Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-11-2023 | Date Corrigendum | Date | 20-11-2023 |
| Sl. No. | Item Description |
| 1 | Accessibility Retrofitting items - annexure A |
| 2 | Acrylic tactile audio map |
| 3 | Design, supply, fabrication and fixing of acrylic, non glare, tactile audio pictorial building layout as per the approved size, design and make, having 6mm thick acrylic non glare base plate of the approved colour and non glare acrylic cut out symbols and upper case Sans Serif letters of 12mm height, raised 3mm above base plate and Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. The map to be installed at the specified location as per accessibility standards, shall be oriented to the position of the viewer and to be installed at a height of 800 mm from the finished ground/ floor level and using the necessary hardware specified by the manufacturer and to be installed up to the satisfaction of the engineer in charge |
| 4 | Directional signage |
| 5 | Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6\" x 9\" designed as per accessibility standards and having 4mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate and having a non glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200mm from FFL and as per the directions by the engineer in charge. |
| 6 | Floor Directories Providing and fixing acrylic multilingualBraille (raised dots)ADA compliant modular floor directories system on all floors of size1.5\" x 2\" , showingthe floor plan and the list of rooms on that floor, to be installed on each floor near the staircase, designed as per standards and having 4mm thick blue acrylic base plate with Upper Case San Serif words and symbols made of white acrylic non glare cut out letters of height 20mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare imported acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. Each directory to be fixed as per manufacturers specifications on the wall at the approved location at a height of 1200mm from FFL and as per the directions bythe engineer in charge. |
| 7 | Providing an ADA compliant Disability Service Desk havinga lowered portion (800mm from FFL) and leg space of 450 mm, having the approved design and of the approved make as per manufacturers specifications |
| 8 | Providing and fixing Braille indicators for handrails of theapproved design and make having Braille dots raised 0.5mm above base plate, to be installed at the specified locations as per the directions of the engineer in charge |
| 9 | Providing and fixing stainless steel (Grade 304) railingmade of hollow tubes, channels, plates etc. including welding grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainlesssteel bolts, etc. of the required size on the top of the floor of the side of waiste slab with suitable arrangement as per approval of engineer in charge (for payment purpose, only the weight of the stainless steel members shall be considered excluding fixing accessories such as nut bolts, fasteners etc.). 50mm dia. pipe, 1.5mm thickness and weight 1.92Kilogram/ r. metre |
| 10 | ADA compliant modular Multilingual and tactileEmergency evacuation map of each floor indicating the current position of the viewer saying \"YOU ARE HERE\" of 15mm height letters in red with white bacKilogramround, indicating the emergency exits, locations of fire extinguishers etc. Signs shall have a solid header with the text “EVACUATION PLAN” in contrasting uppercase letters no less than 3/4\" in height. The size of the board shall be 2ft x 2ft and shall be installed at a height of 1200mm from FFL and shall be oriented to the position of the viewer asper the direction of the site engineer |
| 11 | Fire exit and floor identification signage as permanufacturer\"s specifications, ADA compliant and modular system |
| 12 | Supplying and installing of in position the signages \" FIREORDER\" it should contain the following matter on 3mm thick \"Opaque\" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinyle painted foam board of 3\" x 4\".Product to be ADA compliant and modular system. |
| 13 | Providing an emergency evacuation chair of the approveddesign, weight and loading capacity |
| 14 | Providing and fixing SS Braille buttons in the elevator ofthe approved brand and make to be installed using the specified adhesive and as per the instructions given by the manufacturer |
| 15 | Providing and fixing of high intensity reflective conspicuitytape 25 to 50mm width, on edges of treads in staircase including, cutting, pasting etc. of make 3M or equivalent brand as per the direction of engineer in charge |
| 16 | Providing a folding wheelchair of Pioneer Surgicals Brand,model One Number PS 809/ equivalent make as per the directions of the engineer in charge. |
| 17 | Design, supply, fabrication and fixing of SS, non glareSignage board (2 ft. x 2 ft.- 1 One Number) for the accessible parking, as per the approved design and make, having 1.2mm thick SS non glare base plate and Grade 2/ Grade 1 Braille (raised dots)to be etched/ engraved and be raised 0.5mm above base plate and Upper Case San Serif words and Universal Accessibility Symbol to be etched/ engraved and signage to be installed at a height of 2100mm from the ground level using a post of MS hollow square section (50mm x 50mm) as per the installation procedure specified by the manufacturer and as per accessibility standards and up to the satisfaction of the engineer in charge |
| 18 | Design, supply, fabrication and fixing of SS, non glaremultilingual Braille (raised dots) entrance signage (size 1 ft x 1 ft) as per the approved design and make,indicating the name of the building. Having 1.2mm thick SS non glare blue coloured base plate with the \"Universal Accessibility Symbol\" and Upper case Sans Serif words of height 15mm engraved on it along with the equivalent word/ s written in Hindi using Devnagri script of height 15mm in whitecolour. Grade 2/ Grade 1 Braille to be etched/ engraved and be raised 0.5mm above base plate.The signage to be installed at the specified location on the compound wall near the site entrance gate installed at a height of 1200 mm from the finished ground/ floor level, using the necessary hardware specified by the manufacturer and tobe installed up to the satisfaction of the engineer in charge. |
| 19 | Providing and laying in place 300mm x 300mm x 9.8mmvitrified tactile warning and directional tiles of the approved brand, make and colour inside the buildings at in all corridors and lobbies, level differences etc. as per accessibility standards and as per the installation instructions prescribed by the manufacturer including zarri making wherever required and finishing including grouting the joints with white cement with matching pigments etc. up to the satisfaction of the engineer in charge complete. |
| 20 | Design, supply, fabrication and fixing acrylic multilingualBraille (raised dots) signboards of size 6\"x 9\" for room titles, designed as per the drawings issued and having 4mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate.Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL andas per the directions by the engineer in charge. |
| 21 | Providing and fixing in place 300mm x 300mm x 3mmpolyurethane stick on tactile directional tiles and warning tiles having beveled edges and of the approved brand, make and colour and conforming to ISO 23599: 2012 inside the building on all floors in corridors, lobbies , level differences as per accessibility standards and to be installed as per the installation instructions given by the manufacturer using butyl rubber adhesive and the hardware specified by the manufacturer, as per thedirection of the engineer in charge complete |
| 22 | Providing and laying in place 300mm x 300mm x 16mmcement tactile directional and warning tiles (for a person with visual impairment)of the approved brand and make and specified colour for outdoor floors such as footpath, courtyard, multimodals location etc. laid on 20mm thick base of cement mortar 1:4 (1 cement: 4 coarse sand) in all shapes and patterns including grouting the joints with white cement with matching pigments etc. complete as per direction of engineer in charge |
| 23 | Grab bars-Providing SS grab bars set for accessible toiletscomprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) ProvidingS.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600MM (H) X 600MM (D) and 32MM DIA. and thickness mm of the approved brand and make. 27c) Straight grab bar (2 NOS) Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make. |
| 24 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete |
| 25 | Removing doors and windows with frames and stackingthe materials as directed with all leads, lifts etc. complete |
| 26 | Removing W.C. pans including disconnecting the sanitaryand water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete. |
| 27 | Removing urinal pans or wash hand basins with frameincluding disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc complete |
| 28 | Removing brick bat coba including stacking the spoils asdirected with all leads, lifts etc, complete |
| 29 | Providing waterproofing in W.C. and bath including brickbat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years\" guarantee on requisite stamp paper including curing etc. complete. |
| 30 | Providing waterproof plaster in W.C. and bath 12 mm thickfor dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) (As directed by Engineer in Charge) |
| 31 | Providing and laying telephone black / Amba White /Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. |
| 32 | Providing and laying ceramic tiles having size 30 cm. x 60cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. |
| 33 | Providing and fixing white european type wall-hung, of size360mm x 360mm x 575mm with flush valve of approved make including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge. |
| 34 | Providing and fixing Table top white wash basin of size120x635x405mm rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. |
| 35 | Providing and fixing 10cm C.I. Nahani Trap including C.I.grating bend and piece of C.I. pipe upto the outside face of the wall complete. |
| 36 | Providing and fixing ISI 1729/2002 grade 100 mm dia CastIron Soil Pipes With lugs including plug bend necessary fittings such as bends, tees, single junction, double junction, slotted vent, offsets on wall or into the ground including filling joints with cement mortar 1:2 proportion fixing on wall by means of galvanised Mild Steel bracket of 30 x 5 mm plate and 8 mm square rod with Galvanised Iron clamp with washer as per design, drawing and as directed to keep pipe 50 mm away from wall including necessary scaffolding and painting the exposed faces with one coat of red lead oil paint and two coats of white oil paint including removing the existing pipe if necessary and conveying and stacking in PWD Chowky or as directed byEngineer-in-Charge. |
| 37 | Providing and fixing ISI 1729/2002 grade 75 mm dia CastIron Waste Water Pipe with lugs necessary fittings such as bends, tees, single junction, double junction, slotted vent, offsets on wall or into the ground including filling joints with cement mortar 1:2 proportion fixing on wall bymeans by galvanised Mild Steel bracket of 30 x 5 mm plate and 8 mm square rod with Galvanised Iron clamp with washer as per design drawing and as directed to keep pipe 50 mm away from wall including necessary scaffolding and painting the exposed faces with one coat of red lead oil paint and two coats of gray oil paint including removing the existing pipe if necessary and conveying and stacking inPWD Chowky or as directed by Engineer-in-Charge. |
| 38 | Providing and fixing chromium plated towel rod 16 mm diaand 75 cm. in length including all accessories complete. |
| 39 | Providing and fixing wall hung white wash basin of size350x450x165mm with approved make pillar cock, C.P. Angular stop cock long thread approved make continental including SS bottle trap of approved make having necessary pipe connection up to the outside face of the wall etc complete as directed by Engineer in charge. |
| 40 | Providing and fixing 34 mm thick moulded door shutterconsisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc.complete. |
| 41 | Providing and fixing C.P. 2 Way BIB cock with wall flange ofapproved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. |
| 42 | Providing and fixing 450mm x 550mm size superior typeBelgium mirror with 16mm dia. nickel plated towel rod etc. complete |
| 43 | C.P.Toilet paper holder jaquar make continenta |
| 44 | Providing and fixing C.P. BIB cock with wall flange ofapproved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. |
| 45 | Providing and fixing on walls/ ceiling/ floors, 15 mm dia.heavy grade having embossed as ISI Mark galvanised iron pipes weight of 1.48 Kilogram/metre with necessaryfittings. remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete |
| 46 | Providing and fixing aluminium grill`(5.13 Kilogram/SquareMetre) decorative of various sizes as per detail drawing and specification etc. complete. (Prior permission to be obtained from S.E. before execution of this item) ( 5.13 Kilogram/ One Square Metre) |
| 47 | super jet spray with flange 2 in 1 faucet 1.50 metre long |
| 48 | C.P.soap dish (polyurethane) jaquar make continental |
| 49 | Piller cock mixer & Angle cock |
| 50 | Providing and laying Antiskid Ceramic tiles of approvedquality of size 30 cm x 30 cm and confirming to IS 15622- 2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. |
| 51 | Providing and fixing fiber glass reinforced polyster doorshutter 35 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete. |
| 52 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. |
| 53 | Providing and laying Cast in situ/Ready Mix cementconcrete in M15 of trap/ granite/quartzite/gneiss metal for foundation / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sandVSI Grade) |
| 54 | Providing and laying telephone black / Amba White /Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete |
| 55 | Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete |
| 56 | Providing and fixing 900mm high S.S.304 Grade Stainlesssteel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete |
| 57 | GSR Civil works percentage rate quote |
| 58 | GSR Electrical works percentage rate quote |
| 59 | Accessible Portable Toilet and Sanitation system |
| 60 | Providing and Installing on location Accessible Portable Toilet and Sanitation System of Davico or equivalent as directed by Access Consultant / Engineer in charge as per following specifications. |
| 61 | Walls and celings of F.R.P. sandwich panel with 25 mm foam sandwiched in between, metal framed structure provided. Overhead water tank of approx 500 litres capacity. Bio septic tank of approximately 1000 litres capacity. Bottom steel structure with grating of 38 mm x 38 mm x 38 mm with chequered plate for floor and installation of western toilet deat with in built sensor flushing technology that ensures tough free and hygienic expereince to user. The size of the western seat is 62 cm x 37 cm x 67 cm along with Brisk health faucet ABS with Rubbit cleaning system with basin and tap with sensor. Ramp for wheelchair with gradient of 1:12 along with safety edge protection / kerb and / or railings to facilitate movement of whelchair user on the ramp. Inbuilt light fittings and fixtures provided in the toilet block. Clear internal size of the accessible toilet block will not less than 2000 mm x 2000 mm unless otherwise specified by Access Consultant / Engineer in Charge. The plinth height shall be 200 to 300 mm. |
| 62 | Providing and Installing in place as directed by Acccess Consultant / Engineer in charge Accessible Hydraulic Lift / Machine Roomless / Geared Traction with Machine room as deemed fit for the particular site application as recommened by Access Consultant / Engineer in charge. Lift cabin size to be not less than 1500 x 1500 mm to allow for easy wheelchair manouvering. Lift to be provided with standard safety features such as Automatic Rescur Device, emergency Light and Alarm, Automatic Fan operation, Infra red sensor, safety features in case of rope breakage, Overload Sensor |
| 63 | Designing and installing in location as specified by Access Consultant / Engineer in charge, navigation and wayfinding system such as IWAYPLUS or equivalent to assist PwDs , especailly PWVI . The localisation and position system is based on state of art BLE technology. The system will comply with WACG3 standards for micro captioning as per ITU.921 IABNNS standards. Scope includes creation of digital map and AI based auto routing algorithms for wayfinding to guide a user within the building. |
| 64 | Accessible Lift Type Of Lift : MRL Gearless Cantilever PassengerNo. of Elevators : 1 / OneType & Capacity : 6 persons or 1 wheel chair or 408 kgsSpeed / Drive : 0.65 meters per second.Location of Machine : Inside the lift shaftTravels : 5 meters (Approx), G+1, 2 LandingsRequired well size : 1800 mm wide x 1700 mm DeepHead Room Required : 4450 mmPit Required : 300 mm (one step will have to be raised)Power Supply : 230 V, Singlephase. 50 cycles, A.C.Car Size clear inside : 1150 mm wide x 1000 mm deep (approx) Car Enclosure : S.S. Hairline Finish CabinFlooring : Antiskid PVC FlooringElectric Light : LED FittingsFan : Automatic BlowerEntrances Position : Same sideCar Entrance : S.S. Hairline Finish Telescopic Auto Door Landing Entrance : S.S. Hairline Finish Telescopic Auto Doors Clear Opening : 900 mm Wide x 2000 mm HighIndicators : Car & Landing : Digital Position and Direction indicators in car & at allLanding in stainless steel face plates.Control : Microprocessor based Down Collective assembled in M.S.Covered Cabinet with VVVF DriveOther features 1. Alarm Button in Car Operating Panel with battery backup,2. Auto Fan Operation3. Emergency Light4. Phase failure and phase reversal protection5. Dot matrix scrolling display in Car and Landing operating Panels.6. Automatic Rescue device / UPS |
| 65 | Carrier VRF Schedule ISupplyof High side CARRIER \ DAIKIN \ TOSHIBA \ EQUIVALENT VRFsystem equipments |
| 66 | Supply of aircooled, invertor basedVariable Refrigerant Flow modular construction suitable for indoor unit tonnage as specified below with adequate diversity. Compressors shall be hermetically sealed invertor based scroll and fixed scroll combination operating on R-410A refrigerant with loading and unloading capacity control from 10% to 100% as per cooling load variation. The outdoor unit shall have accumulator & Receiver with built in oil seperator. The outdoor unit shall be operated on 3 phase 440V, 50Hz AC supply. The air cooled Condensor shall have axial flow, upward through fan coupled to fan motors. |
| 67 | 14 HP |
| 68 | Supply ofCeiling Mounted 4 way cassette type indoor units suitable for VRV/VRF system,operating on 230V, single phase, 50 Hz A.C. supply with electronic expansion valve for refrigerant flow control operated by microprocessor thermostat based temperature control to meet the cooling requirements. The indoor units are to be operated by cordless type remote controlas specified. |
| 69 | 2 TR |
| 70 | Supplyof DX type Split Tower AC comprsing of 1 out door unit with scroll /Rotary compressor along with copper consenser motor and fan blade. Unit should be microprocessor based and with R 410 A / R32 Refrigerant |
| 71 | 2 TR |
| 72 | INSTALLATION & LOWSIDE |
| 73 | Installation of modular outdoor unitsprovided on each level with appropriate vibration isolators, equailiser piping if any for gas and oil between modular units. |
| 74 | 12 HP |
| 75 | Installation of VRF indoor units |
| 76 | Cassette Type Unit |
| 77 | Installation of DX Split Tower AC |
| 78 | Supply & Installationof refrigerant branch kit with insulation suitable for different branch sizes. |
| 79 | Supply, installation, testing & commissioning of Refrigerant copper pipe suitable for VRF system with R410 gas & having guage thickness and inner dia as below. Piping should be insulated with Elastometric Nitrile rubber foam tube type sleeves for over coating and insulating on provided copper pipes having 19mm thickness, and fitted between out door units to indoor units with the required connections, bends, & hardware as per the specifications, the cable trays on walls, roof / ceiling well supported at specific intervalsand screwed with anchor fasteners. |
| 80 | Supply Of soft drawn copper pipe with 10 mm thick nitrile tubularinsulation for Tower split AC |
| 81 | Supply & fixing of Hard drawn PVC pipe with duly insulatedwith nitrile tubular insulationfor condensate wateras per below mentioned sizes. |
| 82 | 32 mm |
| 83 | 25mm |
| 84 | Supply & fixing of 3 core 1.5 sq mm flexible copperCommunication Cablebetween indoor and out door unit drwan throughhardpvc conduit |
| 85 | Supply & fixing ofpowder coatedMS stand for mounting condensing unit for VRVODU |
| 86 | Supply & Topping upof Refrigerant R 410 A |
| 87 | Supply of MS stand for mounting Tower AC Out door unit |
| 88 | VRF and split Schedule IISupplyof High side CARRIER \ DAIKIN \ TOSHIBA \ EQUIVALENT VRFsystem equipments |
| 89 | Supply of aircooled, invertor basedVariable Refrigerant Flow modular construction suitable for indoor unit tonnage as specified below with adequate diversity. Compressors shall be hermetically sealed invertor based scroll and fixed scroll combination operating on R-410A refrigerant with loading and unloading capacity control from 10% to 100% as per cooling load variation. The outdoor unit shall have accumulator & Receiver with built in oil seperator. The outdoor unit shall be operated on 3 phase 440V, 50Hz AC supply. The air cooled Condensor shall have axial flow, upward through fan coupled to fan motors. |
| 90 | 10 HP |
| 91 | Supply ofCeiling Mounted 4 way cassette type indoor units suitable for VRV/VRF system,operating on 230V, single phase, 50 Hz A.C. supply with electronic expansion valve for refrigerant flow control operated by microprocessor thermostat based temperature control to meet the cooling requirements. The indoor units are to be operated by cordless type remote controlas specified. |
| 92 | 4 TR |
| 93 | 3 TR |
| 94 | 2 TR |
| 95 | 1.5 TR |
| 96 | Supply Of DX type Hi wall inverter3 star Split ACwith cordless Remote controller |
| 97 | 2 TR |
| 98 | 1.5 TR |
| 99 | INSTALLATION & LOWSIDE |
| 100 | Installation ofVRF outdoor unitsprovided on each level with appropriate vibration isolators, equailiser piping if any for gas and oil between modular units. |
| 101 | 10 HP |
| 102 | Installation of indoor units |
| 103 | Cassette Type Unit |
| 104 | Hi wall Split AC |
| 105 | Supply & Installationof refrigerant branch kit with insulation suitable for different branch sizes. |
| 106 | Supply, installation, testing & commissioning of Refrigerant copper pipe suitable for VRF system with R410 gas & having guage thickness and inner dia as below. Piping should be insulated with Elastometric Nitrile rubber foam tube type sleeves for over coating and insulating on provided copper pipes having 19mm thickness, and fitted between out door units to indoor units with the required connections, bends, & hardware as per the specifications, the cable trays on walls, roof / ceiling well supported at specific intervalsand screwed with anchor fasteners. |
| 107 | Supply, installation, testing & commissioning of Refrigerant copper pipe suitable forHI wall split AC with R410 gas & having guage thickness and inner dia as below. Piping should be insulated with Elastometric Nitrile rubber foam tube type sleeves for over coating and insulating on provided copper pipes having 9mm thickness, and fitted between out door units to indoor units with the required connections, bends, & hardware as per the specifications. |
| 108 | Supply & fixing of Hard drawn PVC pipe with duly insulatedwith nitrile tubular insulationfor condensate wateras per below mentioned sizes. |
| 109 | 32 mm |
| 110 | 25mm |
| 111 | Supply & fixing of 3 core 1.5 sq mm flexible copperCommunication Cablebetween indoor and out door unit drwan throughhardpvc conduit |
| 112 | Supply & fixing ofpowder coatedMS stand for mounting condensing unit for VRVODU |
| 113 | Supply & fixing ofpowder coatedMS stand for mounting condensing unit forHi wall Split ODU |
| 114 | Supply & Topping upof Refrigerant R 410 A |
| 115 | Supply & installtion of 4 KVA voltage stabilizer |
| 116 | Supply & installtion of 5 KVA voltage stabilizer |
| 117 | carrier VRF Schedule IIISupplyof High side CARRIERVRFsystem equipments |
| 118 | Supply of aircooled, invertor basedVariable Refrigerant Flow modular construction suitable for indoor unit tonnage as specified below with adequate diversity. Compressors shall be hermetically sealed invertor based scroll and fixed scroll combination operating on R-410A refrigerant with loading and unloading capacity control from 10% to 100% as per cooling load variation. The outdoor unit shall have accumulator & Receiver with built in oil seperator. The outdoor unit shall be operated on 3 phase 440V, 50Hz AC supply. The air cooled Condensor shall have axial flow, upward through fan coupled to fan motors. |
| 119 | 10 HP |
| 120 | 12 HP |
| 121 | Supply ofCeiling Mounted 4 way cassette type indoor units suitable for VRV/VRF system,operating on 230V, single phase, 50 Hz A.C. supply with electronic expansion valve for refrigerant flow control operated by microprocessor thermostat based temperature control to meet the cooling requirements. The indoor units are to be operated by cordless type remote controlas specified. |
| 122 | 4 TR |
| 123 | 3 TR |
| 124 | 2.5 TR |
| 125 | 2 TR |
| 126 | 1.5 TR |
| 127 | 0.8 TR |
| 128 | INSTALLATION & LOWSIDE |
| 129 | Installation of modular outdoor unitsprovided on each level with appropriate vibration isolators, equailiser piping if any for gas and oil between modular units. |
| 130 | 22 HP( 10 + 12) |
| 131 | Installation of VRF indoor units |
| 132 | Cassette Type Unit |
| 133 | Supply & Installationof refrigerant branch kit with insulation suitable for different branch sizes. |
| 134 | Supply, installation, testing & commissioning of Refrigerant copper pipe suitable for VRF system with R410 gas & having guage thickness and inner dia as below. Piping should be insulated with Elastometric Nitrile rubber foam tube type sleeves for over coating and insulating on provided copper pipes having 19mm thickness, and fitted between out door units to indoor units with the required connections, bends, & hardware as per the specifications, the cable trays on walls, roof / ceiling well supported at specific intervalsand screwed with anchor fasteners. |
| 135 | Supply & fixing of Hard drawn PVC pipe with duly insulatedwith nitrile tubular insulationfor condensate wateras per below mentioned sizes. |
| 136 | 32 mm |
| 137 | 25mm |
| 138 | Supply & fixing of 3 core 1.5 sq mm flexible copperCommunication Cablebetween indoor and out door unit drwan throughhardpvc conduit |
| 139 | Supply & fixing ofpowder coatedMS stand for mounting condensing unit for VRVODU |
| 140 | Supply & Topping upof Refrigerant R 410 A |
| 141 | Electrical Items |
| 142 | INVERTER |
| 143 | Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz,digital pure sine wave inverter with backup time of 30 minutes based on Insulated Gate Bipolar Transistor (IGBT) technology and inclusive of required number of SMF batteries, battery terminal wire, duly charged and complete with all protections. |
| 144 | 700VA - 900 VA |
| 145 | 1400 -1600 VA |
| 146 | 2500 VA |
| 147 | UPS |
| 148 | Supplying, erecting, testing and commissioning of online pure sine wave with backup time of 30 minutes PWM & IGBT based UPS with 0.9 to unity output pf and inclusive of required number of SMF batteries, battery terminal wire, duly charged and complete with all protections. |
| 149 | 6kVA, 1 phase input & 1 phase output |
| 150 | 10kVA, 1 phase input & 1 phase output |
| 151 | 10kVA, 3 phase input & 1 phase output |
| 152 | GENERATORSupplying, erecting, testing and commissioning of Diesel generating set with microprocessor based AMF panel with alternator of following continuous rating, 50c/s, 0.8 p.f.A.C. supply. A totally enclosed air / liquid cooled multi cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours with standard accessories, self-excited, selfregulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption @75% loading as per standards. The emission standards/norms shall meet applicable pollution control board norms as amended by Government. Engine and alternator directly coupled on a common fabricated steel base plate with anti-vibrating pad, with control panel comprising of standard meters, switchgears, indicators connected with suitable wires/cables. The complete set enclosed in acoustic enclosure made of 18 SWG CRCA sheet, sound absorbing material, rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level up to 75 dB at 1.0 m. on provided M20 Grade CC Foundation |
| 153 | 5kVA, 1 Phase, 230V |
| 154 | 10kVA, 3 Phase, 415V |
| 155 | 15 - 20 kVA, 3 Phase, 415V |
| 156 | 25 -35 kVA, 3 Phase, 415V |
| 157 | 40- 50 kVA, 3 Phase, 415V |
| 158 | 62.5 - 82.5 kVA, 3 Phase, 415V |
| 159 | 100 - 125 kVA, 3 Phase, 415V |
| 160 | 100 - 125 kVA, 3 Phase, 415V |
| 161 | 160 - 180 kVA, 3 Phase, 415V |
| 162 | 200 - 250 kVA, 3 Phase, 415V |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy