}

Tender For Annual Maintenance, Water Proofing Treatment On Terrace And Other Civil Repair Works At Te Building Compound, Ismailkhanpet, Sangareddy Under Medak Ba- Recall, sangareddy-Telangana

Bharat Sanchar Nigam Limited-BSNL has published Tender For Annual Maintenance, Water Proofing Treatment On Terrace And Other Civil Repair Works At Te Building Compound, Ismailkhanpet, Sangareddy Under Medak Ba- Recall. Submission Date for this Tender is 08-11-2023. Water Proofing Work Tenders in sangareddy Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

40455372
Tender For Annual Maintenance, Water Proofing Treatment On Terrace And Other Civil Repair Works At Te Building Compound, Ismailkhanpet, Sangareddy Under Medak Ba- Recall
Open Tender
Indian
Telangana
sangareddy
08-11-2023

Tender Details

Annual Maintenance, Water Proofing Treatment On Terrace And Other Civil Repair Works At Te Building Compound, Ismailkhanpet, Sangareddy Under Medak Ba- Recall

Key Value

Document Fees
INR 590 /-
EMD
INR 4880.0 /-
Tender Value
INR 2.43 Lakhs /-

BOQ Items

Name of Work: : Annual maintenece, Water proofing treatment onterrace andother civil repair works at TE Building compound, Ismailkhanpet, Sangareddy under Medak BA (Recall)
Sl. No. Item Description
1Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.
2Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing :
31:2:4 (1 Cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 10 mm nominal size derived from natural sources)
4Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.
5Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
6Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc.
7Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
840 mm thick with 20 mm nominal size stone aggregate
9Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
10Neat cement punning
11Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
12Water thinnable cement primer.
13Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
14Two coats.
15Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
16Finishing walls with Acrylic Smooth exterior paint of required shade :
17Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface).
18Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
19a)Two or more coats on old/new work
20Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge.
21With cement mortar 1:4 (1 cement : 4 fine sand).
22Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge.
23Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge
2450 mm average thickness
2525 mm average thickness
26Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.
27Bars upto 12 mm diameter
28Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.
29SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
30Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
3130 mm thick
32Carting out of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all loads including bringing the waste material manually by head load from all floors.
33Removing glass panes from windows and replacing them with new glass panes with putty and nails wherever necessary : float glass panes of thickness 4mm
34a) for windows in ground floor and /or for windows which can be accessed from inside of the room / bolcony with ladder arrangement wherever necssary.
35Supplying and spreading of stone aggregate of size 10mm in 50mm thick and below for approach path way including levelling, watering , consolidation and finishing etc as directed by Engineer-In charge
36Supplying and spreading ofCrusher stone sand in 50mm thickfor approach path way including levelling, watering , consolidation and finishing etc as directed by Engineer-In charge
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail