Tender For Repair / Replacement Of Pump, Motor, Starter, Control Panels, Apfc Panels And Connected Work At Rajouri Under Age E/M Of Ge 862 Ews, Udhampur-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair / Replacement Of Pump, Motor, Starter, Control Panels, Apfc Panels And Connected Work At Rajouri Under Age E/M Of Ge 862 Ews. Submission Date for this Tender is 14-12-2023. Motor Work Tenders in Udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

40579534
Corrigendum : Tender For Repair / Replacement Of Pump, Motor, Starter, Control Panels, Apfc Panels And Connected Work At Rajouri Under Age E/M Of Ge 862 Ews
Open Tender
Indian
Jammu And Kashmir
Udhampur
14-12-2023

Tender Details

Tender For Repair / Replacement Of Pump, Motor, Starter, Control Panels, Apfc Panels And Connected Work At Rajouri Under Age E / M Of Ge 862 Ews

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Nov-2023 Corrigendum1 BOQ 02-12-2023
2 02-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-12-2023
3 09-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-12-2023
4 14-Dec-2023 Corrigendum2 Other 14-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work:-Repair / replacement of pump, motor, starter, control panels, APFC panels and connected work at rajouri under AGE E/M of GE 862 EWS
Sl. No. Item Description
1Disconnecting the 150 HP centrifugal pump of any make from the motor after disconnection of mechanical tyre coupling, suction/discharge pipe line and unbolting from foundation base plate,loading/unloading of pump pn vehicle and transportation of the pump from Naushera E/M installation to workshop as directed by Engineer-in-Chargefor repair/replacement/maintenance of unserviceable parts including strip opening and dismantling of pump for repair, with necessary oiling and greasing and again transportation of the pump through vehicle from workshopto Naushera E/M installations after necessary repair/ replacement/ maintenanceandloading/ unloading the pump and re-coupling the pump with motor on base frame, after checking of the alignment with motor, testing, commissioning complete all as directed by Engr-in-Charge. ( Note : Spare parts of pumpwill be measured and paid separately under respective items).
2S&F in repair of mechanical seal/ gland packing suitable for 150 HP capacity pump, complete all as specified and directed
3S&F in repair of bronz impeller suitable for 150 HP capacity pump,complete all as specified and directed
4S&F in repair ofneck ring suitable for 150 HP capacity pump,complete all as specified and directed
5S&F in repair of bush suitable for 150 HP capacity pump,complete all as specified and directed
6S&F in repair of CI key suitable for 150 HP capacity pump,complete all as specified and directed
7S&F in repair of pump sleeves suitable for 150 HP capacity pump,complete all as specified and directed
8S&F in repair ofstainless steel shaft suitable for 150HPcapacity pump,complete all as specified and directed
9S&F in repair of pump coupling complete by drilling grinding etc for 150HPcapacity pump, complete all as specified and directed
10S&F in repair of pump casing for 150HP capacity pump,complete all as specified and directed
11S&F in repair of impeller lock nut for 150HP capacity pump, complete all as specified and directed
12S&F in repair of water deflector for 150HP capacity pump,complete all as specified and directed
13S&F in repair of oil seal for 150HP capacity pump,complete all as specified and directed
14S&F in repair of stuffing box for 150HP capacity pump,complete all as specified and directed
15S&F in repair of bearing housing for 150HP capacity pump,complete all as specified and directed
16All as per srl item No-1 here in before but for pump capacity 40 to 50 HP . Note old unserviceable parts shall be measured and paid saperately respective items
17S&F in repair of mechanical seal/ gland packing suitable for 40 to 50 HP capacity pump, complete all as specified and directed
18S&F in repair bronz impeller suitable for 40 HP to 50 HP capacity pump complete all as per specified and directed.
19S&F in repair neck ring suitable for 40 HP to 50 HPcapacity pump complete all as per specified and directed.
20S&F in repair bush suitable for 40 HP to 50 HP capacity pump complete all as per specified and directed.
21S&F in repair CI key suitable for 40 HP to 50 HP capacity pump complete all as per specified and directed.
22S&F in repair pump sleeves suitable for40 HP to 50 HP capacity pump complete all as per specified and directed.
23S&F in repair stainless steel shaft suitable for40 HP to 50 HPcapacity pump complete all as per specified and directed.
24S&F in repair pump coupling complete by drilling grinding etc for 40 HP to 50 HP capacity pump complete all as per specified and directed.
25S&F in repair pump casing for 40 HP to 50 HP capacity pump complete all as per specified and directed.
26S&F in repairimpeller lock nut for 40 HP to 50 HP capacity pump complete all as per specified and directed.
