Tender For Annual Rate Contract For Housekeeping, Civil Maintenance, Hoprticulture Maintenance, Electrical And Telecom Maintenance Works At Iocl Pipelines Residential Colony, Korba, korba-Chhattisgarh

Indian Oil Corporation Limited-IOCL has published Tender For Annual Rate Contract For Housekeeping, Civil Maintenance, Hoprticulture Maintenance, Electrical And Telecom Maintenance Works At Iocl Pipelines Residential Colony, Korba. Submission Date for this Tender is 24-11-2023. AMC of Electric Tenders in korba Chhattisgarh. Bidders can get complete Tender details and download the document.




Tender Notice

40436182
Corrigendum : Tender For Annual Rate Contract For Housekeeping, Civil Maintenance, Hoprticulture Maintenance, Electrical And Telecom Maintenance Works At Iocl Pipelines Residential Colony, Korba
Open Tender
Indian
Chhattisgarh
korba
24-11-2023

Tender Details

Annual Rate Contract For Housekeeping, Civil Maintenance, Hoprticulture Maintenance, Electrical And Telecom Maintenance Works At Iocl Pipelines Residential Colony, Korba

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Nov-2023 Extension of bid submission period Date 24-11-2023

Key Value

Document Fees
Refer document
EMD
INR 135400.0 /-
Tender Value
Refer document

BOQ Items

Annual Rate Contract for Housekeeping, Civil Maintenance, Hoprticulture maintenance, Electrical and Telecom maintenance works at IOCL Pipelines residential colony, Korba NOTE: 1. Please enable macros before filling the rates to see the quoted figures in words. 2. The bidder shall quote firm prices “Excess(+)/ At Par/ Less(-)” against the rates mentioned in the price schedule provided in BoQ1 sheet as per instructions provided herein after taking into account all the tender terms and conditions and scope of work. In case rates are quoted to more than 2 decimal places then, the amount quoted towards the tender shall be worked out for the rates quoted to first 2 decimal points without rounding off.3. Only "Bidder Name", "Excess (+) or "At Par" or Less (-)" & "Percentage" are to b e filled by the bidder in the designated "Sky Blue cells". For "At Par" selection, the percentage quoted shall be treated as 0.00 and quoted amount at par with estimate. 4. "Excess (+)" or "At Par" or "Less (-)" can be selected from the dropdown menu by clicking on the cell. 5. No changes shall be made by the bidder to S.No., Unit, Quantity. 6. In case of any difference in item description/unit/quantity in BOQ, then the item description/quantity/unit given in the tender document shall prevail. 7.The rates quoted by the tenderer shall include all cost towards equipment, labour & laboratory back-up, logistics, transport, spares, tools, tackles, consumables, etc., travel and stay arrangements and other incidentals including supply of materials as may be necessary for rendering the services as per detailed specifications. 8. Goods and Services tax as per GST Act 2017 for concerned services has been added to the base price of below mentioned services. If the bidder wishes to quote some other Goods and Services tax rate other than mentioned in the price schedule provided in BoQ1 sheet, they may quote the same in "Annexure H". Statutory variation on Goods and Services Tax as applicable for the category/service shall be to Owner’s account up to the contractual completion period. Reverse charges mechanism on Goods and Services tax amount shall be applicable as per Govt. rules. 9. Bidders are advised strictly not to alter or change the BOQ format/ contents. Bidders are also advised not to paste any image file or put any additional conditions in the BOQ work sheet.Abbreviations: Unit - SQM - Square Meter, CUM - Cubic Meter, EA-Each, DAY-Days, KG-Kilogram, MON-Months, HR-Hours, L-Liter, M-Metre, FT2-Squarefoot, TON-Tonne Please note that rates of item nos. 20,30,40 & 50 are fixed and bidders quoted percentage will not have any impact on them.
Sl. No. Item Description
1FIXED PART-NOT TO BE QUOTED
2Housekeeping, cleaning, day to day miscellaneous civil works, scheduled Gardening works, plumbing works and electrical maintenance within colony premises . The work includes secheduled grass cutting, gardening, sweeping and cleaning of the road and drain, cleaning of roof, sweeping and washing o the quarters common area & front area, housekeeping and caretaking of community centre, collection of garbage from individual quarters and dumping of same in bio gas plant/other designated area, cleaning & emptying of dustbin, quarter plinth areas, cleaning of syntex overhead water tank as per schedule and requirement, cleaning of waste line, hume pipes and all plumbing work, operation and maintenance of water pump and associated pipelines, assistance during DG, HT panel, isolator O&M, fuel feeling, cleaning, Attending day-to-day electricalcomplaints,recording meter reading in G7 format, replacing fuses,six monthly cleaning of theelectricalfixture like tube light,ceiling fans & all electrical isolation / distribution boards, dressing of loose wires , fixingofloose connections, fixing and insulation of joints complete with all labour, tools and tackles and materialsetc. as per requirement and direction of EIC.(Work includes 08 unskilled and 02 skilled manpower)
3Skilled Manpower
4Unskilled Manpower
5PPE Cost (2 sets of uniform i.e 02 trousers, 02 shirts, 02 pairs of socks or boiler suit @ Rs. 3000 & one pair of safety shoe @ Rs. 800, helmet @ Rs. 200, waist coat/jacket @ Rs.500) @ Rs. 4500 per worker
6VARIABLE PART- Service charges for providing manpower
7Skilled Manpower
8Unskilled Manpower
9VARIABLE PART-Housekeeping & Civil Maintenance
10Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, all works up to any lead and lift, as directed by the Engineer-in-Charge : In all kinds of soil
11Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms including getting out the excavated soil and disposal of surplus excavated soil, all works up to any lead and lift, as directed by the Engineer-in-Charge : In all kinds of soil
12Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5m.
13Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to all leads, also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
14Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
15Surface dressing of the ground in all kinds of soil including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, all works up to any lead & lift as directed by the Engineer-in-Charge.
16Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
17Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
18Disposal of moorum/ building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to designated location/ approved municiple dumping ground for lead up to 10 Km and for all lifts, complete as per directions of the Engineer-in-Charge. [Note: This item shall also be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicles of 3.5 cum or more.]
19Providing and laying dry compacted hard base in layers using stone aggregate of 63 mm nominal size over the rammed hard compacted subgrade (for foundation columns, walls, dykes etc.), including spreading, ramming dry compacting complete in all respects inclusive of cost of all labour, materials and equipments etc. as per the specifications and direction of the Engineer-in-Charge.
20Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
211:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources]
221:3:6 [1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources]
231:4:8 [1 cement : 4 coarse sand (Zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources]
24Centering and shuttering including strutting, propping etc. and removal of formwork for :
25Foundations, footings, bases for columns
26Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
27Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc. including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering complete : 1:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources]
28Making plinth protection 50 mm thick of cement concrete 1:3:6 [1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources] over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth, etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
29Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources]
30Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 6mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing with cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.50 mm thick
31Casting, supplying and erecting in position precast reinforced cement concrete elements (with proper lifting lugs) for trench & drain covers, shelves, partitions, post, slabs etc. for all leads and levels including making necessarymoulds, vibrating, tamping, curing, finishing the top surface with cement mortar 1:3 (1 cement : 3 fine sand) to give a smooth and even surface, transportation to Site, aligning and fixing in position with cement mortar 1:3 (1 cement: 3 find sand,)including making recess in brick wall for placing the precast element in position and making good the same etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. [Note: Payment for Reinforcement shall be made as per relevant item of SOR.] : With cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 10 mm nominal size).
32Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level :Thermo-Mechanically Treated bars of grade Fe-500D or more
33Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in :Cement mortar 1:4 (1 cement : 4 coarse sand)
34Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
35Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: (A) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (B) Providing, fabricating, supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF/ Lumiflon based fluoropolymer resin coating of approved colour and shade on face #1 and polymer (Service) coating on face #2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (C) The fastening brackets of Aluminium alloy 6005 T5/ MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing. The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in square metre up to two decimal places.
36Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required diameter & length [Note: Hold fast lugs or Dash fasteners shall be paid separately under relevant item of SOR] : Second class teak wood
37Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
38Providing and fixing readymade stainless steel (304 Grade) Modular Kitchen Basket and accessories such as right angle basket (Plain Cup & Saucer, Plant, Partition, Bottle Rack, Thali, Cutlery), Kitchen Utensil Basket, Dinner Set Basket, Kitchen Grain Basket, Multipurpose Basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, stainless steel screws and telescopic channel, etc. as per direction of the Engineer-in-Charge. [Notes: (1) For payment purpose, only weight of stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners, Telescopic Channels, etc. (2) Payment for providing & fixing telescopic channel shall me made separately under relevant item of SOR].
39Providing and fixing 35 mm thick wire mesh door shutter for entrance doors made of styles and rails of 35 mm thick 2nd class teak wood, galvanised M.S. wire mesh (gauze) of average width of aperture 1.18 mm with wire of dia 0.56 mm including necessary fittings such as heavy type oxidised brass butt hinges with necessary brass screws, anti-termite, wood borer treatment, painting/ polishing to required shade etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
40Providing and fixing 450 mm deep storage cabinet (All types- low height, full height and over head) with boxing and shutters finished with 19 mm thick pre-laminated block board of BWP Grade, Decorative type (BWP-DEC) of approved quality or equivalent stamped with IS-1659:2004 (Latest Edition) and pre-lamination should conform to IS-2046:1995 (Latest Edition) with, 1.5’ x 1.25’ mm rubber wood/ C.P. teak moulding, complete in all respect including all hardware and polishing of wooden surfaces in natural shade with melamine as per drawings, specification and directions of the Engineer-in-Charge. [Note: Elevation area shall be measured for payment purpose.]
41Providing and fixing in position built-up cupboard, internal framework, shelves, drawers, layon slides partitions and shutters 19 mm thick pre-laminated block boardof BWP Grade, Decorative Type (BWP-DEC) of approved quality or equivalent stamped with IS-1659:2004 (Latest Edition) and pre-lamination should conform to IS-2046:1995 (Latest Edition) and 3 mm thick teak wood lipping at all edges of the board with polish/ enamel paint fixed with water resistant adhesive on inside and external face as per approved shade including piano type hinges 19x25 mm, best quality teak wood lipping around the shutter edges, 20 mm diameter chrome plated M.S. coat hanger rod, magnetic ball catchers, brass tower bolt, knobs, handles with S.S. roses 150 mm x 19 mm diameter (Ref. Make - DORSER, Model - IP 06 PR SS or approved equivalent) complete as per drawing including spirit polishing/ enamel painted on lipping in required shade matching to the laminate etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Engineer-in-Charge. (Measurement of cupboard shall be taken as front area of shutters only): For room wardrobes.
42Providing and fixing in position loft shutters with 19 mm thick pre-laminated block board of BWP Grade, Decorative Type (BWP-DEC) of approved quality or equivalent stamped with IS-1659:2004 (Latest Edition) and pre-lamination should conform to IS-2046:1995 (Latest Edition) and 3 mm thick teak wood lipping at all edges of the board with polish/ enamel paint fixed with water resistant adhesive on inside and external face as per approved shade including piano type hinges 19x25 mm, best quality teak wood lipping around the shutter edges, magnetic ball catchers, brass tower bolt, knobs, handles with S.S. roses 150mm x 19mm diameter (Ref. Make - DORSET, Model - IP 06 PR SS or approved equivalent) etc. and frame size 50x35 mm in 2nd class teak wood complete including spirit polishing/ enamel painted on lipping in required shade matching to the laminate, fixing of frame to wall with hold fasts, 1:2:4 RCC etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (Measurement of cupboard shall be taken as front area of shutters only): For loft shutters.
43Providing and fixing approved stainless steel finished tower bolts (barrel type) 10 mm diameter & 200 mm long with screws etc. complete as per drawings, specification and directions of the Engineer-in-Charge.
44Providing and fixing approved stainless steel finished sliding bolt 16 mm diameter & 250 mm long with required colour or shade with nuts and Screws etc. complete as per drawings, specification and directions of the Engineer-in-Charge.
45Providing and fixing approved cylindrical lock of "ACME KASA" or equivalent with required colour or shade with nuts and screws etc. complete as per drawings, specifications and directions of the Engineer-in-Charge.
46Providing and fixing magic eye piece in front door with necessary screws etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles, etc. as per drawings, specifications and directions of the Engineer-in-Charge.
47Providing and fixing heavy duty concealed type aluminium alloy hydraulic door closer of "DOORKING" or approved equivalent make & quality with necessary accessories, screws etc. and matching colour plate complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
48Supplying, fabricating and fixing M.S. structural steel work made of joists, tubes, pipes, channels, angles, plates, flats, bars etc., for struts, chain link fencing posts as per drawing includinggate, ladders, safety grills, walkways, collapsible gate, signboards, supports for cable trench, making slots for barbed line, wire hoisting, placing in position, embedding in concrete, applying two coats of epoxy paint "EPILUX 155" High Build Enamel over a coat ofEPILUX 610 Primer of M/s Berger or any other approved equivalent make as permanufacturer’s recommendation, complete in all respect including cutting to required size welding of joints, fixing anchor plates,bolts, theading, nuts, washers, sleeves etc. and necessary lettering of approved pattern on main gate, signboards etc.complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (excluding the cost of concrete work).
49Supplying and fixing, shop fabricated M.S. steel Electroforged Welded Gratings (Hot dip galvanised as per IS:2629 and tested as per IS:2633 and IS:6745) of approved make with quantity of zinc coating shall not be less than 9.0 N/sqm of surface area (0.12 mm uniform thickness) over drains, stair treads etc., wherever required with maximum size of void/ mesh in the grating limited to 33 mm x 50 mm including welding/ fixing/ clamping to base frame, etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
50Supplying at site welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer. [Note: Priming & Painting to be paid for separately].
51Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the directions of the Engineer-in-Charge :
52Made of G.I. wire of dia 4 mm
53Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade.
54Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) : Light shade pigment using white cement Light shade pigment using white cement
55Providing and laying flamed finish Granite stone slab (Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent) flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
56Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
57Providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of first quality conforming to IS:15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/sq.m. including pointing the joints with white cement and matching pigment, etc. complete.
58Providing and fixing ceramic glazed floor tiles of first quality conforming to IS:15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by the Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg/sq.m. including pointing in white cement mixed with pigment of matching shade complete.
59Providing and laying Double Charge Vitrified Tiles (polished finish) of specified sizes (thickness to be specified by the Manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacture, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily :Size of Tile 600 x 600 mm
60Providing and fixing on wall face Unplasticised Rigid PVC (uPVC) rainwater pipes (110 mm diameter, single socketed) conforming to IS:13592 Type-A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion.
61Providing and fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS:737 and dimensions as per IS:2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/ tappping stainless steel screws M6, 60 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc.complete as per directions of the Engineer-in-Charge. [Note: Cost of truss/ framework shall be paid separately under relevant item of SOR].0.56 mm, Aluminium colour coated troughed profile with centre to centre pitch of 200 mm, depth of 32 mm, overall profile width 1092 mm, cover width 1000 mm.
62Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/sq.m., both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using G.I. slotted cleats of size 27x37x25x1.6 mm fixed to ceiling with 12.5 mm dia. and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised butterfly level clips of size 85x30x0.8 mm spaced at 1200 mm center to center along main "T", bottom exposed width of 24 mm of all "T"-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by the Engineer-in-Charge :2.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS:2095 (Part-1), of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm center to center with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.
63Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/ tiles of size 595 x 595 mm, having NRC (Noise Reduction Coefficient) of 0.50 (minimum) as per IS 8225:1987, Light Reflectance of 85% (minimum). Non-combustible as per BS:476 (Part-4), Fire Performance as per BS:476 (Part 6 &7), Humidity Resistance of 100%, Thermal Conductivity < 0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @ 120 grams per sqm including both sides) i.e. vertical studs of size 48x34x36 mm are placed at 600 mm center to center in a floor and ceiling channel section of size 50x32 m fixed to the floor and soffit at 600 mm centers using 12 mm dia, 50 mm long wedge type expanded zinc alloy dash fastner with 10 mm bolt. This same channel is then to be fixed in horiziontal direction at 600 mm center to center so as to form a grid of 600 mm x 600 mm. Glasswool of 50 mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/ tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13x3.2 mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50 mm wide (90 metre) roll and two coats of primer suitable for panelling as per manufacturer"s specification as per directions of the Engineer-in-Charge all complete : With 15 mm thick fully perforated square/ butt edge light weight calcium silicate panels/ tiles.
64Providing and fixing Plaster of Paris (POP) false ceiling consisting of framework made with 50 sq.mm. M.S. tubes of 18G thickness as main runners at 600 mm c/c both ways, suspended/ supported with M.S. flats 25x4 mm from existing R.C.C. slab including providing and fixing minimum 10 mm thick POP (Calcium Sulphate Semihydrate variety) jute reinforced tiles of 600x600 mm size of plain or of approved design finished smooth to line and level including necessary supports, scaffolding etc. as required including applying a coat of red oxide zinc chromate primer over the M.S. framework and suspenders, etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
65Providing gola 75x75 mm (in 75x75 mm deep chase) in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design.
6612 mm cement plaster of mix :
671:4 (1 cement : 4 fine sand)
681:6 (1 cement : 6 fine sand)
6912 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement : 3 fine sand)
70Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
71Providing & fixing galvanized chicken wire net 20 Gauge, 20 mm mesh size in plastering work at the junction of RCC Columns/ Beams & brickwork as directed by the Engineer-in-Charge.
72Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer.
73Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification : Two or more coats on new work
74Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
75Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
76Finishing walls with 100% Premium Acrylic Emulsion paint having VOC less than 50 gms/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives :
77Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr/10 sqm
78Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture.
79Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer"s specifications including appropriate priming coat, preparation of surface, etc. complete : On steel work
80Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
81Lettering with black Japan paint of approved brand and manufacture. [Note: Unit "EA" shall mean "PER LETTER PER CM HEIGHT"].
82Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
83Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour :
84One coat
85Two coats
86Repair to plaster of thickness 12 mm to 20 mm in patches of area up to 2.5 SQM including cutting the patch in proper shape, raking out joints, preparing and plastering the wall surface etc. complete, including disposal of rubbish at unobjectionable area outside Ownder"s premises, all complete as per directions of the Engineer-in-Charge : With cement mortar 1:4 (1 cement : 4 fine sand)
87Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15x10x10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per directions of the Engineer-in-Charge :
88Door chowkhats
89Window chowkhats
90Clerestory window chowkhats
91Renewing glass panes, with putty and nails wherever necessary including racking out the old putty : Float glass panes of nominal thickness 5.0 mm (weight not less than 10 Kg/sqm)
92Renewing bottom rail and/or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturer.
93Renewing Wrought Iron/ M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete : Wheel above 50 mm dia. [Note: Unit "EA" shall mean "PER WHEEL"].
94Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs, etc. wherever necessary complete : 25mm dia
95Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete.
96Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete : 100x70x4 mm (ordinary type)
97Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of the Engineer-in-Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. [Note: This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done]
98Providing and fixing bright finished brass casement window fasteners or peg stays to windows/ ventilators with necessary welding and machine screws etc. complete.
99Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per the directions of Engineer-in-Charge.
100Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per the directions of Engineer-in-Charge.
101Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87-0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : (a) Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. (b) Tear strength in longitudinal and transverse direction as 60/80N. (c) Softening point of membrane not less than 150°C. (d) Cold flexibility shall be up to -2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane.
102Providing and applying crystalline mortar by mixing in the ratio of 4.5:1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled & honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystallie mortar shall conform to the EN 1504-3 having compressive strength Class R4 > 45 MPa and adhesive bond strength Class R3 > 1.5 MPa. The work shall be carried out all complete as per specification and directions of the Engineer-in-Charge. The product performance shall carry guarantee for 10 years against any leakage.
103For sealing cracks and faulty construction joints, by preparing the surface, making U-shape groove size of 25x25 mm and then priming the surface with integral crystalline slurry @ 0.05 Kg per running meter and while the surface is tacky then filling the groove upto top edge with crystalline mortar @ 1.50 Kg per running meter. Once crystalline mortar is touch dry then finally applying two coats of integral crystalline slurry @ 0.05 Kg per running meter per coat on treated surface.
104For patching of tie rod holes, preparing tie rod hole surface and then priming the area with integral crystalline slurry @ 0.070 Kg per sqm and while the surface is tacky, repairing and then filling the tie rod holes with crystalline mortar @ 0.040 Kkg per hole. The crystalline mortar shall be tightly rodded into tie rod holes or packed tightly. [Notes: (1) For 25x25x25 mm tie rod hole, use 0.040 Kg to fill the hole. (2) Unit "EA" shall mean "EACH HOLE"]
105Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations. (3) Cutting of all reinforcement shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge]
106Demolishing brick work in cement mortar manually or by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations]
107Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations. (3) Cutting of steel shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge.]
108Providing and laying factory made chamfered edge interlocking Cement Concrete paver blocks in foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer"s specifications & directions of the Engineer-in-Charge :60mm thick Cement Concrete paver block of M-35 grade with approved colour, design & pattern.
109Providing and fixing white vitreous china pedestal type water closet (European type) (Ref. Make: HINDWARE, Model: Cat No.-20058 or equivalent approved) with seat and lid, 10 litre low level white vitreous china dual flushing cistern (Ref. Make: HINDWARE, Model: Cat No.-21028 or equivalent approved) & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
110Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS:2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
111Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
112Providing and fixing Stainless Steel A ISI 304(18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :510x1040 mm bowl depth 250 mm
113Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete : 10 litre (full flush) capacity - White
114Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : White solid plastic seat with lid
115Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.
116Providing and fixing C.P. Brass 32 mm size Bottle Trap of approved quality & make and as per directions of the Engineer-in-Charge.
117Providing and fixing 15 mm nominal diameter C.P. Brass single lever telephonic wall mixer of quality & make as approved by the Engineer-in-Charge.
118Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete : Flexible Pipe : 40 mm diameter
119Providing and fixing 100 mm sand cast Iron grating for gully trap.
120Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
121Providing and fixing toilet paper holder : C.P. Brass (Ref. Make: JAQUAR, Model: Cat. No.-1151 or approved equivalent).
122Providing and fixing the following washroom fittings, complete in all respects; inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge : Stainless steel liquid soap container (spring loaded push type) with lid and brackets fixed to P.V.C. cleats with C.P. brass screws, etc.
123Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with wooden cleats and C.P. brass screws etc. complete.
124Internal Work - Exposed on wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per directions of the Engineer-in-Charge :
12525 mm nominal outer dia pipes
12650 mm nominal outer dia pipes
127Internal Work - Concealed in wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per directions of the Engineer-in-Charge :
12825 mm nominal dia pipes
12932 mm nominal dia pipes
130Internal Work - Exposed on Wall: Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. :
13125 mm dia nominal bore
13250 mm dia nominal bore
133Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :
13450 mm nominal bore
13580 mm nominal bore
136Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
137Providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete :25 mm nominal bore
138Providing and fixing following C.P. Brass central hole wash basin mixer with copper pipe/ pipes and brass nuts of size 15mm, etc. complete including cutting & making good the walls wherever required complete in all respects as per specifications and directions of the Engineer-in-Charge :C.P. central hole wash basin mixer (Ref. Make: JAQUAR, Model: Cat. No.-7171 Queen"s or approved equivalent) with 2 nos. x 10mm diameter & 450mm long copper pipes.
139Providing and fixing 15mm diameter C.P. brass shower arm (Ref. Make: JAQUAR, Model: Cat. No. 477 + 493 or approved equivalent) with concealed stop cock (Ref. Make: JAQUAR, Model: Cat. No. 083 or approved equivalent) including cutting & making good the walls wherever required, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles, etc. as per specifications and directions of the Engineer-in-Charge.
140Providing and fixing 15mm diameter C.P. brass shower mixer (Ref. Make: JAQUAR, Model: Cat. No. 273 or approved equivalent) and shower (Ref. Make: JAQUAR, Model: Cat. No. 477 + 493 or approved equivalent) including cutting & making good the walls wherever required, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge.
141Providing and fixing C.P. kitchen sink mixer with raised "J" shaped swinging casted spout ((Ref. Make: JAQUAR, Model: Cat. No. 319 or approved equivalent) and 2 nos. x 450mm long copper pipes and brass nuts & fittings of size 15mm, including cutting and making good the walls/ counter wherever required, etc. complete in all respects as per specifications and directions of the Engineer-in-Charge.
142Providing and fixing 15mm diameter C.P. brass tap as per following with C.P. brass flange including cutting & making good the walls wherever required, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge :
143Bib Cock (Ref. Make: JAQUAR, Model: Cat. No. 0107 or approved equivelent)
144Bib Cock (Ref. Make: JAQUAR, Model: Cat. No. 0041 or approved equivelent)
145Bib Cock (Ref. Make: JAQUAR, Model: Cat. No. 0309 or approved equivelent)
146Bib Cock (Ref. Make: JAQUAR, Model: Cat. No. 7037 or approved equivelent)
147Providing and fixing 15mm diameter C.P. brass angle valve as per following with C.P. copper connecting pipe 375mm long or as required including nuts, washers, C.P. brass flange, etc. including cutting & making good the walls wherever required, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge :
148Angle Valve (Ref. Make: JAQUAR, Model: Cat. No. 0053 or approved equivalent)
149Angle Valve (Ref. Make: JAQUAR, Model: Cat. No. 7053 or approved equivalent)
150Providing and fixing 15mm diameter C.P. brass stop cock with wall flange (Ref. Make: JAQUAR, Model: Cat. No. 0933 or approved equivalent), male end with C.P. copper connecting pipe 375mm long or as required including nuts, washers, C.P. brass flange etc. including cutting & making good the walls wherever required complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge.
151Providing & fixing Angle Valve(Ref. Make: JAQUAR, Model: Cat. No. 563 or approved equivalent) and Health Faucet with flexible tube 8mm diameter x 1.5 m long (Ref. Make: JAQUAR, Model: Cat. No. 549 or approved equivalent).
152Providing and placing on terrace (at all floor levels) polyethylene water storage tank (Ref. Make: SINTEX or approved equivalent), IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
153Cleaning of terrace/ loft water storage tank (inside surface area) up to 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per the directions of Engineer-in-Charge. [Note: The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any G.I. fittings or ball cock is damaged that is to be repaired by the Contractor at his own cost and nothing extra will be paid on this account].
154Cleaning of underground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations: (1) Tank shall be emptied of water by pumping & bottom shall be cleaned of slit and otherdeposits. (2)Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (3) Chlorination of RCC internal surface by liquid chlorine. (4) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (5) Finally the surface shall be treated with ultra-violet radiation etc. as per direction of the Engineer-in-Charge.
155Disconnecting damaged overhead/ terrace PVC water storage tankof any sizefrom water supply line and removing from the terrace including shifting at ground level as per the directions of Engineer-in-Charge.
156Providing and laying non-pressure NP-2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150mm
157Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separately] : Anodised Aluminium (Anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of Grade AC-15)
158Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade-l Type-ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. Brass/ Stainless Steel screws etc. complete as per architectural drawings and directions of the Engineer-in-Charge : Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side.
159Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS:6315, having brand logo embossed on the body/ plate with double spring mechanism and door weight up to 125 Kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per directions of the Engineer-in-Charge. : With stainless steel cover plate minimum 1.25 mm thickness
160Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) After surface preparation, first layer of slurry of cement @ 0.488 Kg/sqm mixed with water proofing cement compound @ 0.253 Kg/sqm. (b) Laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 Kg/sqm mixed with water proofing cement compound @ 0.670 Kg/sqm and coarse sand @ 1.289 Kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) Fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured.
161Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 litre/10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/ system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per directions of the Engineer-in-Charge.
162Providing and applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @ 14.35 Kg/10 sqm. One coat of self priming of cementatious waterproofing polymer (dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per directions of the Engineer-in-Charge.
163Providing barricading of 3.0 m height made of 1mm thick G.S. corrugated sheet with steel angle post (ISA65x65x6) at every 1.5 m interval and steel angle bracings (ISA 50x50x6) at every 3.0m interval, embeding posts in cement concrete (1:2:4) padestals of size 450mm x 450mm x 750mm), providing necessary bolts, nuts, fixing, etc. including painting of steel sheet and angles with two coats of aluminium/ synthetic enamel paint over a coat of red oxide zinc chrome primer, inclusive of cost of all labour, material, tools, tackles, etc. complete in all respects as per drawing, specifications and directions of the Engineer-in-Charge. [Note: This item shall be operated under specific approval of the Engineer-in-Charge].
164Supplying and stacking of good earth at site including royalty and carriage up to any lead complete. [Note: Volume of earth measured in stacks will be reduced by 20% for payment].
165Supplying and stacking sludge at site including royalty and carriage up to any lead complete. [Note: Volume of sludge measured in stacks will be reduced by 8% for payment].
166Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.
167Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete. [Note: Cost of sludge, manure or extra earth shall be paid for separately under relevant item of SOR].
168Providing and laying Neelgiri/ Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, complete as per direction of the Engineer-in-Charge.
169Supply and planting sapling (not less than 45 cm in height and 60 cm centre to centre) of Casurina, Labrum, Gulmohar, Ashokas, Bottle Palm, Bougenvilla, Hibiscus, Roses or other approved type of variety of plants, watering & maintenance for 30 days minimum complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge.
170Providing and fixing M.S. tree guard 50 cm square in plan, height 1.40 metre above ground level and 0.50 metre below ground level. The vertical members shall consist of 4 Nos of angle iron of size 25x25x5 mm & 1.9 m long, one at each corner and 8 Nos flat iron of size 25x5 mm & 1.4 long. The vertical members shall be welded to 4 Nos 25x6 mm M.S. flats placed horizontally around the vertical member of the cage. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered IOCL or any other approved name. The tree guard shall be fixed to the ground by making suitable holes and by embedding four corners leg in the ground, including refilling the earth, compaction etc. complete. The tree guard shall be painted with two coats of paint of approved brand and manufacture over a coat of primer, complete in all respect.
171Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure. [Note: The good earth shall be paid for separately under relevant item of SOR].
172Cutting of hedge/ edge including removing of cut material, cleaning, hoeing of hedge/ edge, bed watering, manuring and applying insecticides and fungicides etc. (excluding the cost of all materials) complete as per directions of the Engineer-in-Charge. [Note: Unit "SQM" shall mean "PER SQM PER MONTH".]
173Cutting of designer hedge/ edge including removing of cut material, cleaning, hoeing of hedge/ edge, bed watering, manuring and applying insecticides and fungicides etc. (excluding the cost of materials) complete as per directions of the Engineer-in-Charge. [Note: Unit "SQM" shall mean "PER SQM PER MONTH".]
174Topairy cutting/ shaping of plants including removal cut materials, cleaning, hoeing of plants, design of trees (Topairy), watering, manuring, etc. (excluding the cost of materials) complete as per directions of the Engineer-in-Charge.
175Height of Topairy up to 120 cm [Note: Unit "EA" shall mean "PER TREE PER MONTH"]
176Height of Topairy above 120 cm [Note: Unit "EA" shall mean "PER TREE PER MONTH"]
177Pruning, trimming, shaping of trees/ shrubs (height 15 feet & above) and removal of cut materials up to 50m lead inclusive of all labour, T&P, materials etc. complete as per direction of the Engineer-in-Charge. [Note: Unit "EA" shall mean "PER TREE"].
178Providing and watering of Horticulture features i.e. lawn, tree, shrubs, hedge/ edge, ground cover etc. with irrigation water at the site of work. Watering shall be done through water tanker having 5000 litre capacity with one labour for watering including cost of water, filling of tanker, watering at site with all leads and lifts as per direction of the Engineer-in-Charge. [Note: Unit "EA" shall mean "PER TRIP"].
179Anti-termite treatment of trees by digging holes 30 cm deep & 4 cm dia, 6 to 7 holes around the tree using chemical emulsion (Chlorpyriphos 20% EC in the ratio of 1% concentration) at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection, complete as per directions of the Engineer-in-Charge. [Note: Unit "EA" shall mean "EACH TREE"].
180Cleaning and Sweeping of Lawn/ Garden area and keep it neat & clean by mechanized method/ manually, removimg litter, debris, picking of leaves, papers, plastic bottles etc. including disposal of collected waste in dustbin/ designated place, as per direction of the Engineer-in-Charge. [Note: All T&P, materials/ articles shall be provided by the Contractor].
181Removal of garden waste by TATA 407 or equivalent capacity vehicle including loading/ unloading, carriage up to 1.0 Km lead & disposal at designated place etc. complete as per direction of the Engineer-in-Charge. [Note: Unit "EA" shall mean "PER TRIP"].
182Electrical Maintenance
183SAFETY EQUIPMENT Supplying the following Safety Equipment as per directions of Site Engineer / Engineer-in-Charge
184RUBBER HAND GLOVES : Rubber hand gloves suitable for 11/6.6 KV operation with ISI mark.
185INSULATING MATS:installation of 2000 mm X 1000 mm and of thickness as mentioned below, approved quality insulating Elastomermats as per specifications.
186Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2 mm (Class A)
187Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2.5 mm (Class B)
188Cable Laying Layingofall typeof cables LT (PVC / XLPE /Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles,columns, in conduits, in panels and on structures etc.;including the supply and installation of all required materialssuch as fixingclamps ,screws, cable straps,tags etc.as required (other than the supplyof the conduits, cables, pipes, cable racks, trays,poles,structures and panels) completeinall respect, including cost of alllabour, tools, consumable materials etc. and cutting the cables in required lengths asper drawings, specification and directionsofSite Engineer / Engineer-in-Charge
189Power cables LT : OD upto 20 mm
190Power cables LT : OD above 20 mm and upto 40 mm
191Power cables LT : OD above 40 mm and upto 60 mm
192Power cables LT : OD above 60 mm
193Control cables (T&I) : OD upto 20 mm
194LT Cable joint (1.1 KV): Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M) , materials, labour, tools and tackles, consumables etc , asper drawings, specification and directionsofSite Engineer / Engineer-in-Charge
195Power cables LT : OD upto 20 mm
196Power cables LT : OD above 20 mm and upto 40 mm
197Power cables LT : OD above 40 mm and upto 60 mm
198Power cables LT : OD above 60 mm
199Control cables LT : OD upto 20 mm
200EARTH ELECTRODES Supplying, installation, testing of GI earthing electrode, including the supply and installationof the CI cover, charcoal /special backfill etc. and construction of chamber; complete asper drawings,specifications and directions of the Site Engineer, Including thecostof alllabour, tools, materials etc. completein all respects.
201EARTH STRIP / WIRE / ROPE / CABLE Supply, installing and testing of earthing strip/wire/rope/cable forcompletely making the earthing grid system by supplying, laying theGI / Cu strip and makingall the necessaryweldingjoints, connecting to the earthing electrodesand existing earthinggridetc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-charge, including the cost of all labour, tools, materials, etc. complete in all respect.
20250 mm X 6 mm G.I. earthing strip
20340 mm X 5 mm G.I. earthing strip
20425mm x 3 mm copper flat
205GI wire / rope 35 sq. mm
206GI wire / rope 10 mm diameter
207Point wiring supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade including earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installation of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes,junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . Thecircuit wiring with 4 Sq.mm PVC copper wire from D.B. to switchboard as required is also in the scope of the contractor.
2081 light point controlled by 1 switch.
2092 light points controlled by 1 switch
2103 light points controlled by 1 switch
211Wiring with PVC insulated 2.5 sqmm copper conductor wire for fan points (1 fan point controlled by 1 modular switch) including providing space for electronic regulator in switch box , providing and fixing fan hook in the ceiling as per specifications and drawings.
212Wiringfor 250 V single phase and neutral 16 amps modular power plug point with PVC insulated 4 sq. mm. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 2.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 6 pin 16/6A modular socket and 20/10 A modular switch (1 plug point per circuit) as per specifications and drawings
21312" Oscillating wall mounted bracket fan, noiseless, plastic moulded construction, rotary device for 3 step speed control integrated unit of approved make with all accessories complete in all respect.
214PVC Conduit pipes Supply, installation, fixing in position, PVC conduit pipes, of ISI marked , in concrete, brick work etc. during or after construction by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providing necessary tees, bends, junction boxes etc. with 12 SWG GI wire inside conduit without joint for concealed wiring, including making good the concrete, brick work, surfaces etc. complete as per drawings and direction of Site Engineer / Engineer-in-charge including cost of all labour, materials etc.
21525 mm
21632 mm
217Supply, installation, connection, testing and commissioning of the following post top lantern lighting fixtures of Philips/ approved equivalent make suitable for different lighting poles and laying, connecting 4x4 sqmm Al. unarmoured cable from marshalling box to fitting through pole complete with lamps (lamps cost will be paid separately) and necessary control gear including supply of all wires, clamps, supports, etc. all complete with labour and materials as per drawings, specifications and directions of Engineer-in-Charge..
218Decorative Light fittings Supply, installation, connection, earthing and testing of the following fittings,including supply and installation of drop pipes, hooks, fittings, fixtures, nuts,bolts, supports, on walls, outlet box for regulators and all other required materials etc. as per specifications, drawings and directions of the Site Engineer including cost of all labour, tools, materials etc. complete in all respects.Make of the fittings can be the make mentioned in the respective SOR items or equivalent model from the approved make list given in the specifications.
219LED Ceiling Point: Supply and fixing of surface mounted LED ceiling light fitting type Mainstream spot Aura 15W of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation
220Supply and fixing of Bollard LED light fitting type BCP150/WW PSU 220-240V 7043 of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation
221Supply and fixing of LED wall light cat. no. 35022 9W fitting of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation
2221.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40%
223AL,3CX10 mm²,A2XFY
224AL,4CX16 mm²,A2XFY
225AL,4CX25 mm²,A2XFY
226AL,3.5CX50 mm²,A2XFY
227Supply,fixing and connection of 250V flush type/tumbler Anchor make or approved equivalent switch,socket bellpush etc.on perpex sheet on MS box inlcuding supply and fixing of nuts,bolts,etc.butexcluding the perpex sheet all complete with labour and materials as per direction of the Engineer-in-Charge.
2281 way 5 / 6 amps. Piano/flush type switch with ISI mark
2291 way 15 / 16 amps. Piano/flush type switch with ISI mark
2303 pins 5 / 6 amps. Penta flush socket outlet
2313 pins flush type 15 / 16 amps. socket outlet
2322 plate ceiling rose
233Deluxe Musical Bell
2346 amp 3 pins switch socket combined ISI marked
23516 amp 3 pins switch socket combined ISI marked
236Dimmer 400W / fan regulator
237Supply, fixing and connection of 250 V below given mosaic wiring accessories of M/s MDS or approved equivalent inlcuding supplying and fixing of nuts,bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.
2386 amps. - 1 way - SP - 1 module switches
23916 amps. - 1 way - SP - 1 module switches
2406 amps. - 2 / 3 pins combined 2 module shutterred socket
2416 / 16 amps. - 3 pins combined 3 module shutterred Socket
2422 pins - 1 module telephone socket
243"L" SERIES MCB SUITABLE FOR LIGHTING AND OTHER DOMESTIC LOADS Supplying and fixing of following rating 240 volts, 50Hz, 10KA "L" series, miniature circuit breacker (suitable for lighting and other domestic loads and conforming to IS 8828: 19) of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Note: ISI marked MCBs of Havells / Loadster / Indo Kopp make shall be used.
2445 To 32 Amp
24540 Amp
2465 A TO 32 A "G" SERIES MCB SUITABLE FOR MOTORL AND OTHER INDUCTIVE LOADS Supplying and fixing 5 amps. To 32 amps. Rating, 240/ 415 volts, 50Hz, 10KA "G" series, miniature circuit breaker (suitable for motor and other inductive loads and conforming to IS 8828: 1996, IEC 60898: 2002) of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Note: ISI marked MCBs of Havells / Loadster / Indo Kopp make shall be used.
247Double pole
248Four pole
249FOUR POLE RCCB Supplying and fixing following rating, four pole, (three phase and neutral) 415 volts, residual current circuit breaker (RCCB), ISI marked, having a sensitivity current upto indicated milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. Note: ISI marked RCCB shall be used.
25040 amps., 30 mA
25140 amps, 100 mA
25263 amps., 30 mA
25363 amps, 100 mA
254BARE STRANDED COPPER FLEXIBLE EARTHING: EARTHING WITH BARE STRANDED COPPER FLEXIBLE CONDUCTOR Earthing with bare stranded tinned copper flexible conductor including providing and connecting equipments with earth busbar, supply and fixing of copper stranded wire of following sizes and making connection with equipment by means of GI bolts, nuts, washers, copper lugs etc. all complete with labour and materials as per direction of Engineer-in-Charge.
25516 sqmm
25625 SQ. MM
257SUPPLYING AND FIXING CEILING FAN: Supply,installation,testingandcommissioningofceilingfansofBajaj/CromptonGreaves/Khaitan/Ushamakeonlyincludingsupplyandfixingoftheelectronicregulatorswithallnecessarysupports.Allcompletewithlabourandmaterialsasperdrawings,specificationsanddirectionsofEngineer-in-Charge.
2581200 MM SWEEP (WHITE)
259SUPPLYING AND FIXING FRESH AIR/EXHAUST FAN: Supply,installation,testing and commissioning of singlephase, Fresh AirFans /Heavyduty ExhaustFans of Bajaj/CromptonGreaves/Khaitan/UshamakeonlyincludingsupplyandfixingwithallnecessarysupportsAllcompletewithlabourandmaterialsasperdrawings,specificationsanddirectionsofEngineer-in-Charge..NOTE:Necessarycivilworksrequiredforfixingtheexhaustfansshall be in the scope of Contractor.
260FRESH AIR FAN WITH LOUVER SHUTTER 300MM SWEEP
261FRESH AIR FAN WITH LOUVER SHUTTER 400MM SWEEP
262Supply, installation, testing and commissioning of Wall Mounted Fans of Bajaj/Crompton Greaves/Khaitan/Usha make only including supply and fixing of the electronic regulators with all necessary supports. All complete with labour and materials as per drawings, specifications and directions of Engineer-in-Charge.NOTE: Necessary civil works required for fixing the exhaust fans shall be in the scope of Contractor.
263OSC. WALL & CABIN FANS OF 300MM SWEEP
264OSC. WALL & CABIN FANS OF 450 MM SWEEP
265Supply, installation, connection, testing and commissioning of the following post top lantern lighting fixtures of Philips/ approved equivalent make suitable for different lighting poles and laying, connecting 4x4 sqmm Al. unarmoured cable from marshalling box to fitting through pole complete with lamps (lamps cost will be paid separately) and necessary control gear including supply of all wires, clamps, supports, etc. all complete with labour and materials as per drawings, specifications and directions of Engineer-in-Charge..
266Type HPS 360/125 W HPL-N Sonora Post Top decorative luminaire
267Type HPC 101,102,104,106/125 W HPL-N Post top lantern with conical / elliptical / ribbed conical / spherical cover
268SUPPLY & installation OF LAMPSSupplyofbelowgivenM/sPhilipsorequivalentmake lampsforinstallationinlightingfittings/fixturesasper directions of EIC.
269LED Bulb 5-6W
270LED Bulb 9W
271LED tubelight 18W
272REWINDING OF MOTORS: Rewinding of 1-phase/3-phase electrical motors of various voltage grades/makes/types and of following capacities as per the original specifications & types/gauge ofrewinding/windingwire,insulationofvariouspoints insideslots/overhangandoverallfinallayersof insulation/tapesaspertheoriginalmotorspecifications, after baking to required temperature and applying insulating varnish (Dr-Beck & Co. make & type), providing glass/othertypesofsleavesonconnectionwiresfrom insidemotorwindingtoconnectionplate. Thewinding, varnishing, tapes and other materials required for completion of this complete job is in the scope of contractorexcludingtransportationto&fromOwner’s works to Contractor"s rewinding shop.which shall be paid seperatelyontripbasis.ThewindingwirewillbeDevi Dayal make and insulation tapes shall be ISI marked & of reputedmanufacturersasperdecisionofEngineer-in- Charge. Thisalsoincludesrepair/replacementof connectionplatecompletelyincludinginsulatingsheet, nuts, bolts, washers and other hardwares as per original specifications.Thisfurtherincludesreplacementofbearings(DE& NDE) of SKF make & greasing (IOC/HP make Servogem 2 or equivalent).This further includes satisfactory trial of motors at Owner’s premises at No load as well as at Full load.The Contractor will guarantee the rewound motors for satisfactory performance for a period of minimum six months at owner’s premises & if any such rewound motor failswithinsixmonths,itistoberewoundagainby Contractorfreeofcost. Allcompletewithlabourand materialsasperdirectionsofEngineer-in-Charge.Note: Burntwinding wireshallbekeptby Contractor. Bearing Shall be supplied by IOCL
273Motors above 7.5 KW but upto including 11 KW
274COPPER WIRING IN EXISTING CONDUIT / CASING CAPING Supplying and drawing following size of PVC insulated, copper conductor, single core cable in the existing surface / recessed, PVC/ steel conduit / PVC casing and capping as required. Note: Only ISI marked cables shall be used.
2751 X 1.5 SQMM
2763 X 1.5 SQMM
2773 X 2.5 SQMM
278MONTHLY ROUTINE MAINTENANCE OF WINDOW AC,SPLIT AC, WATER COOLERS ETC.Routine, regular and breachdownmaintenanceofWAC,SAC,WCandcoldstorageofdifferentmake&differentcapacities.Installedatvariouslocationofrefinerypremises,refinerytownship&airmonitoringstation.Jobincludesattendingthecomplaintsofmachinesasperthecomplaintregisterandinstructionofsiteengineer.Jobincludescheckingofmachines,identificationofdefect,repair/replacementofdefectivecomponent.Rewindingofblowermotor.ReplacementofThermostat,Blower,Fanblade,electricalswitches,controlknob,wires.Cleachningofairfilter,removalofdustfromcoolingcoil&condenserbyremovingthemachinefromlocationifrequired.Attendingtheminor/majorleakageofrefrigerantgasR-22/R-12arresting the leak and recharging the as.Repair/replacementofdefectivebush/bearingofblowermotorincludinglubricationofblowermotor,tighteningofalltheelectricalconnection.Repair/Replacement(byrepairedcompressor)ofdefectivecompressor.Jobincludesdismantlingofdefectivecompressoreitheratsiteoratworkshopaftertransportationofmachinetoworkshop,taking necessary gate pass/permission from concerned
279REMOTE CONTROL SWITCH FOR SPLIT AC: Supply&fixingofremotecontrolswitchpendanttypefortemperaturecontrollingoftheVoltas/Amtrex/FeddersLloyds/CarrierAirconoranyothermake,splitairconditionersof2.0/3.0(2x1.5TR)TRcapacity.Jobincludesdismantlingofthedefectiveswitchesandwireandinstallationofnewswitch.JobcompleteinallrespectincludingmanandmaterialandasperthedirectionsofEngineer-in-Charge.
280Dismantling & shifting of Split Air Conditioning Unit 1.0TR / 1.5TR / 2.0TR capacity including indoor and outdoor unit, refrigerant tubing etc. complete to new location or A/C workshop as per direction of Engineer-in-charge.
281Installation of split type wall Mounted Air Conditioner indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A/R22/Other, including connection of copper pipe and material supplied with complete unit etc. as required (Excluding cost of copper pipe) within Refinery / Petrochemical Complex/ Refinery Township as per direction of Engineer-in-charge.
282ADDITIONAL COPPER TUBE FOR SPLIT AC: Supply & fixing of additional length of copper tube for split A/C commissioning including all accessories
283REPLACEMENT OF BURNT UNCUT COMPRESSOR: Replacement of burnt uncut compressor of 1.5-ton capacity from the manufacturer whenever required as per direction of engineer-in-charge.
284Gas charging of air conditioner upto 1.5ton capacity with job involved transportation of machine to vendors" works. Checking of all components for leak by charging co2 gas & finally evacuating the compressor completely & charges of refrigerant gas - 22. A
285Measurement of earthing resistance in the refinery including transportation of earthing electrodes, cables etc. from stores to site, drawing the same into the ground at different points for measuring the earth resistance. The job includes the supply of connecting leads, clamps etc. All complete with labour and materials as per drawings, specifications and directions of the Engineer-in-Charge. NOTE Measuring instruments to be supplied by the Owner.
286CEL03114XXSupplyoffollowingratingandbreakingcapacity 4pole MCCBwiththermomagneticreleasealongwithterminal spreaders as per direction of Engineer-in-Charge.
287100 Amps, 30kA
288125 Amps, 36kA
289Cleaning of complete PCC/MCC panels. It includes opening of side top covers, removal of dust by vacuum cleaners/blowers etc., checking and tightening of screws, nuts, bolts, washers & connections, application of petroleum jelly and boxing up of the panels. All complete with labour and materials as per directions of the Engineer-in-Charge.
290CLEANING OF CABLE TRENCHES Cleaningofcabletrenchesofdepthupto3meterand width 1.5 meter of cable galleries, sub stations and other locationsetc. ThejobincludesliftingofRCC slabs/Chequerredplates,removingofpaperwastejute, mud, or any other unwanted materials lying in trenches & dumping these waste materials in the nearest dust bin or asdirectedbytheEngineer-in-Charge.,keepingback RCCslabs/chequerredplatesinpositions. Allcomplete with men and materials as per direction of the Engineer-in Charge.
291HT PANEL CLEANINGCleaning of HT Bus panel (Each breaker panel). It includes opening of top cover, removal of dust by vaccum cleaning/ blower etc. Checking & tightening of connections, cleaning of insulator, application of petroleum jelly and boxing up of the Bus bars/panels. All cleaning materials such as cotton waste, Markin cloth etc. shall be supplied by the contractor. All complete with men, materials and equipments like tools & tackles as per direction and satisfaction of the Engineer-in- Charge.
292TRANSFORMER CLEANING: Cleaningoftransformerincludessurfacecleaningi.e. cleaning of accumulated sticky oil and other dust, oil fins. JobincludesopeningofLTduct&HTterminalbox, cleaningofductandterminalbox,tighteningofnuts& bolts wherever is required.Job to be completed with all men,materialsandequipmentsliketools& tacklesas perdirectionandsatisfactionoftheEngineer-in-Charge. All cleaning materials such as markin cloth, cotton waste etc. shall be supplied by the Contractor.
293Filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength as per pacification given below (excluding the supply of oil. a) Filtration of transformer oil till desired bdv is attained as per is. b) Topping up of oil. c) Releasing all the air from air release plug & bucholz relay. d) To and fro transportation of filter machine and equipments.
294Supplying and erection of galvanised stay set for 11 KV overhead line complete with 19/20mm. dia. X 1.8 metres long stay rod, anchor plate of size 45 cm x 45 cm x 7.5 mm thick, thimble, stay clamps, turn buckle (20mm x 600mm), 7/4.00mm dia. G.I. stay wire and 11 KV strain insulator etc. in cement concrete 136 (1 cement 3 coarse sand 6 graded stone aggregate 40mm. nominal size) foundation including excavation and refilling etc. as required.
295350W LED Flood lights IP65 for High Mast
296150W LED Flood lights IP65
29745W LED street Light
298Lifting of submersible pump set fallen inside the bore, including the lifting of handing pipes, with supply of all tools and tackles etc. carrying out the work within 48 hours of information.
299Pest control Services
300Disinfection control:Providing anti malaria spray (Adulticide) in complete IOCL Korba Residential Colony including D Type Blocks, C Type Blocks, B Type Blocks, Bachelor Hostel Blocks, Transit Camp, Community Centre, Sub Station, Security Room, Gardens, Drains, etc for eradication of Cockroaches, Bed Bugs, Blisters, Worms, Black/ Red Ants & other harmful pests by Spraying pesticides/ insecticides(mixed with water) like Cypermethrin/ Malathion or any other approved Pesticide once in a month including cost of all materials, machinery, Labour & any other item required to complete the job as per direction of Engineer in Charge.
301Rodent control: Providing rodent control services by placing trapping devices like glue mats etc followed by baiting. Approved Rodenticide in cake form to be provided in the cable trenches/ Rooms etc for control of rodents and direct treatment of rodent burrows with rodenticide wherever feasible at IOCL Korba Residential Colony including D Type Blocks, C Type Blocks, B Type Blocks, Bachelor Hostel Blocks, Transit Camp, Community Centre, Sub Station, Security Room, Gardens, Drains, etcand other area within premisesas per tender terms and conditions.
302Reptiles control:Supply, mixing and application of pesticides for lizards & snake control treatment at IOCL Korba Residential Colony including D Type Blocks, C Type Blocks, B Type Blocks, Bachelor Hostel Blocks, Transit Camp, Community Centre, Sub Station, Security Room, Gardens, Drains, etc and other area within premisesas per tender terms and conditions.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail