Tender For Additional /Alternator And Improvement Of Bldg No T-34 And T-35 At Mh Dehradun., dehradun-Uttarakhand

Military Engineer Services-MES has published Tender For Additional /Alternator And Improvement Of Bldg No T-34 And T-35 At Mh Dehradun.. Submission Date for this Tender is 07-12-2023. Mobile Generator Tenders in dehradun Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

40581244
Corrigendum : Tender For Additional /Alternator And Improvement Of Bldg No T-34 And T-35 At Mh Dehradun.
Open Tender
Indian
Uttarakhand
dehradun
07-12-2023

Tender Details

Tender For Additional /Alternator And Improvement Of Bldg No T-34 And T-35 At Mh Dehradun.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 77700.0 /-
Tender Value
INR 38.82 Lakhs /-

BOQ Items

Name of Work : ADDN/ALTN & IMPROVEMENT OF BLDG. NO T-34 & T-35 AT MH GE DEHRADUN.
Sl. No. Item Description
1Taking down chowkat with shutter any description n. exc 1.5 Sqm each complete all as specified and directed.
2All as per item No 1 here in above but exc. 1.5 Sqm and not exceeding 4 Sqm each.
3S&F mild steel pressed steel frames of size 105x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed.
4S&F Pressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed. Note: Hollow portion of frame shall be filled in cement concrete1:2:4 type B-0 using 12.5 mm graded stone aggregate.
5S&F 35mm thick second-class hardwood (Golden Teak) glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge complete all as specified in SSR Pt I-2009 section 8 clause 8.24 (a) and as directed.
6S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including provision of suitable blocks for taking mortice locks, latches or other fittings complete all as specified and directed.
7S&F 30 mm thick moulded WPC factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side plain with density not less than 600 Kg/cum.Manufactured by an ISO: 9001-2015 certified company. The door should be water proof, termite proof, fire retardant and having screw holding capacity complete all as specified and directed.
8S&F factory made 100 % solid wood plastic composite (WPC) door frame 75x50 mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termite proof, fire retardant and having good screw holding capacity all as per specification and drawing complete all as specified and directed.
9S&F factory made steel window with side hung shutters including box type hinges with steel handle, steel peg stay, tower bolt etc. complete with glazing bars, dovetailed or welded complete all as specified.
10S&F factory made steel window with side hung shutters including box type hinges with steel handle, steel peg stay, tower bolt etc. complete without glazing bars, dovetailed or welded complete all as specified and directed.
11S&F factory made steel ventilator with top hung shutters including hinges with steel handle, steel peg stay, tower bolt etc. complete all as specified and directed.
12M&L for 20 - 25 mm thick machine cut Kota stone slab as in flooring over and including 15 mm thick screed bed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges and polishing in granite finish complete all as specified and directed.
13S & F in repair aluminium grill of size 75x75x4-5 mm thick fixed with aluminium frame including taking down old grill complete all as specified and directed.
14S&F stainless steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm complete all as specified and directed.
15S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in square area n. exc. 0.5 Sqm in each pane complete all as specified and directed.
16S&F mild steel frame work for such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290. Gde-E-165 including necessary welding, drilling hole complete all as specified and directed.
17Dismantling of old aluminium anodised partition with frame, (fixed type) with aluminum glazing clip, snap beading and refixing the same in other locations complete all as specified and directed
18S&F stainless steel barrel tower bolts 150 mm long one piece and fixed complete all as specified
19S&F stainless steel butt hinges, medium weight 100 mm long one piece and fixed with screws/welded to frame, complete all as specified and directed.
20S&F stainless steel handles 150 mm long one piece and fixed with screws/welded to frame complete all as specified and directed.
21S&F 300 mm long stainless-steel sliding door bolt (bolt not less than 12 mm dia) with hasp & staple and fixing clips of SS sheet, and SS fixing bolts and fixed complete all as specified and directed.
22S&F floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed to floor of size 140 mm complete all as specified and directed.
23M&L for applying two coats of synthetic paint on new wooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and directed.
24Dismantling of asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings complete all as specified and directed.
25S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws complete all as specified and as directed.
26S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws and profile should match with galvalume sheet complete all as specified and as directed.
27Dismantling of framed or unframed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
28S&F mild steel rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors, post, pipes; fixed with angle cleats or other connecting plates Fe-290 (Gde E-165) complete all as specified and directed
29M&L for mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410 -W (Gde-E- 250) quality-A complete all as specified and directed.
30Dismantling of old rolled sections as in main and cross beams, hip and jack rafters; purlins and refixing the same in other locations complete all as specified and directed
31M&L for applying two coats of synthetic enamel paint on new/ old or previously untreated steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and directed.
32S&F in repair SS grade 204 drapery rod 20mm dia including decorative brackets, decorative finals at both ends complete all as specified and directed.
33Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
34M&L for 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement complete all as specified and directed.
35M&L for 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed.
36M&L for Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. including screed bed 15 mm thick in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles including dismantling of existing tiling complete all as specified and directed.