27S&F in repairwater deflector for 40 HP to 50 HP capacity pump complete all as per specified and directed.
28S&F in repair oil seal for 40 HP to 50 HP capacity pump complete all as per specified and directed.
29S&F in repair stuffing box for 40 HP to 50 HP capacity pump complete all as per specified and directed.
30S&F in repair bearing housing for 40 HP to 50 HP capacity pump complete all as per specified and directed.
31All as per srl item No-1 here in before but for pump capacity 15 to 30HP . Note old unserviceable parts shall be measured and paid saperately respective items
32S&F in repair of mechanical seal/ gland packing suitable for 15 to 30 HP capacity pump, complete all as specified and directed
33S&F in repair bronze impeller suitable for 15 HP to 30 HP capacity pump complete all as per specified and directed.
34S&F in repair neck ring suitable for 15 HP to 30 HP capacity pump complete all as per specified and directed.
35S&F in repair bush suitable for 15 HP to 30 HPcapacity pump complete all as per specified and directed.
36S&F in repair CI key suitable for 15 HP to 30 HPcapacity pump complete all as per specified and directed.
37S&F in repair pump sleeves suitable for 15 HP to 30 HPcapacity pump complete all as per specified and directed.
38S&F in repair stainless steel shaft suitable for 15 HP to 30 HP capacity pump complete all as per specified and directed.
39S&F in repair pump coupling complete by drilling grinding etc for 15 HP to 30 HPcapacity pump complete all as per specified and directed.
40S&F in repair pump casing for 15 HP to 30 HPcapacity pump complete all as per specified and directed.
41S&F in repairimpeller lock nut for 15 HP to 30 HPcapacity pump complete all as per specified and directed.
42S&F in repairwater deflector for 15 HP to 30 HPcapacity pump complete all as per specified and directed.
43S&F in repair oil seal for 15 HP to 30 HPcapacity pump complete all as per specified and directed.
44S&F in repair stuffing box for 15 HP to 30 HPcapacity pump complete all as per specified and directed.
45S&F in repair bearing housing for 15 HP to 30 HPcapacity pump complete all as per specified and directed.
46All as per srl item No-1 here in before but for pump capacity 5 to 10HP . Note old unserviceable parts shall be measured and paid saperately respective items
47S&F in repair of mechnical seal/ gland packing suitable for 5 to 10 HP capacity pump, complete all as specified and directed
48S&F in repair bronz impeller suitable for 5 to 10HP capacity pump complete all as per specified and directed.
49S&F in repair neck ring suitable for 5 to 10HP capacity pump complete all as per specified and directed.
50S&F in repair bush suitable for 5 to 10HP capacity pump complete all as per specified and directed.
51S&F in repair CI key suitable for 5 to 10HPcapacity pump complete all as per specified and directed.
52S&F in repair pump sleeves suitable for 5 to 10HP capacity pump complete all as per specified and directed.
53S&F in repair stainless steel shaft suitable for 5 to 10HP capacity pump complete all as per specified and directed.
54S&F in repair pump coupling complete by drilling grinding etc for 5 to 10HP capacity pump complete all as per specified and directed.
55S&F in repair pump casing for 5 to 10HP capacity pump complete all as per specified and directed.
56S&F in repairimpeller lock nut for 5 to 10HP capacity pump complete all as per specified and directed.
57S&F in repairwater deflector for 5 to 10HP capacity pump complete all as per specified and directed.
58S&F in repair oil seal for 5 to 10HP capacity pump complete all as per specified and directed.
59S&F in repair stuffing box for 5 to 10HP capacity pump complete all as per specified and directed.
60S&F in repair bearing housing for 5 to 10HP capacity pump complete all as per specified and directed.
61M&L for rewinding with super enamelled copper winding wire of existing gauge/ size / quality to match with the existing as comply including all insulating material such insulating paper, sleeves, varnish etc drying the copper winding after varnish with blower or heater including soldering all internal connection and testing completeall as specified and directed.
62M&L for replacement of ball bearing No SKF/NBC-6503 for motor including refixing of nuts, bolts, washer and sleeves etc, complete all as specified and directed.
63All as per srl item No-62 here in before but ball bearing No SK/NBCF-6308.
64All as per srl item No-62 here in before but ball bearing No SKF/NBC-6309.
65All as per srl item No-62 here in before but ball bearing No SKF/NBC-6312.
66All as per srl item No-62 here in before but ball bearing No SKF/NBC-6316.
67All as per srl item No-62 here in before but ball bearing No SKF/NBC-7311.
68All as per srl item No-62 here in before but roller bearing No SKF/NBC-NU-307.
69All as per srl item No-62 here in before but roller bearing No SKF/NBC-NU-411.
70All as per srl item No-62 here in before but roller bearing No SKF/NBC-NU-308.
71Lifting out and lowering ofsubmersible pump set Capacity 03 HP to 25 HP of any make from bore well for carrying out repair in civil workshop including transportation and dismantling/repair of pumpset by taking out old unserviceable parts and lowering the same after repair/replacementand testing complete all as directed. (Note : Spare parts of pump/motor i.e. ball bearing, stainless steel shaft,bush, cast iron keys, re-winding wire of new super enamelled coper wire of existing gauge/size/quality will be measured and paid separately under respective items.)
72M&L for cutting and removing burnt winding of submersible motor of capacity of 3 HP, rewinding of motor with super enamelled subersible copper winding wire of original gauge and size including insulation etc & testing, complete all as specified and directed. Note: The rate quoted above this item including copper winding complete.
73M&L for cutting and removing burnt winding of submersible motor of capacity of 25 HP, rewinding of motor with super enamelled subersible copper winding wire of original gauge and size including insulation etc & testing, complete all as specified and directed. Note: The rate quoted above this item including copper winding complete.
74S&F in repair for neck ring of submersiable pump of 3HP capacity of any make, complete all as specified and directed
75S&F in repair for coupling for pump and motor of submersiable pump of 3HP capacity of any make, complete all as specified and directed
76S&F in repair for stainless steel sleave for pump shaft of submersiable pump of 3HP capacity of any make, complete all as specified and directed
77S&F in repair for bowl assembly of any size pump of submersiable pump of 3HP capacity of any make, complete all as specified and directed
78S&F in repair for impeller of submersiable pump of 3HP capacity of any make, complete all as specified and directed
79S&F in repair for body bush of submersiable pump of 3HP capacity of any make, complete all as specified and directed
80S&F in repair for stainless steel shaft of submersiable pump of 3HP capacity of any make, complete all as specified and directed
81S&F in repair for neck ring submersiable pump of any make capacity of 25 HP, complete all as specified and directed
82S&F in repair for coupling for pump and motor of submersiable pump of 3HP capacity of any make, complete all as specified and directed
83S&F in repair for stainless steel sleave for pump shaft of submersiable pump of 25HP capacity of any make, complete all as specified and directed
84S&F in repair for bowl assembly of any size pump of submersiable pump of 25HP capacity of any make, complete all as specified and directed
85S&F in repair for impeller of submersiable pump of 25HP capacity of any make, complete all as specified and directed
86S&F in repair for body bushof submersiable pump of 25HP capacity of any make, complete all as specified and directed
87S&F in repair for stainless steel shaft of submersiable pump of 25HP capacity of any make, complete all as specified and directed
88S&F in repair for old/ existing burnt/worn out contact point forfixed and moving type contact suitablesize/ shape for star delta starter of 15to 40 HP capacity motor complete all as specified
89All as per srl item No-88 here-in-before but capacity of motor 50 HP
90All as per srl item No-88 here-in-before but capacity of motor 100 HP to 150 HP.
91M&L for cleaning, scrubbing the surface to remove dust and rust of pump motor set and iron base frame inclusive of one primer coat, one under coat and one finishing coat of smoke grey paint to pump set and black paint to iron base frame to the pump set of any capacity in different location any capacity, complete all as specified and directed.
92S&F in repair replacement of broken cooling fan of centerifugal motor capacity 150 HP, make kirloskar as per existing fitted, complete all as specified and directed by Engr-in-Charge.
93Supply and applying grease LG-240/280 as requirement for centerifugale pump, complete all as specified and directed by Engr-in-Charge.
94Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 95 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE)
95Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 120 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE)
96Excavation in trenches not exc 1.5m wide and and not exc. 1.5m depth wide in hard/dense soil for laying electric cables/pipes etc including getting out excavated earth and trimming the sides and bottoms of trenches complete all as specified and directed.
97Supply and filling sandfor cushioning of cable protection in two layers ie. First layer 18cm before laying of cable and second layer 15 cm thick after laying of cable in trenches/ ductincluding spreading, levelling, punning down complete all as specified and directed.
98M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat,size 230mm x 115mmx 75mm, complete all as specified and as directed.
99Returning, filling in including spreading, leveling, watering and well ramming in layers not exc. 25cm in hard and dence soil complete all as specified and directed.
100Removal of surplus soil to a distance not exc. 50m and depositing where directed at a level not ex. 1.5m above the starting point complete all as specified and directed.
101S&F in repair for On load change over switch of sheet steel enclosure confirmingSS Enclosure,front operated 4Pole 415 V, 50 Hzof Capacity 100Amps, complete all as specified and directed.
102S&F in repair for Onload change over switch of sheet steel enclosure confirmingSS Enclosure, front operated 4Pole 415 V, 50 Hzof Capacity 125Amps, complete all as specified and directed.
103S&F in repair for Onload change over switch of sheet steel enclosure confirmingSS Enclosure, front operated 4Pole 415 V, 50 Hzof Capacity 160Amps, complete all as specified and directed.
104S&F in repair for Onload change over switch of sheet steel enclosure confirmingSS Enclosure, front operated 4Pole 415 V, 50 Hzof Capacity 200Amps, complete all as specified and directed.
105S&F in repair for Onload change over switch of sheet steel enclosure confirmingSS Enclosure, front operated 4Pole 415 V, 50 Hzof Capacity 600Amps, complete all as specified and directed.
106S&F in repairfor moulded case circuit breakers with fixed thermal magnetic setting. MCCB 3Pole, 100 Amps, 36KA, 415 V, 50 Hz, complete all as specified and directed.
107S&F in repairfor moulded case circuit breakers with fixed thermal magnetic setting. MCCB 3Pole, 160 Amps, 36KA, 415 V, 50 Hz, complete all as specified and directed.
108S&F in repairfor moulded case circuit breakers with fixed thermal magnetic setting. MCCB 3Pole, 200 Amps, 36KA, 415 V, 50 Hz, complete all as specified and directed.
109S&F in repairfor moulded case circuit breakers with fixed thermal magnetic setting. MCCB 3Pole, 400 Amps, 36KA, 415 V, 50 Hz, complete all as specified and directed.
110S&F in repairfor moulded case circuit breakers with fixed thermal magnetic setting. MCCB 3Pole, 630 Amps, 36KA, 415 V, 50 Hz, complete all as specified and directed.
111M&L for painting of MS/CI pipes, sluice valves and tees, flanges, hand rails in filteration plants, with two coats of synthetic enamal paint including preparation old surface by scrapping etc complete all as specified and directed.
112Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground levelconnected to and including 32X6mm thick galvanised iron strip by means ofbolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete inclulding taking down existing unserviceable earthing all as specified and directed. (Note:-Earth strip and protection pipe upto 7.5mtr is included in the rate quoted)
113S&F for galvanised iron strip 32x6 mm buried in ground and on wall surface as per site requirement (for additional earthing lead beyond 7.5 meters per earth, if so required at site ) and interconnection of earth pits complete including removal of old unserviceable all as specified and directed.
114S&F in repair for DOL starter, AC 3 phase, 415 Volt, 50 Hz with sheet metal enclosure type suitable for 7 HP motor including making connection complete all as sepcified and directed.
115S&F in repair for fully Automatic Star-delta starter, AC 3 phase, 415 Volt, 50 Hz with sheet metal enclosure type suitable for 10 HP motor including making connections, complete all as sepcified and directed.
116All as per srl item No 115 above but for 30 HP motor
117All as per srl item No. 115 above but for 40 HP motor
118All as per srl item No. 115 above but for 50 HP motor
119All as per srl item No. 115 above but for 150 HP motor
120M&L in repair for mild steel work including cutting, bending to shape, welding drilling holes, jointing by nuts, bolts, washers etc using MS chanel, equal angle, flat iron, sheet steel etc including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed.
121S&F in repair for 20 mm bore gun metal gate valve (ISI marked) heavy duty with iron wheel head, screwed both ends for GI iron pipe, complete all as specified and directed.
122All as per serial item No-121 here-in-before but size 25 mm dia bore
123M&Lin repair of aluminium tubular lugs of size 25 Sqmm to 320 Sqmm (cable size), complete all as specified and directed.
124M&L in repair of aluminium tubular lugs of size 10 Sqmm to 180 Sqmm (cable size), complete all as specified and directed.
125M&L in repair for painting of pump control panel internally as well as external surfaces complete with two coat of synthetic enameled paint over a coat of red oxide primer of approved colour including of preparation of old surface of panel, complete all as specified and directed.
126M&L for 16 sqmm, 3 core submersible copper conductor multistranded cable, LT 1100volt grade,water proof lowering with the column pipe into the bore/ well and testing complete after taking down old unserviceable cable, complete all as specified and directed.
127M&L for 10 sqmm, 3 core submersible copper conductor multistranded cable, LT 1100volt grade,water proof lowering with the column pipe into the bore/ well and testing complete after taking down old unserviceable cable, complete all as specified and directed.
128Supply and laying or fixing or passing through pipe, 1100voltsgrade heavy dutycablewith PVC insulated multi strand copper conductor cable size 70 Sqmm, single core unsheathed flexible complete after taking down old unserviceable cable all as specified and directed.
129Supply and laying or fixing or passing through pipe, 1100voltsgrade heavy dutycablewith PVC insulated multi strand copper conductor cable size 35 Sqmm, single core unsheathed flexible complete after taking down old unserviceable cable all as specified and directed.
130Supply, installation, commissioning and testing of LT Feeder pillar offactory made (CPRI approved), outdoor cubical compartmental type, double door, both side openable with hinged doors & locking arrangement,outgoing cable chamber with same rated aluminium strip from cable chamber to MCCB output, made out of 3.15 mm thick mild steel CRCAsheet supported and fixed on structural frame of angle iron of size50 x50 x 6mm angle iron frame including painting to all internal & external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground but PCC foundation (1:2:4) type B1, with danger notice plate (02 Nos) of 1.6mm thick mild steel sheet of size 20cmx15cm, vitreous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, suitable for 3 phase 4 wire system 415 volts grade consisting of copper bus bar capacity of 200 Amps with necessary wiring with PVC sheathed stranded copper conductor of 1100 volts of appropriate length size with and including fixing lugs, bolts, screws etc complete including taking out old LT paneland comprising of the following accessories:- INCOMING :- (a) MCCB, 160 Amp, 4 Pole,36 KA - 01 No. (b) Digital Combimeter (7in1) with 4 digit LED Display -01 No (c) Indicating lamp LED type one set in incoming phase. (d) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 volt grade IS 694 maked of appropriate gauge including all copper lugs. OUTGOING:- (a) MCCB, 100 Amp, 3 Pole, 36 KA - 01 No.(b) MCCB, 63 Amp, 3 Pole, 36 KA - 01 No.(c) Spare space providedfor MCCB 63 amp -01 No (Notes : Make of panel, size and drawing shall be got approved from GE before placing order for procurement)
131S&F in repair MIHSP openwell submersible pump motor 1.5HP single phase 230 volt maintain head from 70 feet to 90 feet with all connected fitting, complete all as specified and directed
132S&F in repair for analoge control panel stater with complete fitting for single phase submersible motor 1.5 HP, complete all as specified and directed.
133S&F in repair self priming monoclock pump motor 1.5 HP single phase 230 volt maintain head from 75 feet to 120 feet with all connected fitting, complete all as specified and directed by Engr-in-Charge.
134S&F in repair for analoge control panel stater with complete fitting for single phase monoblock motor 1.5 HP, complete all as specified and directed.
135S&F in repair for self priming monoblock pump motor capacity 1 HP single phase 230 volt maintian haed from 60 feet to 90 feet with all connecting fitting, complete all as specified and directed by Engr-in-Charge.
136S&F in repair for fully automatic water pressure pump of capacity 0.5HP auto cut and auto on with all fittings for connection of pump, complete all as specified and directed
137S&F in repair of GI perfortage cable tray of iron and galvanised coating, side rail height 75mm with electrolytic polishing filling wall or ground, complete all as specified and directed by the Engr-in-Charge.
138S&F in repair for auxiliary power contactor confromance to IEC 60947-4-1, 440 volt AC supply type AC-3 rating for current rating 160 Amp capacity, complete all as specified and directed.
139All as per serial item No-138 here-in-before but capacity of 63 Amp.
140All as per serial item No-138 here-in-before but capacity of 50 Amp.
141All as per serial item No-138 here-in-before but capacity of 40 Amp.
142All as per serial item No-138 here-in-before but capacity of 32 Amp.
143S&F in repair bucket grease gun with trolley capacity 5 kg, useful for cleaning greasing of pump and machinery high pressure hand operated pump, pump has steel construction with cast head solid steel pump chamber with 2.2 m of high pressure hose fitted with accessories, complete all as specified and directed.
144S&F in replacement for MCB four pole, 240 volts, 32 amps, "C" series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
145S&F in replacement for MCB four pole, 240 volts, 63 amps, "C" series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
146S&F in repair over load relay of three phase 440 volt AC confromance to IEC 60947-4-1, CE marking rating up to 124 to 198 Amp, complete all as specified and directed .
147All as per Srl Item No. 146 here-in-before but capacity of 62 to 99 Amp.
148All as per Srl Item No. 146 here-in-before but capacity of 55 to 70 Amp.
149All as per Srl Item No. 146 here-in-before but capacity of 37 to 50 Amp.
150S&F in repair for spreader links suitable for 440 volt MCCB 4 pole capacity of 160 Amp to 250 Amp, complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail