| 1 | Supplying and fixing of the following sizes of PVC casing and capping on surface including tee, elbow, bend, coupling, corners, ss screws, nails, nylon plugs etc as required |
| 2 | 20mm x 10mm |
| 3 | 32mm x 10mm |
| 4 | 40mm x 10mm |
| 5 | Supplying and fixing of the following sizes of Rigid PVC pipes along with the accessories in surface, including tee, bend, elbow, coupling, ss screws, nails, nylon plugs etc as required |
| 6 | 20mm |
| 7 | 25mm |
| 8 | Note: rates of only ISI marked cables have been taken in the following items.Unless otherwise specified only such cables shall be used in the work brand preferable are Anchor, Havells, V-guard, Finolex, RR,. |
| 9 | 1 sqmm |
| 10 | 1.5 sqmm |
| 11 | 2 sqmm |
| 12 | 2.5 sqmm |
| 13 | 4 sq mm |
| 14 | 6 sqmm |
| 15 | 10 sqmm |
| 16 | supplying and earthing with GI pipe 32mm dia 2.5m long including accessaries ,nut and bolt washer etc complete as required |
| 17 | supplying and drawing of No 16SWG copper wire in the existing PVC casing capping /conduit pipe etc as earth continuity |
| 18 | Supplying and fixing of the following Modularswitches, sockets, regulators, blank plates, etc areon the existing switch box/cover including connections etc. |
| 19 | Note: Preferable brands are Crabtree,Havells,AnchorRoma, MK, Legrand, . |
| 20 | 1. 2 Module 32A D.Pswitch with indicator |
| 21 | 2. 2 Module 20A D.Pswitch with indicator |
| 22 | 3. 2 Module 16A 1way switch with indicator (mega) |
| 23 | 4. 1 Module 16A 2 way switch |
| 24 | 5. 1 Module 16A 1way switch with indicator |
| 25 | 6. 1 Module 6A 1 way switch |
| 26 | 7. 1 Module 10A 2 way switch |
| 27 | 8. 2 Module 10A socket |
| 28 | 9. 2 Module 20A socket |
| 29 | 10. 2 Module 10ABell push switch |
| 30 | 11. 1 Module 4 Step fan speed regulator |
| 31 | Supplying & fixing of following type of bells indicaters including connections as required . |
| 32 | 1. Call bell |
| 33 | 2. Ding dong bell |
| 34 | 3. Musical bell |
| 35 | Supplying and fixing of following switches, sockets, regulators, etc are on the existing switch box/cover including connections etc. |
| 36 | Note: Preferable brands are Anchor, Elle, Indica, colours |
| 37 | 1. 6A 1 way flush type switch |
| 38 | 2. 6A 2 way flush type switch |
| 39 | 9. 16A 1 way switch |
| 40 | Supply and fixing of Modular surface Box, Plat- Brand- Havells, Crabtree, GM,…etc) |
| 41 | 1 Modular surface box |
| 42 | 1 Modular Plate |
| 43 | 2 Modular surface box |
| 44 | 2 Modular plate |
| 45 | 3 Modular surface box |
| 46 | 3 Modular plate |
| 47 | 4 Modular surface box |
| 48 | 4 Modular plate |
| 49 | 6 Modular surface box |
| 50 | 6 Modular plate |
| 51 | 8 Modular surface box |
| 52 | 8 Modular plate |
| 53 | 10 Modular surface box |
| 54 | 10 Modular plate |
| 55 | 12 Modular surface box |
| 56 | 12 Modular plate |
| 57 | Supplying, installation, testing and commissioning of LEDtube light fitting of the following types complete with all accessories and tube, etc directly on ceiling / wall including s.s.screws, nails, nylon plugs connections and with flexible wire, etc as required. |
| 58 | Note: Preferable brands are Philips, Havells, Bajaj, Wipro, Halonix, Osram, Anchor. etc |
| 59 | 1. LED Tubelight set 18 /20 watts4feet |
| 60 | 2. LED Bulb 6- 12 Watts |
| 61 | Supplying, installation, testing and commissioning ofPVC Bulk head light fitting with suitable LED bulb all accessories etc. directly on wall including s.s.screws, nails, nylon plugs and connections with flexible wire as required. |
| 62 | Note: Preferable brands are Philips, Havells, Bajaj, Wipro, Halonix, Osram, Anchor.) |
| 63 | Supplying, installation, testing and commisionioning of LED Flood light30/50/100/150 WattsWall accessories etc. directly on wall/ pole including bulb screws, nails, nylon plugs, nut bolt,etc. and connections as required. |
| 64 | Note: Preferable brand Havells, Bajaj, Wipro, Philips ,Osram,Anchor or any reputed make |
| 65 | Supplying, installation, testing and commisionioningthe following type of ceiling fan without regulator including the wiring down rod of standard length with 1.5 sqmm PVC insulated coppercable / flexible twin twisted / round 2 core etc as required. |
| 66 | Note: Preferable brands are Anchor, Bajaj, Crompton Greaves, Havells,V-guard, Khaitan, Almonard |
| 67 | 1. Ceiling fan 900 mm sweep BLDC 5 star |
| 68 | 2.ceiling fan 1200 mm sweep BLDC 5 star |
| 69 | Supplying installation, testing and commissioning the following type of exhaust fan including the wiring with 1.5 sqmm PVC insulated copper cable / flexible twin twisted / round 2 core etc as required. |
| 70 | Note: Preferable brands are Anchor, Bajaj, Crompton Greaves, Havells, V-guard, Khaitan, Almonard |
| 71 | 1.Exhaustfan 300 mm |
| 72 | Supplying installation, testing and commissioning the following type of Wall mounting fan including the wiring with 1.5 sqmm PVC insulated copper cable / flexible twin twisted / round 2 core etc as required.Note: Preferable brands are Anchor, Bajaj, Crompton Greaves, Havells, V-guard, Khaitan, Almonard |
| 73 | 2. Wall mounting fan 400mm OSC type |
| 74 | Supplying and fixing of backlite pendent holder on the existingPVC junction box /TW box /round block/square block including connection |
| 75 | Supplying and fixing of PVC round block/ square block including screws/ nail etc and connections etc |
| 76 | Supplying and fixing of ceiling rose on the existing PVC junction box /round block including connections etc |
| 77 | Supplying and fixing of backlite slanding / straight holderon the existing PVC junction box / round block / square including connections |
| 78 | Supplying and fixing of following MCB Distribution box 230 V/415 V – 50Hz- with neuter link earth connection and provision for SP/ SPN /TPN /ELCB of 6/10/16/20/25/32/40/63/100 Amps per way including drilling hole on the board, connections and earthing the body etc as required. |
| 79 | Note: Preferable brands are Havells, ABB, Legrand, Action, etc. |
| 80 | 1. 2 way |
| 81 | 2. 4 way |
| 82 | 3. 6 way |
| 83 | 4.8 way |
| 84 | 5.10 way |
| 85 | 6.12 way |
| 86 | 7.16 way |
| 87 | 8. 18 way |
| 88 | 9. 20 way |
| 89 | 10.4 way SPN double door |
| 90 | 11.8 way SPN double door |
| 91 | 12. 16 way SPN double door |
| 92 | 13.20 way SPN double door |
| 93 | 14. 4way TPN double door |
| 94 | 15. 6way TPN double door |
| 95 | 16. 8 way TPN double door |
| 96 | 17. 16way TPN double door |
| 97 | Supplying and fixing offollowing 230 V/415 V – 50Hz- SP/ SPN /TPN /ELCB having rated current10/16/20/25/32/40/63/100 Amps on existing MCB distribution box including drilling hole on the board, connections and earthing the body etc as required. |
| 98 | Note: Preferable brands are Havells, ABB, Legrand, , etc. |
| 99 | 1. MCB SP 6 -40 Amps |
| 100 | 2.MCB SPN 10 - 40 Amps |
| 101 | 3.MCB SPN 16 - 63Amps |
| 102 | 4.MCB TPN 40-100 Amps |
| 103 | 5.RCCB SPN B 30mA-32A |
| 104 | 6.ELCB SPN 30mA – 20A |
| 105 | 7.ELCB SPN 30mA – 32A |
| 106 | 8.ELCB SPN 30mA – 40A |
| 107 | 9.ELCB TPN 30/100/300mA – 40A |
| 108 | 10.ELCB TPN 30/100/300mA – 63A |
| 109 | 11.ELCB TPN 30/100/300mA–100A |
| 110 | Supply and providing /fixing of wall mounding qubical single phase energy meter box(PVC) with transperent glass door facility. (300 x 250 x 200mm) including cut out fuese and MCB mounding provision. |
| 111 | Supply and providing /fixing of wall mounding qubical Three phase energy meter box(PVC) with transperent glass door facility. (450 x 300 x 250mm) including cut out fuese and MCB mounding provision. |
| 112 | Providing of service connection termination at both end supply /distribution & consumer installation through the enerty meter incuding fixing of meter board,meter,cut out etc as required. |
| 113 | 1. Single phase connection |
| 114 | 2. Three phase connection |
| 115 | Errection testing & commissioning of 20 Watt LED flood light fittings at the following heights including all consumables ete as required ( full cost ) |
| 116 | 1. Above 3 meter up to 6 meter |
| 117 | 2. Above 6 meter height |
| 118 | Errection testing and commissioning of LED Solar street light 20 W with inbuilt pannel, batteries and motion sensor etc. compact model ( reputed make lukar, GM and havels etc.or equivalent) including streetlight clamps and consumables etc. etc as required ( full cost) |
| 119 | 1. Above 3 meter up to 6 meter |
| 120 | Errection testing and commissioning of LED Solar street light 40 W with inbuilt pannel, batteries and motion sensor etc. compact model ( reputed make lukar, GM and havels etc.or equivalent) including streetlight clamps and consumables etc. etc as required ( full cost) |
| 121 | Demolishing of PVC casing & capping / PVC pipe including Aluminium / Copper condector,ceiling rose,round block,TW box etc ( Labour charge only) |