| Sl. No. | Item Description |
| 1 | Taking down cement plaster on brick or concrete surfaces including raking out joints, hacking for key scrubbing down with water etc all as specified and directed |
| 2 | Dismantling floor hearth or wall tiling including cement mortar bedding (incl backing), incl removing the rubbish out of MOD land complete all as specified and directed. |
| 3 | Dismantling water tanks of capacity exc 500 litres but n.exc 1000 litres complete all as specified and directed. |
| 4 | Dismantling water tanks of capacity exceeding 1000 litres but not exceeding 2000 litres complete all as specified and directed. |
| 5 | Taking up or down steel tubing and connections 20 mm bore of pipe complete all as specified and directed. |
| 6 | Taking up or down steel water tubing and connections of following descriptions :-25mm. |
| 7 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) incl removing the demolished material out of MOD land complete all as specified. |
| 8 | Taking down chowkats or frames with shutters (without taking of shutters from the frames) not exceeding 1.5 Sqmeach complete all as specified and directed. |
| 9 | Taking down Chowkhats or frames exc 1.5 sqm but n.exc 4 sqm with shutters (Without taking off shutters from the frame) |
| 10 | Dismantling of brick tiles or terracing tiles, single layer on roofs complete all as specified and directed. |
| 11 | Demolition of mud phuska in roofs any thickness including plastering and leeping (whether full thickness removed or only a part thereof) complete including removal outside of MoD land complete all as specified and directed. |
| 12 | Demolition of RCC Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work in ground floor stair case (reinforcement cut as required to facilitate demolition) |
| 13 | Demolition of brickwork built in cement mortar complete all as specified and directed |
| 14 | M&L forfollowing :-(i) chipping of spalled and loose concrete and cleaning rust from re-inforcement by sand brushing scrubing down concrete surfaces with wire brushes cleaning with water allowed to dry(ii) Applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bonding coat of a layer of epoxy adhesive on complete exposed surfaces of concrete(iii) Guniting in two layers over steel welded mesh 2 mm dia of wire and total aperture 75 mm, thickness of gunite n.exc 25 mm thick (average thickness) using cement mortar 1 :3 with OPC 43 grade cement mixed with polycrete admixture @ 2 % by wight of cement or as per manufactures instructions using pressure guniting machine(iv) Applying cement plaster in cement mortar 1:4 mixed with WPC @ 0.2 Ltr per bag of cement used over guniting surfaces ofrequired thickness to give an even uniform and smooth finish conforming to proper Geometrics to match with the existing surface as in side and soffits of slabs,chajjas,fins,facias ,parapets ,columns and beams etc complete including necessary scaffolding ,shuttering necessarychased to brick work or RCC members at any height upto six storey buildings including removing of small trees shrubs etc all as specified.(Note: steel welded mesh to be welded with the existing reinforcement.The cost of wire mesh is deemed to be included in the quoted rate complete all as specified and directed. |
| 15 | Providing and fixing semi unitized curtain wall glazing including fabrication,packing,delivery at site and installation of Glass façade/ Vision steam of approved shop drawing,designs and section,supported on semi unitized glazing system at all levels incuding errection using (Middle Mullion 131 mm x 67 mm x 2mm thick) Aluminium section as vertical, (Transom-81mm x 67mm x 2mm thick) Aluminium section as vertical/Horizental with 60 micron powder coating colour as approved by Eng-in-Charge,Double Adhesive tape (6x12),Nut solt(10x120mm long),EPDM Gasket,Structure silicone,weather silicone (Dow Corning),Glass Specification: 6mm blue ST-150 thick clear toughened glass with solar control coating complete all as per manufaturer\"s instructions and all as specified and directed. |
| 16 | M&L for 15mm thick ready mix cement plaster with bulk density 1.4 to 1.70KG per ltr water ration 17 to 19% by weight with compressive str as per IS 4031 part-VI applied as per the manufactore instr incl necesaery cement screed and prepartion of surface to received ready mix plasterup to 4 storey bldg including scaffolding . complete all as specified and directed by engineer-in-charge |
| 17 | M&L for 5mm thick ready mix cement plaster ceiling / chhaja with bulk density 1.4 to 1.70KG per ltr water ration 17 to 19% by weight with compressive str as per IS 4031 part-VI applied as per the manufactore instr incl necesaery cement screed and prepartion of surface to received ready mix plaster up to 4 storey bldg including scaffolding. complete all as specified and directed by engineer-in-charge. |
| 18 | M&L forPreparing of newly plasterd ceiling surfaces and applying two coats of plastic paint of any colour using roller including one coat of primer over one coat of 3mm thickBirla wall care puttycomplete all as approved by manufacturer and colour as approved by Engr-in-Charge.(Make :Weather coat of Berger /Apex ultima of Asian paints) |
| 19 | M&L for preparation of old decoreatedexternal wall / Ceiling surface of existing treatmentby scrapping with TruCare Wall Sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7”/9” to make the surface free from dust, loose paint etc.or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible up to G+ 4 storey bldgcomplete all asspecified and all as directed by Engr- in-charge.Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes.2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+4bldg including scaffolding |
| 20 | M&L for preparation of Old / newly plaster surface of wall / Ceiling surfaceapplyingtwo coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machineincl two coat of primerup to G+4 storey bldg including scaffoldingcomplete all asspecified and all as directed by Engr- in-charge. |
| 21 | Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance> 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner all as specified and directed. |
| 22 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where everrequired) and fitting the same with necessary stainless steel nuts and bolts complete, includingfixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel boltsetc., of required size, on the top of floor or the side of waist slab with suitable arrangement etc complete all as specified and directed. |
| 23 | M & L for Machine cut Kota stone slab flooring 20-25mm thick overover and incl 20mm thick screed in CM 1:6 complete cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including grinding, rubbing and polishing complete all as specified and directed. |
| 24 | Separating, Scrapping & Cleaning of Reinforcement.(Demolition of Cement Concrete measured seprately |
| 25 | Removing demolition material exc. 1.50KmBut N.exc5 Km& Depositing Where Directed at a level N.exc 1.5m above the starting Point |
| 26 | S&F TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, beinding spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete. |
| 27 | M & L for providing RCC (type B1 1:2:4) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like chajjas all as directed and specified. |
| 28 | Formwork to soffits of suspended slabs rough finished such as roof slabs, flor slabs, landings and similar work not exceeding 200 mm thick all as specified and directed |
| 29 | S&F in repair PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls, 75 mm bore complete all as specified and directed. |
| 30 | S&F in repairs PVC (SWR) 75mm bore pipes,single socketed in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. |
| 31 | S&F in repairs 75mm PVC (SWR) floor trap/ nahni, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 32 | S&FPVC(SWR) bends any radius, 75 mm bore oval access door complete all as specified and directed. |
| 33 | S&F PVC(SWR) junction single, (Single T) equal or unequal any radius, 75mm bore complete all as specified and directed. |
| 34 | S&F PVC(SWR) branch piece, double (double Y) 75mm bore complete all as specified and directed. |
| 35 | S&F PVC(SWR) couplers any radius, 75mm bore complete all as specified and directed |
| 36 | S&F PVC(SWR) vent cowl any radius, 75mm bore complete all as specified and directed. |
| 37 | S&F in repairs PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls, 110 mm bore complete all as specified and directed. |
| 38 | S&F PVC (SWR) pipes 110mm bore , single socketed in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. |
| 39 | S&F PVC(SWR) bends any radius, 110 mm bore complete all as specified and directed. |
| 40 | S&F PVC(SWR) junction single, (Single T) equal or unequal any radius, 110mm bore complete all as specified and directed. |
| 41 | S&F PVC(SWR) branch piece, double (double Y) 110mm bore complete all as specified and directed. |
| 42 | S&F in repairs PVC(SWR) vent cowl any radius, 110mm bore complete all as specified and directed |
| 43 | S & F Stack clamps made out of50 mm by 5 mm flat iron and 16 mm dia around iron stays including boltand nuts for securingends of stays to walls or roofs, bore pipe75mm dia pipe complete all as directed. |
| 44 | S & F Stack clamps made out of50 mm by 5 mm flat iron and 16 mm dia around iron stays including boltand nuts for securingends of stays to walls or roofs, bore pipe 100 mm dia pipe complete all as directed. |
| 45 | S&F 500 ltr capacity HDPE water storage tank, cylinderical vertical with closed top, having three layers,with over all thickness as per IS with locking arrangements hoisted and fixed in position complete all as specified and directed in SSR Part-II. |
| 46 | S&F 1000 ltr capacity HDPE water storage tank, cylinderical vertical with closed top, having three layers,with over all thickness as per IS with locking arrangements hoisted and fixed in position complete all as specified and directed in SSR Part-II. |
| 47 | S&F 2000 ltr capacity HDPE water storage tank, cylinderical vertical with closed top, having three layers,with over all thickness as per IS with locking arrangements hoisted and fixed in position complete all as specified and directed in SSR Part-II. |
| 48 | S & F 25mm Nipple suitable for HDPE water tank (Minium weight 20mm - 45 gms) |
| 49 | S&F ball brass valves, high pressure, with polythene float and fly nut, screwed for iron pipe or brass ferrule 25 mm bore complete all as specified and directed. |
| 50 | S & F in repairs Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 25 mm bore complete all as specified and directed. |
| 51 | S & F mild steel flat iron as in hold fast clamps articles conforming to FE 290 Gde 165 complete all as specified and directed |
| 52 | M & L for Stainless steel curtain rod with fixing brackets incl all accessories complte all as specified and directed. |
| 53 | Providing and fixing factory made uPVC any colour casement (Openable) Door made of extruded profilewilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, frame(60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 8mm thick glazing with toughened glass all as specified and directed. (Note: The unit rate quoted by contractor includes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose). |
| 54 | Providing and fixing glass paneling with 3 inch thick wooden to be provided for any type of Partitions as per directions for the existing raw surfaces such as plywood, partical board, MDF,HPL Board,Sunmicca etc directly to be mounted over the surface or over and including SS studs , necessary hardware, fittings, fixtures etc complete as per the directions of Architect. |
| 55 | Providing and fixing factory made uPVC any color Sliding window Two track made of extruded profiles with wall thickness of 2.3mm (+- 0.2mm). Window profile with hollow sectionwith multi chamber, Frame (60mm x 62mm). sash (42mm x 67mm). Sliding Interlock (One vertical length in each shutters) (45.5mm x 28mm). Glazing bead (24.5mmx 16mm) will he mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel frame (30mm x 21.5mm), Sash (30mm x 18mm), profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. Hardware : [Touch Lock of zinc alloyed (white powder coated), steel roller system including 6mm thick glazing with toughened glass, aluminum track on bottom rail for two track sliding frame, wool pine for Sliding sash and interlock and incl cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) |
| 56 | Providing and fixing factory made uPVC sliding window of any colour approved by engr-in-charge, three track made of extruded profiles with wall thickness of 2.3m (±0.2mm). Window profile with hollow section with multi chamber frame (88mm x 52mm),sliding sash (42mm x 67mm), sliding mesh sash (42mm x 57mm), sliding interlock (one vertical length in each shutters) (45.5mm x 28mm) Glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, incl railing of holes for fixing of hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 ±0.2mm thick galvanised steel frame (30mm x 18mm) 02 nos, sliding sash (30mmx18mm), sliding mesh sash (26mm x 10mm), Profile to be insterted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners.Hardware : (touch lock of zinc alloyed (white powder coated), steel roller system, aluminium wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories including anti pigeon spiking arrangement). |
| 57 | S & F solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed. |
| 58 | S&F Factory made solid panel PVC door shutter30 mm thick (style)consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC `C\"channel having a PVCsheet strip of 20 mm width stuck inside with solvant cement for stiles and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert of top rail and bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and raials with suitabale PVC sheet beading, and jointed together with solvant cement, andS&Fin the frame at side as per specification and drawing. |
| 59 | S&F 150mm long aluminium anodised barrel tower bolt of extruded section and fixed to PVC door complete. |
| 60 | S&F 150mm long aluminium anodised handles, extruded aluminium alloy fabricated type and fixed to PVC door complete |
| 61 | S & F butt hinges extruded aluminium alloy with galavanised mild steel hing pinanodised and fixed type 100mm size C21 |
| 62 | Providing and fixing factory made uPVC any colour fixed window made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. makingarrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick, galvanized steel Frame (28mm x21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with 6mm thich toughenedglass (Note: The unit rate quoted by contractor includes cost of glass andall other connected accessories Net opening will be measured for payment purpose.) |
| 63 | M&L for 25mm thick plain cement concrete type B-1, 1:2:4 (20mm graded aggregate) in sub floors complete. |
| 64 | Providing and laying 10mm thk Mirror finish super-premium range, digital and high gloss Vitrified Tiles of approved reputed makes of size 800X1600 x 10mm thk (Min) laid in required pattern on an avg. 25 to 30mm thk. bed of 1:4 cement mortar (1 cement : 4 coarse sand) including neat white cement float, filling joints with neat cement slurry, of appropriate colour, curing and cleaning complete.Tiles shall be free of any variation in colour or texture, and laying plastic sheet & 18mm thk. POP protective cover on flooring and removing when directed.. |
| 65 | Providing and laying 10mm thk super premium range and Anti-skid Matt finish premium range approved Vitrified Tiles for toilets of reputed approved make of size 600 x 1600 x 10mm thk (Min) laid in requiredpattern on an avg. 25 to 30mm thk bed of 1:4 cement mortar (1 cement : 4 coarse sand) in proper line and level including neat white cement float, filling joints with neat cement slurry, of appropriate matchingcolour, curing and cleaning complete.Tiles shall be free of any variation in colour or texture. The cost to include sealer treatment of Aqua mix brand. |
| 66 | M&L for Designer vitrified wall tiles of Size 600 x 1200mm laid in required pattern vertical surface set and jointed in neat10 mm thick heavy duty, chemical resistant adhesive for fixing tileon wall. Tiles shall be free of any variation in colour or texture, and laying plastic sheetcover on wall/flooring and removing when directed. |
| 67 | M&L for complete removal existing treatment and Preparing of old plasterd wall/ Ceilingsurfaces and applying two coats of plastic paint of any colour using roller including one coat of primer over one coat of 3mm thickBirla wall care puttycomplete all as approved by manufacturer and colour as approved by Engr-in-Charge.(Make :Weather coat of Berger /Apex ultima of Asian paints) |
| 68 | Providing and fixingplaster of paris ceiling to flat surface and curved surface including moulding,cove and design approved by Engr-in-Charge overmetal frame work and reinforced with G.I. wire mesh .Metallic grid coforming to IS: 2095: :1982 section 80 x26x30x0.5mm, perimeter channel 20x28x30x0.5mm, intermediate channel 15x45x15x0.9mm, ceiling angle 25x10x0.5mm, connecting clip, soffit cleat necessary rawl plug screws,Including filling the gaps with POP & painting the same with two coat Acryllic Emulsion paint over one coat of primer of approved colour and texture as per instruction of Eng-in-Charge. (Make- sakarni) |
| 69 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorscomplete all as specified and directed by Engr-in-Charge. 25 mm dia. |
| 70 | Cutting chases, pinning in, making good to facings in brick wallswhere required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills sunshades shelves lintels etc and cutting chases for concealed waer tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth complete |
| 71 | S&F CPVC pipe SDR-7.4, 20 mm bore with plain SDR-11 fittings complete to walls and ceilings or laid floors or concealed,( cost for cutting chases in wall/ceiling for concealing tube shall be measured seperately) complete all as specified and directed. |
| 72 | S&F in repairs Vitreous china wash down water closet pan wall mounted complete single unit including double syphonicflusing cistern white, seat cover including connection to drain trap complete. all as specified and directed. Make : (Parryware Model : Verve, white, C0269 closet including soft close seat covers, C0762 cistern set including fittings) or equivalent) complete all as specified |
| 73 | S&F in repairsvitreous china white wash basins, incl waste pipe, brackets, and connecting pipe fixedcomplete all as specified. Make : (Parryware C8411 Venice, white) or equivalent) |
| 74 | S&F in repairs Basin mixer cast copper alloy, chromium plated fixed to15mm dia MS pipe complete (Make parryware T4014A1 or equivalent) |
| 75 | S&F in repairs Wall Mixer with Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flangescomplete (Make Cat No-QQT-7273UPR Jaquar or equivalent) |
| 76 | S&F in repairs 2-Way Bib Cock with Wall Flange fixed to15mm dia MS pipe complete (Make Cat No-QQT-7041 parryware/Jaquar or equivalent) |
| 77 | S&F in repairs brass chromium plated shower rose of size 125 mm with 24\"\" Long arms including fixing to steel pipe. (Make Cat No-OHS-1605 Parryware/ Jaquar or equivalent) |
| 78 | S&F Corner sheet glass shelf with complet fittings complete all as specified and directed by Engr in charge. (Make jaguar ACN-1173 or equivalent) |
| 79 | S&F in repairs Toilet paper holder with coverfixed to walls with chormium plated bracs screws complete. Make : (ParrywareT6514A1) or equivalent) |
| 80 | S&F in repairs Health faucet cast copper alloy chromium plated with flexible chrome hose and wall SS hooks complete. Make : Parryware T9941A1) or equivalent) |
| 81 | S&F soap dispanser fixed to wall complete. (Make Parryware T6706A1 or equivalent) |
| 82 | S&F in repairs angle cock chormium plated fixed to 15 mm dia MS pipe complete (Make parryware G0253A1or equivalent) |
| 83 | S&F in repairs Towel Railfixed to wall with chromium plated braces screws complete (Make Parryware T6501A1 or equivalent) |
| 84 | S&F in repairs 650mm long stainless steel (316 grade)Towelrack fixed to wall with brass screws complee (Make Parryware T6008A1 or equivalent) |
| 85 | S&F 600mm long PVC connection pipe fixed to 15mm dia pipe complete |
| 86 | S&F 450mm long PVC connection pipe fixed to 15 mm dia pipe complete. |
| 87 | S&F 6mm thick looking mirror 900x450mm bevelled edge mirror of selected quality glass, mounted on 10mm thick PVC moulded prelaminated one side sheet and fixed to alaround 50mm wide PVC moulded frame with chromium plated brass screws and cup washers fixed to wall complete. (Make : Parryware C863099 or quivalent) |
| 88 | S&F 100mm PVC (SWR) floor trap/ nahni, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 89 | S&F cast copper alloy chromium plated bottle trap fixed to WHB and wall complete (Make Parryware T3202A1, or jaquar |
| 90 | S&F in repairs Sensor urinal (Jaquar SNR STL 51087 or equivalent) fixed to wall complete. |
| 91 | S&F in repairscurved shaped 8mm thick frosted glass urinal partition of size 900x 450mm (Make Jaguar JSE-CHR-810UC 450X or equivalent)) incl necessary SS clamp and bottom support to fixed on wall and floor complete as specified. |
| 92 | S&F sheet glass shelf assemble consisting of 5.5mm thick sheet glas shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete.(Make Jaguar AKB-35771 or parryware T6009A1 |
| 93 | S&F 350x300mm white vanity column (Make Kerovit Model Theo KB125192 or equivalent) |
| 94 | M&L for Decorative 10mm thick PVC sandwich False ceiling boarding withincl GI framework for seamless ceiling comprising of Gypsteel Ultra Ceiling section 80 x26x30x0.5mm, perimeter channel 20x28x30x0.5mm, intermediate channel 15x45x15x0.9mm, ceiling angle25x10x0.5mm, connecting clip, soffit cleat necessary rawl plug screws, complete all as specified and directed |
| 95 | M&L for 20mm thick Granite (red rubby or as approved ) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like in cement mortar (1:4) incl pointing in white cement (1:2)using marbledust with admixture of pigment to match with shade of granite over and incl 20mm thick screed in CM 1:6complete |
| 96 | Rounding to edges of stone slab one edge, such as steps, cooking platform and other similar situations and rubbing and polishing complete |
| 97 | S & F 18/19 mm thick post forming both side prelaminated water Proof ,anti termite WPC board forkitchen cabinet boxes with shelf, drawer and shutter full size fitted under the kitchen cooking platform and other platform incl fittings etc complete all as specified and directed including provision of fixing arrangement Make- Rajshree or equivalent. |
| 98 | S&F in repairs 6 mm thick one side prelaminated decorative PVC sheet and other side plain in cupboard & like items inclusive of solvent cement & fixing at site complete all as specified and directed.e. Make- Rajshree or equivalent. |
| 99 | S&FModular auto concealed soft closed hinges 35mm 110 degree size complete all as specified and directed. |
| 100 | S&Fstainless steel handle 200mm complete all as specified and directed. |
| 101 | S&Fstainless steel handle 150mm complete all as specified and directed. |
| 102 | S&FPVC tape 18mm wide with adhesive complete all as specified and directed. |
| 103 | S&Fmultipurpose basket (470x535x150)mm stainless steel of grade 304 complete all as specified and directed. |
| 104 | S&Fperforated cutlary (475x485x350)mm stainless steel of grade 304 complete all as specified and directed. |
| 105 | S&F grain trolly with base (450x500x300)mm stainless steel of grade 304 complete all as specified and directed. |
| 106 | S&FThree tier trolley bottle pull out of size 485x530x150mm of stainless steel of grade 304 complete all as specified and directed. |
| 107 | S&Fbottle pull out 150x485x430 mm with two shelf stainless steel of grade 304 complete all as specified and directed. |
| 108 | S&Fcup & soucer basket(470x535x100)mm stainless steel of grade 304 complete all as specified and directed. |
| 109 | S&Fcup & soucer basket(470x535x100)mm stainless steel of grade 304 complete all as specified and directed. |
| 110 | S&Fcylinder trolly stainless steel of grade 304 complete all as specified and directed. |
| 111 | S&Fbin holder stainless steel of grade 304 complete all as specified and directed. |
| 112 | S&Fdetergent holder (254x152x279 mm) stainless steel of grade 304 complete all as specified and directed. |
| 113 | S&Ffor Telescopic drawer channel rollers for shelves of size 350mm long completestainless steel of grade 304 complete all as specified and directed. |
| 114 | S&Ffor Telescopic drawer channel rollers for shelves of size 500mm long completestainless steel of grade 304 complete all as specified and directed. |
| 115 | S&F for wall mounted kitchen platerack of size 900mmx600mmx250mm made out of 1mm thick stainless steel sheet of 304 AISI grade fixed to walls with required size of raw plug and steel screws as per manufacturer instructions. Make - PRAYAG/ BLUESTAR/ CERA/ SAPHHIRE/ BHARATI/ ARCHITA/ JAYNA/ NIRALI. description and pattern shall be as per sample. |
| 116 | S&Fin repairs double bowl stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or lab with plug, washers waste pipe, cast ironn cantilever brackets, connecting union overall sie 915x460mm with two bowl size 410x330x160mm complete. |
| 117 | S & F in repairs brass CP sink mixer with regular swinging spout (wall mounted model) with connecting legs and wall flanges water screwed down for iron pipe15 mm bore and fixed complete all as specified and directed. (MAKE : JAQUAR CQT-23309, Hindware cat no. F-200023 OR EQUIVALENT |
| 118 | M&L for 18mm thick designer WPC Jalli exterior grade of design, shape and colour as approved by Engineer in charge conforming to IS 2380incl necessary fittingfixed to wall or shaft complete |
| 119 | M&L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built , built in cement motar 1:6. complete all as specified and directed. |
| 120 | M&L for Two Component Polymer modified flexible cementitious waterproof (breathable) coating of equivalent flexible and elastic polymer modified, 2 component cementitious coating system having UV resistance applied in 2 coats in the form of slurry at right angles by way of brush at a total consumption of 2 Kg. per Sqmt. over theVertical Brick Wall, Curing Testing etc Completed- Including Gola Vata & Joints Treatment etc.complete as specified and as diected by Engr-in-charge. |
| 121 | M&L for Providing Protective levelling plaster for Horizontal &Vertical Surfaces of average 15-20mm thick in cement mortar (1:4) including mixed with liquid integral waterproofing admixture @ 200 Ml. per bag of cement,finished smooth, curing etc.complete as specified and as diected by Engr-in-charge. |
| 122 | Providing and fixing for dome of size 6.5 meter dia and 3.25 meter height stainless steel grade-S.S 304(JINDAL), vertical tube-150mmx75mmx3.5mm(thick) with police,Horizental tube-40mm x 80mm x 2.5mm thick (with police), Base plate-150mm x 150mm x 8mm thick with chemical fastener, Top sheet-SS Sheet round 600 mm X 1.5MM thick incldismentaling of old dome and fixing of 13.52mm thick laminated glass with Glass wooden frame incl all necessary fittings complete as per manufaturer;s instructions and all as specified and as directed by Engr-in -charge. |
| 123 | SPECIAL ITEMS OF WORK:- Providing and fixing approved Mirror polished approved premium range Galaxy Black Granite slab flooring including with white marble border(Sparkling Jet Black / Raw Silk / Black Pearl or equivalent approved) for Corridors flooring, inlay & design works, staircase,skirtin incl backing, treads & risers, landings, bunds,g in 18mm to 20mm thk granite and size upto 8\" x 6\" over and including avg 25 to 30mm thk. 1:4 (1 cement : 4 coarse sand) bedding in proper line & level including the joints to be finished flushed in matching colour cement, curing, washing, cleaning and rate to include for chipping and levelling existing floor and laying plastic sheet & 18mm thk. POP protective cover on flooring and removing when directed as req., including moulding and 1/8\" grooves complete and as directed by Engr-in-Charge. |
| 124 | Providing and laying in position approved 18mm to 20mm thk high end Onyx Italian Marble such as Tiger onxy stone or equivalent approved for bar countertop work in required size and pattern as directed including base mortar with 1:4 white cement mortar (1 cement : 4 coarse sand), pointing, joints finished in line and level and flushed in matching colour cement, curing, rubbing, machine mirror grade polishing, washing, cleaning and sealer for anti-stain of Aqua mix brand etc complete as per the directions of engr-in- charge. |
| 125 | S&F 8mm thick toughenedglass ( CG Crest embossed), of required size, making holes,incl all fittings and fixed to SS railing with necessary patchs in positioncomplete. |
| 126 | S&F in reapirs 12 mm thick frosted toughned Glass doors with necessary stainless steel fixing patches and lock patches etc fixed complete . |
| 127 | S&F 900mm long Stainless steel AISI 316 Door handles fixed to toughned glass door complete (Make Kich PHN 32 x 10mm) |
| 128 | S&F Double action floor door spring hydraulically regulated made up of min 1.25mm thick aluminium alloy sheet foundation box, main body with stainles steel cover governing pivot made of brass, heavy duty wt capacity upto 100kg fixed to door complete all as specified and directed. Make Kich Cat No FS112S or Godrej or equivalent. |
| 129 | ProvidingACP CLADDING- Aluminium Composite Panels 4mm thick of any colour approved by eng-in-charge, Make: Alsrong,Aludecore,Alstone,Viva,(or equivalent) on vertical and horizontal surface of Architectural features and covering of pressure plates as per elevations approved by the architect on exteriors of building, ACP panel consisting of two aluminium cover sheets and a plastic or high mineral filled core, both side stove lacquered finish and top side of approved PVDF colour /shade including cutting with jig saw, bend to shape, making grooves, making holes by drills, natural aluminium tube base framing fixed with cleats, self tapping screwing, welding, clamping, glueing,sealing the joints with approved sealant complete as per pattern shown in drawingsat all levels including cost of mild steel pipe scaffolding erecting / dismantling & removing of film |
| 130 | M&L for Designer vitrified wall tiles of Size 600 x 1200mm laid in required pattern vertical surface with grooves wherever required as per engr-in-charge ,set and jointed in neat10 mm thick heavy duty, chemical resistant adhesive for fixing tileon external wall ofbuilding. Tiles shall be free of any variation in colour or texture, and laying plastic sheetcover on wall and removing when directed.Note .rate quoted by contractor up to G+4 bldg including steelscaffolding |
| 131 | Internal electrification:- Taking down copper/aluminium point wiring (light,fan, socket or power) including fixture and fittings complete etc removing the materials for taking credit and making good the disturbed surface of wall/floor etc. |
| 132 | Taking down carefully submain wiring with aluminum conductor cable 4/6/10 Sqmm in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc. |
| 133 | Taking down carefully DB of any size complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc. |
| 134 | Taking down Existing Electric meter and depositing to MES Store complete all as directed |
| 135 | Material and labour of point wiring for the followings with 1.5 Sqmm single core, PVC FRLS insulated unsheathed, multistranded copper conductor drawn through and includingPVC conduit mediumgrade including necessary accessories like bends, tees, PVC junction, square elbow etc fixed on wall/ceiling with 1.5 Sqmm PVC FRLS insulated unsheathed stranded copper conductor cable as earth conitinuity (green in colour) connected to common earth dolly including modular type pressed steel terminal boxes (whose thickness not less than 3 mm) of suitable sizes withmodular PVC white frame where modular switch socket to be fixed complete all as specified and directed :- |
| 136 | (a)One light point controlled by one,one way switch. |
| 137 | (b)One fan point controlled by one,one way switch. |
| 138 | (b)One Exhaust fan point controlled by one,one way switch. |
| 139 | (c)One 3 Pin 5 Amps socket out let point onSameboard. |
| 140 | (d)One 3 Pin 5 Amps socket out let point onindependentboard. |
| 141 | (e)One bell/buzzer point controlled by one push button on the same board with other switches or independentboard |
| 142 | All as per item No 135 here-in-before but using 2.5 sqmm PVC FRLS insulated copper condutor wire for connecting 15 Amps socket on independent board. |
| 143 | Supply and fixingof switch Modular type 240 Volts 6 Amps, SP, one way complete all as specifed/directed. |
| 144 | Supply and fixing modular socket outlet multipurpose 2/3 Pin,6 Amps, 240 volts(with 2 pin 5 Amps outlet also) flush type (shuttered) complete all as specified/ directed. |
| 145 | Supply and fixing of Modular socket 2/3 pin, 16 Amps and (with 2/3 pin 6 Amps outlet also) complete all as specified/directed. |
| 146 | Supply and fixing ofModular Switch 1 way 16A, 1 module complete all as specified. |
| 147 | Supply and fixingofModular Bell push 6A 1 module complete all as specified and directed. |
| 148 | Supply and fixingofofBell Multi Music type 230 volts single phasecomplete all as specified and directed. |
| 149 | Supply and fixingof ceiling rose surface PVC/Polycarbonate, 65x50 mm two to three terminals complete all as specified/directed. |
| 150 | Supply and fixing25 A MCB Protected Socket PVC Plastic Base Model of Make : Havells ,Cat No.DBOXx or equivalent in L& T /Legrand completed all as dircted |
| 151 | Supply and fix LED batten luminaire surface mounted ,4 feet system wattage of not less than 18 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 4000 to 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 120 Lumens/watt, filcker free (Ripple less than 5%) andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed with 5 years of replacement warranty on fittings completeallas specified and directed. Make :- Philips/Orient/Jaguar |
| 152 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size,complete all as specified and directed. Make :- Philips/Orient/Jaguar |
| 153 | Supply and fixing Wall mounted light 2 x4 watt with frosted glass with chrome finish wall lampincluding connecting up with three core flexible copper conductor cable of suitable size complete all as directed Cat No. JNL-CHR-MB160275212A of Jaquar or eq |
| 154 | Supply and fixing round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. Make :- Philips/Orient/Jaguar |
| 155 | Supply and fixing round shape 12 watt 220 volts AC Suitable for false ceilingincluding connecting up with three core flexible copper conductor cable of suitable size complete all as directed. Make :- Philips/Orient/Jaguar |
| 156 | Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for surface/recess mountedincluding connecting up with three core flexible copper conductor cable of suitable size complete. Make :- Philips/Orient/Jaguar |
| 157 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. Make :- Havells/Polycab/ Philips |
| 158 | Supply and fixing Study lamp 8 Watt, sleek and modern design with a solid metal base and frame finished in a gorgeous matte gold, this piece comes with in-built LED within a metal shade in a wooden finish. Providing a bright white light directly beneath itself, this lamp is a beautiful piece built for work or study deskscomplete fixing on wall / table all as directed.Make :- Havells/ Philips/ Jaguar |
| 159 | Supply and fixing LED Bldg Security light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make :- Havells/ Philips/ Jaguar |
| 160 | S&F Bed side light fitting 3Watt including connecting up with suitable size twin core twisted flexbile copper conductor cable complete all as specified and directed by Engineer-in-charge. Confirming toJaquar model no- WBR-ABR-BELLFAB255 Make : Jaquar or eq inHavells/Bajaj/phillips/crompton |
| 161 | Supply and fixing of Sub main wiring with two runs of single core 4 Sqmm (nominal area)PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 Volts grade drawn through and including PVC concealed cunduct of adequate sizewith all necessary fittings and accessories and one run of PVC insulated and unsheathed single core cable with copper conductor of size 4 Sqmm as earth wire (green in colour) run through concealed cunduct and connected to common earth dolly, including taking out the old one two run of cable one run of concealed cunductand one run of earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed. |
| 162 | Supply and fixingof Sub main wiring with two runs of single core 10 Sqmm (nominal area)PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 Volts grade drawn through and including PVC concealed cunduct of adequate size and surface with all necessary fittings and accessories and one run of PVC insulated and unsheathed single core cable with copper conductor of size 10 Sqmm as earth wire (green in colour) run through concealed cunduct and connected to common earth dolly, including taking out the old one two run of cable one run of concealed cunduct and one run of earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed. |
| 163 | S & Fvertical distribution board, double door,4 way, VTPNclass IP-54, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 200 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet including connection of cable with proper size of lugs complete all as specified and as directed. |
| 164 | S & F Double doorSheet metal enclosures factory made DBs 12 way ,240 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed |
| 165 | S&F MCBs of the under mentioned type and rating and fixing in DBs (DBs measured and paid for separately) (Note :- Make of the MCB should be the same as that of DB) for the following :- (a) MCB Single Poleof 240 volts 5-32 Amps,10 KA Capacity, \"B\" series |
| 166 | (b) MCB Double Pole 240 volts, 32 -63 Amps,10 KA Capacity, \"C\" series |
| 167 | S&F of MCCB thermal magnetic electric release, fixed type, 4 pole, 63 Amps, 415 Volts with repeturing capacity 16 KA. |
| 168 | S & F RCBO assembled for AC applications upto 63 A ,100 mA ,ISI marked as per IS 12640-2 Integrated label holder Ergonomic design ,Color coded On/Off indication on dolly ,Compatible with signal and control Auxiliaries Front face indication for earth leakage fault IP 20 protected terminals35 sq mm terminals Sliding shutters |
| 169 | Taking down Split AC of any capacity from existing position along with pvc cables,copper piping,insulation materials, out door units and refixing and connecting the same inafter servicing,gas top up, drilling on brick wall,including necessary AC outdoor fixing stand from OEM with nuts and bolts complete as required and as directed by engr-in-charge |
| 170 | Taking down oldCeiling fan, sealing cable end, dismantling blades and and removing materials to MES store for keeping in safe custody for further reuse in maintenance work |
| 171 | Taking down oldExhaust fan, sealing cable end, dismantling blades and and removing materials to MES store for keeping in safe custody for further reuse in maintenance work |
| 172 | Taking down carefully Geyser (water Heater) 25 Ltr Capacity complete disconnection of water and electric connection and drain out of water from geyser and empty geyser deposited to MES store for keeping in safe custody for further reuse in maintenance work |
| 173 | Supply and Installation of RF based Smart Single Phase Meter with the following specifications:• AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry.• Meter Should support sending thethe following data to the software : 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand• Meter should have connect / disconnect functionality operable from prepaid billing software• The meter should support open communication protocol DLMSwith the softwareNote: (a It would be possible to run the meter in both prepaid and postpaid mode(b) The meters would carry 5 year warranty. |
| 174 | Supply and Installation of IP-67 protection Data Concentrator Units (DCU) compatible for remote Automatic Metering Infrastructure (AMI) solution and capable of communicating with the smart energy Meter in the corresponding frequency band and with the data server through GPRS/Ethernet. It would have internal memory to store data of at least 200 modules. It would have inbuilt battery back-up. It would have IP-67 protection. It would support auto discovery of the meters and self healing mechanism for the breaks in the RF network. |
| 175 | Supply and Installation of single phase meter (Dummy meter in case of poor/No signal) as repeaters. |
| 176 | Supply and Configuration of the Web based Software with following modules:(i) Meter Data Management ModuleThe meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system.The meter data management system would capture and provide the following data:(a) 30 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency(b) Monthly billing survey data for cum energy and max demand(ii) Postpaid /Prepaid Billing ModuleThe billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required.(iii) Occupation and Vacation ModuleThe system would support occupation / vacation and billing reports.the software would be collecting data from DCU. The software would provide access to staff as well as the occupant for the data.(iv) Web site: There would be a dedicated website for the AGE and BSO team to view all the data and information. The designated users in MES would have the admin access to the application. The MES staff would also have the access of the key information on an android mobiles app (for admin use).(v) Customer PortalThe system would include a customer portal for the resident /occupant to log in and view their own energy / billing data. There would be android and iOS mobile apps for the user to monitor its own data and balance on regular basis. |
| 177 | (vi) Energy Accounting ModuleThe system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available.(vii) Communication ModuleThe system would provide communication of energy data and bills via print, email and sms methods. (viii) Meter Master DataThe system would support meter master data repository. The system would support meter replacement process.(ix) Excel ExportThe system would support export of metering and billing data in excel format. (x)Customer Care Module - the software would include a customer care module where the user would be log in any complaints. The service provider would monitor the complaints and carry out the necessary activities for the complaints resolution.(xi) Meter Installation Module - The software would include an app based meter installation module where the meter installation or changes can be captured on the app itself and the readings may be demonstrated to the user if required on the app itself.(xii) Activities Communication - The software support communication of the various activities such as occupation, vacation, meter change. personal detail change etc. with the user as well as the department on email.Note:- (a) The software would be hosted either on GCC Server or on MES Server. In case the software is hosted on GCC Server, it would be transferred to MESserver whenever the same is made available.(b) The software would contain two year defect liability including all operating expenses such as GPRS charges, hosting charges etc.(c) GE Bank account and one payment gateway would be provided by MES. The payment gateway would be integrated with the software. |
| 178 | S & F Transparent polycarbonatebox for fixing meter of size 250 x 200 x 105 mm including sutable hinges and arrangement for sealing the box complete all as directed. |
| 179 | M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to and including GIwire 4mm dia as earth lead up to 7.5 mtr length by means of bolts, nuts check muts and washers etc. of galvanised iron or steel all as shown in electrical plate No. 3 including provn of GI protectionpipe light grade of 32mm bore upto 7.5m length and connected earth strip to earthing test point all as shown in electrical plate No. 3 of SSR Part - I 2020 and as specified or indicatedand testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (rein forced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 20mm bore medium grade, wire mesh and lugs test point etc. |
| 180 | S&L GI wire as earth lead 4 mm dia (8 SWG) to connect the earth lead as extra as per site requirement. |
| 181 | Supply and fixingof Sub main wiring with fourruns of single core 10 Sqmm (nominal area)PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 Volts grade drawn through and including PVC concealed cunduct of adequate size and surface with all necessary fittings and accessories and one run of PVC insulated and unsheathed single core cable with copper conductor of size 10 Sqmm as earth wire (green in colour) run through concealed cunduct and connected to common earth dolly with necessary thimbels and lugs as required at site |
| 182 | M & L for rigid non-metallic PVC concealed conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., Supplied & fixed External dia in 20 mm, complete all as specified and as directed by the Engineer-in-Charge |
| 183 | M & L for rigid non-metallic PVC concealed conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., Supplied & fixed External dia in 25 mm, complete all as specified and as directed by the Engineer-in-Charge |
| 184 | M & L for junction boxes (1 to 4 way), External dia in 20 mm complete all as specified and as directed by the Engineer-in-Charge |
| 185 | M & L for junction boxes (1 to 4 way) external dia in 25 mm complete all as specified and as directed by the Engineer-in-Charge |
| 186 | Supply and fix TV cable co axial, completeas specified and directed. |
| 187 | Supply and fix TV sockets any type, completeas specified and directed. |
| 188 | Supply and fix Tele cable one pair , completeas specified and directed. |
| 189 | Supply and fix Tele sockets any type complete all as specified and directed. |
| 190 | S & F water heater storage type (Geyser) vertical type with suitable size of fastner and including provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tankmaterial of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure completeall as specified of capacity 25 ltr having heating element 2 KW and not less than 5 star rating with minimum two year warranty on product, minimum 3 years warranty on heating element and minimum 7 years warranty on inner tank. |
| 191 | Supply and fixing ceiling fans complete with blade, down rods,and accessories , minimum air delievery not less than 220 CFM,rated speed not less than 350 RPM, 230 V, 1200 mm sweep, with service value not less than 6.85 BEE,5 star rated voltage range 140 - 280 volts power factor > 0.9 and THD <10 %with brushess direct current motor (BLDC) along with step type two module electronic fan regulatorall as specified and directed by Engr in Charge. Note : Down rods length should be as per site requirement. |
| 192 | Supply and fixing Ventilating Fan250 mm sweep, 900 RPM, made up of strudy engineering plastic body,single phase 230 volts AC 50 Hzand connecting up complete including louver shutter and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. |
| 193 | Supply and fixing LED Strip Rope Light,Water Proof,Ceiling Light,Decorative led Light with Adapter complete all as directed |
| 194 | External Electrification:- Taking down u/s LT Cable of Size 150 Sqmm 3.5 Core complete all as specified and directed |
| 195 | Taking down u/s LT Panel complete all as specified and directed |
| 196 | Supply, laying, jointing, testing and commissioning LT underground cables,of size 150 Sqmm 3.5 Core, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-7098 (marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed. Make : Havells/Polycab/KEI |
| 197 | M & L HDPE Pipes PN 10 fixed complete to walls, ceilings or in floors etc for passing of U/G cable through road/hard standing/pole/wall/floor etc. |
| 198 | Supply, installation, testing and commissioningof factory made and testedincluding CPRI approved LT panelin door type , plateform mounted suitable for 415V, 3 phase 4 wire 50, Hz AC supply system having bus bar chamber with insulated Aluminium bus bar, 500 Amp rating installed on porcelain insulator. The panel shall be dust and varmin proof IP 65 class protection and made out of 2.00 mm CRCA MS sheet and 40x40x6mm thick angle iron base frame work, powder coated finish over one coat of red oxide primer out side and two coat of red oxide primer in side, front opening type with aprons for cable entry, with double door shutter and locking arrangement, internal wiring with PVC insulated stranded copper conductor FRLS cable IS 694 marked 1100 volts grade but seathed of adequate size but not less than 4 Sq mm the scope of work includes the following Incoming:- (a) MCCB 4 pole 415 volt 200 Amps 36 KA breaking Cap. With adjustable thermal and overload setting -01 nos (b) Digital Voltmeter & Ammeter with RS 485 Port (c) Phase indicator lamp LED typeRYB-01 set ( 01 set ). Outgoing:- (a) MCCB 4 pole415 volts 63 Amps with breaking capacity 16 KA- 06 Nos (5+1Spare) (b) Digital Voltmeter & Ammeter with RS 485 Port (c) PCC for foundation of panel. Note : Cable glands should be provided for all incoming /outgoing connections. |
| 199 | Supply, installation, testing and commissioningof factory made and testedincluding CPRI approved LT panelin door type , plateform mounted suitable for 415V, 3 phase 4 wire 50, Hz AC supply system having bus bar chamber with insulated Aluminium bus bar, 500 Amp rating installed on porcelain insulator. The panel shall be dust and varmin proof IP 65 class protection and made out of 2.00 mm CRCA MS sheet and 40x40x6mm thick angle iron base frame work, powder coated finish over one coat of red oxide primer out side and two coat of red oxide primer in side, front opening type with aprons for cable entry, with double door shutter and locking arrangement, internal wiring with PVC insulated stranded copper conductor FRLS cable IS 694 marked 1100 volts grade but seathed of adequate size but not less than 4 Sq mm the scope of work includes the following Incoming:- (a) MCCB 4 pole 415 volt 200 Amps 36 KA breaking Cap. With adjustable thermal and overload setting -01 nos (b) Digital Voltmeter & Ammeter with RS 485 Port (c) Phase indicator lamp LED typeRYB-01 set ( 01 set ). Outgoing:- (a) MCCB 4 pole415 volts 63 Amps with breaking capacity 16 KA- 06 Nos (5+1Spare) (b) Digital Voltmeter & Ammeter with RS 485 Port (c) MCB SPN ,240 volts32 Amp breaking capacity 10 KA- 01Nos(d) PCC for foundation of panel. Note : Cable glands should be provided for all incoming /outgoing connections. |
| 200 | Supply and Installation of RF based Smart Three Phase CT opertated Meter with the following specifications:• AC Three Phasefour Wire, Tamper Proof, Static Meter of Class 1.0, 415 V, 50 Hz, 5 A-10 A conforming to IS-16444 and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry.• Meter Should support sending thethe following data to the software : 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand• Meter should have connect / disconnect functionality operable from prepaid billing software• The meter should support open communication protocol DLMSwith the software |
| 201 | Material and labour for earthing with steel earth plate electrode of size 600x600x6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as eathing lead by means of nuts, bolts, and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate. GI medium grade pipe 40mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4 kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of carcoal dust and salt layers all around the earth plate, excavation, earth work in any type of soil, removal of excavated soil and returing filling in all as required at site complete all as specified in plate No 3 of SSR Pt-I and all as specified or indicated including testing on completion.Note :-Rates inclusive of necessary excavation in any type of soil, earth work,PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 Mtr long for connecting to test point etc. All as requied at site for complete earthing. |
| 202 | Supply and install GI Strip 32mm x 6 mm buried in ground/Wall, complete all as specified and directed. |
| 203 | Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr in depth in loose/soft soil and getting out levelling the bottom surface to required gradient complete all as specified for laying of water supply mains all as specified and as directed. |
| 204 | Returning filling in, including spreading , leveling watering and well ramming in layers not exceeding 25cm thick complete all as specified and Directed . |
| 205 | Removal of surplus excavated soil to a distance not exceeding 50mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed. |
| 206 | M & L for good quality dry sand cushinoning to underground electriccableon layer of 8 cm thick before laying the cable and second layer of 15 cm thickafter laying the cable all as specified in clause 19.75 of MES Schedule Pt-I (2009) thickness shall be measured and paid complete all as specified and as directed. |
| 207 | Supplying and laying reinforced precast concrete cable cover class LV, Type I flat, size 250 mm x 150mm x 40mm all as per specified and directed. |
| 208 | EXTERNAL WATER SUPPLY:- Taking down GI pipe 40/50mm dia including complete fixture and fittings etc removing the materials for taking credit and making good thedisturbed surface of wall/floors/trenches etc or removal to store. |
| 209 | Supplying and laying of CPVC pipes of SDR 11 & plain CPVC SDR 11 fittings in trenches complete all as specified of sizeouter dia 50mm. |
| 210 | Supplying and laying of CPVC pipes of SDR 11 & plain CPVC SDR 11 fittings in trenches complete all as specified of sizeouter dia 40mm. |
| 211 | Supply & Fix PP-R Gate vlaves (brass insert) as per requirement of the site of 50 mm outer dia, complete all as specified and directed. |
| 212 | Supply & Fix PP-R Gate vlaves (brass insert) as per requirement of the site of 40 mm outer dia, complete all as specified and directed. |
| 213 | Supply and fix brass elbow of CPVC pipe of size 50mm dia, complete all as specified and directed. |
| 214 | Supply and fix brass elbow of CPVC pipe of size 40mm dia, complete all as specified and directed. |
| 215 | Supply and fix ball valve of CPVC pipe of size 50mm dia, complete all as specified and directed. |
| 216 | Supply and fix ball valve of CPVC pipe of size 40mm dia, complete all as specified and directed. |