Tender For Repair/Maint/Servicing Of Transformers Incl Dehydration Work, Painting, Certain Allied E/M Works And Apfc Panels Repairs At Katari Bagh, Nay, Garuda And All Other Area At Naval Base Kochi, kochi-Kerala

Military Engineer Services-MES has published Tender For Repair/Maint/Servicing Of Transformers Incl Dehydration Work, Painting, Certain Allied E/M Works And Apfc Panels Repairs At Katari Bagh, Nay, Garuda And All Other Area At Naval Base Kochi. Submission Date for this Tender is 14-12-2023. Electromechanical Work Tenders in kochi Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

40585592
Corrigendum : Tender For Repair/Maint/Servicing Of Transformers Incl Dehydration Work, Painting, Certain Allied E/M Works And Apfc Panels Repairs At Katari Bagh, Nay, Garuda And All Other Area At Naval Base Kochi
Open Tender
Indian
Kerala
kochi
14-12-2023

Tender Details

Repair / Maintenance / Servicing Of Transformers Incl Dehydration Work, Painting, Certain Allied E / M Works And Apfc Panels Repairs At Katari Bagh, Nay, Garuda And All Other Area At Naval Base Kochi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Nov-2023 Corrigendum1 BOQ 07-12-2023
2 07-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-12-2023

Key Value

Document Fees
INR 1000 /-
EMD
INR 110500.0 /-
Tender Value
INR 55.87 Lakhs /-

BOQ Items

Name of Work: Repair/Maint/Servicing of Transformers incl De-hydration work, painting, certain allied E/M works and APFC panels repairs at Kataribagh, NAY, Garuda and all other areas at Naval base Kochi
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre indepth and getting out in soft / loose soil for laying/removal/identifying the fault/relaying of cable etc all as specified and directed.
2Returning , filling ,inincluding spreading, levelling, wateringand well ramming in layers not exceeding 25 cm thick in soft / loose soilcomplete all as specified and directed.
3Removing excavated soil to a distance not exceeding 50 metre anddepositing where directed at a level, not exceeding 1.5 metre above the starting point complete all as specified and directed.
4M&L for sand cushioning and covering of UG cables in trenches(Note : For measurement purpose only punned thicknessshall be measuredand paid )
5Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size300 mm x 180 mm x 40 mm. laid in trenches for protectionofcable all as specified.
6Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size250 mm x 150 mm x 40 mm. laid in trenches for protectionofcable all as specified
7M & L 100 mm bore High density polyethylene pipes (HDPE) PN 10 laid in trenches/Wall/road crossing for suitable length as per sire requirement all as specified.
8M & L 40 mmboreMS tubes light grade galvanised, with all fittingslaid in trenches or walls or for passing earth strip, etc , completeincluding taking down old item.all as specified
9Cutting into existing bituminous carpet road/PCC hard standing/tiles for laying of pipes/UG cables, re filling, ramming and making good the disturbed surfaces with cold mix bitumen to match with the existing complete all as directed.
10Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 x 6 mmby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified including taking down of old item and as directed by the Engr-in-Charge. NOTE :-(i) Cost of GI pipe medium grade 40 mm shall deemed to be included in the quoted rate (ii) GI strip and GI pipelength of upto 7.5 RM shall deemed to be included in the quoted rate and over and above shall be measured and paid separately
11Material and labour for earth continuity conductor or main earthing strip fixed to wall on batten or porcelain insulators or recess or chases or buried in ground or drawn inGI pipe 40 mm or fixed with poles or any other indicated sitution for loop earthing etc as required using galvanised iron strip of size 32 X 6 mm complete all as directed. NOTE :-(i)GI Pipe 40 mm shall be measured and paid separately
12Supply and fixing , cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable forXLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmmx 3 coreincluding taking down old item, all as specified. Make : 3M M-seal / Raychem / Denson / Cab Seal
13Supply and fixing , cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable forXLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmmx 3 coreincluding taking down old item, all as specified. Make : 3M M-seal / Raychem / Denson / Cab Seal
14Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable forXLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm x 3coreincluding taking down old item, all as specified. Make : 3M M-seal / Raychem / Denson / Cab Seal
15Supply and fixing , cable straight through jointing kit for 11 KV (Earthed) grade cable, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmmincluding taking down old item ,all as specified. Make : 3M M-seal / Raychem / Denson / Cab Seal
16Supply and fixing , cable straight through jointing kit for 11 KV (Earthed) grade cable, heat shrink type joint complete with jointing material and accessories suitable forXLPE armoured aluminium conductor cable of size 240 sqmm to 400 sqmm x 3 core including taking down old item ,all as specified. Make : 3M M-seal / Raychem / Denson / Cab Seal
17Servicing of transformer any type ,11000 Volt / 433 Voltsand 433 / 380 volt, step down/Step up,indoor/out door,type of capacity upto 250 KVA comprising following work services:-(a) Disconnection of cable termination of HT & LT ends. (b)Opening of top cover by removing nuts, bolts and all mounting accessories and conservator tanks for visual inspection. (c) checking of HT/LT insulators including internal inspection (d)Replacement of corroded nuts/bolts with double washers, burned lugs,etc by new one (e) Servicing of tap changing gears by cleaning and polishing tapping contact points.(f) Removing, cleaning, polishing of bushings and studs of both HT/LT side by using soft cotton cloth including checking for cracking and refixing the same. (g) Refixing all cable terminals HV & LV sides and transformer top cover, conservator tank and other fitments in position. (h)Cleaning and heating/replacing of silica gel in breather. (j)Mechanical inspection and fixing of buchholz relay. (k) Connecting HT & LT side with existing incoming and outgoing cables including re-connection of earth strip/lead. (l) HT side cable connection shall be made with new HT tape & M SealMonoplast as required at site. (m) All marshalling boxes to be cleaned. (n) All the terminal connection of control and relay wiring to be checked and tighten. (o) Examine the rollers carefully includes greasing them properly.
18All as per item No.17 here in above but of capacity 315 KVA to 500 KVA complete all as specified and directed.
19All as per item No.17 here in above but of capacity 630 KVA to 1000 KVA complete all as specified and directed.
20All as per item No.17 here in above but of capacity 1250 KVA to 1500 KVA complete all as specified and directed. Note for Item No.17 to 20 : (i) New buchholz relay, New silica gel, New bushes, studs, etcrequired for replacement shall be measured and paid for separately as "Supply only" and cost of taking down of all these materials shall deemed to be included in the above quoted rate. (ii) The cost of replacement of unserviceable nut, bolt with double washers, HT / LT tape used, M-Seal, Monoplast, cable end socket, etc shall deemed to be included in the quoted rate. (iii) For the inspection of internal deffect of transformer, the contractor shall provide proper lifting arrangements like tripod, chain and pully, T&P, etc and the rent shall deemed to be included in the quoted rate. (iv) Contractor shall isolate the transformer from the supply and do earth the transformer properly while servicing the transformer.
21Servicing of OLTC and RTCC of transformer of capacity from 750 kVA to 1600KVA comprising following work services:- (a)Opening ofcover by removing nuts, bolts and all mounting accessories and conservator tanks for visual inspection. (b)Replacement of corroded nuts/bolts with double washers, burned lugs,etc by new one (c) Servicing of tap changing gears by cleaning and polishing tapping contact points.(d) Checking of mechanical operation (e) Checking of operation of RTCC including AVR (f) All the terminal connection of control and relay wiring to be checked and tighten.
22De-hydration/ filtrationof transformer oil by employing on line filtrationplant to achieve di-electric strength not less than minimum 50 KV including following work services:-(a) Removal of all suspended particles such as dust, rust, scales, collidedCarboneoxidation sludge, etc upto < 1 microne. (b) De-hydration of transformer oil under vacuum. (c) Circulation of heated oil and filling of treated oil in transformer tank. (d) Top up the transformer oil upto the level (e) Clean the transformer. NOTE : (i) Contractor shall use the vehicle mounted filtration plant with new suitable size heavy duty hose pipe. (ii) The transformer oil required for replacing/top up shall be measured and paid separately as "Supply only" (iii) Conducting field testing of di-electric strength of the transformer oil before and after filtration.
23Rectifying and arresting the oil leakage of transformer of any capacity, replacing the following components of the transformer such asgaskets, "O" rings,etc. Rectify the leaks in a variety of areas such as radiator fins, flanges, circuit breakers, valves, fastener assemblies, Oil leakage through pin hole / crack joint , drain valve / radiator valve , Oil leakages through Gasket joints. Applying putty/M-Seal Monoplast/brazing where ever necessary. NOTE :(i) Cost of all type of gasket, "O" rings, putty/M-Seal Monoplast, lugs, nut bolt, double washers, and cleaning of transformer etc shall deemed to be included in the quoted rate.
24Supply only Transformeroil having die electric strength not less than 45KV complete all as specified and directed.
25Supply and fix silica gel of superior quality for air breather of transformer installed at Naval Base, Kochi complete all as specified and directed.
26Supply and fix PVC breathing assy of Transformerwith new silica gel 250 gm as per existing make and type complete all as specified and directed.
27Supply and fix PVCbreathing assy of Transformerwith new silica gel 500 gm as per existing make and type complete all as specified and directed.
28Supply and fix PVC breathing assy of Transformerwith new silica gel 1000 gm as per existing make and type complete all as specified and directed.
29Supply and fixing in repairs brass terminal stud with nuts, check nut, oil seal and washer for HT side of transformer of any make as per sample up to 400 KVA transformer complete all as specified and directed.
30Supply and fixing in repairs brass terminal stud with nuts, check nut, oil seal and washer for HT side of transformer of any make as per sample from 500 KVA to 1000 KVA transformercomplete all as specified and directed.
31Supply and fixing in repairs brass terminal stud with nuts, check nut, oil seal and washer for HT side of transformer of any make as per sample from 1250 KVA to 1500 KVA transformer complete all as specified and directed.
32Supply and fixing in repairs brass terminal stud with nuts, check nut, oil seal and washer for LT side of transformer of any make as per sample up to 400 KVA transformer complete all as specified and directed.
33Supply and fixing in repairs brass terminal stud with nuts, check nut, oil seal and washer for LT side of transformer of any make as per sample from 500 KVA to 1000 KVA transformer complete all as specified and directed.
34Supply and fixing in repairs brass terminal stud with nuts, check nut, oil seal and washer for LT side of transformer of any make as per sample from 1250 KVA to 1500 KVA transformer complete all as specified and directed.
35Supply and fixing in repairs bushing of HT side as per existingsize/Model of the capacity up to 400 KVA transformer.
36Supply and fixing in repairs bushing of HT side as per existingsize/Model of the capacity 500 KVA to 1000 KVA transformer complete all as specified and directed.
37Supply and fixing in repairs bushing of HT side as per existingsize/Model of the capacity 1250 KVA to 1500 KVA transformer complete all as specified and directed.
38Supply and fixing in repairs bushing of LT side as per existingsize/Model of the capacity up to 400 KVA transformer complete all as specified and directed.
39Supply and fixing in repairs bushing of LT side as per existingsize/Model of the capacity 500 KVA to 1000 KVA transformer complete all as specified and directed.
40Supply and fixing in repairs bushing of LT side as per existingsize/Model of the capacity 1250 KVA to 1500 KVA transformer complete all as specified and directed.
41Supply and fixing in repairs buchholz relay as per existingsize/Model suitable for transformer up to 1500 KVA transformer complete all as specified and directed.
42Supply and fixing transformer oil temperature gauge, range shall be0 to 120 degree C as per existing type and model including taking down old one complete all as specified and directed.
43Supply and fixing GM gate valve 15 mm dia, ISI Marked suitable for oil inlet/outlet valves of transformer including taking down old one complete all as specified and directed.
44Supply and fixing GM gate valve 20 mm dia, ISI Marked suitable for oil inlet/outlet valves of transformer including taking down old one complete all as specified and directed.
45Supply and fixing GM gate valve 25 mm dia, ISI Marked suitable for oil inlet/outlet valves of transformer including taking down old one complete all as specified and directed.
46Material and labour for disconnecting transformer supply both HT/LT side, transporting to local workshop, opening transformer, removing the core and winding assembly, taking out the HT/LT burnt winding, re-winding with super enameledcopper winding wire of same gauge and turn varnishing, drying in oven, Clean the sludge of transformer oil and ensure that ducts are not blocked,Clamp the windings firmly without any movement. Adjust the vertical tie bars to tighten loose windings or spacers. Properly tight the special coil adjustment bolt, if provided, Check the proper operation of tap changing switch, Tight all connections and fix all fitments in position. Conduct insulation resistance test, Clean the bushing & stud and examine for cracks and chips, replace if required. De-hydration/filteration of oil for di-electric strength not less than 45 KV, topping up with new oil, checking HT/LT bush for desired IR value, re-assemble, transporting back to install the same with system, testing with NO LOAD & LOADcomplete all as directed for any capacity. NOTE : (i) De-hydration and new oil for topping up will be measured and paid separately (ii) The crane and vehicle shall be provided by the contractor at his own risk and cost shall deemed to be included in the quoted rate.
47Shifting of standby trolley mounted transformer or any other transformer of capacity up to 750 KVA including its HT / LT cable from one location to another location and back to original site inside the Naval Base and Kataribagh by using toeing vehicle and crane if necessary.Dismantling the HT/LT connection of the existing faulty transformer, connecting the HT / LT cable of the trolley mounted transformer with the existing load, connecting the transformer with body and neutral earth with existing earth lead and testing with load complete all as specified and directed. NOTE : (i) The works includes the removal and refixing ofall connection, cable, etc of both transformers. (ii) Contractor shall shift and connectthe trolley mounted transformer immedeately within four hrs when AGE E&M / JE E&M inform through mobile message (iii) If contractor fails to shift the trolley mounted transformer within four hrs, a panality of Rs.3000.00 per hour after four hour shall be imposed. (iv) Rent of toeing vehicle, labour used, tools used shall deemed to be included in the quoted rate. (v) Contractor shall take care of transformer while shifting, any damage found while shifting will be rectify by the contractor at his own risk.
48Supply and layingin trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade having cross sectional area 3 core 185 sqmmincluding taking down old item, all as specified.
49Supply and layingin trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade having cross sectional area 3 core 240 sqmmincluding taking down old item, all as specified.
50Supply and layingin trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade having cross sectional area 3 core 300 sqmmincluding taking down old item, all as specified.
51Supply and layingin trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 3.5 core 300 sqmmincluding necessary thimble, gland, etc andtaking down old item, all as specified.
52Supply and layingin trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 3.5 core 240 sqmmincluding necessary thimble, gland, etc andtaking down old item, all as specified.
53Supply and layingin trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 3.5 core 185 sqmmincluding necessary thimble, gland, etc andtaking down old item, all as specified.
54Supply and layingin trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 3.5 core 150 sqmmincluding necessary thimble, gland, etc andtaking down old item, all as specified.
55Supply and layingin trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 3.5 core 120 sqmmincluding necessary thimble, gland, etc andtaking down old item, all as specified.
56Supply and fixing , cable straight through jointing kit for 1.1 KV (Earthed) grade cable, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 240 to300 sqmm including taking down old item ,all as specified. Make : 3M M-seal / Raychem / Denson / Cab Seal
57Supply and fixing , cable straight through jointing kit for 1.1 KV (Earthed) grade cable, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 sqmm to 185 sqmmincluding taking down old item ,all as specified. Make : 3M M-seal / Raychem / Denson / Cab Seal
58Supply and fixing , cable straight through jointing kit for 1.1 KV (Earthed) grade cable, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 120 sqmmincluding taking down old item ,all as specified. Make : 3M M-seal / Raychem / Denson / Cab Seal
59Material and labour for painting of transformers capacity up to 250 KVA with or without OLTC including HT/LT side marshallingbox with one coat of synthetic enamel paint by using spray painting methodafter and including cleaning of existing surface of all dirtand greasy materials alongwith marking of SM/MES Nos with sticker letters n exc 2 cm height at appropriate places complete after isolating the transformer from the electric supply and to be earthed all as specified and as directed . Note: (i) The superficial area for the purpose of painting shall be considered approx 2 Sqm. (ii) Contractor"s rep shall be present during the entire time of painting (iii) The safety of painter/electrician/supervisor/engineer working with transformer shall be at contractors risk. (iv) The rent of the air compressor, tools, etc shall deemed to be included in the quoted rate. (v) Marking of SM / MES No if any shall be deemed with quoted rate.
60All as per item No.59 here in above but of capacity 315 KVA to 500 KVA complete all as specified and directed.
61All as per item No.59 here in above but of capacity 630 KVA to 1500 KVA complete all as specified and directed.
62Material and labour for hiring, transporting and finding the HT 11 KV/ LT UG cable fault location in any location inside Naval Base and Kataribagh area for any size of cable by using portable cable fault locator and marking the exact location all as directed.
63Servicing ofAutomatic Power Factor Correction (APFC) panel Quarterly of the capacity 100 kVAr complete comprising MDXL type heavy duty capacitor having low watt loss, APFC relay, MCCB, Cooling fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning all contact points, tightening of all connections including replacement of unserviceable components, thimbles, nut bolt and washers,etc if necessary, cleaning the entire panel by using hot blower complete all as directed by Engineer-in-Charge.
64All as per item No.63 above but capacity 125 kVAr
65All as per item No.63 above but capacity250 kVAr
66All as per item No.63 above but capacity300 kVAr
67All as per item No.63 above but capacity 375 kVAr
68All as per item No.63 above but capacity 500 kVAr Note for item No 63 to 68.(i) The above quotedrates are inclusive of the cost of replacement ofnut, bolt & washers, thimbles used while servicing the APFC panels or in any working time as directed by the engr-in-charge. (ii) The rent of the tools using shall deemed to be inclued in the above quoted rate. (iii) Spares for unserviceable componentsto be replaced shall be measured and paid separetely. (iv) If the contractor is failed to carried out the servicing of the panel, a panality ofdouble the quoted rate will be recovered. (v) Contractor shall be ensure the APFC panel functional through out the contract period and power factor reading shall not be fall under 0.95 PF. (vi) If any APFC panel found not functional or the power factor falls to 0.94 or low PF, a penal recovery of Rs.500.00 per day shall be recovered in this connection Accepting officer"s decision is final.
69Supply and fixing in repairs of Heavy duty capacitors 3 to 25 kVAr, voltage 440 volt, 3 Phase, cylindrical, having operating losses 0.35 W/kVAr of Make L&T / MEHAR/Havells/C&S/ABB or equivalent make in list of makes.
70Supply and fixing in repairs APFC relay, 4 Stage, auto set function, having digital display of makeL&T / BLR-CX/Havells/C&S/ABB or equivalent make in list pf makes.
71Supply and fixing in repairs APFC relay, 6 Stage, auto set function, having digital display of makeL&T / BLR-CX/Havells/C&S/ABB or equivalent make in list pf makes.
72Supply and fixing in repairs APFC relay, 8 Stage, auto set function, having digital display of makeL&T / BLR-CX/Havells/C&S/ABB or equivalent make in list pf makes.
73Supply and fixing in repairs APFC relay, 12 Stage, auto set function, having digital display of makeL&T / BLR-CX/Havells/C&S/ABB or equivalent make in list pf makes.
74Supply and fixing in repairs thyrister switching module, 440 volt, 50 Hz, having high peaking inverse voltage of 2.2 kV suitable for 10 kVAr rating of make : L&T/Schnieder/ABB/Havells
75Supply and fixing in repairs thyrister switching module, 440 volt, 50 Hz, having high peaking inverse voltage of 2.2 kV suitable for 25 kVAr rating of make : L&T/Schnieder/ABB/Havells
76Supply and fixing in repairs thyrister switching module, 440 volt, 50 Hz, having high peaking inverse voltage of 2.2 kV suitable for 50 kVAr rating of make : L&T/Schnieder/ABB/Havells
77Supply and fixing in repairs capacitor duty contactor, 415 volt, 3 phase, 50 Hz, 1 NO+NC, suitable for kVAr rating upto 5 kVAr of make : L&T/Schnieder/ABB/Havells/C&S
78Supply and fixing in repairs capacitor duty contactor, 415 volt, 3 phase, 50 Hz, 1 NO+NC, suitable for kVAr rating upto 12.5 kVAr of make : L&T/Schnieder/ABB/Havells/C&S
79Supply and fixing in repairs capacitor duty contactor, 415 volt, 3 phase, 50 Hz, 1 NO+NC, suitable for kVAr rating upto 15 kVAr of make :L&T/Schnieder/ABB/Havells/C&S
80Supply and fixing in repairs capacitor duty contactor, 415 volt, 3 phase, 50 Hz, 1 NO+NC, suitable for kVAr rating upto 20 kVAr of make :L&T/Schnieder/ABB/Havells/C&S
81Supply and fixing in repairs capacitor duty contactor, 415 volt, 3 phase, 50 Hz, 1 NO+NC, suitable for kVAr rating upto 25 kVAr of make : L&T/Schnieder/ABB/Havells/C&S
82Supply and fixing in repairs capacitor duty contactor, 415 volt, 3 phase, 50 Hz, 1 NO+NC, suitable for kVAr rating upto 50 kVAr of make : L&T/Schnieder/ABB/Havells/C&S
83Supply and fixing in repairs 3 pole contactor 70 amp, type MNX 70, 415 volt, 3 phase, 50 Hz, 2 NO+2NC.
84Supply and fixing in repairs 3 pole contactor 110 amp, type MNX 110, 415 volt, 3 phase, 50 Hz, 2 NO+2NC.
85Supply and fixing in repairs 3 pole contactor 140 amp, type MNX 140, 415 volt, 3 phase, 50 Hz, 2 NO+2NC.
86Supply and fixing in repairs electronic time switch of Make : L&T/Legrand/GIC/Havells/C&S/ABB
87Supply and fixing in repairs side mounting Add-On block on auxiliary contact block suitable for MOC, 1NO+1NC of Make : L&T / Havells / Schnieder/ABB
88Supply and fixing in repairs HRC fuse, DIN type fuse links,250 Amps of make : L&T / Havells / Schnieder /C&S
89Supply and fixing in repairs HRC fuse, DIN type fuse links,160 Amps of make : L&T / Havells / Schnieder /C&S
90Supply and fixing in repairs HRC fuse, DIN type fuse links,125 Amps of make : L&T / Havells / Schnieder /C&S
91Supply and fixing in repairs HRC fuse, DIN type fuse links,80 Amps of make : L&T / Havells / Schnieder /C&S
92Supply and fixing in repairs PVC Cooling fan for APFC panel 6"Sweep.
93M & L forpainting to APFC panel with two coat of synthetic enamel paint by using spray paintafter isolating the electric supply then thoroughly cleaning the surface to remove dirt, grease, oil stainsand preparation of old painted surfaces, etc and making the surface ready to paint including re-connection ofelectric supplyall as specified and directed by Engineer-in-Charge
94Supply and fix in repair MCCB, Three pole, 630 Amps with thermal magnetic release with range 500 - 630 Amp,, having breaking capacity 36 KA complete all as specified and directed. Make : L&T/ Havells / Indo Asian
95Supply and fix in repair MCCB, Three pole, 400 Amps with thermal magnetic release with range 320 - 400 Amp,, having breaking capacity 36 KA complete all as specified and directed. Make : L&T/ Havells / Indo Asian
96Supply and fix in repair MCCB, Three pole,250 Amps with thermal magnetic release with range 200 - 250 Amp,, having breaking capacity 25 KA complete all as specified and directed. Make : L&T/ Havells / Indo Asian
97Supply and fix in repair MCCB, Three pole, 200 Amps with thermal magnetic release with range 160 - 200 Amp,, having breaking capacity 36 KA complete all as specified and directed. Make : L&T/ Havells / Indo Asian
98Supply and fix in repair MCCB, Three pole,160 Amps with thermal magnetic release with range 125 - 160 Amp,, having breaking capacity 25 KA complete all as specified and directed. Make : L&T/ Havells / Indo Asian
99Supply and fix in repair MCCB, Three pole, 125 Amps with thermal magnetic release with range 100 - 125 Amp,, having breaking capacity 25 KA complete all as specified and directed. Make : L&T/ Havells / Indo Asian
100Supply and fix in repair MCCB, Three pole, 63/100Amps with thermal magnetic release with range 50-63/80 - 100 Amp,, having breaking capacity 25 KA complete all as specified and directed. Make : L&T/ Havells / Indo Asian
101Material and labour for removing the existing HT UG cables of any size from any location and rerouting the same at any other location as directed by the Engineer-in-charge.