37M&L non-skid / mat finish ceramic colour tiles of size 300 mm x 300 mm and 6- 7 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
38M&L glazed ceramic colour tiles size 300 mm x 450 mm x 6-7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 and dismantling of existing wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
39S&F in repairs PVC connection 15 mm dia 450 mm long with brass fly nut at both ends complete all as specified and directed.
40S&F in repair vitreous china squatting pan “ORISSA PATERN” of size 580 mm x 440 mm, white, with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and directed.
41S&F in repair 10 litre capacity PVC low level cistern ‘white’ with inlet, float valve including brackets with 32 mm dia PVC pipe/bend 600 mm long complete all as specified and directed.
42S&F in repair vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and directed.
43S&F in repair pillar taps, brass, with capstan head, fancy type chromium , screwed down high pressure with or without lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed.
44S&F in repair brass chromium plated overhead shower with shower arm complete all as specified and directed.
45S&F in repair 15 mm bore Angle cock/stop valves, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
46S&F in repair 15mm bore Bib taps long body cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
47S&F in repair CP grating 100mm to 125 dia round fix on floor/nahani trap with hole/without fixed with cement mortar, complete all as specified and directed.
48Taking up or down steel tubing and connection including removal from site bore of pipe 15mm complete all as specified and directed.
49Taking up or down steel tubing and connection including removal from site bore of pipe 20mm complete all as specified and directed.
50S&F 15mm bore pipe medium grade galvanised iron with all fittings fixed to wall and ceiling or laid in floor complete all as specified and directed.
51S&F 20mm bore pipe medium grade galvanised iron with all fittings fixed to wall and ceiling or laid in floor complete all as specified and directed.
52M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc half but n exc full brick wall complete all as specified & directed.
53S&F in repair 75 mm bore UPVC (SWR) pipe pressure 4kgf/cm2 single socketed in any length with rubber ring, fixed on wall / laid in trenches complete all as specified and directed.
54S&F in repair 110 mm bore UPVC (SWR) pipe pressure 4kgf/cm2 single socketed in any length with rubber ring, fixed on wall/ laid in trenches complete all as specified and directed.
55S&F in repair 75 mm bore UPVC (SWR) bend with oval access door, "T" socket reducer etc complete all as specified and directed.
56S&F in repair 110 mm bore UPVC (SWR) bend with oval access door, "T" socket reducer etc complete all as specified and directed.
57Providing & fixing false ceiling ofDesigner tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and cross "T" of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c toform a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mmand laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable wire of 4mm dia with galvanised butterfly level clips, spaced at 1200mm c/c along main "T", bottom exposed width of 15mm of all "T"" sections of 4mm dia GI wire shall be pre-painted with polyester paint and black painted groove at centre of size 4mm depth and 4.5mm width, including taking down existing ceiling of any type all complete at all heights complete all as specified and directed.
58Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
59M&L brick work with sub class "B’ brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 including demolition of existing old brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
60M&L brick work with sub class "B’ brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall including demolition of existing brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed.
61Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
62M & L 15 mm thick rendering on brick work or concrete surface in cement mortar 1:6, surface finished even and fair complete all as specified and directed.
63M & L 15 mm thick rendering in cement mortar 1:4 on brick work or concrete surface, surface finished even and fair complete all as specified and directed.
64M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified in SSR Part I and directed.
65M&L for preparation of newly plastered surface of wall and applying two coat of cement base paint over a coat of primer complete all as specified and directed.
66M&L for preparing of old decorated surfaces and applying two coats of cement-based paint on walls complete all as specified and directed.
67M&L for preparing of old plastered and un plastered surfaces of wall and applying two coats of distemper oil emulsion complete all as specified and directed.
68Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and as directed.
69M&L for cutting/griding and polishing of exterior kota stone/terrazzo flooring complete all as specified and directed.
70S&F rotational moulded polyethylene water storage tanks Capacity of tank 1000 litres triple layer, white colour, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including dismantling of existing unserviceable tank and removing from site, complete all as specified and directed.
71S&F ball valve high pressure of PTMT with epoxy coated alum rod & high-density plastic ball screwed for 20mm bore iron pipe and fixed (minimum weight 20mm-210 gms) complete all as specified and directed.
72Taking down carefully existing aluminium/copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulator, sockets, wooden boards, laminated sheets from sunken boxes boards, shades light fitting etc for refixing and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed.
73M& L for refixing the tube light fittings and lamp holders obtained against item No 72.
74M&L point wiring with 1. 5 Sqmm FRLS PVC insulated unsheathed multistranded single core copper conductor cable in PVC concealed conduit wiring and including making good with factory made modular pressed terminal box (recessed) suitable for modular fittings with 1.5 Sqmm PVC insulated copper conductor earth continuity wire for one light/fan point controlled by one switch completion all as specified and directed for the following.
75(a)One light/fan point controlled by one switch.
76(b)One 5 pin socket outlet 5 Amps controlled with one switch on the same board.
77(c)One 5 pin socket outlet 5 Amp controlled by one switch on independent board.
78All as per item No 74 above but with 2.5 sqmm multistrand copper conductor cable for one 15 Amp socket outlet controlled by one switch on independent board and 2.5 sqmm PVC insulated multi strand copper conductor cable as continuous earth wire complete.
79M&L for point wiring with 1.5 Sqmm (Nominal area) FRLS PVC insulated and unsheathed single core cable 1100 Volts grade with stranded copper conductor in existing steel/PVC conduitwith continuous earth wire 1.5 Sqmm FRLS PVC insulated, unsheathed stranded copper conductor cable and connected to common earth dolly, with and including 1.6mm thick cadmium plated sunk MS pressed steel terminal boxes with 3.0 mm thick hylam sheet cover fixed with brass screw complete with all accessories for one light point/Fan point controlled by one ,one way switch.
80(a)All as per Item No 76 here-in- before but one three pin 5 Amps socket out let on the same board with other switches.
81(b)All as per Item No 76 here-in- before but one three pin 5 Amps switch socket out let on the independent board with other switches.
82(c)All as per Item No 76 here-in- before but one three pin 15 Amps switch socket out let on the independent board with 2.5 sq mm PVC insulated FRLS copper conductor and 1.5 Sqmm FRLS copper conductor for continuous earthing complete.
83S&F switch piano flush button single pole one way 5 Amp completion all as specified and directed.
84S&F socket outlet, 5 Pin, 6 Amp 2 in 1, flush type, universal completion all as specified and directed.
85S&F socket outlet 2 in 1, 5 pin, 5- and 15-Amp flush type completion all as specified and directed.
86S&F switch piano flush button single pole one way 15 Amp completion all as specified and directed.
87S&F ceiling rose 3 terminal/PVC/polycarbonate, isolated body completion all as specified and directed.
88S&F fan regulator stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd completion all as specified and directed.
89S&F angular lamp holder including 9W/12W, PVC/polycarbonate type with back plate suitable for angular fittings completion all as specified and directed.
90S&F Ultra bright LED Tube light fitting of LED 20 w including requiredlength of 1.5 Sqmm PVC multistranded copper conductor forelectrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed.
91Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size completion all as specified and directed.
92Supply, fixing, connecting and testing of 35-watt LED building security light luminaries with min 10 KV surge protector die cast alluminium housing and including bracket 32 mm GI pipe bend to shape including clamp fastener, bolts, nuts & washers of min 1.2 Mtr including grouting etc and 3 core 1 sqmm PVC insulated cable from ceiling rose to light fitting completion all as specified and directed.
93Supply & fix ceiling fan 1200mm sweep, 230 Volts AC single phase, 50 Hz 3 blades, double ball bearing, energy saving complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 sqmm from ceiling rose to connector, including extra GI/MS pipe down rod, as per site requirement complete all as specified and directed.
94Supply and fix electric water heater, storage type steel body and heating element up to 2 KW of capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc completion all as specified and directed.
95Supply and fixing in replacement for Distribution board TPN 4 Way double door, for mounting MCBs/isolator, etc factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar complete all as specified and directed. Note:- DB and MCCB/MCB shall be of same make.
96S&F MCCB 63 Amps four pole 415 volts thermal magnetic release ICU=100% ICS having breaking capacity 16 KA including connection terminal strip complete all as specified & directed
97Sheet metal enclosure MCB DB, double door, 08-way SPN, 240 volts with 200 Amps rated bus bar with blanking plates wherever required and I.P. 20-degree protection completion all as specified and directed.
98S&F MCB single pole and neutral 240 volts, 25 to 40 Amps completion all as specified and directed.
99S&F MCB single pole 240 volts, 6 to 32 Amps completion all as specified and directed.
100Taking down submain wiring of any size any type and in any position metallic/non-metallic PVC conduit of wooden batten complete all as specified and directed.
101M&L for sub main wiring with 2 run x 6 Sqmm + 4 sqmm earth wire single core PVC insulated cable un sheathed multistranded copper conductor LT 1100 volts grade FRLS cable IS-694 (ISI marked with valid CML No ) drawn in & including PVC conduit of dia not less than 25mm in concealed (ISI marked with valid CML No ) including its all fittings/accessories with one run single core copper cable 4 sqmm multistranded conductor(ISI marked with valid CML No) colour code as a earth continuity and connecting up to DB with suitable lugs all as specified and directed.
102S&F Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 of MES Schedule Part-I connecting to earthing point and testing on completion with and including 15 mm bore light grade G.I. protection pipe (0.5 metre beyond pit to main switch), PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangementwith funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and e work, completion all as specified and directed.
103M& L for faking down fan, sealing cable end, dismantling blades and removing fan and blades to store completion all as specified and directed.
104Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area size 25 Sqmm 4 Core completion all as specified and directed.
105Excavation in trenches n exc. 1.5 m wide and n" exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
106Returning, filling of excavated soil, including spreading levelling, watering and well ramming in layers, not exceeding 25cm complete all as specified and directed.
107Removing of surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point completion all as specified and directed.
108Sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables completion all as specified and directed.
109Bricks, old size sub class `B" laid in trenches with width wise along the alignment of the cable as protection completion all as specified and directed.
110S&F tube "Light" grade galvanised with all fitting laid in trenches, fixed to wall and floor of 50 mm dia for cable protection complete all as specified and directed.