| 1 | Supply and fix hermatic sealed new uncut compressor unitof window type / split type ACs of 1.5 TR capacity including wiring as required including flushing out system, vaccumising, checking and rectification of leakage, gas charging and testing after completion of work at site/ MES Store Yard for satisfactory functioning including taking out unserviceable compressor unit complete all as specified and directed.NOTE: - The new compressor unit shall be suitable as per existing make & model ofA/C and no additional charges shall be claimed by contractor for different model of A/Cs |
| 2 | All as per srl Item No 1 but for 2.0 TR Split/window air conditioner unit. |
| 3 | S&F in repair blower motor of indoor unit 0.5 HP of speed 900 RPM of Split Air conditioner 1.5 /2.0 TR capacity as per existing make complete all as specified and directed. |
| 4 | S&F condensor cooling fan motor of speed 900 RPM of Split Air conditioner of capacity 1.5/2 TR including taking down old condensor cooling fan motor complete all as specified and directed. |
| 5 | S&F Fan blade of condensor fan motor of Split Air conditioner of capacity 1.5/2.0 TR including taking down old fan blade complete all as specified and directed. |
| 6 | S&F condensor and evaporator cooling fan motor of speed 900 RPM of window Air conditioner of capacity 1.5/2 TR including taking down oldfan motor complete all as specified and directed. |
| 7 | S&F annular type rotor fan blade of condensor and evaporator fan motor of window Air conditioner of capacity 1.5/2.0 TR including taking down old fan blade complete all as specified and directed. |
| 8 | S&F running capacitor (clip type) 36 MFD, 240 volts 50 cycles for window/splittype air conditioner 1.5/ 2.0 TR capacity, water cooler, refrigerator, deep freezer including taking down old capacitor complete all as specified and directed. |
| 9 | S&F Starting capacitor (clip type) 80-100 MFD, 240 volts 50 Hz forwindow/splittype air conditioner 1.5/ 2.0 TR capacity, water cooler, refrigerator, deep freezer including taking down old capacitor complete all as specified and directed. |
| 10 | S&F Over load protector relay model No 1622 / 2085 for 1.5/2.0 TR capacity window type AC including taking down old protector complete all as specified and directed. |
| 11 | S&F thermostat switch for window/splittype AC 1.5/2.00 toncapacity including taking down old thermostat complete all as specified and directed. |
| 12 | S&F in repair defective wiring set (with necessary PCB) of window/splittype AC 1.5/ 2 Ton capacity complete all as specified and directed. |
| 13 | S&F cooling coil for window/split type AC 1.5 /2.0 ton capacity including taking down old coil complete all as specified and directed. |
| 14 | S&F condensor unit suitable for window/split type AC 1.5 ton capacity including taking down old condensor unit complete all as specified and directed. |
| 15 | M & L for flushing out system, checking and rectification of leakages if any and make it serviceable including gas charging with refrigerant R-22/R-134Ain compressor for window type AC / Split type AC capacity 1.5/2.0 TR complete all as specified and directed. |
| 16 | Taking out or in situ servicing of window/split type AC of any capacity including cleaning with air blower, cleaning and washing fins of cooling coil with soap water, taking out all dirt, sludge deposited, cleaning of air filter including oiling / greasing of condensing fan motor complete all as specified and directed .Note: Any damage occurred during servicing for which contractor will be responsible to rectify the same without any extra cost to the Govt. |
| 17 | S&F capacitor 6 MFD suitable for window/split type AC, water cooler of 40/80 ltr capacity including taking down old capacitor complete all as specified and directed. |
| 18 | S&F capacitor 4 MFD suitable for 1.5 ton capacity split/window type AC / Desert Cooler including taking down old capacitor complete all as specified and directed. |
| 19 | S&F annealed copper tube for connection from indoor unit to oudoor unit of suitabe size including necessary cutting, flaring of tube and testing of leakage after connection including foam type insulation all around the copper tube for split AC units including taking down old copper tube complete all as specified and directed. |
| 20 | S&F hermatic sealed new uncut compressor for refrigerator 310/286 Ltr, capacity with suitable relay and over load as per the company scheme supplied by the manufacture including flushing out system, checking and rectification of leakage, gas charging and testing after completion of work at MES store yard including taking out old compressor complete all as specified and asdirected.Note: - (1) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete, relay and over load if required will be measured and paid separately under relevant items. |
| 21 | All as per srl Item no 20 above but for refrigerator 165/170/180/190 Ltr capacity. |
| 22 | S&F relay suitable for 286/310 Liters capacity refrigerator Cat. No. MLA-043 including taking down old relay complete all as specified and directed. |
| 23 | S&F for relay suitable for 165/170/180 Liters capacity refrigerator Cat. No. MLA-042/033 including taking down old relay complete all as specified and directed. |
| 24 | S&F thermostat automatic \"R\" frost with knob suitable for 165/170/180/286/310 liters capacity refrigerator including taking down old thermostat complete all as specified and directed . |
| 25 | S&F in repair door gasket of best quality suitablefor 286/310 liters capacity refrigerator complete including taking down old gasket complete all as specified and directed . |
| 26 | S&F in repair door gasket of best quality suitablefor 165/170/180 liters capacity refrigerator complete including taking down old gasket complete all as specified and directed . |
| 27 | S&F in repair bulb with pin /screw type, 230 Volts suitable for 165/170/180/190/286/310 Ltrs capacity refrigeratorincluding taking down old one complete all as specified and directed . |
| 28 | S&F in repair freezer door including necessary door springs, screws etc. for 165/170/180/190 Ltrs. capacity refrigerator including taking down old door complete all as specified and directed . |
| 29 | S&F in repair door lock with 02 Nos keys suitable for any Capacity refrigerator, including taking down old key complete all as specified and directed . |
| 30 | S&F in repair PVC chill tray suitable for 286/310 Ltrs capacity refrigerator of matching colour or tintincluding taking down oldtray complete all as specified and directed . |
| 31 | S&F in repairPVC chill tray suitable for 165/170/180/190 Ltrs capacity refrigerator of matching colour or tintincluding taking down oldtray complete all as specified and directed . |
| 32 | S&F in repair Refrigerator door handle suitable 165 to 310 ttrs capacityincluding taking down oldhandle complete all as specified and directed. |
| 33 | M & L for Flushing out system, checking and rectification of leakages if any and makingit serviceable including gas charging with refrigerant R-22/R-134 Afor 286/310 Ltr capacity refrigerator complete all as specified and directed. |
| 34 | All as per srl item No 33 above but for refrigerator 165/170/180/190 Ltr capacity complete all as specified and directed. |
| 35 | S&F in repair freezer assembly/evaporator coil 286/310 Ltrs capacity refrigerator including gas charging and taking down oldassemblycomplete all as specified and directed.Note: The rate quoted shall be included the cost of gas charging including vaccumizing of the system. |
| 36 | All as per srl Item No 35 above but for refrigerator of 165 to 190Ltrs capacity complete all as specified and directed. |
| 37 | S&F in repair condensor unit of refrigerator capacity 286/310 ltrs includingjointing/ brazingof tubes andtesting including taking down oldunitcomplete all as specified and directed. Note:The rate quoted shall be included the cost of gas charging including vaccumizing of the system. |
| 38 | All as per srl Item No 37 above but for refrigerator of 165 to 190Ltrs capacity complete all as specified and directed. |
| 39 | S&F in repair hermatically sealed new uncut compressor suitable forwater cooler of capacity 40/80 litrsincluding gas charging, flushing out system, checking and rectification of leakage and testingincluding taking down old compressor complete all as specified and directed.Note: - (1) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete. |
| 40 | All as per srl Item No 39 above but for water cooler of 60/120 Ltrs capacity complete all as specified and directed. |
| 41 | S&F in repair copper filter and capillary tube of water cooler/splitAC/window AC/ refrigerator/ deep freezer of any capacity including taking down old filter and capiliary tubecomplete all as specified and directed. |
| 42 | S&F in repair relay with over load protectors suitable for 40/80 or 60/120Ltr capacitywater cooler including taking down old relay complete all as specified and directed. |
| 43 | S&F in repair condensor fan motor HP- 1/32, RPM-1300 with fan blade suitable for water cooler of capacity 40/80 ltrs or 60/120 ltrs capacity with clips or bracket for motor fixing including taking down old condensor fan motor complete all as specified and directed. |
| 44 | S&F in repair onlyfan blade for condensing fan motor suitable for water cooler ofcapacity 40/80 or 60/120 Ltr including taking down old fan bladecomplete all as specified and directed. |
| 45 | S&F in repair thermostat switch with knob for water cooler of capacity 40/80 or 60/120 Ltrsincluding taking down old thermostat switch complete all as specified and directed. |
| 46 | S&F in repair drip tray made out of 24 gauge stainless steel sheet 30x12x5 cm deep with necessaryPVC connection for draining of water cooler of 40/80 or 60/120 litrecapacity including taking down old tray complete all as specified and directed. |
| 47 | S&F in repair rubber beading fixed to top cover of water cooler of 40/80 or 60/120 litre capacity including taking down old beading complete all as specified and directed. |
| 48 | S&F in repair push cock, 15mm bore made of brass chromium plated self closing for water cooler of 40/80 or 60/120 litre capacityincluding taking down old cock complete all as specified and directed. |
| 49 | S&F in repair brass float valve 15mm bore with PVC float ball (ISI Marked) with check nut / socket / GI nipple for water cooler of 40/80 or 60/120 litre capacity including taking down old float valve complete all as specified and directed. |
| 50 | S&F in repair top cover of water cooler with rubber beading,hinges,screws etc suitable for water cooler of capacity 40/80 or 60/120 Ltrs.capacity including taking down old top covercomplete all as specified and directed. |
| 51 | M&L for Flushing of system, testing and repairs of leakages in system, charging of Gas as per exising R-22, R134A etc including testing of water cooler of 40/80 or 60/120 ltr capacity complete all as specified and directed. |
| 52 | S&F in repair condenser unit complete suitable for 40/80 Ltr capacity water cooler including gas charging, flushing out the system, brazing, welding and jointing the suction reed and discharge reedincluding taking down old condensor unit complete all as specified and directed. |
| 53 | All as per srl Item Sl No 52 but water cooler of capacity 60/120 ltr. |
| 54 | S&F in repair hermatic sealed new uncut sealed compressor ofdeep freezer 500 Ltr, capacitywith suitable relay and over load as per the company scheme supplied by the manufacture including flushing out system, checking and rectification of leakage, gas charging and testing after completion of work at MES store yard including taking down old compressor complete all as specified and asdirected.Note: - (1) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete, relay and over load if required will be measured and paid separately under relevant items. |
| 55 | All as per srl Item No 54 above but for deep freezer 320/200 Ltr, capacity complete all as specified and asdirected. |
| 56 | S&F in repair relay suitable for 200/320 Ltrs capacity deep freezer including taking down old relay complete all as specified and directed. |
| 57 | S&F in repair relay suitable for 500 Ltrs capacity deep freezer Cat. No. MLA-042/033, including taking down old relay complete all as specified and directed. |
| 58 | S&F in repair thermostat automatic \"R\" frost with knob suitable for 200/320/500 liters capacity deep freezer including taking down old thermostat complete all as specified and directed . |
| 59 | S&F in repair door gasket of best quality suitablefor200/320 Ltrs capacity deep freezercomplete including taking down old gasket complete all as specified and directed . |
| 60 | S&F in repair door gasket of best quality suitablefor500 Ltrs capacity deep freezercompleteincluding taking down old gasket complete all as specified and directed . |
| 61 | S&F in repair condensor unit of deep freezer capacity 200/320 ltrs including gas charging with R-22 or R-134 A as per existing and jointing of tubes by brazing andtesting including taking down old condenser unit complete all as specified and directed. |
| 62 | S&F in repair condensor unit of deep freezer capacity 500 ltrs including including gas charging ith R-22 or R-134 A as per existing and jointing of tubes andtesting including taking down oldunitcomplete all as specified and directed. |
| 63 | M&L for Flushing out system, checking and rectification of leakages if any and gas charging with refrigerant R-22 or R-134 A as per existing and testing after gas charging and making it serviceable of deep freezer capacity 200/320 ltrs complete all as specified and directed. |
| 64 | All as per srl Item Sl No 63 but deep freezer of capacity 500 ltr. |
| 65 | S&F in repair condensor fan motor of speed 1300 RPM with fan blades suitable for deep freezer capacity 320 ltrs with necessary clips or bracketfor motor fixing including taking down old condensor fan motor complete all as specified and directed. |
| 66 | All as per srl item No 65 but deep freezer of capacity 500 ltrs. |
| 67 | M&L for Repairs to 5 KVA voltage stabilizer single phase input 130 to 250 Volts, out put voltage stabilizer 230 V including replacement of worn out / short circuit /pointed circuit board, voltmeter, 15/5 Amp socket, relay etc, testing complete all as specified and directed. Note : Cost of replacement Parts shall include in quoted rates. |
| 68 | All as per srl Item No 67 above but of stabilizer of capacity 3 KVA complete all as specified and directed. |
| 69 | S&F in repair front grill (moveable) of the Desert Cooler made out of 20 gauge PGI sheet including provn for selector switch with knob, indicator etc suitable for 4000/5000 cfm desert cooler including taking down old grillcomplete all as specified and directed. |
| 70 | S&F in repair desert cooler fan motor capacity 1/5 HP three speed, 1400 RPM single phase with fan blade, standwith copper windingincluding taking down old motor complete all as specified and directed. |
| 71 | S&F in repair submersible pump of discharge head 2.5 Mtr 220-240 volts AC supply single phase 40 wattincluding taking down old pump complete all as specified and directed. |
| 72 | S&F in repair Wood / wool chips pad for Desert Cooler of size 600 x 550 x 30mm (set of three pads) superior quality complete all as specified and directedincluding taking down old pads complete all as specified and directed. |
| 73 | S&F in repair supporting jali to wood / wool chips pad set made out of hard MS wire and fitted inside louvers (set of three)complete all as specified and directedincluding taking down old jali complete all as specified and directed. |
| 74 | S&F in repair selector switch with knob three speed suitable for fan motorincluding taking down old switch complete all as specified and directed. |
| 75 | S&F in repair PVC insulated and PVC sheathed cable copper conductor 3 core 23/0.0076 cross sectional area (superior quality)including taking down old cable complete all as specified and directed. |
| 76 | S&F in repair PVC water distributor of 3 out lets withMS nuts & boltsincluding taking down old one complete all as specified and directed. |
| 77 | S&F in repairPVC elbow suitable for desert coolerincluding taking down old elbow complete all as specified and directed. |
| 78 | S&F in repair PVC pipe 15mm dia heavy duty for Desert Cooler Pumpincluding taking down old pipe complete all as specified and directed. |
| 79 | S&F in repair plug top 3 pinof capacity 5 Amp AC 240 Volts 50 Hzincluding taking down old plug top complete all as specified and directed. |
| 80 | S&F in repair motor fixing ring with eight screw (clip type) for desert cooler including taking down old one complete all as specified and directed. |
| 81 | M & L for spray painting to old steel surfaces of Desert cooler up to 5000 cfm with two coatsof synthetic enamelpaint over one coat of red oxide primer on external surface and two coats of anti-corrosive black paint over a coat of red oxide primer on inside the body tank and side grillsincluding scraping / rubbing with wire brush on old surface of Desert cooler and writing MES No. etc complete all as specified and directed. |
| 82 | M&L for submain wiring with two runs of 6 sqmm with one run of 6 Sqmm earth wire of 1100V grade FRLSPVC insulated multi-stranded copper conductor, single core cable conforming to IS 694 drawn through and including 20mm dia PVC conduitwith accessoriesfixed on wall / ceiling with PVC saddles and cadmium plated steel screws and connected to common earth dolly including taking down old submain wiringcomplete all as specified and directed.Note :- Three runs of 6 sqmm and one run of PVC conduit pipe shall be measured as one length for the purpose of measurement. |
| 83 | M&L for single pole and neutral enclosure with 2 pin earth industrial plug and socket with one MCB SP 20 Amps including taking down old one complete all as specified and directed. |