| 1 | O.T.-5 |
| 2 | Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit Concealed in wall with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit including Modular type M.S. Box, Modular type 5/6 Amp.switch, ceiling rose/ angle/ batten holder complete in all respect, as directed including matching colour wash. [P.S. No. 131C + 187 A] |
| 3 | Wiring point for Plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit Concealed in wall with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit including Modular type M.S. Box , Modular type 5/6 Amp.switch, complete in all respect, as directed including matching colour wash. [P.S. No. 134C + 187C] |
| 4 | Wiring point for Fan/ Fresh Air Fan with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit Concealed in wall with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit including Modular type M.S. Box , Modular type 5/6 Amp.switch, ceiling rose etc. complete in all respect, as directed including matching colour wash. [P.S. No. 133C + 187A] |
| 5 | S&F of 6 Amp. to 32 Amp. DP MCB (10 KA) C Curve with sheet steel enclosure for S.P/ D.P. MCB with neutral link and earth terminal. CAT-A. [P.S. No. 1009+1032] |
| 6 | S&F of 6 Amp. to 32 Amp. DP MCB (10 KA) C Curve [P.S. No. 1009] |
| 7 | Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of work. [P.S. No. 1139(A)] |
| 8 | Supply and fixing of electronic fan regulator( Modular) 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work [P.S. No. 1203(C)] |
| 9 | S&F of 125 Amp 4 pole MCCB (25 KA) Thermal Magnetic release. CAT A [P.S. No. 1021 (D)] |
| 10 | S & F surface/Flush mounting 12 ways SPN distribution board with additional metal door without MCB complete in all respect, as Direct by Engineer in Charge. CAT A [P.S. No. 1025 A] |
| 11 | S & F surface/Flush mounting 4ways V TPN distribution board with additional Door without DPX3 160 MCCB complete in all respect, as directed at site by Engineer in charge. CAT A [P.S. No. 1030(A)] |
| 12 | S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve CAT A [P.S. No. 1002] |
| 13 | Supply and laying of 50 Sq. mm 3½ Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. [P.S. No. 501(i) ] |
| 14 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. for 50 sq. mm 3-1/2 core [P.S. No. 503(i)] |
| 15 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge.for 50 sq. mm [P.S. No. 504(g)] |
| 16 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge.- for 25 sq. mm [P.S. No. 504(e)] |
| 17 | Supply and wiring of submain with two number 6 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable iin 25 mm dia heavy duty (2 mm thick) PVC conduit on surface with one No. 4 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth contuiity wire drawn in conduit including matching colour wash etc., complete in all respect. [P.S. No. 212(C) ] |
| 18 | Supply and wiring of submain with two number 4 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable iin 25 mm dia heavy duty (2 mm thick) PVC conduit Concealed in wall with one No. 2.5 sq. mm FRLSH PVC insulated multistrand copper conductor cable as earth contuiity wire drawn in conduit including matching colour wash etc., complete in all respect. [P.S. No. 216(C) ] |
| 19 | Supply and wiring of submain with two number 2.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable iin 20 mm dia heavy duty (2 mm thick) PVC conduit Concealed in wall with one No. 1.5 sq. mm FRLSH PVC insulated multistrand copper conductor cable as earth contuiity wire drawn in conduit including matching colour wash etc., complete in all respect. [P.S. No. 1304(C) ] |
| 20 | Supply of Ceiling Fans with fan motor of A.C. Permanent insulation, capacitor rating conforming BEE-5 Star rating and IS:374/79 and also comply with IS:1709/1984 with least amendent. The rated voltage 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. BEE 5 star rated - 1200mm. sweep. [P.S. No. 1501(i)] |
| 21 | Erection and testing of ceiling fan and regulator etc. excluding supply of down rod, complete in all respect. [P.S. No. 1115] |
| 22 | S/F of 16 Guage M.S. Drum duly painted including making hole in the wall for exhaust fan complete in all respect. [P.S. No. 1122] |
| 23 | Supply and fixing of LED Tube Light with Metal Heavy Duty Box type batten light fitting 1X22W suitable for 1X22W LED Polycarbonate tube light complete including tube suitable for both surface & suspended complete in all respect. CAT-AAA. 2420 system lumens, 1101m/W, PF>0.95, THD<10%, CRI>80, sheet thickness 0.8mm., Tube with Aluminium heat with 5 year warrantee. [P.S. No. 1413] |
| 24 | Trauma Center |
| 25 | Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. for 400 sq.mm.3.5 core.[P.S. No. 501(T)-507] |
| 26 | Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. for 400 sq.mm.3.5 core.[P.S. No. 501(T)] |
| 27 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-in-charge. for 400 sq. mm 3-1/2 core [P.S. No. 503 T] |
| 28 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. for 400 sq. mm [P.S. No. 504 (O)] |
| 29 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-In-charge. for 185 sq. mm [P.S. No. 504 (L)] |
| 30 | S&F of 630 AMP four pole mouled case type on load change over switch with enclosure including the cost of labour, T & P and material reuired for proper completion of the work as per direction and satisfaction of Engineer-in-charge. [P.S. No. 383(A)] |
| 31 | Supplying and laying of 120 mm dia (OD-120 mm & ID-103 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. [P.S. No. A/R] |