Tender For Construction Of Deficient Otm Accn At Bharatpur Mil Station; Lump Sum Price Worked Out By The Contractor For Building WorksAs Listed In Schedule ‘A’ Part-I Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Price Prepriced By The Mes 2 Lump Sum Price Worked Out By The Contractor For Internal Water Supply Works As Listed In Schedule ‘A’ Part-Ii Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 3 Lump Sum Price Worked Out By The Contractor For Internal Electrification WorksAs Listed In Schedule ‘A’ Part-Iii Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 4 Lump Sum Price Worked Out By The Contractor For Road, Path & CulvertAs Listed In Schedule ‘A’ Part-Iv Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 5 Lump Sum Price Worked Out By The Contractor For Sewage Disposal As Listed In Schedule ‘A’ Part-V Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 6 Lump Sum Price Worked Out By The Contractor For Area DrainageAs Listed In Schedule ‘A’ Part-Vi Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 7 Lump Sum Price Worked Out By The Contractor For External Water SupplyAs Listed In Schedule ‘A’ Part-Vii Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceof Prepriced By The Mes 8 Lump Sum Price Worked Out By The Contractor For External Electrification As Listed In Schedule ‘A’ Part-Viii Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceof Prepriced By The Mes 9 Lump Sum Price Worked Out By The Contractor For Solar Water Heater, Summer Appliances & Solar Power Generation Etc.As Listed In Schedule ‘A’ Part-Ix Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 10 Lump Sum Price Worked Out By The Contractor For Refuse Bin Etc.As Listed In Schedule ‘A’ Part-X Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 11 Lump Sum Price Worked Out By The Contractor For Site Clearance, Site Development & Earth Worketc.As Listed In Schedule ‘A’ Part-Xi Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 12 Lump Sum Price Worked Out By The Contractor For Demolition Worketc.As Listed In Schedule ‘A’ Part-Xii Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes 13 Sch A Sec-Xiii: Miscellaneous Itemsnotes: ( I ) This Schedule Is Not Pre-Priced By Mes And The Pre-Priced Rate Indicated As Rs 0.00 Under Column 5 Signifies This Fact Only. ( Ii ) Excavation And Earth Work Except For The Items Which Categorically Includes For Same Shall Be Measured And Paid Separately Under Sch A Part-Xi ( Site Clearance, Site Development & Earth Work Schedule ) . 14 Internal Electrification . 15 M&L For Point Wiring With 1100 Volts Grade Pvc Insulated Multistranded Copper Frls Single Core Pvc Insulated And Unsheathedi Multistranded Copper Conductore And Inci Pvc Rigid Non Metallic Concealed Conduit Of Size 20 / 25 Mm Dia Medium Duty, Isi Marked To Be Terminated In Pressed Steel Terminal Boxes With 3Mm Thick Bakelite Sheet Top Cover Incl 1.5 Sqmm ( 22 / .3Mm ) Pvc Insulated And Unsheathed Frls Single Core Multistaned Copper Earth Continuity Conductor For One Light Point Controlled By One, One Way Switch, Completeall As Specified & Directed By Engr-In-Charge. 16 All As Per Description Of Serial Item No. 14.01 Above But For One Fan Point Controlled By One, One Way Switch. 