Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | WIRING |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 3 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessedmedium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 4 | Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point (without independednt switch etc) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 6 | 2X1.5sq.mm + 1X 1.5 sq. mm earth wire |
| 7 | 2X 2.5 sq.mm + 1 X 2.5 sq. mm earth wire |
| 8 | 2X4sq.mm+ 1X4 sq. mm earth wire |
| 9 | Supplying and drawing following pair 0.6 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair |
| 10 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required. |
| 11 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 12 | 5/6 A switch |
| 13 | 15/16 A switch |
| 14 | 3 pin 5/6 A socket outlet |
| 15 | 6 pin 15/16 A socket outlet |
| 16 | Bell push |
| 17 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 18 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 19 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm) |
| 20 | 6 Module (200mmX75mm) |
| 21 | Supplying and fixing call bell/ buzzer suitable for single phase, 230V, complete as required. |
| 22 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 23 | MCCB, MCB & DB’S |
| 24 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) 12 way , Double door |
| 25 | 16 way, Double door |
| 26 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door |
| 27 | 6 way (4 + 18), Double door |
| 28 | 8 way (4 + 24), Double door |
| 29 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door |
| 30 | 8 way (4 + 24), Double door |
| 31 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required.Single pole |
| 32 | Double pole |
| 33 | Triple pole |
| 34 | Triple pole and neutral |
| 35 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 36 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A |
| 37 | 63A |
| 38 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25A |
| 39 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A |
| 40 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 41 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 42 | CABLE TRAYS |
| 43 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 44 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 45 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 46 | EARTHING |
| 47 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 48 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 49 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 50 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & sprina washer spaced at 50mm) |
| 51 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 52 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 53 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 54 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 55 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. |
| 56 | MV CABLE LAYING |
| 57 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm |
| 58 | Above 95 sq. mm and upto 185 sq. mm |
| 59 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 60 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 61 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 62 | Supplying and fixing cable route marker with 10 cm X 10cm X5mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 63 | HT CABLE LAYING |
| 64 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. Above 120 sq. mm and upto 400 sq. mm |
| 65 | MV CABLE JOINTING & END TERMINATION |
| 66 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 10 sq. mm (22mm) |
| 67 | 3½ X 25 sq. mm (28mm) |
| 68 | 3½ X 35 sq. mm (32mm) |
| 69 | 3½ X 150 sq. mm (50mm) |
| 70 | 3½ X 185 sq. mm (57mm) |
| 71 | 4 X 10 sq. mm (25mm) |
| 72 | 4 X 16 sq. mm (28mm) |
| 73 | HV CABLE JOINTING & END TERMINATION |
| 74 | Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: 240 sq. mm |
| 75 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: 240 sq. mm |
| 76 | BLDC |
| 77 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factornot less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required. |
| 78 | LT PANELS |
| 79 | SITC of cubicle type mediumvoltage switch boards as per specificationsmentioned below, comprising ofACBs / MCCBs.,enclosed in 16 guage M.S.cubicle complete with angle iron frame work,panel doors ,horizontal andvertical busbars and outgoing feeders,FRP separators, phase barriers,gaskets for door, feeders designations, etc.,Main Switch Board shall be capable of withstanding 50 KA fault level. The panel shall be suitable for erection on the floor using channel and fastners at regular intervals in Sea shore area. (Panel should confirm to BIS,IE rules,EI/ EB Standards) |
| 80 | Main LT Panel |
| 81 | SITC of Main LT Panel comprising of : |
| 82 | Incomer |
| 83 | 1 No. 250A, 4P, 36kA Ics=Icw=Icu for 1sec Motorised, Microprocessor based MCCB with O/C,E/F (MCCB for transformer) 1 No. 200A, 4P, 36kA Ics=Icw=Icu for 1sec Motorised, Microprocessor based MCCB with O/C,E/F (MCCB for DG set) |
| 84 | 1 No. 250A, 4P ATS Syatem for AMF Operations (Automatic change over of transformer and DG Supply) |
| 85 | 1 Nos. 250A, 4P, 36kA Ics=Icw=Icu for 1sec Motorised, Microprocessor based MCCB with O/C,E/F (Outgoing of ATS) |
| 86 | 1 Set TPN AL: Bus bars with Corresponding current carrying capaciy. |
| 87 | Metering/Indication/Protection |
| 88 | Incomer side MFDM (V,A,F,Wh,W) with RS 485 communication port, Indication lamps for each feeders with indication lamps |
| 89 | Outgoing |
| 90 | 5 No 63A, TP+N, 36kA Ics=Icw=Icu MCCB; 2 No 50A, TP+N, 36kA Ics=Icw=Icu MCCB |
| 91 | Completewithallinterconnection , powder coatedapproved color control wiring,earth bus of adequate capacity & double earthing to all switches etc.as per ElectricalInspectorate/EB Standards. |
| 92 | APFC Panel - 25kVAR |
| 93 | SITC of APFC Panel comprising of : |
| 94 | Incomer |
| 95 | 1 No.63A, TPN, Isolator |
| 96 | Indication/Protection |
| 97 | 1 Set.R,Y,BLED type Phase Indicating Lamps with 2A SP MCB as control with Voltmeter. |
| 98 | 1 No. 8 STAGE APFC Relay. |
| 99 | 1 Set TPN AL: Bus bars Suitably rated |
| 100 | Outgoing |
| 101 | 1 No. 32 TP Capacitor Switching Contactor with 63 A TPN SFU withHRC Fuses Coupled with |
| 102 | 1 no 10KVAr Capacitor. |
| 103 | 1 No. 32A TP Capacitor Switching Contactor with 63 A TPN SFU withHRC Fuses Coupled with |
| 104 | 1 no 10KVAr Capacitor. |
| 105 | 1 No. 25A TP Capacitor Switching Contactor with 63 A TPN SFU withHRC Fuses Coupled with |
| 106 | 1 no 5KVAr Capacitor. |
| 107 | 1 No. 25A TP Capacitor Switching Contactor with 32 A TPN SFU withHRC Fuses Coupled with |
| 108 | 1 no 5KVAr Capacitor. |
| 109 | Completewithallinterconnection , powder coatedapproved color control wiring,earth bus of adequate capacity & double earthing to all switches etc.as per ElectricalInspectorate/EB Standards. |
| 110 | Common Panel |
| 111 | SITC of Floor Panel comprising of : |
| 112 | Incomer |
| 113 | 1No. 63A TPN Isolator |
| 114 | 1 Set TPN AL: Bus bars Suitably rated |
| 115 | Metering/Indication |
| 116 | 1 Set.R,Y,BLED type Phase Indicating Lamps with 2A SP MCB as control with Voltmeter. |
| 117 | 3 Nos. 0-50A Ammeter. |
| 118 | 3 Nos .50/5A,CL:1, 5VA CTs |
| 119 | Outgoing |
| 120 | 5Nos. 40A TP MCBas outgoings; 1Nos. 32A TP MCBas outgoings. |
| 121 | Completewithallinterconnection , powder coatedapproved color control wiring,earth bus of adequate capacity & double earthing to all switches etc.as per ElectricalInspectorate/EB Standards. |
| 122 | Lift Panel |
| 123 | SITC of Lift Panel comprising of : |
| 124 | Incomer |
| 125 | 1 No. 40, TPN Isolator. |
| 126 | 1 Set.R,Y,BLED type Phase Indicating Lamps with 2A SP MCB as control with Voltmeter. |
| 127 | 1 Set TPN AL: Bus bars Suitably rated |
| 128 | Outgoing |
| 129 | 1 No. 40 A, 4P, ISO + 1 Nos. 40 A, 4P, 100mA, ELCB ; 1 No. 25 A, DP, ISO + 1 Nos. 25 A, DP, 30mA, ELCB |
| 130 | 1 No. 10A, SP, MCB & 1 No. 16A, SP, MCB Outgoing of 1 No. 25 A, DP, ISO + 1 Nos. 25 A, DP, 30mA, ELCB |
| 131 | Completewithallinterconnection , powder coatedapproved color control wiring,earth bus of adequate capacity & double earthing to all switches etc.as per ElectricalInspectorate/EB Standards. |
| 132 | SUPPLY OF LT CABLES |
| 133 | Supply of XLPE insulated armoured cables with aluminium conductors for working voltages upto and including 1100V confirming to IS 1554 part I for PVC and IS 7098 Part I for XLPE |
| 134 | 3.5x185 Sq.mm Al XLPE Cable |
| 135 | 3.5x150 Sq.mm Al XLPE Cable |
| 136 | 3.5x35 Sq.mm Al XLPE Cable |
| 137 | 3.5x25 Sq.mm Al XLPE Cable |
| 138 | 4.0x16 Sq.mm Al XLPE Cable |
| 139 | 4.0x10 Sq.mm Al XLPE Cable |
| 140 | 4.0x6 Sq.mm Al XLPE Cable |
| 141 | 3.0x10 Sq.mm Al XLPE Cable |
| 142 | 3.0x4 Sq.mm Al XLPE Cable |
| 143 | MCCBs, MCBs & DBs |
| 144 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32A |
| 145 | Supplying and fixing 40 A 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required. |
| 146 | Triple pole |
| 147 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 148 | 25A |
| 149 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 150 | 25A |
| 151 | LIGHT FITTINGS / FANS |
| 152 | 36 W Panel Light : Recess mounted UGR < 16 LED luminaire equipped with CRCA powder coating housing with PS microprismatic diffuser for symmetric light distribution with non-integral energy efficient electronic driver. |
| 153 | 12W Recessed Light : 110lm/W; Wide operating Voltage/Rated Voltage-140-270V AC/ 220-240V AC /50Hz; THD<10% ; inbuilt Surge protection:3kV,class-II product, IK05;Higer Life; 50,000 BH@L70B50 ; Beam Angle- 120°; Colour Temp as Per Interior Requirement |
| 154 | 12W Surface mount Light : Wide operating Voltage/Rated Voltage-100-300V AC/ 220-240V AC /50Hz; THD<20% inbuilt Surge protection:2.5kV Class-I Product ; Life;30,000 BH@L70B50; Beam Angle- 110° ; Colour Temp as Per Interior Requirement |
| 155 | Tube Light : Wide operating Voltage/Rated Voltage-100-300V AC/ 220-240V AC /50Hz; THD <10% inbuilt Surge protection:2.5kV, class-I product,IK05 ;Beam Angle- 120° ; Colour Temp as Per Interior Requirement ; Life;30,000 BH@L70B50 |
| 156 | 10W Mirror Light :Vanity insanity (LARGE, BUILT-IN LED) Stainless steelvanity light |
| 157 | Exhaust Fan - BLDC Motor;20W Energy Efficient;ABC plastic ; 250mm Sweep; 1150CMH; Input Voltage: 140-285V, 1300 RPM |
| 158 | LIGHTNING PROTECTION |
| 159 | Air Terminal |
| 160 | Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3. For 1,2,3,4 meter air terminal 16mm rod tapered to 10 mm aluminium rodmeter rod: Meets the requirement (IS/IEC 62305). Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. System consist of Fang Fix with base and clamp on the top air terminal is erected. Air terminal Joining Clip Stainless Steel SS 304 clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform. Stainless Steel Wall Clamp or 16 KG stone of 365 mm diameter, high level of stability.No. of stones/wall clamps depending on wind load. Quick and easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked. Govt approved Indian labs test certificate required. Make: Cape/Dehn |
| 161 | 2meterairterminalwith Interception Tip mountedon Stainless Steel WallClamp mounting accessories. |
| 162 | Parapet / Down Conductors |
| 163 | Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below:Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Make: Cape/Dehn |
| 164 | Conductor with Down Conductor Holder made of whether resistant plastic holder @ every 0.75 meters |
| 165 | Conductor with Terrace Conductor Fibre Reinforce Concrete holder @ every 0.75 meters |
| 166 | T-Connectors |
| 167 | ProvidingandfixingofCrossConnector/TConnector/FoldingClamp/ClampingShoe/ Expansion Piece: to route vertical down conductor /mesh formation made ofAluminiumFerruleusingscrewfreejoints.FoldingClamp/ClampingShoeformetalpanels(upto 20mmthicknessofthemetalframe):Foldingclamp/clampingshoeformetalframe thicknessupto20mm,madeofstainlesssteelSS304/316grade, conformstothe requirements accordingto (IS/IEC 62305). Expansion piece with connector:Forequalising temperaturerelatedlengthchanges.Necessaryonconductorslengthat every 20 meters horizontally. Using round conductor 8mm aluminium conductor with straight Connector: usingAluminiumFerrule. Quick installation using crimp joints. Conforms to the requirements according to (IS/IEC62305).Makesurealljointsare strong and willbe inspectedatsite.GalvanisedIronjointsarenotpermittedtoavoidriskofcorrosion. Single bolt joints are not permitted to avoid risk of faulty loose joints and reduce risk of flash over. Govt approved Indian labs test certificate required. Make: Cape/Dehn |
| 168 | Test Joints |
| 169 | Providing and fixing of Stainless Steel Test Joint suitable with suitable Outdoor Enclosure: For 8mm dia solid round aluminium conductor & 10mmdiacopper coated solidsteel roundconductorhaving100micronsofcopperbonding.Conformstotherequirements according to(IS/IEC62305).Theenclosureshouldbeoutdoorglass-fibrereinforcedpolycarbonate opaque having minimum inner dimension of 75mm x 75 mm x 50 mm. Thetestlinkhastobestraightandneedsminimum4mountingscrewsforstrongjoints Inspection of bimetallic corrosion at site required. Seperation of 8mm Aluminium & 10mm Copper bonded steel is required for future inspection and contractor has to make sure both conductors permitted. Govt approved Indian labs test certificate required. Make: Cape/Dehn |
| 170 | Welded Joints |
| 171 | Installation of Exothermic WeldJoints for 10mm round copper bonded steel conductor having 100 microns as per IS/IEC 62305.Each under ground joints has to be wrapped withpetrolatum- coatedchemicalfibrefabrichaving1.1mmthickandwidth 50mm. Govt approved Indian labs test certificate required. Make: Cape/Dehn |
| 172 | Earth Pits |
| 173 | Providingandfixingofmaintenance freeEarthingsystemcomprises ofmolecularly bonded copper of 99.9% purity on low carbon steel of min 3048mm length (10 feet), having a diameter of 20mm with copper bonding thickness of 250microns asper UL 467. The Rod has to be either continuous or with self-coupling peg & bore arrangement with fault current withstand capability of 30 KA rms value for 1 second and I peak of 76 KA The rod must be having corrosion test, peel off test for uniform coating, 180 degree bend testwith out peeloff of copper bonding. Exothermic welded Clamp for clamping as suggested as per NBC 2016.Ordinary Stainless steel/Copper alloy universal clamps are not recommended. For self coupling peg & bore arrangement rod needs Impactpoint onthe bottom rod for easy insertion. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollutethe environment and non corrosiveto earth rod. Thematerial shouldhave aresistivity less than0.2Om. It should be free from hazardous substances.The mineral compound is required to have minimum 17.5 Kg ofthe total composite.The compound should be chemically inert and needs to submitGovt approved Indian labs test certificate. Concrete Earth electrode inspection chamber with weight bearing capacity of 50KN. The dimension shall be 320mmx 320mmx 190mm. Govt approvedIndianlabstestcertificaterequired. Make: Cape/Dehn |
| 174 | UPS |
| 175 | Supply, installation, and commissioning of 2X5kva UPS with PRS Configuration. Single phase in and out.with inbuilt isolation transformer at input (IP20), Input pf 0.99, it shall be 100% generator compatible, with Efficiency > 83 % and output power factor unity (5kVA = 5kW),including all accessories etc as required. The acoustic noise at 1m of the system should be<55dB.The system shall comply to IEC /EN 62040-1,2,3 and relevant IS standard along. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic & manual bypass switch. The system shall have IGBT rectifier and inverter. warranty 2 years ups and 2 years batteries. including rack and inter connecting cables. |
| 176 | 5 kva Load Minimum VAH 6240 x 2 setper UPS for 60 min backup SMF Battery of reputed approved make exide/quantaBattery Price for the above configuration 12v 26ahx 40 nos |
| 177 | Supply, installation, and commissioning of 2X10kva UPS with PRS Configuration. Three phase in and out.with inbuilt isolation transformer at input (IP20), Input pf 0.99, it shall be 100% generator compatible, with Efficiency > 95 % without transformer and output power factor unity (10kVA = 10kW), thdi <3 % including all accessories etc as required. The acoustic noise at 1m of the system should be<65dB.The system shall comply to IEC /EN 62040-1,2,3 and relevant IS standard along. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic & manual bypass switch. The system shall have IGBT rectifier and inverter. warranty 2 years ups and 2 years batteries. including rack and inter connecting cables. |
