| 1 | Drilling under road / path to cross the pipeline upto 10` |
| 2 | Supply, Installation, Testing and Commissioning of HydrantAssembly complete 4` |
| 3 | Planning, Design, Supply and Installation of 12W LED Street lighting of 75W Solar Panel, 12.8 V, 30 Ah, Lithium Ferrophosphate Battery including Pole of 5 m above ground level. |
| 4 | Supplying, erection, testing and commissioning of Horizontal motor pumping set for clear water having head 60. 00 m as per the indicated requirements of discharge in LPM and power capacity in BHP Make: KSB, CRI, Kirlosker, Crompton Greeve, Lubi) : 100 BHP of 5700 LPM Discharge |
| 5 | Laying of 450mm HDPE Pipe by HDD method including, lowering, aligning, fixing in position and jointing at all level/depth for Approx 50 mtr. |
| 6 | Supply Installation testing commissioning of Solar Photovoltaic Stand alone Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength. Including lightning and surge voltage protection. fixing of array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required, built in metering system to moniter plant performance (Amp-meter, Volt-meter, Frequency meter, Energy meter, Watt-meter and other instrument/equipment as required) Note:- PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards Mono Crystalline Silicon Solar Cell Modules IEC 61215/IS 14286. In addition, the modules must conform to IEC 61730 Part-I- requirements for construction and Part-2 requirements for testing, for safety qualification or equivalent IS and be mounted on fixed aluminium/GI structure of adequate strength and design as per IEC/IS specification. including field based electroluminescence(EL) study be performed after receiving the module at site after installation Module mounting structure(MMS) design and drawing shall be duly vetted from government institute including third party inspection actual parameter/capacity will be finalised after approval of design and drawing. per KW |
| 7 | NS item S/E of Fire extingusher ISI marked CO2 type of 4.5 kg capacity as per IS 7285 duly erected/hangs on wall with hooks i/c including the cost of hooks, screws etc. with all labour and material required to complete the job |
| 8 | NS item S/E of Fire extingusher ISI marked ABC type of 2 kg capacity as per IS 7285 duly erected/hangs on wall with hooks i/c including the cost of hooks, screws etc. with all labour and material required to complete the job |
| 9 | Fire fighting arrangements Including commissioning, testing, supplying and laying of pipeline for fire fighting, including all accessories, for pump house at STP as per the site recruitment confirming to relevant IS code and as directed by Engineer-in-Charge, Complete in all respect. (Design Must be approved before commence of work from Engineer-in-charge). |
| 10 | Fire fighting arrangements Including commissioning, testing, supplying and laying of pipeline for fire fighting, including all accessories, for pump house at Balancing reservoir as per the site recruitment confirming to relevant IS code and as directed by Engineer-in-Charge, Complete in all respect. (Design Must be approved before commence of work from Engineer-in-charge). |
| 11 | 3KW SOLAR OFFGRID SYSTEM WITH ALL ACCESSORIES PANELS : 335W QUANTITY :15NOS BATTERY :8 NOS INVERTER : 1PC(3KW)(AS PER AVAILABLITITY) DC WIRE : 4MM DC BOX : 1PC AC WIRE : 6mm AS PER REQUIREMENT ACCESSORIES : WITH STRUCTURE,DC WIRE, DC BOX, EARTHING,AC WIRE WITH INSTALLATION. |
| 12 | Planning, Design, Supply and Installation of 60W LED Street lighting with Solar Panel, 12.8 V, 30 Ah, Lithium Ferrophosphate Battery including Pole of 5 m WITH DIA 65 MM above ground level. |
| 13 | Planning, Design, Supply and Installation of 30W LED Street lighting with Solar Panel, 12.8 V, 30 Ah, Lithium Ferrophosphate Battery including Pole of 5 m WITH DIA 65 MM above ground level. |
| 14 | PLC panel and Scada for Automation system for various valves complete in all respect as per relevant IS code and as per direction by Engineer-in-chief. (Design Must be approved before commencing of work from Engineer-in-charge). |
| 15 | Quality Sensor/System Analyzer (PH, TSS, BOD, COD and all necessary parameters as per Govt. Norms) for Automation system for various valves complete in all respect as per relevant IS code and as per direction by Engineer-in -chief. |
| 16 | Flow Meter for measuring the flow at inlet for Automation system of Dia 300 mm complete in all respect as per relevant IS code and as per direction by Engineer-in-chief. |
| 17 | Ultrasonic level transmitter for Automation system for various valves complete in all respect as per relevant IS code and as per direction by Engineer-in-chief |
| 18 | Polycab cable 3.5 core 120 sq.mm for Automation system for various valves complete in all respect as per relevant IS code and as per direction by Engineer-in-chief |
| 19 | Motorized actuator 630 mm Automation system for various valves complete in all respect as per relevant IS code and as per direction by Engineer-in-chief |
| 20 | Motorized actuator 450 mm Automation system for various valves complete in all respect as per relevant IS code and as per direction by Engineer-in-chief |
| 21 | Motorized actuator 315 mm Automation system for various valves complete in all respect as per relevant IS code and as per direction by Engineer-in-chief |
| 22 | Motorized actuator 300 mm Automation system for various valves complete in all respect as per relevant IS code and as per direction by Engineer-in-chief |
| 23 | Motorized actuator 250 mm Automation system for various valves complete in all respect as per relevant IS code and as per direction by Engineer-in-chief |
| 24 | Providing and fixing of three phase 50Hz 13% rated motor. frequency 415V± 3% rated motor voltage, with constant motor flux control, (Submersible motors shall conform to all the requirements of IS 9283) Solar A.C. Agricultural Pumps alongwith Universal Solar Pump Controller (USPC) all external part of motor used in open well submersible pump having casing of Alloy steel confirming to IS 3444 Including all PVC insulated polymer sheathed 3 core flat type cabling in conduit, required from solar plant to solar pump through control room required to connect, including cost of and as per IS code 14220-2018 including third party inspection Average discharge 13 LPS/Head 52 meter / minimum / minimum outpurating of 15 KW. Dualy installed on the suitable foundation Actual pump set`s parameters will be finalized after approval of design and drawing. Solar Pumping Sets should be of the make: KSB/Shakti Kirloskar CRV/Lubi/ Crompton/ WPIL, (NS Item) @ Rs 11002.53/- per HP Quantities are total sum of various pumps capacity in HP may varry as per design requirement for site., Rate Approved in the TAC,MICADA haryana meeting dated 09.02.2022 @ ((174708 1.12/20) plus (163063 1.12/15) plus (123310*1.12/12 5))/3 (12.5 HP-5, 15 HP-9, 20 HP-22, 22 HP-13, 30 HP-22, 1HP- 6) |
| 25 | Restoration of metaled , un-metaled road, channel, and drains from stp to reservoir in village . |
| 26 | Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade and PN- 4 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment. 110 mm Outside Dia |
| 27 | Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade and PN- 4 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment.140 mm Outside Dia |
| 28 | Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade and PN- 4 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment. 160 mm Outside Dia |
| 29 | Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade and PN- 4 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment. 180 mm Outside Dia |
| 30 | Maintenance i.e. OandM including 1.Desludging of Balancing Reservoir/Sump Well, 2.Supply of Skilled, Unskilled Manpower, 3. Periodically replacement of various consumable items for smooth running of project. |