Tender For Repairs/ Maintenance Of Internal Electric Supply, Light Fittings, Mcbs, Dbs Garden Light Fittings And Connected Works In Md Accn And Otm Accn At Nad Bheemunipatnam, Repairs/ Maintenance Of Ceiling Fan, Wall Mounted Fan, Electric Geysers, Electr, visakhapatnam-Andhra Pradesh

Military Engineer Services-MES has published Tender For Repairs/ Maintenance Of Internal Electric Supply, Light Fittings, Mcbs, Dbs Garden Light Fittings And Connected Works In Md Accn And Otm Accn At Nad Bheemunipatnam, Repairs/ Maintenance Of Ceiling Fan, Wall Mounted Fan, Electric Geysers, Electr. Submission Date for this Tender is 17-11-2023. Tube Light Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40501879
Tender For Repairs/ Maintenance Of Internal Electric Supply, Light Fittings, Mcbs, Dbs Garden Light Fittings And Connected Works In Md Accn And Otm Accn At Nad Bheemunipatnam, Repairs/ Maintenance Of Ceiling Fan, Wall Mounted Fan, Electric Geysers, Electr
Open Tender
Indian
Andhra Pradesh
visakhapatnam
17-11-2023

Tender Details

Repairs / Maintenance Of Internal Electric Supply, Light Fittings, Mcbs, Dbs Garden Light Fittings And Connected Works In Md Accn And Otm Accn At Nad Bheemunipatnam, Repairs / Maintenance Of Ceiling Fan, Wall Mounted Fan, Electric Geysers, Electric Meter, Solar Water Heater And Connected Works At Nad Bheemunipatnam Visakhapatnam Under Ge ( P ) Navy Kalinga

Key Value

Document Fees
INR 500 /-
EMD
INR 47000.0 /-
Tender Value
INR 23.50 Lakhs /-

BOQ Items

Name of Work : REPAIRS/ MAINTENANCE OF INTERNAL ELECTRIC SUPPLY, LIGHT FITTINGS, MCBS, DBS GARDEN LIGHT FITTINGS AND CONNECTED WORKS IN MD ACCN AND OTM ACCN AT NAD BHEEMUNIPATNAM, REPAIRS/ MAINTENANCE OF CEILING FAN, WALL MOUNTED FAN, ELECTRIC GEYSERS, ELECTRIC METER, SOLAR WATER HEATER AND CONNECTED WORKS AT NAD BHEEMUNIPATNAM VISAKHAPATNAM UNDER GE (P) NAVY KALINGA
Sl. No. Item Description
1Taking down carefully existing aluminium conductor point wiring (light / fan / socket or power point) complete, with all fittings such as switches, socket, regulator, ceiling rose, utility light fittings and lamp holders etc and removing materials from site and making good the disturbed surfaces of walls roof and floor etc as per existing specification complete all as specified and as directed.
2Taking down carefully by unscrewing from boards / outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and fan regulators etc. for reuse at site complete all as specified and as directed. (Note : To be measured only when found serviceable in all respects complete for reuse)
3Material and labour for point wiring for one light controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn carefully through existing/New concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminatedfor mountingswitches, sockets, fan regulators etc including testing on completion complete including making good disturbed surface all as specified and as directed.
4All as per Item no 3 here-in-before but for one light point controlled by two 2 way switch all as specified and as directed.
5All as per Item no 3 here-in-before but for one fan point controlled by 1 one way switch and regulator all as specified and as directed.
6All as per Item no 3 here-in-before but for one switch socket outlet, 5 Amp on same board with other switches all as specified and as directed
7All as per Item no 3 above but for one 3 pin switch socket outlet, 5 Amp on independent board all as specified and as directed.
8All as per Item no 3 here-in-before but for one16 Amp 3 & 5 pin switch socket outlet, independent with 4 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 4 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed.
9All as per Item no 3 here-in-before but for one bell point controlled by one bell push on the same board with other switches or independent all as specified and as directed.
10Material and labour for point wiring for one light controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn carefully through Existing /New pvc casing capping along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including new pressed steel sunken boxes ,concealed type with 2 mm thick bakelite sheet cover for mounting switches, etc including testing on completion complete including making good disturbed surface all as specified and as directed.
11All as per Item no 10 here-in-before but for one light point controlled by two 2 way switch all as specified and as directed.
12All as per Item no 10 here-in-before but for one fan E/ Fan point controlled by 1 one way switch and regulator all as specified and as directed.
13All as per Item no 10 above but for one 3 pin switch socket outlet, 5 Amp on independent board all as specified and as directed.
14All as per Item no 10 here-in-before but for one switch socket outlet, 5 Amp on same board with other switches all as specified and as directed
15All as per Item no 10 here-in-before but for one16 Amp 3 & 5 pin switch socket outlet, independent with 4.0 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 4.0 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed.
16All as per Item no 10 here-in-before but for one bell point controlled by one bell push on the same board with other switches or independent all as specified and as directed.
17Supply and fixing switch piano flush button single poleone way 5 amps all as specified and as directed.
18Fixing only switch flush button single pole one way 5 ampall as specified and as directed. (Note : Material obtained from item No 2 here in before shall be reused)
19Supply and fixingsocketcombination 2 in 1 3 pin 5 amp flush type universalall as specified and as directed.
20Fixing only switch socket outlet 5 amp flush type all as specified and as directed. (Note : Material obtained from item No 2 here in before shall be reused)
21Supply and fixingsocketcombination 2 in 1 3 pin 5 and 15 amp flush type universalall as specified and as directed.
22S&F switch flush type, single pole Two way 5 Amps 230 voltsall as specified and as directed.
23Supply and fixing ceiling rose surface bakelite three terminals all as specified and as directed.
24Fixing only ceiling rose surface bakelite three terminals all as specified and as directed. (Note : Material obtained from item No 2 here in before shall be reused)
25Supply and fixing fan regulator electronic deluxe rotary step type all as specified and as directed.
26Fixing only fan regulator any type all as specified and as directed. (Material obtained from item No 2 here in before)
27Material and labour for bell ding dong AC 230 volt single pole all as specified and as directed
28Supply and fixing bell push, flush type 6 amps all as specified and as directed.
29Supply and fixing indoor luminaire decorative batten for wall/ceiling mounting box type with polycarbonate housing & integrated electronic driver energy efficient saving LED BATTEN LIGHT 10 W, 230 V, 50 HZ, install incl twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed.
30Supply and fixing indoor luminairedecorative batten for wall/ceiling mounting box type with polycarbonate housing & integrated electronic driver energy efficient saving LED BATTEN LIGHT 20W, 230 V, 50 HZ,incl twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed.
31S&F 10 W LEDdecorative CITY 3 wall/surfacemountingpolycarbonatebody suitable forretrofit LED Lamp Base B-22 incl lamp ,all as specified and as directed (Make Havells Cat Part No. LHDL06160099 or equivalent as approved by GE)
32Supply and fixing lamp holder insulated body suitable for Retrofitlampall as specified and as directed.
33Supply and fixing 9 W LED lamp 4 starsuitable for Retrofit LED fitting all as specified and as directed. (Make : Havells Cat No. LHEDEUECNL8R009 or equivalent as approved by GE)
34Supply and fixingLED bulk headfittings 10W,230 V,50 HZ suitable for indoorapplications completeall as specified and as directed.
35Supply and fixingLED mirror light fittings 07 W,230 V,50 HZ suitable for indoorapplications completeall as specified and as directed.
36Supply and fixing on wall security LED light luminaire fitting 1X25 W and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1.5 m long bent to shape including bolt, nut,washer,clamp etc all as specified and as directed by the Engineer-in-charge.
37Material and labour for sub main wiring with Four single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4.0sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4.0sqmm as in continuous earth wire drawn into andExisting/ New , concealed/surfacePVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete withincluding taking down old unserviceable sub main wiring and cutting chases pinning and making good disturbed surface complete all as specified and as directed. NOTE: 5 runs of 4 Sqmm and one run of PVC conduit 25mm diawill be measured as one unit i.e. RM
38Material and labour for sub main wiring with Four single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6.0sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6.0sqmm as in continuous earth wire drawn into andExisting/ New , concealed/surfacePVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete withincluding taking down old unserviceable sub main wiring and cutting chases pinning and making good disturbed surface complete all as specified and as directed. NOTE: 5 runs of 6 Sqmm and one run of PVC conduit 25mm diawill be measured as one unit i.e. RM
39Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with taking down old unserviceable submain wiring and including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends and making good disturbed surface complete all as specified and as directed. NOTE: 3 runs of 6 Sqmm and one run of PVC concealed conduit 25mm diawill be measured as one unit i.e. RM
40Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with taking down old unserviceable submain wiring and including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends and making good disturbed surface complete all as specified and as directed. NOTE: 3 runs of 4 Sqmm and one run of PVC concealed conduit 25mm diawill be measured as one unit i.e. RM
41Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with taking down old unserviceable submain wiring and including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends and making good disturbed surface complete all as specified and as directed. NOTE: 3 runs of 2.5 Sqmm and one run of PVC concealed conduit 25mm diawill be measured as one unit i.e. RM
42Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with taking down old unserviceable submain wiring and including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends and making good disturbed surface complete all as specified and as directed. NOTE: 3 runs of 1.5 Sqmm and one run of PVC concealed conduit 25mm diawill be measured as one unit i.e. RM
43Supply and fixing in repair sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , Triple Pole and Neutral (TPN), suitable for 4 way, Double door 415 Volts all asincl taking down old u/s specified and as directed .
44Supply and fixing in repair sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8 way with din rail earth and neutral bar all as specified and as directed.
45Supply and fixing in repair sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 4 way with din rail earth and neutral bar all as specified and as directed.
46Supply and fixing in repair MCB FourPole (FP) C curve 10kA breaking capacity of63 amps, 415 Volts in proper position all as specified and as directed.
47S&F in repair in proper position MCB Double Pole of capacity up to 40 amps, 240 Volts c-series with 10kA breaking capacityall as specified and as directed.
48Supply and fixing in repair MCB Single Pole (SP) C curve 10kA breaking capacity of6 to 32 amps, 240 Volts in proper position all as specified and as directed.
49S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and as directed.
50Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium Strandedconductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core 4 Sqmmcable flat or circular incl taking down old u/s all as specified and as directed..
51Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium Strandedconductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core 6 Sqmmcable flat or circular incl taking down old u/s all as specified and as directed .
52Supply & Fixing in repairs MS Box in concealedof any type and size
53S&F in repairs PVC /bakelite sheet 3 mm thick of size 8" x 11" including cuttings of sheet for fixing switch /socket etc complete all as specified and as directed.
54All as per ser item No. 53 above but size of sheet 8" x 5"
55All as per ser item No. 53 above but size of sheet 4" x 4"
56Supply and fixingin Repair switch piano flush button single poleone way 5 amps with taking down old unserviceable one all as specified and as directed .
57Supply and fixing in Repairswitch socketCombination 2 in 1,3 pin5 amp flush type with taking down old unserviceable oneall as specified and as directed .
58Supply and fixing in Repairswitch socketCombination 2 in 1,3 pin 15 amp flush type with taking down old unserviceable oneall as specified and as directed .
59Supply and fixing in Repairfan regulator electronic deluxe rotary step /switch type with taking down old unserviceable oneall as specified and as directed.
60Supply and fixing LED lamp7/ 9 Watt in repairs of existing lamp fitting any type and size all as specified and as directed.
61Taking down unserviceable 40 W FTL fitting /20 Watt LED and repair/replacement of old unserviceable spare with new spares, re-assembling and re fixing in existing position and connecting with existing point all as specified and as directed by the engineer-in-charge. Note : Accessories/spare parts required for replacement will be measured and paid separately againstitem no 62 to 65.
62Supplyonly indoor luminaire decorative batten for wall/ceiling mounting box type energy efficient saving LED BATTEN LIGHT 10 W, 230 V, 50 HZ, slim integrated design easyinstall incl twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed. (Make: Bajaj Cat Part No.BCLSB 10 NW or equivalent as approved by GE)
63Supply only indoor luminairedecorative batten for wall/ceiling mounting box type Extruded aluminiumhousing , PC diffuser, energy efficient saving LED BATTEN LIGHT 20W, 230 V, 50 HZ, slim integrated design easy installincl twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed. Make :Bajaj Cat Part no. BCLSB 18 NW or equivalent as approved by GE
64Supply only20 W decorative batten for wall/ceiling mountingbatten suitable for T- 8 LEDTube, installincl twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed.
65Supply only 18/20 W LED Master tube light.
66Supply and fixing in Repairupto 36/42 WLED Power Driver for Downlightersall as specified and as directed.
67Supply and fixing in Repair Upto 18WLED Power Driver for Downlightersall as specified and as directed.
68S&F in RepairRecess Mounting luminariesLED downlighter of 12 W white in the shape of Square typecomplete , all as specified and as directed .
69S&F in RepairRecess Mounting luminariesLED downlighter of 36 W white in the shape of Square 2" x2" feet complete , all as specified and as directed.
70S&F in RepairRecess Mounting luminariesLED Panel fitting 36 W4" x 1" feet complete , as per existing modelall as specified and as directed.
71Taking down post top lantern /Gate light any type for repair and refixing the same on its existing position after necessary repair work. Note :- (i) Spares required will measured and paid under separate item No. 72 to 74 here in after (ii) Labour cost for replacing spare partsto be inclusive in the quoted rate .
72Supplyonly outdoor integralLED Bollardluminaire10wattwith soft 360 deg lightdistribution copper conductor flexible wire from busbar to connector all as specified and as directed. Make:CG Cat Part No. LBLSN-10-CDLor equivalent as approved by GE
73Supplyonly outdoor integral decorativepost top lantern luminaire 40 w LED, IP 65 protectionand three core twisted copper conductor flexible wire from busbar to connector all as specified and as directed. Make:CG Cat Part No. LPTO-40-CDLor equivalent as approved by GE
74Supplyonly outdoor integral decorativepost top lantern luminaire 20 w LED, IP 65 protectionand three core twisted copper conductor flexible wire from busbar to connector all as specified and as directed. Make:CG cat Part No. LPTH-20-CDL or equivalent as approved by GE
75Supply, fixing in Repairand cable junction boxes of size 155mm x 210mm x 92mm IP 66for cable entry, comprising of SPN aluminium bus bar of capacity 16 Amp 230 Volt fixed , making holes on strips for connecting cables and fixed to gardenlight pole with and including MS clamp of size 25mmx5mm incl nut ,bolt, washer andincluding prvn of MCB SP 6 A, C curve 10kA breaking capacity with mounting rail all as specified and as directed.
76M&L for checking the serviceability including loose contact and condition of cable terminations of all the existing MCB DBs at any building/any place once in three months and opening a DB serviceability register and recording building wise including obtaining rep of users signature in the register complete all as specified and as directed. Note:- The checking shall be carried out in presence of user/user rep. One time checking including entering in the register is considered as one job.
77Supply and fix in repair 1x120 W LED flood light new generation high luminous efficiency, with channel, MS clamp, nuts, bolts washer etc. including taking down old unserviceable one complete all as specified and as directed.
78Supply and fixing AC Single phase static Electronic KWH energy meter of accuracy class 1.0, 240v, 50 Hz , with Backlite LCD display ,optical port of rating 10-60 amp 06 months history with transparent hinge type box ,incl taking down old u/s kept in MES store all as specified and as directed.
79M&L for Earthing complete with 3 m CI pipe 80 mm dia with flanged ends, centrifugally cast, class A, in any length, joints with suitable stainless steel nuts and bolts and sufficient slot up to 2.5mtrs length buried directly and preferably vertically in ground with top flanged ended 2.5mtrs below ground label welded/connected with GI strip 32×6mm size on the top edge of the flange to bottom edge of the flanged for earthing including filling the pit with charcoal common salt surrounding the earth pipe including drilling 400 mm dia bore in any strata of soil to lower the CI pipe complete including necessary excavation and earth work PCC(1:3:6) type C-1 with 50 mm thick pre cast RCC (1:2:4) type B-1 cover slaband necessary testing on completion complete all as specified and as directed ..
80Checking of ceiling fan 1200mm sweep at site when and where required asMES complaint slip on daily basis if required excepting Sunday and holidays in existing position including Supply and fixing as replacement at site in position ceiling fan capacitors 2.5 mfd all as specified and as directed .
81All as per item No. 80 above but ceiling fan 1400mm sweep when and where required asMES complaint slip on daily basis if required excepting Sunday and holidays and ceiling fan capacitor 3.15 mfd all as specified and as directed
82Taking down carefully existing ceiling fan of any sweep and any make after disconnecting the electrical connections, dismantling the blades and removing fan including blades to the workshop including cleaning and dismantling the fan into parts and segregation of unserviceable parts, replacement of unserviceable spare parts with new parts including necessary machining works and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan complete and testing and refixing the fan in same position including all electrical connections and material and labour for replacement of two nos split pins, one connection block and one rubber reel complete all as specified and as directed. Note:- (i) Rewinding work of armature (if any) shall be measured and paid separately (ii) New spare parts required for replacing old burnt out parts other than connector, split pins, connection block and rubber reel shall be measured and paid separately under relevant item as supply only. (iii) Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate of item No. 82.00
83Taking down carefully existing exhaust fan any sweep and any make after disconnecting the electrical connection, and removing the exhaust fan with blade to the work shop including cleaning of dust and dismantling the fan into parts and segregation of unserviceable parts, replacement of unserviceable spares parts with new parts including necessary machining work and lubricating with approved grade of grease and necessary minor soldering work (if required)re-assembling the fan complete , testing and refixing the fan in same position including all electrical connection and material and labour for replacement of one connection block all as specified and as directed. Note : i) Rewinding work (if any) shall be measured and paid separately ii) New spare parts required for replacing old worn out parts other than connector, shall be measured and paid separately under relevant item as supply only. iii) Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate of item No. 83
84Taking down and refixing after repairs, air circulator/pedestalfan of any make/ model and sweep in its original position, connecting and testing complete all as specified and as directed by the Engineer-in-charge.
85Taking down and refixing after repairs, wall mounted fan of any make/ model and sweep in its original position, connecting and testing complete all as specified and as directed by the Engineer-in-charge.
86Taking down and refixing after repairs, FLP Ceiling fan/Wall mounted /Exhaustfan of any make/ model and sweep in its original position, connecting and testing complete all as specified and as directed by the Engineer-in-charge. Note for Item Nos.84 to 86: Bearing/gun metal bush/rubber bush & bolts/ capacitor/rewinding/cord flexible/shaft etc. will be measured and paid separately.
87Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for 1200mm sweep fan with new super enamelled copper wire of existinggauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
88All as per item No. 87above but for 1400mm sweep ceiling fan all as specified and as directed.
89All as per item No. 87 above but exhaust fanup to 300mm sweep.
90All as per item No. 87 above but exhaust fan up to 400/450mm sweep.
91All as per item No. 87 above but wall mounted up to 400/450mm sweep.
92All as per item No. 87 above but air circulator//pedestal fans 450mm sweep.
93All as per item No. 87 above but flame proof ceiling fan 1200/ 1400mm sweep.
94All as per item No. 87 above but flame proof exhaust fan 400/ 450mm sweep.
95All as per item No. 87 above but flame proof wall mounted/ air circulator fan 400/450mm sweep.
96Supply only bearing No.6201/6202 for ceiling /Exhaust fan
97Supply only bearing No.6203/6204 for ceiling/ Exhaust fan
98Supply only fan capacitor 2.5 mfd .
99Supply only fan capacitor3.15 mfd .
100Supply only gun metal bush of any size
101Supply only mounting clamp assembly complete for ceiling fan 1200mm/1400mm sweep with amp,bolt,nut,washers, safety/ split pins and rubber bush and all as specified and as directed.
102Supply only down rod assembly complete for ceiling fan 1200mm/1400mm sweep all as specified and as directed.
103Supply and fixing modular step fan speed regulator 120 w ,2 module all as specified and as directed.
104Material and labour for painting of ceiling fans complete of any sweep/make with one coat of firstquality synthetic enamel paint of approved tint by spray including preparation of old painted surface and removing all dust, oil mark etc and filling cavities with filler materials, and writing serial / MES number as specified (with paint of black colour with each letters/ figures in Block of height n.exc 2 cm ) completeall as specified and as directed.
105All as per item no. 104 above but for painting to exhaust fans with blade complete of any sweep/ make all as specified and as directed.
106Supply and fixing in replacement louvers shutters for Exhaust fan of any size up to 450 mm sweep suitable for any make made of MS sheet including two coat of synthetic enamel paint over a coat of red oxide and bolt,nut,washers etc complete including taking down old unserviceable one all as directed by Engineer-in-Charge.
107Supply and Fixing flexible copper conductor three core 1.5 Sqmm PVC insulated sheathed 1100 V grade complete all as specified and as directed by the Engineer-in-Charge.
108M&L for comprehensive repair/ maintenance of storage type electric water heater (geyser) vertical or horizontal type of capacity 25 ltrs comprising of the following :- (a) Inspection, taking down, opening or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank upto the satisfaction of the Engr-in-Charge. (b) Checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc in situ to ensure free movement of the parts including supply and replacing then washers/ gasket nut etc. (c) Checking and rectifying earth continuity of the electrical circuits of the geyser and power point. (d) Checking and refixing thermostat and re-adjust (e) De-scaling the immersion type heating element and siphon assembly with diluted hydro chloric acid or clear pedette solution. (f) Checking of indicator lamp for its serviceability (g) Re-assembling the Geyser, re-install and testing complete. Note : Parts/ components of geysers found unserviceable shall be replaced by the contractor. New parts/ components required shall be measured and paid separately under Item No. 110 to 119 here-in-after as supply only and labour charges required for replacement are deemed to be included in the quoted rate of item No. 108
109Comprehensive repair/maintenance of solarwater heater (Geyser )horizontal type of capacity 100/500Ltrs comprising of the following :- (a) Inspection, taking down , opening or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank up to the satisfaction ofthe Engineer-in-charge. (b) checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc. in situ to ensure free movement of the parts including supply and replacing the washers/gasket nut etc. (c)Checking, and re-fixing solar Flat Plate collector/ tube collectorand re-adjust. (d) De-scaling the immersion type heating element with diluted Hydro chloric acid or clear pedette solution. (e) Re-assembling the solar water tank ,solar water tube collector/ flat plate collector, re-install and testing complete. Note : Parts / components of geysers found unserviceable shall be replaced by the contractor. New parts/components required shall be measured and paid separately under item No 110 to item No 119 here-in-after as supply only and labour charges required for replacement are deemed to be included in the quoted rate ofitem no. 109
110Supply only thermostat of Type EST11 / 20A, 250Volt of approved make and having ISI mark all as specified.
111Supply only thermostat of Type EST 7 / 15 A ,250 Volt approved make and having ISI mark all as specified.
112Supply only heating elements of capacity 2 KW AC 240 volts suitable for storage type electric water heater as per site requirement (press type /screw type/triangular/circular base or ceramic cartage type),ISI marked all as specified and as directed.
113Supply only heating elements of capacity 2/3KW AC 240 volts suitable for storage type solarwater heater as per site requirement (press type /screw type/triangular/circular base or ceramic cartage type),ISI marked all as specified and as directed.
114Supply only heating element of capacity 1.5 KW AC 240 volts ISI make and as per sample
115Supply only copper siphon assembly suitable for 25ltr capacity geysers any make as required at site of approved make complete with inlet and outlet and provision for thermostat pipe with drain pipes with drain plug, screws, studs, clamps for fixing heating elements etc. including gasket all as specified and as directed
116Supply only plug top 3 pin, 16 amps
117Supply only PVC insulated PVC sheathed flexible round stranded copper wire 2.5 sqmm, 3 core
118Supply only indicating lamp LEDNeon type, 240 volt AC suitable for 25/50 ltrs capacity Geysers all as specified and as directed
119Supply only safety valve suitable for 25 Ltr/50 Ltr geyser all as specified and as directed.
120S&F earth plug socket with MCB DP 20 Amps including taking down old unserviceable one complete all as specified and as directed.
121S&F plug top earth plug socket upto 20 Amp C-Curve including taking down old u/s one
122Material and labour for tracing and arresting of leakage in storage tank of 25 ltrs capacity Geysers by brazing and soldering at leakage point and testing on completion to the entire satisfaction of Engr-in-charge.
123Taking down Geyser of capacity25 ltrs from its existing position after disconnecting inlet and outlet water connection including material and labour for spray painting to Geysers with one coat of Ist grade synthetic enamel paint of approved tintafter preparation of old steel surface including writing serial / MES number as specified (with black colour paint with each letters/figures(in Block) of height n.exc 2 cm ) and refixing the Geysers to its existing position on completion of painting including making inlet/outlet water connection and testing complete all as specified and directed.
124S&F in repair PVC connection pipe with two brass adaptors 450mm long & fixing in position including taking out old unserviceable one complete all as specified and as directed.
125Supply and fixing chromium plated connecting pipe for hot water of length upto 60cm long, including two brass connecting nut with gasket and connecting up complete including taking out old one all as specified and as directed.
126Supply and fixing non return valve 15mm bore as in replacement of old one and connection complete all as specified and as directed.
127Supply and fixing anchor bolt of size 10mm dia and 100mm long bolt including ,nut,washer for mounting the geyser all as directed.
128Supply and fixing in repairs water heater (Geyser) storage type 5 star rated AC 230 Volts of capacity 25 litres with Grounding of 4 Nut and Bolts and connecting pipe for outlet and inlet water from geyser completeincl taking out old u/s kept deposit in MES storeall as specified and as directed.
129S&F MS ceiling fanMS hook suitable length all as specified and as directed.
130Supply and fixing in repairs ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. five star energy efficient saving rated with brushless direct current motor (BLDC) with clamp and hook at proper position, necessary accessoriesetcincl taking out old u/s kept deposit in MES store all as specified and as directed.
131S&F wall mounted air circulator fan PVC body 400 mm sweep 230 volt, SP complete with accessories incl taking out old u/s kept deposit in MES store all as specified and as directed. (Cat Part No. Turbo force of Havells or equivalent as approved by GE)
132Supply and fixing in repairsPedestal fans400 mm sweep PVC body230 v SP complete with accessories incl taking out old u/s kept deposit in MES store all as specified and as directed.
133Supply and fixing in repairsPVC Exhaust fan of Size 250 mm sweep, 230 volt Acwith connection from existing ceiling rose with Louver Shutterincl taking out old u/s kept deposit in mes store all as specified and as directed .
134Supplyand fixing in repairs Exhaust fan metal bodyheavy duty with louver shutter of sweep 300 mmsweep 230v SP 1400 rpmwith all nut bolt and other accessories withcutting a hole and making good after fixing of Exhaust fan taking out old u/s kept deposit in MES store all as specified and as directed.
135S&F Exhaust fan metal bodyheavy duty with louver shutter of sweep 450 mmsweep 230v SP 1400 rpmwith all nut bolt and other accessories withcutting a hole and making good after fixing of Exhaust fan incl taking out old u/s kept deposit in MES store all as specified and as directed .
136Supply and fixing in repairs AC Three phase static Electronic KWH energy meter of accuracy class 1.0, 240 volt, 50 Hz , with Backlite LCD display of rating 10-60 amp six months history incl taking out old u/s kept deposit in MES storeall as specified and as directed.