| 178 | 10 kva Load Minimum VAH 10080 x 2 setper UPS for 60 min backup SMF Battery of reputed approved make exide/quantaBattery Price for the above configuration 12v 42ahx 40 nos |
| 179 | SOLARPANEL |
| 180 | 20kwp Solar Panel |
| 181 | ELV |
| 182 | CCTV |
| 183 | Supplying and fixing of 25 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 184 | Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required. one run |
| 185 | Supplying and installing following size of perforated GI cable trays(galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, required bends, tees, reducesetc as required. 300 mm width X 50 mm depth X 1.6 mm thickness |
| 186 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 187 | DATA |
| 188 | Supplying and fixing of 25 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 189 | Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) |
| 190 | Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required. one run |
| 191 | Supplying and installing following size of perforated GI cable trays(galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, required bends, tees, reducesetc as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 192 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 193 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 194 | TELEPHONE |
| 195 | Supplying and fixing of 25 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 196 | Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required. |
| 197 | one run |
| 198 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. |
| 199 | Telephone socket |
| 200 | Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required. |
| 201 | 1 or 2 module( 75 mmx75 mm) |
| 202 | Supplying and installing following size of perforated GI cable trays(galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, required bends, tees, reducesetc as required. |
| 203 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 204 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 205 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 206 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 207 | TV |
| 208 | Supplying and fixing of 25 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 209 | Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required. |
| 210 | one run |
| 211 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. |
| 212 | TV antenna socket outlet |
| 213 | Supplying and fixing following size/ modules,GI box along with modular base, cover plate for modular switches in recess etc as required. |
| 214 | 1 or 2 module( 75 mmx75 mm) |
| 215 | Supplying and installing following size of perforated GI cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, required bends, tees, reducesetc as required. |
| 216 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 217 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 218 | CCTV CAMERA |
| 219 | Supply, Installation,testing and commissioning of IR Dome Camera with below specifications as minimum and with all the necessary accessories for the installation- 5 MP Resolution- 2.8/3.6 mm lens- H.264 / H.265- 30 meters IR range- WDR-120Db- Built-in IR LED- IP67- 3DNR, white balance, Privacy mask, BLC, HLC - Camera tampering detection, manual trigger, motion detection, periodical trigger, recording notification- 2 video Streams |
| 220 | Supply, Installation,testing and commissioning ofOutdoor type IR Bullet Camera with below specifications as minimum and with all the necessary accessories for the installation- 5 MP Resolution- 2.8/3.6 mm lens- H.264 / H.265- 30 meters IR range- WDR-120Db- Built-in IR LED- IP67- 3DNR, white balance, Privacy mask, BLC, HLC - Camera tampering detection, manual trigger, motion detection, periodical trigger, recording notification- 2 video Streams |
| 221 | Supply, Installation,testing and commissioning of 64 Channel NVR with below specifications as minimum and with all the necessary accessories for the installation- 64 Channel IP Cameras support- 8 SATA Ports ( Loaded with HDD for 60 days storage)- 2 Nos of 1G Ethernet Interfaces- Maximum users - 20 or higher- Raid 0/1/5/6/10 (Support global HDD hot-spare)- Ptotocols - HTTP, TCP/IP, IPv4/IPv6, UPNP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPOE, DDNS,FTP, iSCSI, IP Search, ONVIF (profile T/S/G), CGI, SDK- Trigger Events - Recording, PTZ, Tour, Alarm Out, Video Push, Email, FTP, Snapshot, Buzzer and Screen Tips- Recording Mode - Manual, Schedule (Regular, Continuous), MD (Video detection: Motion Detection, Tampering, Video Loss), Stop- Bandwidth - 320 Mbps- Backup-USB Device/Network/eSATA Device |
| 222 | Supply, Installation, Testing and Commissioningof LED Displays 32\"for CCTV Monitoring with all the necessary wall mounting accessories with HDMI Cable |
| 223 | DATA NETWORK System |
| 224 | Supply, Installation,Testing & Commissioning of 24 Port Patch panels CAT6 (1U with rear wire manager) 45°silver-plated IDCs (insulation displacement connection) for secure, reliable gas-tight connections |
| 225 | Supply, Installation,Testing & commissioning of CAT6 RJ45 I/O with a separator to eliminate crosstalk, Terminates 8 conductors at the same time reducing installation time, 45° silver-plated IDCs provide secure, reliable gas-tight connections |
| 226 | Supply, Installation, Testing & Commissioning of Ceiling Connector |
| 227 | Supply, Installation, Testing & Commissioning of CAT6 Patch Cord LSZH with Moulded boots Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable.- 1 Meter |
| 228 | Supply, Installation,Testing & commissioning of 12 Port LIU, 19\" rackmount, with adaptors, Swing-out splicetray in 1U Size. Should have front access for easy splice & patch management. Fuly loaded with SC MM Pigtails & adapters for all the cores. |
| 229 | Supply, Installation, Testing & Commissioning of 22U Network Rack with below specifications as minimum and all the necessary accessories - Height - 22U - Dimensions - 600 x 600 - Fan Units with 4 Fans - PDU 6 point - 1 Nos\"s - Mounting Hardware Kit (1 lot) - Tray - Front glass doors and back steel door and side panels |
| 230 | Supply, Installation, Testing & Commissioning of 48 PoE Layer -2 Port Network Switch 10/100/1000 Mbps with 2 SFP slots minimum loaded with 1G Uplink |
| 231 | Supply, Installation, Testing & Commissioning of48 Port Layer -2 Network Switch 10/100/1000 Mbps with 2 SFP slots minimum loaded with 1G Uplink |
| 232 | Supply, Installation, Testing & Commissioning of 1G SFP Modules |
| 233 | Supply, Installation, Testing & Commissioning of Enterprise Wi-Fi 5/6 Access Point - wall/ Ceiling Mount Type - Dual Radio - 5 Ghz and 2.5 Ghz |
| 234 | Fire Alarm System |
| 235 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steelchain & hammer assembly complete with glass and push button etc.as required. |
| 236 | Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm panel,central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 + 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance freebatteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integrationwith analog /digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet! Modbus over IP complete as per specifications. |
| 237 | Two Loop Panel |
| 238 | Fire Hydrant System |
| 239 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : |
| 240 | single headed gunmetal |
| 241 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : |
| 242 | Gun Metal |
| 243 | upplying & fixing 63 mm dia gun metal short branch pipe with 20mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: |
| 244 | Stainless Steel (Grade 304) |
| 245 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
| 246 | 30m |
| 247 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: |
| 248 | 4 way - 150 mm dia M.S. Pipe |
| 249 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 250 | 100 mm dia |
| 251 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, Gl bolts, nuts, washers etc.as required : |
| 252 | 100 mm dia |
| 253 | FIRE PUMPS & ACCESSORIES |
| 254 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump). |
| 255 | a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 |
| 256 | b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. |
| 257 | c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. |
| 258 | d) Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 259 | 900 lpm at 35 m Head |
| 260 | Fire Hydrant System |
| 261 | Supply and installation of Weather proof Outdoor type hose cabinets fabricated from 14 SWG M.S. sheet with full glass door with locking arrangement (Water Proof), suitable to accommodate 2 nos.15 M long hose and 1 No branch pipe. Glass will be transparent Acrylic - 3mm thick. The cabinet shall be painted with coat of P O Red paint from outside and white paint from inside including all accessories as required for complete installation.(size shall be such that the above all items can be accommodated). (Double door type) as per industrial standards |
| 262 | Supplying, laying, fitting and fixing , testing and commissioning of under ground GI heavy duty \"C\" class pipe confirming to IS 1239 The pipes shall have anti-corrosive wrapping coating and a wrapping treatment with pipe coat 4 mm thickness, after applying one or more coats of Asphalt primer. Rates shall include cutting, welding etc. bends, elbows reducers suitable for pipe joints, clamps and all other accessories including excavation of earth to sufficient depth to install the pipes, the pipes buried in ground excavation and refilling etc.as per the specification and as required complete as required for complete installation etc. including cutting holes in RCC walls/slabs and making good the same adequately supported on rigid supports duly painted as required complete in all respect including allup to building rising mains and for yard hydrants , |
| 263 | 100 mm dia |
| 264 | 80 mm dia |
| 265 | Supply & installation of Pressure Gauge with 0-300 psi (0-21Kg/Sq.CM) range white background, black graduation scale with dual reading in Kg/Sq.CM & PSI, 1/4\" BSPT bottom entry 100 MM dial, PHOSPHOROUS BRONZE bourden tube, brass moving parts, polished stainless steel case with positive seal against weather, moisture & dust, hardened glass, glycerine filled type with syphon tube and isolation cock,Make: Fiebig / H guru |
| 266 | Extinguishers |
| 267 | Supply and fixing Co2 type Fire Extinguisher of capacity 4.5 kg filled with Co2 Gas with control discharge mechanism ( squeeze grip type) fitted with Bend and Horn applicable on Class B and C class of fire. Manufactured and marked to IS 15683 with ISI marking and cylinders having the approval of Chief Controller of Explosives, and including all accessories as required for complete installation. |
| 268 | Supply and fixing of dry chemical powder type (DCP) fire extinguishers (ABC Type) of 4 Kg capacity, Pressurized with nitrogen, mfg. to IS:15683 with ISI mark fitted with pressure gauge, GM cap nozzle complete with initial charges and installation brackets and screws with ISI marks etc. complete as approved and instructed by the engineer in charge including all accessories as required for complete installation.. |
| 269 | Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having llhermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules,microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 . |
| 270 | Supply of VRV/VRF system with out door units & required matching indoor units with remote controls |
| 271 | Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. |
| 272 | 1 TR Hi Wall Split Indoor Unit |
| 273 | 1.6 TR Hi Wall Split Indoor Unit |
| 274 | 2.5 TR Hi Wall Split Indoor Unit |
| 275 | Cordless Remote |
| 276 | Central Remote - Central Controller |
| 277 | Supply , Installation, Testing & Commissioning of Refrigerant Cu Piping with insulation |
| 278 | Supply , Installation, Testing & Commissioning of Drain Piping with insulation |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy