Tender For Comprehensive Maintenance, Upkeep And Operation Of Electro- Mechanical Services Of Te Building And Staff Quarters At Shivpuri Under Ba Gwalior., shivpuri-Madhya Pradesh

Bharat Sanchar Nigam Limited-BSNL has published Tender For Comprehensive Maintenance, Upkeep And Operation Of Electro- Mechanical Services Of Te Building And Staff Quarters At Shivpuri Under Ba Gwalior.. Submission Date for this Tender is 24-11-2023. Electromechanical Services Tenders in shivpuri Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40534002
Corrigendum : Tender For Comprehensive Maintenance, Upkeep And Operation Of Electro- Mechanical Services Of Te Building And Staff Quarters At Shivpuri Under Ba Gwalior.
Open Tender
Indian
Madhya Pradesh
shivpuri
24-11-2023

Tender Details

Tender For Comprehensive Maintenance, Upkeep And Operation Of Electro- Mechanical Services Of Te Building And Staff Quarters At Shivpuri Under Ba Gwalior.; 2 Comprehensive Maintenance Of Following Electromechnical Services As Per The Asset Details, Specification And Conditions Attached And Providing One Semi Skilled Labour For Upkeep, Repair And Operation In General Shift Only. ( A ) E.I. & Fans. ( B ) Compound-Lighting ( C ) Pumps ( D ) Sub-Station ( E ) E. A. Sets ( F ) A.C. System ( G ) Fire Detection System ( H ) Electrical Appliances. 3 A ) Labour Component For Upkeep, Repair And Operation Of Ems ( One Semi Skilled Labour In General Shift Per Month ) 4 B ) Comprehensive Maintenance Of Ems 5 Sh-Ii: Preventive Maintenance And Consumable Items As And When Required On Measurable Basis 6 Servicing & Routine Maintenance ( B Check ) Of Followingcapacity Of Dg Set Complete With Cleaning Of Air Cleaner Element, Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements, Replacement Of Fuel Filter Elements, Retighten Cylinder Head Nuts, Adjust Engine Valve Clearance, Replacement Of Radiator Water By Fresh Distilled Water With Addition Of Coolant Additive Concentrate, Cleaning Of Radiator Fins, Drain Sediments From Water Separator, Check Inlet Air Restriction, Check Air Piping, Belt Tensions I / C Cleaning & Dedusting Of Alternator, Control Panel, Fuel Tank, Tightening & Maintaining Of All Hose Connections, Electrical Connections, Battery Connections Etc & Actual Load Testing Of Dg Set After Servicing Etc As Directed. 7 I ) 125 Kva Dg Sets 8 Supply , Installation, Testing And Commissioning Of 12 Volt, Heavy Duty , Hybrid Alloy Plate, Semi Maintenance Free , Storage Type, Ready To Usebattery Set For Existingdeasetincludingproper Initial Factory Charging Of Unit, Providing And Fixing, Terminal And Thimbles ( If Required ) , Greasing The Battery Terminalscomplete As Required.180 Ah, 12 Volt ( M / S Exide Fxpo-Xp180 Or Equivalent Of Approved Make ) Note-1 ) Agency Shall Consider Rebate For Old Battery While Quoting Of Rates. Additional Requirement To Be Borned By Agency Without Extra Cost. 9 Dehydration / Filtration Of Oil Of Transformer, Ht Panel And Potential Transformer Along With Break Down Voltage Testing Before And After Filtration, Acidity Testing After Filtration, Silica Gel Change Complete As Required.Note1 ) Breakdown Voltage Of Oil After Dehydration / Filtration Shall Be Minimum 60 Kv Rms.2 ) Total Acidity Max After Dehydration / Filtration Shall Be 0.05 Mg Koh / Gm.3 ) Max Water Content After Dehydration / Filtration Shall Be 15 Ppm. 10 Sh-Iii: One Time Maintenance Of Ems Asrequired On Measurable Basis As Per Instruction Of Engineer-In Charge ( For Removal Of Initial Defects In Services ) 11 Replacement Of The Following Faulty / Burnt Electrical Items / Accessories In The Existing Substation And Distribution System, Suitable For Operation On 3 Phase, 33Kv / 415V / 230V, 50Hz, Ac Supply System Including Cleaning Of Installation And Lt Panels And Distribution Boards Etc Complete With Interconnections, Testing And Commissioningas Reqd At Site. 12 630 Amps. Hrc Fuse. 13 Transformer Oil. 14 Acsr Conductor Jumper Up To 3.0 Mtrs. Length. 15 Gang Operated Air Break Switch In The Existing 200 Kva , 33 Kv Outdoor Substation Complete. 16 Threephase Lcd Multifunction Meter Indicating V, A, F, Pf, Power, Energy ( M / S L&Tnova Series, Cat. No. Wm30kfc3c00 Or Equivalent Similar Superior Make With C.TS 17 Led Type Indication Lampswith Suitable Rating Hrc Fuses With Base & Carrier ( Led Ofm / S Esbee L&T, Elr&Y240a - 240V + Elb240a - 240V Ac Or Equivalent Similar Superior Make ) 18 Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required 19 100 Amp Rating, Four Pole, Mccb With Variable Thermal-Magnetic Release, ( Release Range 25-32, 50-63, 80-100A ) Breaking Capacity 25Ka At 415V, 50Hz, Ac Supply And Conforms To Is / Iec 60947-2 ( Make And Model , M / S L&T Dn0-100C Or Equivalent Similar Superior Make ) With ( Ics = 100% Icu ) 20 Repairing Of The Existing Old And Damaged Foundation I / C White Washing Etc. Complete As Required. 21 Painting Of The Existing Ht Poles ( 06 Nos. ) I / C Its Cross Arms / Members Etc. Complete As Required. 22 Earthing With G. I. Earth Plate 600Mmx600mmx6mm Thick Including Accessories And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal / Coke And Salt As Required. ( For Neutral Earthing Of The Existing Transformer ) . 23 Providing And Fixing 25Mmx5mm G. I. Strip In 40 Mm Dia G. I. Pipe From Earth Electrode I / C Connection With G. I. Nut, Bolt, Spring Washer, Excavation And Re-Filling Etc. As Required. 24 Providing And Fixing 25Mmx5mm G. I. Strip On Surface Or In Recess For Connections Etc. As Required. 25 Replacement Of The Following Faulty / Burnt / Damaged Electrical Items / Accessories Suitable For Operation On 230V / 415V, 50Hz, Single / Three Phase Ac Supply , In The Existing Electrical Installation , Fan And Fittingsi / C Supplying Making Interconnections, Testing & Commissioning Etc. Complete As Required:- 26 Electronic Choke For 36 / 40 Watt Fluorescent Lamp . 27 30 Watt Led Lamp With Holder ( For Campus Light ) . 28 1200 Mm ( Nominal ) Size, 40 Watt Fluorescent Tube Rod. 29 2.5 Mfd Condenser ( For Ceiling Fans ) . 30 9 Watt Led Bulb With Holder. 31 20 Watt Led Lamp With Holder ( For Campus Light ) . 32 1200 Mm ( Nominal ) Size, 20 Watt Led Tube Rod 33 6-32 Amps. Single Pole C Curve Mcb. 34 32 Amps. Triple Pole And Neutral Mcb. 35 Starter For 4Feet, 40 Watt Fluorescent Fitting. 36 5 / 6 Amps Piano Type Switch 37 15 / 16 Amp Piano Type Switch 38 3 Pin 5 / 6 Amp Socket Outlet 39 6 Pin 15 / 16 Amp Socket Outlet 40 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator. 41 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required 42 1 X 1.5 Sq. Mm 43 2 X 4 Sq. Mm 44 Supplying And Laying 2X4 Sqmm. Al. Pvc Insulated And Pvc Sheathedunarmoured Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required 45 Repairing / Rewinding Of The Following Faulty Electrical Items / Accessories Complete With Connections, Testing And Commissioning Etc. As Reqd:- 46 Rewinding Of 1200 / 1400 Mm. Sweep Ceiling Fan. 47 Rewinding Of 450 Mm. Sweep Exhaust Fan. 48 Supply, Installation, Testing And Commissioning Of Following Rating And Types Of Prewired Fitting Complete With All Accessories Driver And Lamps Etc., Suitable For Operation On 230 Volts, 50 Hz Single Phase Ac Supply I / C Fixing The Same Directly On Wall / Celling Including Connection With 3X 1.5 Sqmm Frls Pvc Insulated Copper Conductor Flexible Cable Etc As Required. ( M / S. Bajaj / Havells / Philips ) . 49 1200 Mm ( Nominal ) , 20 Watts ( + / - 2 Watts ) Energy Efficient Linear Box Led Batten Light Having 6500K Colour Temp., Minimum 1900 Lumens, 95 Lumen / Watt Efficacy And 0.9 Power Factor . 50 Replacement Of The Old, Life Expired Fittings With The Following Rating And Type Fitting Suitable For Operation On 230Volts, 50 Hz, Single Phase, Ac Supplyi / C Installation The Same On The Existing Bracket On The Wall / Pole, Making Interconnections, Testing, Commissioning Etc As Reqd At Site . ( Preferred Makes Syska / Wipro / Havells / Crompton / Bajaj / Osram Or Similar Superior Make ) . 51 Led Street Light Luminaire Of Nominal Wattage 30W ± 15% With Aluminium Housing & Lens Embedded Pc Cover Having Ip65 Protection. 52 Led Street Light Luminaire Of Nominal Wattage 60W ± 15% With Aluminium Housing & Lens Embedded Pc Cover Having Ip65 Protection. 53 Providing And Fixing Of 300 Mm Sweep, 1400 Rpm Domestic Exhaust Fan Suitable For Operation On 1 Phase, 50 Hertz, 220-230 Volt Ac Supplyin Existing Opening As Reqd. ( Crompton, Bajaj, Havells, Almonard Or S.S.Make ) 54 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 55 Sh-Iii: Pumps & Lt Panels 56 Sitc Of Dol Motor Starter With Overload Protection And Single Phase Preventor , Suitable For Operation Upto 7.5 Hp, 415 Volts, 50Hz, Three Phase, Monoblock Pump Set Having Suitable Rating Contactor, Relay, Voltmeter, Ampere Meter, On / Off Push Button Assembly, Indicators, Connection Plate, Etc. Complete As Required. ( M / S. L&T Mu C6 Dol Starter, Bch Or Similar Superior Make ) . 57 Supplying And Fixing Of 3Ph Led Ammeter Accuracy Class 1.0 And Suitable Rating CtS Complete As Required 58 Supplying And Fixing Of 3Ph Led Ammeter Accuracy Class 1.0. Complete As Required. 59 Sh-Iv: Sac & Pac Units 60 Servicing Of Existing One No 7 Tr Capacity High Precision Air Conditioner Unit With Necessary Dismantling Of Covers Wherever Required, Pressurized Wet Servicing Of Evaporator And Condenser Coil, Cleaning Of Oil Stains If Any, Cleaning Of Evaporator Filters With Water , Checking / Inspection Of All The Electrical Components And Connections For Its Tightness, Checking Of Electrical Parts For Proper Functioning, Checking Out All Controls, Minor Rectification Of Damaged Indoor And Out Door Wiring For Satisfactory Operation Of Package Ac Unit, Including Visit And Inspection Charges Complete In All Respect , Testing And Commissionetc. Complete As Required At Site. 61 Supplying And Top Up Charging Of Fresh Refrigerant R-22 / M-22 / C-407In The Existing Window Ac / Split Ac / Package Ac Units Unitcomplete As Per Manufacturer / Departmental Specifications, Etc As Required At Site.In The Pac No.1 & Sac 62 Carrying Out Wet Servicing Of Existing One Nowindow / Split Type Ac Units Upto 2.0Tr Capacitycomplete With Completecleaning And Washing Of Indoor And Outdoor Units , Cleaning Of Filter, Checking / Inspection Of All The Electrical Components And Connections For Its Tightness, Checking Of Electrical Parts For Proper Functioning, Checking Out All Controls, Minor Rectification Of Damaged Indoor And Out Door Wiring , Providing Necessary Tape And Thimbles, Including Visit And Inspection Charges Complete In All Respect , Testing And Commissionetc. Complete As Required At Site. 63 Supplying And Fixing / Replacement Of Following Electricalitems, Suitable For Operation On 230V / 415 V , Single Phase / Three Phase , 50Hz , Ac Supply In The Existing Faulty Window Ac / Split Ac Units / Package Ac Unitcomplete With Installation, Making Interconnections, Testing And Commissioning Etc.As Required At Site. ( 1.5 Tr Window, 1.5 / 2 Tr Split Ac And 3 Tr Hshf ) ( Note: The Faulty Material / Compressorshall Be Handed Over To The Agency . The Agency Shall Consider Suitable Buyback Pricewhile Quoting For The Item ) A ) Supplying And Fixing Ofrunning Capacitor 50 Mfd 64 Repairing Of The Following Faulty Components Ofexisting Split / Window Type Ac Units Including Dismantling , Repairing , Replacement , Reinstallation And Labour Charges Complete In All Respect For The Same, Making Interconnection, Testing And Commissioning Etc As Reqd At Site. 65 Rewinding Of Condenser Fan Motor Of 1.5 / 2 Tr Split Ac 66 Sh-V: Fire Detection System & Fire Extinguishers 67 Repairing Offollowing Zone , Existing Fire Detection Control Panel I / C Cleaning , Repairing Of Zonal Cards, Mother Board, Control Card, Charging System, Replacement Of The Faulty / Burnt Diodes, Integrated Circuits, Leds And Power Supply Unit Etc. Complete With Testing As Required. 68 10 Zones Main Control Panel. 69 4 Zones Local Control Panel. 70 6 Zones Local Control Panel. 71 Supplying, Installation, Testing & Commissioning Of Following Type Fire Detectors And Other Accessories In The Existing Fire Detection And Alarm System Completewith All Connections Etc. As Required. 72 Smoke Detector With Built In Led And Mounting Base Complete. 73 Dual Chamber Heat Detector ( Heat Cum Rate Of Rise In Temperature Type ) . 74 Responseindicator On Surface / Recess Ms Box Having Two LedS And Metallic Cover Complete.. 75 Manual Call Point ( Pill Box ) Of Ms Construction With Stainless Steel Chain And Hammer Assembly. 76 Fire Alarm Sounder With Facility To Make Announcement Mounted In Ms Box ( 16 Swg ) With Hinged Cover Plate. 77 Cleaning Of The Entire Existing Detectors Installed In The Bldg. I / C Testing Etc. Complete As Required. 78 Refilling / Recharging Of The Following Type / Capacity Fire Extinguishers As Per Bis 2190:2010 Specifications Including Repair Of Fire Extinguishers And Replacement Of Defective Spare Parts Like Nozzle, Safety Clip, Horn, Water, Rings, Washer, Plunger Etc. As Required And Collection, Transportation And Delivery Charges From Various Exchanges To Refilling Station And Vice Versa Etc. Complete As Required: 79 4.5 Kg. Portable Co2 Type Fire Extinguisher.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Nov-2023 Corrigendum Shivpuri Date 24-11-2023

Key Value

Document Fees
INR 590 /-
EMD
INR 8698.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail