Tender For Servicing/Repairs/Maintenance And Replacement Of Unserviceable Acb/Mccb/Indicator/ Meters/Cables/ Earthings Etc Of Lt Panel Boards Installed At Zone 3 And 4 And Allied Works At Naval Dockyard, Visakhapatnam Under Ge (I) Dm Visakhapatnam, visakhapatnam-Andhra Pradesh

Military Engineer Services-MES has published Tender For Servicing/Repairs/Maintenance And Replacement Of Unserviceable Acb/Mccb/Indicator/ Meters/Cables/ Earthings Etc Of Lt Panel Boards Installed At Zone 3 And 4 And Allied Works At Naval Dockyard, Visakhapatnam Under Ge (I) Dm Visakhapatnam. Submission Date for this Tender is 06-12-2023. Air Circuit Breaker Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40570782
Corrigendum : Tender For Servicing/Repairs/Maintenance And Replacement Of Unserviceable Acb/Mccb/Indicator/ Meters/Cables/ Earthings Etc Of Lt Panel Boards Installed At Zone 3 And 4 And Allied Works At Naval Dockyard, Visakhapatnam Under Ge (I) Dm Visakhapatnam
Open Tender
Indian
Andhra Pradesh
visakhapatnam
06-12-2023

Tender Details

Servicing/Repairs/Maintenance And Replacement Of Unserviceable Acb/Mccb/Indicator/ Meters/Cables/ Earthings Etc Of Lt Panel Boards Installed At Zone 3 And 4 And Allied Works At Naval Dockyard, Visakhapatnam Under Ge (I) Dm Visakhapatnam

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Nov-2023 CORRIGENDUM NO 1 Other 29-11-2023
2 29-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 61800.0 /-
Tender Value
INR 30.90 Lakhs /-

BOQ Items

Name of Work:SERVICING/REPAIRS/MAINTENANCE AND REPLACEMENT OF UNSERVICEABLE ACB/MCCB/INDICATOR/ METERS/CABLES/EARTHINGS ETC OF LT PANEL BOARDS INSTALLED AT ZONE 3 & 4 AND ALLIED WORKS AT NAVAL DOCKYARD, VISAKHAPATNAM UNDER GE (I) DM VISAKHAPATNAM.
Sl. No. Item Description
1M&L for dismantling and taking out all cable connection from all switchgear and earthing connection of the indoor /outdoor panel board, removing carefully the complete panel board of size not less than 2.5 M x 2 M using sufficient man power /cranes from base of panel and keeping aside, re-construction of damaged panel foundation as per ground requirement in same place or other specified location with brick-work, plaster, foundation bolt, white wash to new plastered surface, reinstallation of complete panel and necessary cable end connection with suitable size of lugs/glands to respective cable/ switchgears, earthing complete. Note- (i) Relaying of cables due to change of foundation of panel and Brick work/plaster work shall be incl in quoted rate by contractor (ii) Required additional length of cables shall be measured and paid separately, (iii) Cable joints if require will be measured and paid separately, (iv) Required aluminium cable lugs /glands, nuts, bolts and washers, foundation bolts, white wash will be inclusive of quoted rate
2S & F Hot dip Galvanised wire mesh cable trays 105 x 300mm complete with tray, coupler, cover and cover clip to support clamps, securing properly to support strcture complete including dismantling existing LT cable of off sizes from building wall more than 3 mtr height form FL and relaying the same in proper alignment complete all as specified and directed. Make :- Legrand or equivalent.
3Supply, laying in cable tray/wall & connection PVC XLPE insulated, armoured havey duty electric cable with aluminium conductor, 1100 Volts grade cross section area 10 Sqmm 4 core incl dismantling taking down unsv one from wall, cable tray, trench complete all as specified and directed
4All as per item No. 3.00 above, but of size 16 sqmm, 4 core
5All as per item No. 3.00 above,but of size 25 sqmm, 4 core
6All as per item No. 3.00 above,but of size 35 sqmm, 4 core
7All as per item No. 3.00 above, but of size 50 sqmm, 3.5 core
8All as per item No. 3.00 above,but of size 70 sqmm, 3.5 core
9All as per item No. 3.00 above,but of size 120 sqmm, 3.5 core
10All as per item No. 3.00 above,but of size 240 sqmm, 3.5 core
11S/F of LT heat shrink straight through cable joint suitable for cable size LT 1100 volts grade, 4 core, 6 to 16 sqmm all as specified and directed. Make :- 3M, cat No MHS/Ox1.1KV(HSLA-1/4C) or equivelent of Denson/M Seal/MS Seal/RPG
12All as per item No. 11.00 above,but for cable sizes 25- 50 sqmm. Make 3M, cat No MHS/Ox1.1KV(HSLA-2/4C) or equivelent of Denson/M Seal/MS Seal/RPG
13All as per item No- 11 but for cable sizes 70-120 sqmm. Make :- 3M, cat No MHS/Ox1.1KV(HSLA-3/4C) or equivelent of Denson/M Seal/MS Seal/RPG
14All as per item No. 11.00 above,but for cable sizes 150-185 sqmm. Make :- 3M, cat No MHS/Ox1.1KV(HSLA-5/4C) or equivelent of Denson/M Seal/MS Seal/RPG
15All as per item No.11.00 above,but for cable sizes 240 to 300 sqmm. Make:- 3M, Cat No MHS/Ox1.1KV(HSLA-5/4C) or equivelent of Denson/M Seal/MS Seal/RPG
16All as per item No.11.00 above,but for cable sizes 400 to 500 sqmm. Make :- 3M, Cat No MHS/Ox1.1KV(HSLA-6/4C) or equivelent of Denson/M Seal/MS Seal/RPG
17Material and labour for repair, servicing, overahauling of indoor sub-distribution LT panel board of size upto 1.5m x 1.5m comprising busbar, MCCB, SDF, metering equipment after dismantling taking out all doors, covers from front and rear. Servicing comprising of thorough cleaning of complete inside cabinet with forced air and suitable cleaning agent, removing all dust/dirt, cleaning of all insulators, busbars, switchgears, all cable terminals with CTC and clean dry cloth, cleaning of outside surface with CTC and dry cloth, tightening of all nuts, bolts & washers. Repair comprising of replacement of burnt aluminium cable lugs, burnt switchgear, non-functional panel meters, non-functional indicator lamps, damaged panel metering wirings, nonfunctional selector switches, unsv CTs, unsv bakelite fuse with fuse base, damaged panel door/cover knobs & door locks, damaged door hinges, damaged cable insulation with coloured heat shrink insulating sleeves and required nuts, bolts & washers. Overhauling comprising of dismantling cable ends from switch gear/busbar taking out from panel board and cable duct, cutting at damaged portion, providing proper aluminium cable lugs and refixing to original position with required nuts, bolts & washers complete all as specified and directed.
18Note:- (i)Items require for replacement such as MCCB, SDF, MCB, Panel Meters, indicator lamps, CT, selector switches, metering cables will be measured and paid seperately as supply only. (ii) required cleaning items, aluminium cable lugs/ glands, nuts-bolts-washers, door hinges, door locks, door/cover knobs, bakelite fuse base with HRC fuse of panel wiring circuits shall be inclusive of quoted rate. (iii) ACB/busbar will be measured and paid as supply and fix. (iv) Servicing/maintinance of ACBs measured seperatelly where ever applicable.
19All as per item No.17.00 above, but of size above 1.5m x 1.5m upto 2.0m x 2.0m
20All as per item No.17.00 above but of size above 2.0m x 1.5m upto 2.0m x 2.5m
21All as per item No.17.00 above, but of size above 2.5m x 2.5m upto 3.5m x 3.5m
22All as per item No.17.00 above, but of size above 4.5m x 4.5m upto 5.5m x 5.5m
23All as per item No.17.00 above, but of size above 5.5m x 5.5m upto 6.5m x 6.5m
24Servicing, repair, maintinance of Air Circuit Breaker 400 Amps to 1600 Amps capacity by drawing out movable unit, forced air cleaning of movable and fixed unit, decarbonize breaker contracts and checking for any defects due to any flush/loose contact, cleaning of all fixed and moving contact point, terminal connection points with CTC,replacement of defective parts and re-fixing ACB, cables completes all as specified and directed. Note: (a) required male/female ACB contacts, trip coils, closing coils, electronic protection unitwill be measured as supply only.(b) all cleaning agents are included in the quoted rate.
25Supply only fixed contract of ACB 630A to 1250A all as specified and directed. Make- Schneider / ABB or as per existing make
26Supply only Moving contract of ACB 630A to 1250A all as specified and directed. Make- Schneider / ABB or as per existing make
27Supply Only Electronic protection unit of ACB 630A to 1250A all as specified and directed. Make- Schneider / ABB or as per existing make
28Supply Only shunt trip coil of ACB 630A to 1250A all as specified and directed. Make- Schneider / ABB or as per existing make
29Supply Only closing coil ACB 630A to 1250A all as specified and directed. Make- Schneider / ABB or as per existing make
30Supply only digital electronic Volt meter (0-500 volts range) withbuilt in selector switch suitable for LT 415 V panel flush pattern square type 96 mm x 96 mm with adopter completeall as specified and directed. Make:- Cat Part No:- 30002386 (DM3210) of Schneider or equivelent in Rishabh/L&T/AE
31Supply only digital electronic Ammeter withbuilt in selector switch suitable for LT 415 V panel flush pattern square type 96 mm x 96 mm with adopter completeall as specified and directed. Make:- Cat Part No:- 30002385 (DM3110) of Schneider or equivelent in Rishabh/L&T/AE
32Supply only LED Pilot lamps red, yellow and blue in colours of 22.5 mm dia to monitor on LT panel board suitable for 230 V AC supply all as specified and directed. Cat Part No:-1SFA619402R5231/32/33 Make:-Siemens/ C&S/ schneider/ ABB/ L&T/ Selzer
33Supply only metering current transformer of 1000/5 Amps, Class-1, 15VA, all as specified and directed. Make:-Rishabh, Cat No- TW-06 or equivelent of Kappa/ AE
34Supply only metering current transformer of 800/5 Amps, Class-1, 15VA, all as specified and directed. Make:-Rishabh, Cat No- TW-06 or equivelent of Kappa/ AE
35Supply only metering current transformer of 600/5 Amps, Class-1, 10VA, all as specified and directed. Make:-Rishabh, Cat No- TW-06 or equivelent of Kappa/ AE
36Supply only metering current transformer of 400/5 Amps, Class-1, 12.5VA, all as specified and directed. Make:-Rishabh, Cat No- TW-05 or equivelent of Kappa/ AE
37Supply only metering current transformer of 300/5 Amps, Class-1, 5VA, all as specified and directed. Make:-Rishabh, Cat No- TW-05 or equivelent of Kappa/ AE
38Supply onlyMCCB, 4 pole, 400 amp, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with micrologic 2 trip unit all as specified and directed. Make :-Schneider Cat Part No- LV432677 or equivelent of Legrand/ABB
39Supply only MCCB, 4 pole, 250 amp, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with micrologic 2 trip unit all as speicified and directed. Make :- Schneider cat Part No- LV431780 or equivelent of Legrand/ABB
40Supply only MCCB, 4 pole, 200 amp, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic release all as specified and directed. Make- Schneider cat Part No- LV431641 or equivelent of Legrand/ABB
41Supply only MCCB, 4 pole, 63 amps to 100 amp, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic release all as specified and directed. Make- Schneider cat Part No- 429642/40 or equivelent of Legrand/ABB
42Supply only MCCB, 3 pole, 400 amp, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with micrologic 2 trip uni all as specified and directed. Make- Schneider cat Part No- LV432676 or equivelent of Legrand/ABB
43Supply only MCCB, 3 pole, 250 amp, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic trip unit all as specified and directed. Make- Schneider cat Part No- LV431630 or equivelent of Legrand/ABB
44Supply only MCCB, 3 pole, 200 amp, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic trip unit all as specified and directed. Make- Schneider cat Part No- LV431631 or equivelent of Legrand/ABB
45Supply only MCCB, 3 pole, 160 amp, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic trip unit all as specified and directed. Make- Schneider cat Part No- LV430630 or equivelent of Legrand/ABB
46Supply only MCCB, 3 pole, 100A, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic trip unit all as specified and directed. Make- Schneider cat Part No- LV429630/32/35 or equivelent of Legrand/ABB
47Supply only MCCB, 3 pole, 63A , 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic trip unit all as specified and directed. Make- Schneider cat Part No- LV429630/32/35 or equivelent of Legrand/ABB
48Supply only MCCB, 3 pole,32 A , 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with thermal magnetic trip unit all as specified and directed. Make- Schneider cat Part No- LV429630/32/35 or equivelent of Legrand/ABB
49Supply and fix copper bus bar off sizes inside busbar chamber with all required nuts-bolts-washers and taking out old unserviceable bus bar all as specified and directed.
50M&L for painting of outer surface of complete LT Panel board of size upto 1.5M x 1.5M comprising ACBs/MCCBs/SDFs, busbar chamber, swich gear chamber, metering chamber cable termination/tray using one coat of synthetic enamel spray painting after preparation of surface, providing protection cover to all metering equipment, switchgears, cleaning of all non-metalic surface after completion of painting with paint remover all as specified and directed.
51All as per item No.49.00 above, but of size above 1.5m x 1.5m upto 2.0m x 2.0m
52All as per item No.49.00 above, but of size above 1.5m x 1.5m upto 2.5m x 2.5m
53All as per item No.49.00 above but of size above 2.5m x 2.5m upto 3.5m x 3.5m
54All as per item No.49.00 above, but of size above 4.5m x 4.5m upto 5.5m x 5.5m
55S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe/duct or fixed to poles or any other indicated situation for loop earthling etc. as required of size 25x4mm galvanised iron strip including taking down unserviceable one all as specified and directed.
56M & L for earthing complete with steel earth plate eletrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GIearth strip 32x6 mm by means of bolts. nuts,check nuts and washers etc including protection pipe 40mm dia up to 7.5m length, provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts, bolts, earthing shall be done all as per shown electrical plate No 3 of SSR part 1 Including neccessary excavation in soft disintergrated rock and provision of 15mm dia pipe with funnel, PCC earth chamber of 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr-in-Charge.
57Dismantling of UNSV enclosure box of any size with switchgear, cables and S & F Electro galvanized steel sheet (corrision resistant) enclosure box having minimum thickness 1.0mm , IP 55,IK 08 with multiple knockout and suitable for installation of4P MCCBs upto rating 200 Amounting on angle iron frameand two legs suitable size of angle iron , properly grouted on floor/wall with anchor fastener including refixing of cables using proper lugs/ glands complete all as specified. (Note: Rate for fixing of MCCBs are incl of contractor quoted rates. MCCB of suitble size will be measured and paid seperately as supply only) Make- L&T / Legrand/ Schenider or equivalent make.
58S & F aluminium perforated sheet silver in colour having round holes (Anti corrosive) having thickness not less than 2mm cut to shape incl bending, moulding as per site reqirement,duly fixed with screws/ locking arrangments for securing of cable on wall/ column/beam more than 3 Mtr height from floor level including refixing of existing loose of LT cable of any size with proper saddles/clamps where reqd complete all as specified and as directed.
59M&L for taking up MS duct cover from cable duct of depth upto 1.5 m and width not exceeding 1.0m in various shop floors/substations, keeping a side for reuse, taking out all cables from the cable duct, removing unused/dead cables from the trench, cleaning of trench by taking out all silt/debries and deposit to nearest garbage bins and relaying of all serviceable cablesall as specified and directed.
60Dismantling structural steel work of any description complete all as specified and directed.
61S&F for rolled mild steel plain or chequered plates confirming to Fe-290, Gde E-165 welded, riveted, bolted attached to supporting structure of capstan, duct covers, valve pit access platform and working in a confined area including making good the disturbed portion of concrete surfaces with 1: 1 1/2 :3 type A0 using 12.5 mm stone aggregate complete all as specified by Engr-in- Charge.
62S&F structural steel framed work such as angle, channel, I beams etc cut to shape, including bending and welding angles as necessary confirming to Fe-290, Gde E-165 as in supporting structure of duct covers, platforms (0 to -3m level) and capstan, ladders framed balusters, walk ways, railing, nosing angle and similar works, including making good the disturbed portion of concrete surfaces with 1: 1 1/2 :3 type A0 using 12.5 mm stone aggregate and all as directed complete all as specified and directed.
63M & L for preparation of new steel surface of any description over 10 cm width or girth andapplyingtwo coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed.
64M & L for preparation of old steel surface of any description over 10 cm width or girth andapplyingone coat of synthetic enamel paint complete all as specified and as directed.