415 Volts, 50 Hz, 3 Phase 4 Wireincluding clamp made out of MS flat 30 x 5 mm, nuts, bolts, washers etc complete and mounted on security light pole complete all as specified and directed. Make - Hensel cat Part No - DK 2525G with terminals
55S&F LED street light fitting 60 Watt, 230 Volt AC outdoor type with high pressure die cast aluminum hosing and heat resistant complet with driver, lamp bracket with impact and corrosion resistant including thermal mangement in multiple optics compete with IP 65/66 protection complete and taking down oldunserviceable street light fitting and type and any wattage complete all as specified and directed.
56S&F LED flood light fitting 70 Watt, 230 Volt AC outdoor type with thermal mangement in multiple optics and equipped with IP66 protection with impact corrosion resistant complete with driver and lamp and taking down old unserviceable flood light fitting and type and any wattage complete all as specified and directed.
57Supply, install, commissioning and testing CPRI approved factory fabricated, floor mounted outdoortype LT Feeder Pillar Box of suitable size fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 x 50 x 6 mm frame and 750 mm above the normal ground level complete factory made totally enclosed dust and vermin proof double door both side hinge opening arrangement on front and back with locking arrangement cable entry andexist from bottom with cable glands and gaskets, aluminium bus bar 250 Amps rating(01 Set) fixed on porcelain insulator with internal wiring with suitable size of aluminium strips to be used for incoming and outgoing connection of all switches/MCCB"s & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with copper lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint including necessary PCC (1:3:6) type C-2 as in foundation comprising of the following complete all as specified and directed :-
58(a)INCOMING
59(i)Thermal magnetic and microprocessor release MCCB 125 Amps, 4 Pole, 36 KA with front operated locking device - 01 Nos.Make : Legrand catpart No-420096, Havells, L&T.
60(b)OUTGOING
61(i)Thermal magnetic MCCB 63 Amps, 4 Pole, 415V, 16 KA. Qty- 02 Nos. Make : Legrand catpart No - 420013, Havells, L&T.
62(ii) MCB 32 Amps, 2 Pole. Qty- 01 Nos Make :Legrandcatpart No - 408617, Havells, L&T or equivalent.
63(c)Digital time switchincluding 3 phase power contactor 40 Amps. Make : Legrand Cat No - 412641 & 3 phase contactor 40 A, Code No - 412549, Havells, L&T. Qty - 01 Nos
64(d) (i)Digital Voltmeter 0 - 500 Volts with selector switch - 1 Set.
65(ii)Digital Amperemeter 0 - 200 Amps with selector switch - 1 Set.
66(iii) Indicator Lamp - R - Y - B (Set of three).
67(iv)Frequency meter 40-55 Hz - 01 Nos
68Supply, install, commissioning and testing CPRI approved factory fabricated, floor mounted outdoortype LT Feeder Pillar Box of suitable size fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 x 50 x 6 mm frame and 750 mm above the normal ground level complete factory made totally enclosed dust and vermin proof double door both side hinge opening arrangement on front and back with locking arrangement cable entry andexist from bottom with cable glands and gaskets, aluminium bus bar 600 Amps rating (01 Set) fixed on porcelain insulator with internal wiring with suitable size of aluminium strips to be used for incoming and outgoing connection of all switches/MCCB"s & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with copper lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint including necessary PCC (1:3:6) type C-2 as in foundationcomprising of the followingcomplete all as specified and directed : -
69(a)INCOMING
70(i)Thermal magnetic and microprocessor release MCCB 320 Amps, 4 Pole, 50 KA with front operated locking device - 01 Nos.Make : Legrand catpart No -422072, Havells, L&T.
71(b)OUTGOING
72(i)Thermal magnetic MCCB 63 Amps, 4 Pole, 415V, 16 KA. Qty- 07 Nos. Make :Legrand catpart No - 420013 , Havells, L&T.
73(ii)Thermal magnetic MCCB 25 Amps, 4 Pole, 415V, 16 KA. Qty- 01 Nos Make : Legrand catpart No - 420011 , Havells, L&T
74(iii) MCB 32 Amps, 2 Pole. Qty- 01 Nos.Make :Legrandcatpart No - 408617,Havells, L&T.
75(c) Digital time switchincluding 3 phase power contactor 40 Amps Make : Legrand Cat No - 412641 & 3 phase contactor 40 A, Code No - 412549, Havells, L&T. Qty - 01 Nos
76(d) (i)Digital Voltmeter 0 - 500 Volts with selector switch - 1 Set.
77(ii)Digital Amperemeter 0 - 200 Amps with selector switch - 1 Set.
78(iii) Indicator Lamp - R - Y - B (Set of three).
79(iv)Frequency meter 40-55 Hz - 01 Nos
80M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground levelconnecting to and including GI earth wire of size 4.0 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade pipe for protection ofGI wire to the extent of 7.5 m as earthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate No 3 of SSR Part-I (2009) including PCC foundation/chamber in mix 1:2:4 type B-1 with angle iron frameCI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for street light poles). Note :- Earth protection pipe & earthing wire upto and including 7.5 m length shall bedeemed included in unit rate quoted by the contractor.
81M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60 cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground levelconnecting to and including GI steel strip of size 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 40 mm dia medium grade pipe for protection ofGI strip to the extent of 7.5 m as earthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate No 3 of SSR Part-I (2009) including PCC foundation/chamber in mix 1:2:4 type B-1 with angle iron frameCI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for LT Panels). Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
82S&F Decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit 1 x 7 Watt LED lamp B-22 Basecomplete all as specified and directed. Make : Havells cat part No LHFXBON1TN5Q008 or equeivalent to Crompton/Orient/Bajaj
83S&F new geeration IP-65 LED post top family energy sanving environmental friendly, long life aestheticall designed with symmetrical light distribution spunaluminium landscape luminaire with high power 15 Watt LED as light source, clear cover offers bright illumination for different applicatons complete all as specified and directed. Make : Havells cat part No RUBYMINIPT15WLED830PSYMTOPC or equeivalent to Cormpton/Orient/Bajaj
84S&F 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served wth inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart inccluding 4 mm susension wire, one twin core aluminium conductor of size 6 Sqmmflat or circular complete all as specified and directed.
85Schedule of credit amount of Rs. 1,00,096.50 to be deducted during AOC.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail