| 1 | Dismantling fencing wire mesh, any type complete all as specified and directed. |
| 2 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground embedded in normal ground complete all as specified and directed. |
| 3 | Taking down cement plaster of any description on brick or stone or concrete surface of wall etc includingraking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 4 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed. |
| 5 | Demolition of cement concrete in ground floor, (unreinforced) paving not execeeding 15cm thick (below or above GL) complete all as specified and directed. |
| 6 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 7 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specially provided for complete all as specified and directed. |
| 8 | Dismantling structural steel work including fencing post, doors, windows, gates but excluding framed truss etc. complete all as specified and directed. |
| 9 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 10 | M&L for brick work with sub class \"B\" bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed. |
| 11 | All as per Item No. 10.00 here-in-before but except bricks complete all as specified and directed. |
| 12 | M&L forPrecast cement concrete block (1:3:6) type C-1 (using 20 mm graded crushed stoneaggregate) exceeding 10cm in width and setting in Cement Mortar(1:6) as in kerb stones including necessary made of ground for fixing complete all as specified and directed. |
| 13 | M&L forplain cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate), as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbsand the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed. |
| 14 | M&L forPCC (1:3:6) type C-2 (using 40 mm graded crushed stoneaggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 15 | M&L forPCC (1:4:8) type D-2 (using 40 mm graded crushed stoneaggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 16 | M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stoneaggregate) as in foundationsincluding rafts, footings, foundation beam, plinth beams, bases for columns etc , basement slabs, under-reamed piles and mass concrete etc complete all as specified anddirected. |
| 17 | M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stoneaggregate)as in column, pillar, piers, post and struts etc complete all as specified and directed. |
| 18 | Supply only integral water proofing compound liquid, ISI markedcomplete all as specified and directed. |
| 19 | M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 20 | M&L for TMT bars5mmdia and over upto and including 10mm dia instirrups, spacers andbinders and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 21 | S&F for angle iron works as in post and struts in fencing post including cutting tops to shape as directed, drilling holes, bolting or riveting, notching for wire etcconforming to Fe. 290 Gde E-165 complete all as specified and directed. |
| 22 | S&F of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/orforged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0Gde-E-165 completeall as specified and directed. |
| 23 | S&F for galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings & straining & fixing to any type of standard rails straining bolts, including, securing or tying at crossings with & provision of galvanised mild steel wire, staples or steel pins, etc.after and including taking down old unserviceable galvanised steel barbed wirecomplete all as specified anddirected. (Note: Each line ofwire to be measured). |
| 24 | S&F for mild steel screw bolts (machine made) 11 to 15mm with hexagonal head at one end and screwed the other end, each screw end to be fitted with two washers and one hexagonal or square nut, length of bolts 50mm to 100mm complete all as specified and directed. |
| 25 | Supply only Chain link MS galvanisd fencing, of size 75 X 75mm mesh and 4mm dia wire complete all as specified and as directed. |
| 26 | Fixing only chain link MS galvanised fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.(Note: Meterials to be used in item No.25.00 here-in-before) |
| 27 | Supply only MS round bars 10mm dia for securing chain link fencing fixed to RCC fencing postsas per Fe-410-W (Gde- E-250) quality \"A\" or Fe-290 (Gde E-165)complete all as specified and directed.(Note: Meterials to be used in item No.26.00 here-in-before) |
| 28 | M&L for rendering 15 mm thick on other than fair face of brick worksor concretesurfaces of wallswith cement mortar (1:4)mixed with WPC @200ml per 50 Kg of cement or as per manufacturer\"s instructions ,finished the surfaces even and smoothwithout using extra cement complete all as specified anddirected. (Note : WPC will be measured and paid separately under relevant item) |
| 29 | M&L for 18-20mm thick Mirror polished, high gloss finish Granite (absolute Jet Black) work in steps, jambs & soffits of chowkhat (incl necessary pasting), pillars, window-cills, basin platforms, urinal partitions and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl necessary cutting for sunk basin/sink, making holes for fixing hinges, door bolts, etc 15mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishescomplete all as specified and directed. |
| 30 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paverblock of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of over blocks as per required size and pattern, finishing and sweeping extras and complete all as specified and directed. |
| 31 | M&L for 25mm thick cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as coping etc including moulding at junction and including necessary formwork complete all as specified and directed. |
| 32 | M&L for 40 mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in floor/paving etc finished even and smooth without using extra cementcomplete all as specified and directed. |
| 33 | M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protectionincluding finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 34 | M&L forplain cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate), as in seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbsand the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed. |
| 35 | M&L for applying two coats of synthetic enamel paint (1st grade quality) overa coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth completeall as specified and directed. |
| 36 | M&L for applying two coats of synthetic enamel paint (1st grade quality) overa coat of red oxide primer after preparation of new steel surfaces of any description over not exceeding 10cm width or girth completeall as specified and directed. |
| 37 | M&L for applying two coats of cement based paint over a coat of alkali resistance primeron newly plastered surface of walls including preparation ofsurface complete all as specified anddirected. |