Tender For Replacement Of Defective Switch, Socket, Sheets Etc. In The Vacant Flat No. C-11, C-12, C-15, C-16, C-17, C-18, C-19, C-20, C-57 C- Type Flats And Other Allied Minor Electrical Work In Various C-Type Flats At Dhaka Complex, University Of D, Delhi-Delhi

Delhi University has published Tender For Replacement Of Defective Switch, Socket, Sheets Etc. In The Vacant Flat No. C-11, C-12, C-15, C-16, C-17, C-18, C-19, C-20, C-57 C- Type Flats And Other Allied Minor Electrical Work In Various C-Type Flats At Dhaka Complex, University Of D. Submission Date for this Tender is 09-11-2023. Electrical Maintenance Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

40497904
Tender For Replacement Of Defective Switch, Socket, Sheets Etc. In The Vacant Flat No. C-11, C-12, C-15, C-16, C-17, C-18, C-19, C-20, C-57 C- Type Flats And Other Allied Minor Electrical Work In Various C-Type Flats At Dhaka Complex, University Of D
Open Tender
Indian
Delhi
Delhi
09-11-2023

Tender Details

Replacement Of Defective Switch, Socket, Sheets Etc. In The Vacant Flat No. C-11, C-12, C-15, C-16, C-17, C-18, C-19, C-20, C-57 C- Type Flats And Other Allied Minor Electrical Work In Various C-Type Flats At Dhaka Complex, University Of Delhi; 1 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required.Group B 2 S / F The Following Size / Modules G.I Box Along With Modular Base And Cover Plate For Modular Switches In Recess Etc As Reqd. 3 1 Or 2 Module 4 3 Module 5 6 Module 6 8 Module 7 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 8 5 Amps Switch 9 5 Amp Socket 10 15Amps Switch 11 15 Amp Socket 12 Bell Push 13 Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 14 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection Etc. As Required. 15 Supplying And Fixing Brass Batten / Angle Holder Including Connection Etc. As Required. 16 Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box / Wooden Block Including Connection Etc As Required. 17 Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. 18 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 2+ 12 Way, Double Door 19 Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 20 Single Pole 21 Single Pole And Neutral 22 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 23 1 X 1.5 Sq.Mm 24 2 X 2.5 Sq.Mm 25 2 X 4 Sq.Mm 26 2 X 6 Sq.Mm 27 Supplying And Fixing Of Following Sizes Of Heavy Duty Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Mm 28 Supplying And Fixing Suitable Size G.I. Box With Modular Plate And Cover In Front Or In Recess Including Providing And Fixing 25A Modular Socket Outlet And 25A Modular Sp Mcb C Curve Including Connections, Painting Etc. As Required. 29 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2 X 10 Sq. Mm + 1 X 10 Sq. Mm Earth Wire 30 S / F Of 9 Watts Led Bulb With Suitable Brass Holder I / C Making Connection As Required. 31 S / F Of Singlebox Type Fitting Complete With All Accessories I / C Making Connection Etc As Reqd.Tmc 501 1Xt - Led 22W P3242 I / C Having 1 Nos Of Stellar 20 Watt Led Tubelight In The Existing Fitting As Reqd. ( Philips ) 32 S / F Of Led Fancy Light Fitting Complete With All Accessories On Surface As Approved By Engineer-In Charge I / C Making Connection As Required. ( Philips Make ) Comet Model 33 S / F Of 20 Watts Stellar Bright Led Tubelight Having 2100 K Lumens In The Existing Fitting I / C Making Connection Etc. As Required. 34 S / F Of 1200 Mm Dia. Heavy Duty Ceiling Fan Complete With All Accessories I / C Making Connection Etc. As Required. 35 Dismantling The Existing Accessories And Depositing The Same At Engineering Store.

Key Value

Document Fees
INR 500 /-
EMD
INR 9910.0 /-
Tender Value
INR 4.95 Lakhs /-

BOQ Items

Name of Work:Replacement of defective switch, socket, sheets etc. in the vacant flat no. C-11, C-12, C-15, C-16, C-17, C-18, C-19, C-20, C-57 C- Type flats and other allied minor electrical work in various C-Type flats at Dhaka Complex, University of Delhi
Sl. No. Item Description
1Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required.Group B
2S/F the following size/modules G.I box along with modular base and cover plate for modular switches in recess etc as reqd.
31 or 2 Module
43 Module
56 Module
68 Module
7Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
85 amps switch
95 amp socket
1015amps switch
1115 amp socket
12Bell Push
13Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
14Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
15Supplying and fixing brass batten/ angle holder including connection etc. as required.
16Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
17Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
18Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)2+ 12 way, Double door
19Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
20Single pole
21Single pole and neutral
22Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
231 x 1.5 sq.mm
242 x 2.5 sq.mm
252 x 4 sq.mm
262 x 6 sq.mm
27Supplying and fixing of following sizes of Heavy duty PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
28Supplying and fixing suitable size G.I. box with modular plate and cover in front or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including connections, painting etc. as required.
29Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 10 sq. mm earth wire
30S/F of 9 watts LED bulb with suitable brass holder i/c making connection as required.
31S/F of singlebox type fitting complete with all accessories i/c making connection etc as reqd.TMC 501 1XT - LED 22W P3242 i/c having 1 Nos of stellar 20 Watt LED tubelight in the existing fitting as reqd. (Philips)
32S/F of LED fancy light fitting complete with all accessories on surface as approved by Engineer-in Charge i/c making connection as required. (Philips make ) Comet Model
33S/F of 20 watts stellar bright LED tubelight having 2100 K lumens in the existing fitting i/c making connection etc. as required.
34S/F of 1200 mm dia. Heavy duty ceiling fan complete with all accessories i/c making connection etc. as required.
35Dismantling the existing accessories and depositing the same at Engineering Store.