| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,(fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for issue under Schedule of credit and making good disturbed surfaces of walls, floors, etc. |
| 2 | Taking down MCB DBs/ SFUs |
| 3 | M & L for point wiring with 1.5 sq mm single core FRLS PVC insulated cable 1100 V grade with multistranded copper conductor drawn through PVCcasing and capping with all accessories fixed to wall /roofs ceiling etc and incl provision of 1.5 sq mm PVC insulated and unsheathed copperconductor as earth continuity conductor and connected to common earth dolly incl fabricated steelterminal box made out of 1.6 mm thick MS sheet concealed in the wall with 3 mm thick laminated sheet top cover / PVC Switch Board mounted on wallfor mounting the switches , socket outlets , fan regulators etc all as s specified and directed for following (a) One light/Fan point controlled by one switch. |
| 4 | One socket 3 pin outlet 5 amp on independent board. |
| 5 | One 3 pin socket outlet 5 amp on the same board board with other switches. |
| 6 | One bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size. |
| 7 | All as per item no 6 here-in-before but with copper conductor cable for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm. |
| 8 | S&F in repairs switch piano flush type single pole one way 5 amp. |
| 9 | S&F in repairs ceiling rose three terminal/PVC polycarbonate, isolated body complete all as specified. |
| 10 | S&F in repairs switch socket combination 2 in 1, 3 pin 5/15 amp flush type.. |
| 11 | S&F in repairs switch socket combination 2 in 1,5 amp flush type. |
| 12 | S&F in repairs socket outlet 2 in 1, 3/5 pin 5 amp multi purpose, flush type. |
| 13 | S&F in repairs switch bell push, flush type 5 Amp. |
| 14 | S&F in repairs bell, Multi music type AC, 230 Volts single pole. |
| 15 | S&F in repairs fan regulator electronic step type complete all as directed by EIC at site |
| 16 | Labour only for taking down and refixingwith repairs to Ceiling Fan with Fan regulator, Exhaust Fan,anyMake & any Sweep Oiling, Greasing , removing all dust with paintingand Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing for serviceable condition complete all as directed by Engineer-in-Charge. |
| 17 | S&F in repairsLED tube rod for LED Tube light fitting 18 Watt , complete with all accessories complete all as required at site and as directed by Engineer -in-Charge. Make : Cat No BLRB 20 CW LED of Bajaj or equivalent of Havell\"s/Philips / Wipro |
| 18 | S&F in repairsBattenfor LED Tube light 18 Watt fitting prewireed upto terminal block complete with all accessories and connecting up with twin core / .0076 flexible copper wire with and including LED tube light fixed on two nos PVC round / square mounting blocks complete all as required at site and as directed by Engineer -in-Charge. Make : Cat No BLRB DB 118 of Bajaj or equivalent of Havell\"s/Philips / Wipro . |
| 19 | S&F in repairs Surface mounted 36 watt 2 x 2 luminaire white powder coated CRCA housing with LEDs, Aluminium front frame with flat white high transmission acrylic cover complete with LEDs, driver and standard accessories including neccessary fixing arrangement complete all as required at site and as directed by Engineer -in-Charge. Cat No BCTBLR 36W LED FP CWof Bajaj or equivalent to Philips /CG. |
| 20 | Supply & fix in repairs 45 W pressure die cast aluminium housing LEDBuilding light secondary optics IP 66 protectionincluding connection with two core twisted copper flexible cable, Make - Bajaj, Cat No - ENXT P 54L WH CR PC SD or equivalent make of Havells /Philips/CG |
| 21 | Supply and fix in replacement of LED Tube light of 18/20 watt (4\") with batten integrated channel complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.Make:BajajCAT Part No BCLAB 20W WH LED P (4ft)or equivalent to CG/Philips/Wipro complete all as specified and directed . |
| 22 | Supply and fix in replacement of LED Tube light of 10 watt (2\") with batten integrated channel complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.Make:BajajCAT Part NoBCLSB 10 WH (2ft)or equivalent to CG/Philips/Wipro complete all as specified and directed . |
| 23 | S&F in replacement vertical type DB ,(VTPN) suitable for and including MCCB 4 pole, 125 amps, 16KA as incoming (compact) Earth and neutral bus bar of capacity upto 200 amp 4 ways,IP 43 protection , shrouded neutral bar & pan assembly with flexible connecting link in the wall with suitable nut and boltincluding matching the existing surfaceall as specified and directed , |
| 24 | S&F in replacemen MCB DB SPN 4 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surfaceall as specified and directed |
| 25 | S&F in replacemen MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surfaceall as specified and directed |
| 26 | S&F in repairs MCB DB SPN 12 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surfaceall as specified and directed |
| 27 | S&F in repairs MCB C Curve SPN 40-63 amps, 240 Volts, Complete all as specified and directed. |
| 28 | S&F in repairs MCB C Curve SP 6 to 32 amps single pole 240 Volts, Complete all as specified and directed. |
| 29 | S&F in repairs MCCB FP 200 Amps 36kA 415 V , with adjustable thermal and adjustable magnetic release, Complete all as specified and directed. |
| 30 | Taking down sub main wiring of any size from the ceiling, walls etc and incl making good to disturb surface of wall and match with the existing surface. |
| 31 | M&L for sub main wiring drawing through PVC casing and capping with two single core 4 sq mm and one run of 4 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts gradeall as directed. Note:- Three run of 4 sqmm wire and One run of PVC casing caping will be measured as one running meter. |
| 32 | M&L for sub main wiring drawing through PVC casing and capping with four runs of single core 6 sq mm and two runs of 6.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts gradeall as directed.Note:- Four run of 6 sqmm wire and Two run of 6 sqmm wire and One run of PVC casing caping will be measured as one running meter. |
| 33 | Supply and fix in repairs Triple pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating upto 32Apms |
| 34 | Supply and fix in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating upto10/20 Apms |
| 35 | Supply and fix new adore LED lamp 5 Watt confirming to Cat No LhLDeroemD9X005 of Havell\"s or euivalent in Philips / Bajaj |
| 36 | Supply and fix new adore LED lamp 9 Watt confirming to Cat No LhLDeueCnL8r009 of Havell\"s or euivalent in Philips / Bajaj |
| 37 | Supply and fix new adore LED lamp 15 Watt confirming to Cat No LhLDeueCnL9r015 of Havell\"s or euivalent in Philips / Bajaj |
| 38 | Dismantling the existing energy Meters, MCCB / MCB Distribution boards by disconnecting the eletric supply connection and refixing at new or same location after carrying out repairs / replacement , reconnecting complete all as directed by EIC at site. |
| 39 | Supply and fix in repairs modular switch oneway 6 Amps, 1 module complete all as specified and as directed. |
| 40 | Supply and fix in repairs modular socket6 Amps, 2/3 pin combined 2 module complete all as specified and as directed. |
| 41 | Supply and fix in repairs modular socket 6 Amps/16 Amps, 2/3 pin combined 2 module complete all as specified and as dirceted. |
| 42 | Supply and fix in repairs modular switch 1 way 16 Amps, 1 module complete all as specified and as directed. |
| 43 | Supply and fix in repairs modular bell push 6 Amps, 1 module complete all as specified and as directed. |
| 44 | Supply and fix in replacement Electronic ballast suitable for 1x36/40 Watt tube light fitting complete all as specified and as directed. |
| 45 | Supply and fix in replacement Electronic ballast suitable for 1x18/20 Watt tube light fitting complete all as specified and as directed. |
| 46 | Supply and fix in replacement Electronic ballast suitable for 1x28 Watt tube light fitting complete all as specified and as directed. |
| 47 | Excavatioin in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and taking out soft/loose soil for laying of cable /erection of pole/stay pit excavation |
| 48 | All as per Sl item No 1 herein before but in hard/dence soil |
| 49 | M&L for crushed stone sand for cable cushoining laid in trenches for protection of cable |
| 50 | M&L for Returning and filling including spreading levelling watering and well ramming in layers not exceeding 25 cm |
| 51 | M&L for Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point |
| 52 | Supply and laying factory cast, unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches as specified and as directed. |
| 53 | Taking down under ground 1.1 KV (E) Grade LT cable of size upto 10 sqmm to 300 sqmm 3.5/4 Core frompole/trenches/walls / ducts etc., for carrying out repairs , relaying, rerouting, laying back through same / different route after carrying out repair / issue under schedule of credit all as directed by Engineer-in-Charge at site. |
| 54 | Supply laying and testing cable XLPE insulated screened PVC beded,galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 25 sq mm 4 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as specified and diercted. |
| 55 | All as per item no 54 here-in-before but of size 16 sq mm 4 core. |
| 56 | Supply laying and testing cable XLPE insulated screened beded,galvanized steel trip or wire armoured, electric power cables (heavy duty) 1100 Volt grade wiyh stranded aluminium conductor of size 25 sq mm 3,1/2 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as diercted. |
| 57 | All as per item no 56 here-in-before but of size 50 sq mm 3,1/2 core. |
| 58 | All as per item no 56 here-in-before but of size 70 sq mm 3,1/2 core. |
| 59 | All as per item no 56 here-in-before but of size 185 sq mm 3,1/2 core. |
| 60 | Supply and fix in repair indoor type cable end termination joint heat shrinkable type for 22 KV (E) Grade HT cable of size120 sqmm x 3 Core to 240 Sqmm x 3 Core and connecting the cable with the load and testing complete all as specified and as directed by Engineer-in-Charge at site.Make- Denson, Raychem, M-Seal |
| 61 | M&L for removing / dismantling existing burnt / defective 22 KV (E) Grade HT straight through joint and providing new straight through joint heat shrinkable type for 22 KV (E) Grade HT XLPE cables of size120 sqmm x 3 Core to 240 Sqmm x 3 Core Sqmm complete all as specified and as directed by Engineer-in-Charge at site. |
| 62 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4core XLPE,armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type |
| 63 | All as per item No 62 here-in-before butfor cable of size 70 to 95 sq mm. |
| 64 | All as per item No 62 here-in-before butfor cable of size 185 sq mm. |
| 65 | M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to GI strip using 32x6mm galvanised iron strip, means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 5 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover. |
| 66 | M&L for providing stone aggregate 40 mm forsubstation premises including cleaning of substation complete all as specified and as directed at site by Engineer in Charge . |
| 67 | M&L for Filterationand dehydration of transformer oilthrough filteration and dehydration machine by means of continuous circulation of transformer oil through filteration and dehydration machine till dielectric strength of the oil is achieved up to 50 KV for one minute at 4 mm gap and oil is completely filtered. Note: 1.Oil samples are to collected from top and bottom of oil tank and test results to be submitted for each sample before and after filteration. |
| 68 | Supply and topping up /replacement of newtransformer oilof dielectric strength 50 KV at 4mm gap in transformers conforming to IS - 335 / 1983 of various cap installed in various locations .Make of Transformer oil: Power Oil / Indian Oil / AparNote : New Transformer oil in the transformer will be filled in the transformer only after filteration and dehydration of existing transformer oil of the transformer. (b) Transformer oil shall be supplied in sealed barrel with test result and test cert. |
| 69 | M&L for disconnection of electric supply, dismantling thetop cover, carefully, taking out old gasket and replacement of the same with and including new cork sheet, cleaning of the conservator tank, breather assembly, replacement of silica gel, oil level looking glass, bushings, gasket, nuts, bolts, washers etc. including connecting up completefor Tranformers22 / 0.433 kV of different capacitiesall as directed by Engineer-in-Charge.Note:Spares required for replacement will be measured and paid separately under respective item except 6 mm thick tope cover cork sheet gasket. |
| 70 | M&L for Scrubing of old rusted paint from transformer and preparation of surfaces for fresh painting.Painting of transformer by means of spray painting with two coats of synthetic enamel paint of approved colour of transformer up cap 25 KVA to 315 KVA and writing SM NO/MES NO of the transformer. |
| 71 | Supply only S/S Nut, bolts, washers of required sizes. |
| 72 | M&L for scrubbing down the old patchy / blistered paint of the outdoor type LTPanel / feeder Pillar Box of size not exceeding 2.5mtr x 2.5 Mtr x 0.60 Mtr and painting all the metal parts inside and outside of doors with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer after carrying out repairs / replacement to the door hinges ./ locks, welding the broken doors complete all as directed by Engineer-in Charge at site. |
| 73 | M&L for removing the old burnt out wires, cleaning the panel compartments, cleaning the contacts with CTC spray, carrying out repairs to the old unsv burnt out control wiring / panel wirng of the LT Pane;l / feeder Pillar with copper conductor cable provided with multistranded copper conductor cable terminated with thimbles / lugs, connecting up complete all as directed by Engineer-in Charge at site. |
| 74 | S&F in replacement of MCCB 415 Volt 16 KA, 4 Pole 63 Amps capacity. Complete all as specified and directed by Engineer-In-Charge. Make:ABB/Siemens/Hager. |
| 75 | All as per item No. 74 here-in-before but160A, 25KA. Complete all as specified and directed by Engineer-In-Charge. |
| 76 | All as per item No. 74 here-in-before but 250A, 36KA. Complete all as specified and directed by Engineer-In-Charge. |
| 77 | All as per item No. 74 here-in-before but350A, 36KA. Complete all as specified and directed by Engineer-In-Charge. |
| 78 | M& L for disconnection of electric supply and earthing connections, sealing the ends, transporting the transformer to civil workshop, dis-assembling into various components, lifting the core and winding, dismantling the core, removing burnt winding, reassembling / laminating the core, rewinding of the burnt out / unserviceable winding on secondary HT side only for all the three phases, varnishing with insulating varnish of approved / specified thickness, baking / drying out in oven for apropriate time, reassembling the transformer complete with and including replacement of HT/LT Bushings, 6 mm thick cork sheet for bushings, top cover gasket, carrying out HV/LV/ Insulation/ Impedance/Loss test ex-factory as per latest IS, transporting back to MES installation, carrying out precommissioning test, and connecting up complete all for satisfactory functioning of the transformer all as specified and directed by E-in-Charge at site for 22/0.433 KV transformers of capacity upto315 KVA |
| 79 | S&F HT 22 KV Barrel fusesof capacity 15 Amps complete all as specified and as directed. |
| 80 | All as per item no 85 but for 10 Amp |
| 81 | M&L for defect rectification HT/LT cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additionalexcavation in normal alluvial strata required forexposing the cable fault ; removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 240 Sq mm 3 core & LT cable of size upto 240 Sqmm. The fault locating equipments will be brought to site within the hours of instruction from Engr-in-Charge as specified |
| 82 | Supply and fixFR PVC insulated cable 1100 V grade with multistranded copper conductor of size 1.5 Sqmm3 core conductor all as s specified and directed by Engineer-In -Chargeat site |
| 83 | Supply & fix in replacement of LED street light of 70 watt along with fixture.Make:BajajCAT Part No ENXT P 84L WH CR PC SD or equivalent to CG/Philips/Wipro complete all as specified and directed |
| 84 | Supply & fix in replacement of LED Flood Luminaire of 100 Watt (MAGNUM)with high pressure die cast aluminium housing with IP 65 Protection .Make:BajajCAT Part No BJFL 100W LED S or equivalent to CG/Philips/Wipro complete all as specified and directed |
| 85 | Supply & fix in replacement of SPD up to 50 KA complete all as specified and as directed .Make:Bajaj or equivalent to CG/Philips/Wipro. |
| 86 | Supply & fix in replacement of LED DRIVER for 45 to 150 watt street light fitting complete all as specified and as directed .Make:Bajaj or equivalent to CG/Philips/Wipro. |
| 87 | Taking down streetlight fitting/ security lights / Building any type from pole /wall and refix the same in its own position including repair and replacement of unserviciable parts and testing complete .NOTE :-(i)Spares required to be replaced will be measured and paid separatel under respective item of Sch A.(ii) Rates quoted shall be deemed to include the cost of minor spares not catered for in the subject CA. |
| 88 | Dismantling the unserviceable stator coil assembly from the 62.5 KVA DG SetAlternator transporting the same to the workshop to carry out the following repairs:-(a) Stripping down the old burnt copper winding and rewinding the same with same size of super enameled copper wire, replacing the insulation paper sheet after properly cleaning the slots and providing appropriate impregnated insulation material including varnishing the complete assembly with class \"E\" insulation and baking the same in an oven, reassembling and refixing stator cover with new nut bolts transporting and installing the repaired equipments to the site with final testing complete all as specified.(b)Removing the old unserviceable terminal box connecting wires with lugs and refixing with new terminal box with connecting wires and copper lugs and terminal nut bolts(c ) Removing the unserviceable RRA Diode assembly and Coupling rubber bush and providing the new rubber coupling bush complete all as specified.(d) Replacement of shaft seal of drive shaft.(e)Repair/Replacement of Voltage control unit (AVR) including necessary repair and also replacement of rectifier and testing complete(f) Removing the fuel injector Pump from the engine, for servicing, overhauling including replacement of \"O\" Rings and Washers and reassembling/refixing in position and testing.Also servicing the fuel injectors andreplacing the washers and \"O\" Rings reassembling and calibration of fuel injector and refixing in position and testing complete all as specified and directed. |
| 89 | Replacement of old UNSV filters wth new filters with rubber \"O\" ring complete all as specified followingDG Sets:-(a) 62.5 KVA (Air Force / Tropo)(i) Fuel Filter |
| 90 | (ii)Lub Oil Filter |
| 91 | (iii)By pass oil filter |
| 92 | (iv)CR filter plate & \"O\" ring |
| 93 | (v)Air filter (inner and outer) |
| 94 | M&L for dismantling of radiator complete from DG Sets cleaning / scraping from outside of the radiator, cleaning of all copper tubes of radiator with descalling solution from inside & out side with forced feed method (by using separate chemical pump, water pump & compressor) also plugging of all leakage by welding, brazing of copper tubes, cleaning of fins and replacement of gaskets etc for the following capacities of DG Sets:- (a) 62.5 KVA |
| 95 | S & F and topping up of lubricant oil of various capacity of DG sets at various location under GE (I) (Navy) Lonavla complete as as specified and directed by Engr-in-Charge (Note - 1. Old decanned oil included in the credit schedule) |
| 96 | M&L for cleaning of Sump including replacement of sump gasketof the following capacities of DG Sets:-(a ) 62.5 KVA |
| 97 | S & F 150 AH 12V battery of Maintenance free suitable for DG sets as fixed in repairs complete all as specified and directed by Engr-in-Charge Make - Exide / Amron / Cummins / Greaves Cotton / Luminous |