Tender For Repairs / Maintenance Of External Electric Supply System Lt Panels Earthing, Lt Ug Cable, Lt Cable Joint, Apfc Panel Earthing And Connected Accessories At Ins Shivaji Lonavla, lonavla-Maharashtra

Military Engineer Services-MES has published Tender For Repairs / Maintenance Of External Electric Supply System Lt Panels Earthing, Lt Ug Cable, Lt Cable Joint, Apfc Panel Earthing And Connected Accessories At Ins Shivaji Lonavla. Submission Date for this Tender is 28-11-2023. Electrification Work Tenders in lonavla Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

40462822
Corrigendum : Tender For Repairs / Maintenance Of External Electric Supply System Lt Panels Earthing, Lt Ug Cable, Lt Cable Joint, Apfc Panel Earthing And Connected Accessories At Ins Shivaji Lonavla
Open Tender
Indian
Maharashtra
lonavla
28-11-2023

Tender Details

Tender For Repairs / Maintenance Of External Electric Supply System Lt Panels Earthing, Lt Ug Cable, Lt Cable Joint, Apfc Panel Earthing And Connected Accessories At Ins Shivaji Lonavla

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Nov-2023 Amendment to tender comments Other 21-11-2023
2 21-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:REPAIRS / MAINT OF EXTERNAL ELECTRIC SUPPLY SYSTEM LT PANELS EARTHING, LT UG CABLE, LT CABLE JOINT, APFC PANEL EARTHING AND CONNECTED ACCESSORIES AT INS SHIVAJI LONAVLA (8914/E8)
Sl. No. Item Description
1Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in hard/dense soil for laying of cable trenches all as specified and directed.
2All as per item No.01Herein before but in hard dense soil
3Returning filling in, including spreading, levelling, watering and well ramming in layer not exc 25cmall as specified.
4Removal of surplus soil(excavated soil) to distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point and all specified.
5M&L for providing dry river sand / crush stone dust for cushioning to UG cable including punning down of sand in layers all as specified. Note :- Cushioning will be measured and paid after punning down.
6Supply and laying factory cast, unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches as specified and as directed.
7Taking down under ground 1.1 KV (E) Grade LT cable of size upto 10 sqmm to 300 sqmm 3.5/4 Core frompole/trenches/walls / ducts etc., for carrying out repairs , relaying, rerouting, laying back through same / different route after carrying out repair / issue under schedule of credit all as directed by Engineer-in-Charge at site.
8Supply laying and testing cable XLPE insulated screened beded,galvanized steel trip or wire armoured, electric power cables (heavy duty) 1100 Volt grade wiyh stranded aluminium conductor of size 10 sq mm 2 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as diercted.
9All as per item no 8 above but of size 16 sq mm 4 core.
10All as per item no 8 above but of size 25 sq mm 3.5 core.
11All as per item no 8 above but of size 50 sq mm 3,1/2 core.
12All as per item no 8 above but of size 70 sq mm 3,1/2 core.
13All as per item no 8 above but of size 95 sq mm 3,1/2 core.
14All as per item no 8 above but of size 120 sq mm 3,1/2 core.
15Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4core XLPE,armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type
16All as per item No 15 above butfor cable of size 70 to 95 sq mm.
17All as per item No 15 above butfor cable of size 120 sq mm.
18All as per item No 15 above butfor cable of size 300 sq mm.
19Supply and lay in trenches / along the wall / floor / on poles / pillars / for road / Nallah crossing,pipes GI light grade of size 100 mm dia with and including all fittings and accessories complete including taking down the old unsv all as specified and and directed for cable protection
20Supply and lay in trenches / along the wall / floor / on poles / pillars / for road / Nallah crossing,pipes GI light grade of size 50 mm dia with and including all fittings and accessories complete including taking down the old unsv all as specified and and directed for cable protection
21Supply and lay in trenches / along the wall / floor / on poles / pillars / for road / Nallah crossing,pipes GI light grade of size 40 mm dia with and including all fittings and accessories complete including taking down the old unsv all as specified and and directed for cable protection
22Cutting and filling with PCC (1:3:6) in bituminus roadas per direction of Engr in Charge for laying of UG cable and match the existing road to the existing system.
23M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.’25 mtr below normal ground level) with top edge of the plate not less 1.5 mtr below normal ground level connected to galvanized earth plate using galvanised iron strip 25×4 mm as earthing lead by means of suitable size of GI nuts, bolts, check nuts and washers all as specified in electrical plate SSR Part I including necessary .Exc & earth work, providing charcoal and salt dust layers and construction of PCC pit in 1:3:6 using 20 mm size graded stone aggregate, precast RCC 40 mm thick cover in 1:2:4 type B 1 with 12 mm dia steel MS plain bar, lifting handle GI pipe of 50 mm bore for earth lead protection andGI pipe 15 mm dia forwatering, with funnel and wire mesh including testing on completion. All as specified and as directed incl dismentling existing unsserviciable earthing .
24Renewal/ Repairs toLT Panel Board ofany size completeas mentioned below:- (I) Repair/ replacement of damaged hinges of each compartment (ii) Taking down existing bus bars cleaning with CTC applying with becktol red solution, providing bus bar insulation and refixing with new s/s nuts, bolts, washers etc. (iii) Replacement of damaged copper flexible cable and fixing new copper flexible cable of suitable size for incoming and out going connections of each MCCBterminals to bus bars. (iv) Replacement of damaged/ worn out/ loose connections/ cable lugs for incoming & outgoing cables. (v) Replacement ofu/s CT"s, ammeters, Volt meters, Indication Lamps (01 Set each) including provision of new wiring for the same. Note : Ammeters and CT"s shall be wired with 2.5 sqmm copper wire. (vi) Replacement of neoprene gasket for all doors of panel board. Note : i)Cost for replacement of spares are deemed to be included in the quoted rates. ii)The rate shall be deemed to be included for replacement of worn out rusted, Channels, hinges, bolts, split pins and cable lugs, cable glands and neoprene gasket with painting to all doors including raising of foundation to 0.3 M height etc. iii) Cost of replacement of MCCB"s, Repairs to ACB"s notincluded in the scope of work.
25S&F in replacement of MCCB 415 Volt 16 KA, 4 Pole 63 Amps capacity. Complete all as specified and directed by Engineer-In-Charge. Make: Havells/Legrands/L&T
26All as per item No. 23 above but 100A, 25KA. Complete all as specified and directed by Engineer-In-Charge.
27S&F in replacement of MCCB 415 Volt 36 KA,Adjustable type, 4 Pole 160Amps capacity. Complete all as specified and directed by Engineer-In-Charge. Make:Havells/Legrands/L&T
28All as per item No. 27 above but200A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
29All as per item No. 27 above but 250A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
30All as per item No. 27 above but350A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
31All as per item No. 27 above but 400A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
32All as per item No. 27 above but 500A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
33All as per item No. 27 above but 630A, 50KA. Complete all as specified and directed by Engineer-In-Charge.
34S&F in replacement of MCCB 415 Volt 36 KA,Adjustable type, 3 Pole 160Amps capacity. Complete all as specified and directed by Engineer-In-Charge. Make:Havells/Legrands/L&T
35All as per item No. 34 above but200A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
36All as per item No. 34 above but 250A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
37All as per item No. 34 above but350A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
38All as per item No. 34 above but 400A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
39S&F in replacement of MCCB 415 Volt 16 KA,fix type, 3 Pole 25-100 Amps capacity. Complete all as specified and directed by Engineer-In-Charge. Make:Havells/Legrands/L&T
40S&F in replacement of MCCB 415 Volt 16 KA,fix type, 3 Pole 125 Amps capacity. Complete all as specified and directed by Engineer-In-Charge. Make:Havells/Legrands/L&T
4115M & L for LT route marker made of50mm x50mmx 6 mm angle iron fix on PCC block of size 200 x 200mmx 200mm including indicating LT 1100V U/G Cable and fixing on ground above the cable of every 50 meter length.
42S & F Outdoor Type, weather and vermin proofBus bar panel made out of 2 mm thick stainless steel sheet includingfour pole 200 Amps MCCB 415 Volts 50 Hz with front opening and locking arrangement, 200 Amps capacity aluminium bus bar for phase, 3 No"s and 1 No200 Amp bus bar for neutral, mounted on epoxy insulator including neccessary copper control wiring, heat shrinkable, RYB coloured sleeves over bus bar for identification, earth shields, circular holes at bottom / top to receive incoming and outgoing cable, cable lugs, cable gland of sizes as required floor mounting angle iron frame made out mild steel angle iron of size 40 x 40 x 6 mm grouted on PCC (1:3:6) upto required heightall as specified and as directed by Engr-In-Charge .
43M&L for repairing of Capacitor (APFC ) panel of 200KVR carryout repairs as A .1) Supply & Fix only Time delay Timer suitable for APFC panel ,415Volts,50Hz AC supply in existing panel completeas specified and directed by Engr-in-charge Make: L&T/C&S/Schnieder/Havells/Selec -1 NO , 2)Supply & Fix only Auxilaury contactors 10Amps Capacitor duty with 8NO+8NC suitable for ,415Volts,50Hz AC supply in existing panel completeas specified and directed by Engr-incharge Make: L&T/C&S/Schnieder/Havells -2 NO . 3) S &F in repair of MCB,TP,C"Curve,415Volts,50Hz AC supply in existing panel with mounting rail complete as specified and directed by Engr-in-charge. 4 Supply & Fix only Power contactors Capacitor Duty(Type MOC of L&T) Capacitor duty with 2NO+2NC suitable for 415Volts,50Hz AC supply in existing panel completeas specified and directed by Engr-in-charge Make: L&T/C&S/Schnieder.5)Supply & Fix only APFC Relay, 12Stages digital type suitable for 415V, 3phase, AC supply and all specified and directed. Make L&T/ Syntron/Sycon 1 NO . 6)Supply & Fix only Capacitor bank, Heavy duty type,415Vots, SOHz AC supply in existing panel complete as specified and directed by Engr-in-charge. (make: Prabodhan/Epcos/Havells/schnieder . 7)Testing and repair/replacing of controle MCB capacity 6Amps 10 NOS . 8)Testing and repairing/ replacing of Indicating lamps LED type and push bottons. Checking and testing of all logical fuctions and commissioning the panel board . 9)Supply & Fix panel door lock of 20 mm -10nos.10) Supply& Fix current transformer 415 volt 15 VA burden accuracy class 1 suitable amps of CT for sensing accuracy for exciting panel & all as specified & directed. Make AE/MECO/c&S-1 NO, . 11) 3 Phase 96/96 VIF Meter .Make AE/MECO/c&s/SELEC -1 NO . 12)Testing & replaceing of A/M selector switch 10Amp MakeKeycee/L&T/SELEC 5 NOS . 13) Power wire single core 2.5SQMM,4SQMM,6SQMM, 10SQMM Make Polycab, Finolex, KEl -10 MTR EACH .
44All as per item No. 8 above but 150 KVAR ,Complete all as specified and directed by Engineer-In-Charge.
45All as per item No. 8 above but 100 KVAR ,Complete all as specified and directed by Engineer-In-Charge.
46All as per item No. 8 above but 50 KVAR ,Complete all as specified and directed by Engineer-In-Charge.
47Supply & fixing in Replacement of power capacitor bank of the following capacities of make L&T,ABB,Siemens :- (a) 3 KVAR box type heavy duty capacitor 440V Make:-L&T / HAVELLS/ ABB / SIEMENS
48(b) 5 KVAR box type heavy duty capacitor 440V Make:-L&T / HAVELLS/ ABB / SIEMENS
49(c) 10 KVAR box type heavy duty capacitor 440V Make:-L&T / HAVELLS/ ABB / SIEMENS
50(d) 15 KVAR box type heavy duty capacitor 440V Make:-L&T / HAVELLS/ ABB / SIEMENS
51(e)20 KVAR box type heavy duty capacitor 440V Make:-L&T / HAVELLS/ ABB / SIEMENS
52Supply and fixContactors capacitor duty rating 3 phase 415 V suitable for 3 KVAR Make:-L&T / HAVELLS/ ABB / SIEMENS Complete all as specified and directed by Engineer-In-Charge.
53Supply and fixContactors capacitor duty rating 3 phase 415 V suitable for 5 KVAR Make:-L&T / HAVELLS/ ABB / SIEMENS Complete all as specified and directed by Engineer-In-Charge.
54Supply and fixContactors capacitor duty rating 3 phase 415 V suitable for 10 KVAR Make:-L&T / HAVELLS/ ABB / SIEMENS Complete all as specified and directed by Engineer-In-Charge.
55Supply and fixContactors capacitor duty rating 3 phase 415 V suitable for 15 KVAR Make:-L&T / HAVELLS/ ABB / SIEMENS Complete all as specified and directed by Engineer-In-Charge.
56Supply and fixContactors capacitor duty rating 3 phase 415 V suitable for 20 KVAR Make:-L&T / HAVELLS/ ABB / SIEMENS Complete all as specified and directed by Engineer-In-Charge.
57Supply and fixdisplay/relay unit computerised control of Power Factor Digital type 4 steps 440 V Make:-L&T / HAVELLS/ ABB / SIEMENS Complete all as specified and directed by Engineer-In-Charge.
58Supply and fixdisplay/relay unit computerised control of Power Factor Digital type 8 steps 440 V Make:-L&T / HAVELLS/ ABB / SIEMENS Complete all as specified and directed by Engineer-In-Charge.
59Supply and fixdisplay/relay unit computerised control of Power Factor Digital type 12 steps 440 V Make:-L&T / HAVELLS/ ABB / SIEMENS Complete all as specified and directed by Engineer-In-Charge.
60Supply and fix LED Indicator 20mm dia replaced by old indicator Make:-L&T / HAVELLS/ ABB / SIEMENS, Complete all as specified and directed by Engineer-In-Charge.
61Supply and fix Digital multifunction meter (V, A, F, PF) replaced by old ,Make:-L&T / HAVELLS/ ABB / SIEMENS, Complete all as specified and directed by Engineer-In-Charge.