Special Repair To JcoS Married Accn Building No. 816 Of Hq 6 Sector Assam Rifles At Kashiram Basti. (B)Special Repair To OrS Married Accommodation Building No. Dsp/901 And Dsp/902 Of Hq 6 Sector Assam Rifles At Kashiram Basti, Dimapur (C) Special Repair, dimapur-Nagaland

Assam Rifles-AR has published Special Repair To JcoS Married Accn Building No. 816 Of Hq 6 Sector Assam Rifles At Kashiram Basti. (B)Special Repair To OrS Married Accommodation Building No. Dsp/901 And Dsp/902 Of Hq 6 Sector Assam Rifles At Kashiram Basti, Dimapur (C) Special Repair. Submission Date for this Tender is 22-11-2023. Electrification Work Tenders in dimapur Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

40466924
Special Repair To JcoS Married Accn Building No. 816 Of Hq 6 Sector Assam Rifles At Kashiram Basti. (B)Special Repair To OrS Married Accommodation Building No. Dsp/901 And Dsp/902 Of Hq 6 Sector Assam Rifles At Kashiram Basti, Dimapur (C) Special Repair
Open Tender
Indian
Nagaland
dimapur
22-11-2023

Tender Details

Special Repair To JcoS Married Accn Building No. 816 Of Hq 6 Sector Assam Rifles At Kashiram Basti. ( B ) Special Repair To OrS Married Accommodation Building No. Dsp / 901 And Dsp / 902 Of Hq 6 Sector Assam Rifles At Kashiram Basti, Dimapur ( C ) Special Repair To Single Men Barrack ( G+Ii ) ( Building No. Dsp / 861 ) Of Including Rewiring And Allied Works For Hq 6 Sector Assam Rifles At Kashiram Basti, Dimapur ( D ) Special Repair To Single Men Barrack ( G+Ii ) ( Building No. Dsp / 865 ) Of Including Rewiring And Allied Works For Hq 6 Sector Assam Rifles At Kashiram Basti, Dimapur ( E ) Special Repair And Replacement Of Leaking Pipe Line And Allied Works To Type -Ii Accn At Bn Klp At Kashirambasti ( Bldg No. Dsp / 816 A &B, 852, 823, 824, 825, 826, 847, 845 & 846 ) .

Key Value

Document Fees
INR 1500 /-
EMD
INR 431700.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : (A) Special repair to JCO"s married accn Building No. 816 of HQ 6 Sector Assam Rifles at Kashiram Basti. (B)Special repair to OR"s married accommodation Building No. DSP/901 and DSP/902 of HQ 6 Sector Assam Rifles at Kashiram Basti, Dimapur (C) Special repair to Single Men Barrack (G+II) (Building No. DSP/861) of including Rewiring and allied works for HQ 6 Sector Assam Rifles at Kashiram Basti, Dimapur (D) Special repair to Single Men Barrack (G+II) (Building No. DSP/865) of including Rewiring and allied works for HQ 6 Sector Assam Rifles at Kashiram Basti, Dimapur(E) Special repair and replacement of Leaking pipe line and allied works to Type -II accn at Bn KLP at Kashirambasti (Bldg No. DSP/816 A &B, 852, 823, 824, 825, 826, 847, 845 & 846).
Sl. No. Item Description
1SCHEDULE ‘A’ (Special repair to JCO"s married accn Building No. 816 )
2SCHEDULE ‘A’ Part - I (Civil Works) : - Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :Old work (one or more coats) including Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
3M/L for one or more coats painting with synthetic enamel paint of approved brand and required colour of old work
4Finishing witth acrylic smooth exterior paint of required shade Old work (Oneor more coat applied @ 0.90 ltr/10 sqm).including removal of dry or oil bound istemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
5Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete.20 mm diameter.
6Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 2nd class teak wood beading 62X19 mm
7Providing & fixing 4.0 mm thick glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete.
8Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead :With cement mortar 1:4 (1 cement : 4 Coarse sand)
9Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
10Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.
11Providing and fixing Ist quality ceramic glazed wall tilesonforming to IS: 15622 (thickness to be specified by the manufacturer), ofapproved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
12Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below
13Supply and fixing 35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm, out of which 75 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer"s specification and direction of Engineer-in-charge. Non decorative finish (matt finish)
14Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
15Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
16Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
17Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat
18Demolishing dry brick pitchingin floors, drain etc including stacking serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in - charge.
19Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
20Floor polishing on masonry or concrete floors with wax polish of approved brand and manufacture.
21Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal ofUnserviceable materials within 50 metres lead.
22Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White
23Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
24Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia
25Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
26Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms
27Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
28Providing and fixing brass tower bolts, ISI marked,( barrel type)with necessary screws etc. complete :200x10 mm.
29Providing and fixing brass handles, ISI marked, with necessary screws etc. complete : 125 mm
30Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250 mm diameter
31Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 100 mm nominal inner dia Pipes
32Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
33Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved qualityRectangular shape 600x450 mm internal dimensions
34Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal outer dia Pipes
35Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20 mm nominal bore
36Providing and fixing C.P. brass bib cock of approved qualityconforming to IS:8931 : 15 mm nominal bore
37Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 107 mm long, weighing not less
38SCHEDULE ‘A’ Part - II (ELECTRICAL WORKS) : - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single corecable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required (Group B).
39Wiring for circuit/ submain wiring along with earth wire with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
40Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required
41Supplying and fixing of 5/6 amps switch piano typeon the existing switch box/ cover including connections etc. as required.
42Supplying and fixing of 3 pin 5/6 amp socket outlet on the existing switch box/ cover including connections etc. as required.
43Wiring for circuit/ submain wiring along with earth wire with 2 X 6 sq. mm + 1 X 6 sq. mm earth wire sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
44Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required
45Supplying and fixing oflampholder case body of Bakelite with back plate suitable for batten fittings including connection etc. complete all as specified and as directed.
46Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
47Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
48Supplying and fixing of 8 way, double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
49Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
50Supply & fixing LED tube light fittings 18 watts along with pre-wired,of all types, with all accessories and tube etc. directly on ceiling/ wall, includingsingle core cable and earthing etc. as required.connection with 1.5 sq. mm FR PVC insulated, copper conductor,
51Supply and fixing 20 Amp SPN, Industrial type socket outlet with plug top and metal chained cover in sheet enclosure ( for Geyser).
52Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for Single pole inductive load ofpoles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
53Supplying and fixing of 40 amps rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
54Providing and fixing 100 A, 16 KA,TP MCCBrating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
55Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
56Supplying and fixing of 4 way, (4+12), double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
57Earthlings with copper earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe pf2.7 metre long etc with charcoal/coke and salt as required.
58SCHEDULE OF CREDIT : Old unserviceable wiring for light /fan/exhaust/call bell points complete of any size and any type.
59Old unserviceable wiring for circuit/Submain wiring along with earth wire complete of any size and any type.
60Old unserviceable DB comlete of any size and any type.
61Old unserviceable MCB/MCCB of any size and any type.
62Old unserviceable LED tube light fittings complete of any size and any type.
63Old unserviceable earthing plate and including strips.
64SCHEDULE ‘B’ (Special repair to OR"s married accommodation Building No. DSP/901 and DSP/902)
65SCHEDULE ‘B’ PART - I (CIVIL WORKS) :- Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on Old work (one or more coats) and as per directin of Engr -in - Charge.
66Painting with synthetic enamel paint One or more coats on old workof approved brand and manufactureof required colour to give an even shade.
67Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
68Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of thickness 4 mm
69Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :200x10 mm
70Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete,125 mm
71Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, Incl disposal of rubbish to the dumping ground within 50 metres lead :With cement mortar 1:4 (1 cement : 4 fine sand)
72Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
73Providing & fixing fly proof wire gauze to windows, clerestory windows & doorswith M.S. Flat 15x3 mm and nuts & bolts complete. Galvanised M.S. Wire gauzewith0.63 mm dia wire and 1.4 mm aperture on both sides
74Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary completeof 20 mm diameter.
75Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia
76Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms
77Providing and fixing of PTMT Swivelling shower rose, 15mm nominal bore, weighing not less than 40 gms.
78Finishing walls with Acrylic Smooth exterior paint of required shade on Old work (one or more coat applied @ 1.67 ltr/10 sqm) on existing cement paint surface, including removing of old water proofing cement paint by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc complete.
79Constructing brick masonry manhole in cement mortar 1:4 ( 1cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1cement :2 coarse sand (zone-III) : 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x90 cm and 100 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
80Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved qualityRectangular shape 600x450 mm internal dimensions
81Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes.
82- Ditto - but 15 mm nominal dia Pipes.
83Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete of 20 mm nominal bore
84Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 of 15 mm nominal bore
85Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 107 mm long, weighing not less
86SCHEDULE ‘B’ PART - II (ELECTRICAL WORKS) :- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single corecable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required (Group B).
87Wiring for circuit/ submain wiring along with earth wire with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
88Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required
89Supplying and fixing of 5/6 amps switch piano typeon the existing switch box/ cover including connections etc. as required.
90Supplying and fixing of 3 pin 5/6 amp socket outlet on the existing switch box/ cover including connections etc. as required.
91Wiring for circuit/ submain wiring along with earth wire with 2 X 6 sq. mm + 1 X 6 sq. mm earth wire sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
92Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required
93Supplying and fixing oflampholder case body of Bakelite with back plate suitable for batten fittings including connection etc. complete all as specified and as directed.
94Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
95Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
96Supplying and fixing of 8 way, double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
97Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
98Supply & fixing LED tube light fittings 18 watts along with pre-wired,of all types, with all accessories and tube etc. directly on ceiling/ wall, includingsingle core cable and earthing etc. as required.connection with 1.5 sq. mm FR PVC insulated, copper conductor,
99Supply and fixing 20 Amp SPN, Industrial type socket outlet with plug top and metal chained cover in sheet enclosure ( for Geyser).
100Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for Single pole inductive load ofpoles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
101Supplying and fixing of 40 amps rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
102Providing and fixing 100 A, 16 KA,TP MCCBrating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
103Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
104Supplying and fixing of 4 way, (4+12), double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
105Earthlings with copper earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe pf2.7 metre long etc with charcoal/coke and salt as required.
106SCHEDULEOF CREDIT : Old unserviceable wiring for light /fan/exhaust/call bell points complete of any size and any type.
107Old unserviceable wiring for circuit/Submain wiring along with earth wire complete of any size and any type.
108Old unserviceable DB comlete of any size and any type.
109Old unserviceable MCB/MCCB of any size and any type.
110Old unserviceable LED tube light fittings complete of any size and any type.
111Old unserviceable earthing plate and including strips.
112SCHEDULE ‘C’ PART -I (Special repair to Single Men Barrack (G+II) (Building No. DSP/861) of including Rewiring and allied works)
113Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead :With cement mortar 1:4 (1 cement : 4 fine sand)
114Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
115Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :Old work (one or more coats) including Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
116Finishing walls with Acrylic Smooth exterior paint of required shade on Old work (one or more coat applied @ 0.90 ltr/10 sqm) on existing cement paint surface, including removing of old water proofing cement paint by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc complete.
117M/L for one or more coats painting with synthetic enamel paint of approved brand and required colour of old work
118Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
119Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
120Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).
121Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes
122Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides
123Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 2nd class teak wood beading 62X19 mm
124Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete.20 mm diameter.
125Painting with synthetic enamel paint with black Japan paintof approved brand and manufacture of required colour to give an even shade :One or more coats on old work
126Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
127Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
128Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
129Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
130Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.
131Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
132Floor polishing on masonry or concrete floors with wax polish of approved brand and manufacture.
133Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White
134Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm
135Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250 mm diameter
136Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 100 mm nominal inner dia Pipes
137Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead ofarea 3 sq. metres and below
138Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (± 0.2 mm), made out of single piece extruded PVC profile, with mitred cut joints and joint with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8 x100 mm long anchor fasteners complete, all as per manufacturer"s specification and directionof Engineer -in- charge.
139Supply and fixing 35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side),self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm, out of which 75 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer"s specification and direction of Engineer-in-charge, Non decorative finish (matt finish)
140Constructing brick masonry manhole in cement mortar 1:4 ( 1cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x90 cm and 100 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
141SCHEDULE ‘C’ PART - II (ELECTRICAL WORKS) :- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single corecable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required (Group B).
142Wiring for circuit/ submain wiring along with earth wire with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
143Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required
144Supplying and fixing of 5/6 amps switch piano typeon the existing switch box/ cover including connections etc. as required.
145Supplying and fixing of 3 pin 5/6 amp socket outlet on the existing switch box/ cover including connections etc. as required.
146Wiring for circuit/ submain wiring along with earth wire with 2 X 6 sq. mm + 1 X 6 sq. mm earth wire sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
147Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required
148Supplying and fixing oflampholder case body of Bakelite with back plate suitable for batten fittings including connection etc. complete all as specified and as directed.
149Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
150Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
151Supplying and fixing of 8 way, double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
152Supplying and fixing of 6 way, double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
153Supply & fixing LED tube light fittings 18 watts along with pre-wired,of all types, with all accessories and tube etc. directly on ceiling/ wall, includingsingle core cable and earthing etc. as required.connection with 1.5 sq. mm FR PVC insulated, copper conductor,
154Supply and fixing 20 Amp SPN, Industrial type socket outlet with plug top and metal chained cover in sheet enclosure ( for Geyser).
155Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for Single pole inductive load ofpoles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
156Supplying and fixing of 40 amps rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
157Providing and fixing 100 A, 16 KA,TP MCCBrating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
158Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
159Supplying and fixing of 4 way, (4+12), double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
160Earthlings with copper earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe pf2.7 metre long etc with charcoal/coke and salt as required.
161SCHEDULEOF CREDIT : Old unserviceable wiring for light /fan/exhaust/call bell points complete of any size and any type.
162Old unserviceable wiring for circuit/Submain wiring along with earth wire complete of any size and any type.
163Old unserviceable DB comlete of any size and any type.
164Old unserviceable MCB/MCCB of any size and any type.
165Old unserviceable LED tube light fittings complete of any size and any type.
166Old unserviceable earthing plate and including strips.
167SCHEDULE ‘D’ PART -I (Special repair to Single Men Barrack (G+II) (Building No. DSP/865) of including Rewiring and allied works)
168SCHEDULE ‘D’ PART -I (CIVIL WORKS) :-Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
169Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
170Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).
171Supply and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer"s specification
172Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
173Distempering on Old work (one or more coats)with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade.
174Finishing witth acrylic smooth exterior paint of required shade Old work (Oneor more coat applied @ 0.90 ltr/10 sqm).including removal of dry or oil bound istemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
175M/L for one or more coats painting with synthetic enamel paint of approved brand and required colour of old work
176Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes
177Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead :With cement mortar 1:4 (1 cement : 4 fine sand)
178Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides
179Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 2nd class teak wood beading 62X19 mm
180Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete.20 mm diameter.
181Painting with synthetic enamel paint with black Japan paintof approved brand and manufacture of required colour to give an even shade :One or more coats on old work
182Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
183Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
184Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
185Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.
186Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
187Floor polishing on masonry or concrete floors with wax polish of approved brand and manufacture.
188Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White
189Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm
190Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250 mm diameter
191Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 100 mm nominal inner dia Pipes
192Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead ofarea 3 sq. metres and below
193Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (± 0.2 mm), made out of single piece extruded PVC profile, with mitred cut joints and joint with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8 x100 mm long anchor fasteners complete, all as per manufacturer"s specification and directionof Engineer -in- charge.
194Supply and fixing 35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side),self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm, out of which 75 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer"s specification and direction of Engineer-in-charge, Non decorative finish (matt finish)
195Constructing brick masonry manhole in cement mortar 1:4 ( 1cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x90 cm and 100 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
196SCHEDULE ‘D’ PART - II (ELECTRICAL WORKS) :- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single corecable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required (Group B).
197Wiring for circuit/ submain wiring along with earth wire with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
198Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required
199Supplying and fixing of 5/6 amps switch piano typeon the existing switch box/ cover including connections etc. as required.
200Supplying and fixing of 3 pin 5/6 amp socket outlet on the existing switch box/ cover including connections etc. as required.
201Wiring for circuit/ submain wiring along with earth wire with 2 X 6 sq. mm + 1 X 6 sq. mm earth wire sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
202Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required
203Supplying and fixing oflampholder case body of Bakelite with back plate suitable for batten fittings including connection etc. complete all as specified and as directed.
204Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
205Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
206Supplying and fixing of 8 way, double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
207Supplying and fixing of 6 way, double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
208Supply & fixing LED tube light fittings 18 watts along with pre-wired,of all types, with all accessories and tube etc. directly on ceiling/ wall, includingsingle core cable and earthing etc. as required.connection with 1.5 sq. mm FR PVC insulated, copper conductor,
209Supply and fixing 20 Amp SPN, Industrial type socket outlet with plug top and metal chained cover in sheet enclosure ( for Geyser).
210Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for Single pole inductive load ofpoles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
211Supplying and fixing of 40 amps rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
212Providing and fixing 100 A, 16 KA,TP MCCBrating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
213Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
214Supplying and fixing of 4 way, (4+12), double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
215Earthlings with copper earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe pf2.7 metre long etc with charcoal/coke and salt as required.
216Supply, laying and testing cable XLPE Insulated ,screened, PVCbedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core.
217SCHEDULEOF CREDIT : Old unserviceable wiring for light /fan/exhaust/call bell points complete of any size and any type.
218Old unserviceable wiring for circuit/Submain wiring along with earth wire complete of any size and any type.
219Old unserviceable DB comlete of any size and any type.
220Old unserviceable MCB/MCCB of any size and any type.
221Old unserviceable LED tube light fittings complete of any size and any type.
222Old unserviceable earthing plate and including strips.
223Old unserviceable Armoured electric power cable any type.
224SCHEDULE ‘E’ PART -I (Special repair and replacement of Leaking pipe line and allied works to Type -II accn at Bn KLP at Kashirambasti (Bldg No. DSP/816 A &B, 852, 823, 824, 825, 826, 847, 845 & 846)
225Providing and fixing (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 15mm dia.
226Providing and fixing 20 mm CPVC pipe having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. 20 mm dia CPVC pipe.
227Providing and fixing 25 mm CPVC pipe having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.25 mm dia CPVC pipe.
228Providing and fixing gun metal gate valve 25 mm with CI wheel of approved quality (screw end).
229Providing and fixing brass stop cock of approved quality 20 mm bore.
230Providing and fixing CP brass bib cock 15 mm dia of approved quality conforming to IS : 8931.
231Providing and fixing ball valve (brass) of approved quality high or low pressure, with plastic floats complete 25 mm bore.
232Supply and fixing of 500 Ltr capacity Polyethylene Water Storage tank with cover and suitable locking arrangement.
233Providing and fixing water closet squatting pan (Indian WC pan) with 100 mm cert iron P or S trip 10 ltr low level white PVC flushing cistern, including flus pipe conforming to IS: 7231 with all fitting and fixtures complete including cutting and making good the wall – white vitreous china Orissa pattern WC Pan of size 580 x 440 mm with integral type foot rests.
234Providing and fixing wash basin with CI brackets 15 mm CP brass pillar taps, 32 mm CP brass waster of standard pattern including painting in brackets, cutting and making good the wall. Wherever, required white vitreous china wash basin size 630 x 450 mm with a single 15 mm pillar top.(Block No. 08, 09, 10 & 11)
235S & F Semi rigid PVC waste pipe for sink hard wash basin 32 mm dia with length not less than 700 mm i/c PVC waste fittings complete.
236Providing and fixing CP brass angle valve for basin mixer of approved quality conforming IS: 8931.15 mm dia.
237SCHEDULE OF CREDIT : Old unserviceable 15 mm bore GI Pipes.
238Old unserviceable 20 mm bore GI Pipes.
239Old unserviceable 25 mm bore GI Pipes.