17 All As Per Description Of Serial Item No. 14.01 Above But For One Three Pin 5 Amp Socket Outlet Point On Independent Board. 18 All As Per Description Of Serial Item No. 14.01 Above But For One Three Pin 5 Amp Socket Outlet Point On Same Board. 19 All As Per Description Of Serial Item No. 14.01 Above But Point Wiring With 2.5 Sqmm Single Core Frls Cable And Earth Continuity Wire 2.5 Sqmm Single Core Cable For One 3 Pin, 15 Amps Socket Outlet Point, Controlled By One, One Way Switch. 20 All As Per Description Of Serial Item No. 14.01 Above But For One Light Point Controlled By Two Nos, 2 Way Switch. 21 S & F For Highly Efficient Led Bulbs, 9 Watts Complete All As Specified And Directed. 22 S&F Sheet Metal Enclosure Distribution Board Vtpn, 6 Way, 415 Volt, Double Door Powder Coated, Protection Class Ip-54, Isolated Neutral Bar, Mechanical Impact Strength Ik 09 Suitable For Mounting Mcb & / Mccb Dbs Confirming To Is-13032, Is-8632, Bs5484 With Min 200 Amp Raiting Copper Bus Bar And Grouting, Fixing On Wall With Nut Bolts Washers Proper With Pcc Works Complete All As Specified And Directed. 23 S&F Sheet Metal Enclosure Distribution Board Vtpn 4 Way, 415 Volt, Double Door Powder Coated, Protection Class Ip-54, Isolated Neutral Bar, Mechanical Impact Strength Ik 09 Suitable For Mounting Mcb & / Mccb Dbs Confirming To Is-13032, Is-8632, Bs5484 With Min 200 Amp Raiting Copper Bus Bar And Grouting, Fixing On Wall With Nut Bolts Wasshers Proper With Pcc Works Complete All As Specified And Directed. 24 M&L For Concealed Submain Wiring Withpvc Insulated Frls Multistranded Copper Conductor Cable Of Size 3X6.0 Sqmm Drawing Into And Includingrigid Non Metallic Pvc Conduit, Medium Grade Not Less Than 25 Mm Dia Isi Marked Ivory Colour With All Conduit Fittings And Fixing Accessories And 1X4.0 Sqmm Frls Multistranded Copper Conductor Cable As Continuous Earth Wire Complete & Including Cutting, Chasing & Good To Finished Surface For Concealed Wiring, Completeall As Specified And Directed By Engineer-In-Charge. 25 All As Per Description Of Serial Item No. 14.10 Above But With Cable Of Size 2X10.0 Sqmm & 1X10 Sqmm Earth Wire With Appropriate Size Of Pvc Conduit. 26 All As Per Description Of Serial Item No. 14.10 Above But With Cable Of Size 4X10.0 Sqmm & 1X6 Sqmm Earth Wire With Appropriate Size Of Pvc Conduit. 27 All As Per Description Of Serial Item No. 14.10 Above But With Cable Of Size 2X4.0 Sqmm & 1X4.0 Sqmm Earth Wire With Appropriate Size Of Pvc Conduit . 28 Sewage Disposal 29 M&L For Providing, Laying, Testing And Commissioning Of 150Mm Bore Double Wall Corrugated Pipe ( Remarks Dwc ) Pipes Of Sn-8 Grade For Sewer Line As Per Is-14333, 16098 ( Parts ) :3013 Below Ground At Requred Depth Including All Jointing Fixtures Carriage, Barricading, Lighting Arrangment, Cutting Of Any Type Road Etc., Complete All As Specified &Directed By Engr-In-Charge.. 30 M&L For Construction Of Septic Tank For 100 User , Exccvation In Any Type Of Soil, Foundation In Pcc 1:4:8, Brick Work In Cm 1:4, Rccslab Covers Incl Rcc Precast Manhole Cover Having 6 Mm Plate Embeded All Around / Fibre Reinforced Cover With Angle Iron Frame, Vent Shaft And Sludge Chamber Etc, Complete, All As Specified & Shown In Drawing. 31 M&L For Construction Of Soakage Wells 2.40M Dia And 3.00 M Effective Depth Soakage Wells, Excavation, In Any Type Soil, Fdn In Pcc 1:3:6, Walls Of Honey Combed Masnory With Top Ring Of M-25 Concrete Including Intercepting Chamber And Screen Chamber Made Of Brick Masnory In Cm, Rcc Cover Slab In M-25 / Sfrc Cover, Interconnecting Pipes Of Rcc / Dwc Complete Filled With Brick Bats, Complete, All As Specified & Shown On Drgs. 32 External Water Supply. 33 Boring Of Holes Under Road, Pavement, Hard Standing By Trenchless Technology Using Ultra Sounding Technique And Necessary Machine For Laying Under Ground Pipe Up 150Mm Dia Completenote :- Di / Gi Pipe Shall Be Measured And Paid Separately Under Respective Item. 34 Supplying, Laying, Jointing Incl Rubber Gasket Joints, Testing And Commmisioning Of Di Pipe As Per Is 8329, Class K-7, 100Mm Bore With Inside Cement Mortar Lining With Spigot And Socket Ends Laid In Trenches Complete All As Specified And As Directed. 35 S&F Ms Flange Of Size100mm Bore Not Less Than 16Mm Thick Duly Welded On Ends Of Ms Pipe, Complete All As Specified And Directed. 36 M&L For Ci Fittings / Specials Such As Tees, Bends ( Any Type, Radius And Angle ) Tapers Any Type, Collars, Tail Pieces, Caps And Plugs Up To 250 Mm Bore Confirming To Is: 1538-1993 Complete All As Specified And Directed By Engineer- In -Charge. 37 M&L For Di Fittings / Specials Such As Tees, Bends ( Any Type, Radius And Angle ) Tapers Any Type, Collars, Tail Pieces, Caps And Plugs Up To 250 Mm Bore Confirming To Is: 1538-1993 Complete All As Specified And Directed By Engineer-In-Charge. 38 M & L For Construction Of Valve Chamber And Brick Masanary In Cm 1:6 Of Size 90Cm X 90Cm X 100Cm ( Internal Dinentions ) With 15Cm Thick Pcc Foundation In Pcc 1:4:8 Type D2 Using ( 40Mm Graded Stone Agreegate ) 15Mm Thick Plaster In Cm 1:6, 3Mm Thick Ms Sheet Cover Including 40 X 40 X 6Mm Ms Angle Iron Frame Fixed In Pcc Coping, Using Pcc 1:2:4 Type B1 ( Using 20Mm Graded Stone Agreegate ) With Necessary Locking Arrangement And Pointed With Two Coats Of Synthetic Enamel Paint Over A Coat Of Redoxide Primer On All Exposed Surfaces Including Necessary Excavation And Earth Work In Any Type Soil, Returning And Filling In And Ramming And Removal Of Surplus Soil Upto A Distance Not Exc 50 Mtr. 39 External Electrification . 40 Boring Of Holes Under Road, Pavement, Hard Standing By Trenchless Technology Using Ultra Sounding Technique And Necessary Machine For Laying Under Ground Pipe Up 150Mm Dia Completenote :- Gi Pipe Shall Be Measured And Paid Separately Under Respective Item. 41 Supply, Laying And Testing Cable Xlpe Insulated , Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Copper Conductor Single Core Of 120 Sqmm, Complete, All As Directed. 42 Supply, Installation, Testing & Commissioningfactory Madelt Feeder Pillar Box, Out Door Type With Ip 56 Protection ( Including Cpri Type Test Certified Manufacturer ) Design As Per Is / Iec : 61439-1 :2011 & 6143-2:2011, Platform Mounted Suitable For 415 Volt , 3 Phases, 4 Wire , 50 Hz, Acsupply System All As Specified And Directed Having Busbar Chamber With Insulated Copper Bus Bars 400 Amps Rating Installed On Percelain Insulators, The Panel Shall Be Dust And Vermin Proof Double Door Made Of 3.15 Mm Crca Ms Sheet Outer & 2.0Mm Thick Inner And Individual Compartment For Mccb / Mcb & Volt / Ampsmeter.The Complete Feeder Pillar Box Should Be Powder Coated Including Connections Between Main Bus Bar To Outgoing Mccb / Mcb Shall Be Carried Out By Copper Busbar 63Amps And Above Mccb & Below 63 Amps By 16 Sqmm Copper Cable. Front Opening Type With Approx For Cable Entry With Double Door Shutter Including Locking Arrangement As Per Manufacturers With 2 Keys, Complete, All As Specified & Directed.. 43 Incoming ( A ) Mccb 4 Pole, 415 V, Thermal Magnetic Release, Adjustable Type, 250 Ampswith 35 Ka Rapturing Capacity -01 No. ( B ) Bus Bar Copper400 Amps- 01 Set Of 4 ( C ) Digital Voltmeter With Selector Switch -01 No. ( D ) Digital Ammeter With Cts, With Selector Switch - 01 No. ( E ) Indicator Lampfor Three Phase And Seletor Switch Complete As Requiredout Going- ( A ) Mccb 4 Pole, 415 V, Thermal Magnetic Release, Adjustable Type, 100 Amps With 25 Ka Rapturing Capacity -02 No. ( B ) Mccb 4 Pole, 415 V, Thermal Magnetic Release, Adjustable Type, 63Amp, With 25 Ka Rapturing Capacity-03 No ( C ) Mcb Spn40 Amps, 240 Volt, Category- C Curve, 10Ka Rapturing Capacity-04 Nos 44 Note: ( I ) Drawings& Design Of Lt Panel Shall Be Got Approved By Ge Before Manufacture. ( Ii ) Panel Stand Shall Be Made Out Of 50X50x5mm Isa Angle Of 60Cm Height And Appropriate Size As Per Panel. The Same Should Be Fixed In Pcc Below Ground Level 15Cm And Above Ground Level 10Cm. 45 Supply, Installatio, Testing & Commissioningfactory Made, Lt Feeder Pillar Box Out Door Type With Ip 56 Protection ( Including Cpri Type Test Certified Manufacturer ) Design As Per Is / Iec : 61439-1 :2011 & 6143-2:2011, Platform Mounted Suitable For 415 Volt , 3 Phases, 4 Wire , 50 Hz Acsupply System All As Specified And Directed Having Busbar Chamber With Insulated Copper Bus Bars 400 Amps Rating Installed On Percelain Insulators, The Panel Shall Be Dust And Vermin Proof Double Door Made Of 3.15 Mm Crca Ms Sheet Outer & 2.0Mm Thk Inner And Individual Compartment For Mccb / Mcb & Volt / Ampsmeter.The Complete Feeder Pillar Box Should Be Powder Coated Including Connections Between Main Bus Bar To Outgoing Mccb / Mcb Shall Be Carried Out By Copper Busbar 63 Amps And Above Mccb & Below 63 Amps By 16 Sqmm Copper Cable. Front Opening Type With Approx For Cable Entry With Double Door Shutter Including Locking Arrangement As Per Manufacturers With 2 Keys, Complete, All As Specified & Directed. 46 Incoming ( A ) Mccb 4 Pole, 415 V, Thermal Magnetic Release, Adjustable Type, 250 Ampswith 35 Ka Rapturing Capacity -01 No. ( B ) Bus Bar Copper400 Amps- 01 Set Of 4 ( C ) Digital Voltmeter With Selector Switch -01 No. ( D ) Digital Ammeter With Cts, With Selector Switch - 01 No. ( E ) Indicator Lampfor Three Phase And Seletor Switch Complete As Requiredout Going- ( A ) Mccb 4 Pole, 415 V, Thermal Magnetic Release, Adjustable Type, 63Amp, With 25Ka Rapturing Capacity-03 No ( B ) Mcb Spn40 Amps, 240 Volt, Category- C Curve, 10 Ka Rapturing Capacity-04 Nosnote: ( I ) Drawings& Design Of Lt Panel Shall Be Got Approved By Ge Before Manufacture. ( Ii ) Panel Stand Shall Be Made Out Of 50X50x5mm Isa Angle Of 60Cm Height And Appropriate Size As Per Panel. The Same Should Be Fixed In Pcc Below Ground Level 15Cm And Above Ground Level 10Cm 47 Supply, Installation, Testing And Commissioning Factory Made, Lt Feeder Pillar Box Out Door Typewith Ip 56 Protection ( Including Cpri Type Test Certified Manufacturer ) Design As Per Is / Iec : 61439-1 :2011 & 6143-2:2011, Platform Mounted Suitable For 415 Volt , 3 Phases, 4 Wire , 50 Hz Acsupply System All As Specified And Directed Having Busbar Chamber With Insulated Copper Bus Bars 400 Amps Rating Installed On Percelain Insulators, The Panel Shall Be Dust And Vermin Proof Double Door Made Of 3.15 Mm Crca Ms Sheet Outer & 2.0Mm Thk Inner And Individual Compartment For Mccb / Mcb & Volt / Ampsmeter.The Complete Feeder Pillar Box Should Be Powder Coated Including Connections Between Main Bus Bar To Outgoing Mccb / Mcb Shall Be Carried Out By Copper Busbar 63 Amps And Above Mccb & Below 63 Amps By 16 Sqmm Copper Cable. Front Opening Type With Approx For Cable Entry With Double Door Shutter Including Locking Arrangement As Per Manufacturers With 2 Keys, Complete, All As Specified & Directed. 48 Incoming ( A ) Mccb 4 Pole, 415 V, Thermal Magnetic Release, Adjustable Type, 250 Ampswith 35 Ka Rapturing Capacity -01 No. ( B ) Bus Bar Copper400 Amps- 01 Set Of 4 ( C ) Digital Voltmeter With Selector Switch -01 No. ( D ) Digital Ammeter With Cts, With Selector Switch - 01 No. ( E ) Indicator Lampfor Three Phase And Seletor Switch Complete As Requiredout Going- ( A ) Mccb 4 Pole, 415 V, Thermal Magnetic Release, Adjustable Type, 63Amp, With 25Ka Rapturing Capacity-03 No ( B ) Mcb Spn40 Amps, 240 Volt, Category- C Curve, 10 Ka Rapturing Capacity-04 Nosnote: ( I ) Drawings& Design Of Lt Panel Shall Be Got Approved By Ge Before Manufacture. ( Ii ) Panel Stand Shall Be Made Out Of 50X50x5mm Isa Angle Of 60Cm Height And Appropriate Size As Per Panel. The Same Should Be Fixed In Pcc Below Ground Level 15Cm And Above Ground Level 10Cm 49 Supply, Install, Commissioning And Testing Factory Made ( Including Cpri Type Test Certified Manufacturer ) Lt Panel Box ( Kiosk ) Out Door Type Platform Mounted Suitable For 415 Volt , 3 Phases, 4 Wire , 50 Hz Acsupply System All As Specified And Directed Having Busbar Chamber With Insulated Copper Bus Bars 600 Amps Rating Installed On Percelain Insulators, The Panel Shall Be Dust And Vermin Proof Double Door Made Of 3.15 Mm Crca Ms Sheet Outer & Inner And Individual Compartment For Mccb / Mcb & Volt / Ampsmeter.The Complete Feeder Pillar Box Should Be Power Coated Including Connections Between Main Bus Bar To Outgoing Mccb / Mcb Shall Be Carried Out By Copper Busbar 63Amps And Above Mccb & Below 63Amps By 16 Sqmm Copper Cable. Front Opening Type With Approx For Cable Entry With Double Door Shutter Including Locking Arrangement As Per Manufacturers With 2 Keys, Complete, All As Specified & Directed. 50 Incoming ( A ) Mccb 4 Pole, 415 V, Thermal Magnetic Release, Adjustable Type, 400 Amps With 35 / 36 Ka Rapturing Capacity-01 No. ( B ) Bus Bar Copper600 Amps- 01 Set Of 4 ( C ) Digital Voltmeter With Selector Switch -01 No. ( D ) Digital Ammeter With Cts, With Selector Switch - 01 No. ( E ) Indicator Lampfor Three Phase And Seletor Switch Complete As Requirednote: ( I ) Drawings Of Lt Panel Shall Be Got Approved By Ge Before Manufacture. ( Ii ) Panel Stand Shall Be Made Out Of 50X50x5mm Isa Angle Of 60Cm Height And Appropriate Size As Per Panel. The Same Should Be Fixed In Pcc Below Ground Level 15Cm And Above Ground Level 10Cm 51 S&F Factory Made Thermoplastic Cable Junction Boxes Ip 66 / 67 “Weather Proof”, With Terminals 3-Phase & Neutral For Outdoor Installation ( With Knockouts For Cable Entry ) Of Size 205 X 255 X 112 Mm Depth With Cable Entry Size Of 10-25 Sqmm 2 / 3.5 / 4 Core With Terminal. 52 S&F Street Light Gi Bracket Of 1.2 M Long Made Out Of 40Mm Dia Light Grade Gi Pipe Bend To Shape Of 120 Degree End Welded As Required Size Of Fitting Gallary Including 02 Nos Ms Clamp Of Fl 40 X 6Mm Including Nuts Bolts & Washers Complete Necessary Fixing Arrangements On Pole, All As Directed. 53 S&F Of Automatic Street Light Switch Using Infrared Sensor Based Nature Switch For Automatic Switching Of Street Lights. Nature Switch Operation Switch Operation Should Be Basedon Natural Light Lux Level. Required Illuminancelevel For Switching On Is<= 30 Lux Andfor Switching Off>=10 Lux. The Sensor Should Also Have Part Night Operation Facility Of Min 4 Hours To Max 12 Hours. The Sensor Along With Suitable Power Contactors, Incoming-Outgoing McbS And Auto Manual ( Sensor By-Pass ) Selection Option Should Be Enclosed In Apole / Wall Mountable Enclosure Made Of Rust Proof, Electric Shock Proof, Termite Proof And Fr Grade Smc Junction Box Conforming To Ip54. For Three Phase Load Of 5Kw ( Swadeep-02Ec5kw3p ) With: 3 Nos Contactors, 3 Nos Incoming McbS & 3 Nos Outgoing McbS Of 20-25 Amps Each & Circuit Wiring ( Copper ) Of Min 10 Sqmm.Make:Nature Switch:Kakatiya Energy System / Bajaj / Healer, Contactors:Bch / L&T / Sschneider, McbS: Hager / Schneider / L&T ( Exora / Au Series ) / C&S. 54 S&F Rubber Mat Of Size 1Mx2mx19mm Thick, All As Approved By The Ge. 55 S&Fms Ht / Lt Cable Route Indicatormade Out Of 80Mm Dia With 60Cm Long Ms Angle, Fi 25X6mm Complete And Painted With Two Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer, Duly Embossed Lt Voltage Including And Fix On Precast Pcc ( Pcc 1:2:4, Type B1 Using 20Mm Graded Stone Aggregate ) Block Of Size 30Cm X 20Cm X 60Cmin Coping Of Existing / New Poles / Foundation For Poles, Struts, Posts Etc Including Necessary Form Work, Finished The Exposed Surfaces Fair And Even Without Usingextra Cement Complete, All As Directed. 56 Solar Water Heater. 57 M & L For Iron Work With Ms Isa Angle, Ismc , Ms Sheet Of 3.15Mm Thick, Ms Flat, Ms Welded Mesh 25Mm Complete Incl Welding And Painted With Two Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer, Of Approved Colour All As Directed By Engr-In-Charge. 58 M&L For Monkey Guard Made Out Of Mild Steel Angle 40X40x6mm, Ms Flat 25X3mm And Ms Welded Mesh25mm For 500 Lite Water Tank Including Hinge 100Mm , Brick Work, Pcc Work And Plaster Work Complete All As Directed By Engr-In-Charge. 59 Summer Appliances 60 Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 100 V To 300 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 2.0 Kva. 61 Supply, Fixing And Fabrication And Testingdesert Cooler In Fibre Pvc Sheet With And Including Coolerfan Motor Size / Sweep 450Mm ( Fan Blade Only ) 230 Volts, Single Phase 50 Hz, 1400 Rpm, Heavy Duty Single Sheet, Totally Enclosed , Complete, All As Specified And Directed. 62 ( A ) Air Grill Of Suitable Size Made Out Of Pvc Sheet Including Gss Arrangement With A Knob For Easy And Smooth Movement. ( B ) Front & Side Panel Made Out Of Pvc Sheet Of Suitable Size And Shape. ( C ) Water Tank Of Suitable Storage Capacity ( D ) Submersible Pump Electric Driven Single Phase 230 Volts, 50 Hz Of Suitable Discharge And Head Butmotor Capacity Not Less Than 18 Watt. Make : Khaitan / Crompton Or Equivalent Make. ( E ) Service Cord Of 3 Core Copper Wire 1.5 Sqmm With Plug Top 5 Amp Length Not Less Than 2 Metres. ( F ) Electronic Fan Dimmer 1000 Watts Ac 230 Voltfor Controlling The Fan Speed. ( G ) Complete Electric Wiring Of Desert Coolers As Required To Operate Fan And Pump Along With 5 Amp Switches . ( H ) Make Of Cooler Fan Motor: Khaitan / Havells / Crompton Greaves / Marathon / Almonard 63 M&L For Making Desert Cooler Stand Made Out Of 40X40x5mm Isa Angle Iron Work Of Required Size Complete Paint With Two Coats Of Synthetic Enamelled Paint Over A Coat Of Zinc Chrome Primer Complete Including Grouting In Walls And Floor Wih Pcc B1 ( 1:2:4 ) All As Specified And Directed By Engr-In-Charge. 64 Solar Power Generation 65 Supply, Installation, Testing And Commissioning Of 30 Kwp Off-Grid Solar Roof Top Power Plant System Comprises Of Followings: 66 ( A ) Pv Modules: Qty-75 Nosmono Crystelline Solar Modules 400Wp ( Nominal ) , 72 Cells, Voc:49.9V, Isc:10.36A, Vmp:41.7V, Imp:9.60, Efficiency Not Less Than 20.0%, Tempered Glass Thickness 4.0Mm, Junction Box Ip65, 4T With 3 Diodes, Make: Axxon / Sunpower / Tata Bp Solar 67 ( B ) Off Grid Inverter- 01 Nos3 Phase Off Grid Solar Hybrid Inverter Of 30 Kw, 415V + / - 2%, 50 Hz Capacity, Having Two Separate Mpp Tracker ( 500-600V ) With Spd 1+2 With Class 1 &2 Surge Protection Devices Having Efficiency 98%, Graphical Displays+ Led, Interfaces With Ethernet.Usb, Rs485, So Output, Suitable For Ambient Temperature -20 To +60 Degree Centigrate, Protection Ip65, Fuse Protection Dc Input Plus And Minus, Overvoltage Protection Type 1+2, Night Consumption Not More Than 1.5Kw, With Lan Monitoring System. Make: Enertech / Fuji Electric / Speqta 68 ( C ) Battery:- 30 Noslow Maintenance Lead Acid Type 12V 200 Ah Battery. Make:- Exide / Luminous / Livefast 69 ( D ) Ajb - 01 Nossuitable Array Junction Box To Connect Strings Of Panels, Ip 65 Protection, 1000V Dc Spd Typeii, With Mc4 Connectors, Earhing Gland With Terminals Blocks. Makes For Internal Components:Hansel / Connectwell / Obo / Lumberg 70 ( E ) Acdb -01 Nossuitable Ac Distribution Box To Connect Input And Output, Ip 65 Protection, 1000V Ac Spd Typeii, Earhing Gland With Terminals Blocks.Makes For Internal Components:Hansel / Connectwell / Obo / Lumberg 71 ( F ) Structure -01 Setto Support The Pv Modules, Well Designed Non Metallic Grp Material Has To Be Used With Glass Content Min 60% Made With Special Polymeric Resin With Resistance To Saline Water, Air And Acidic Fumes, Expected Life Span:25 Yrs, Tensile Strength And Flexural Strength Should Not Reduce More Than 7% After 1000 Hrs Exposure To Accelerated Uv, Tensile Strength: Min 300N / Mm^2, Flexural Strength: Min 300 N / Mm^2, Compressive Strenght:Min 150N / Mm^2, Shear Strenght: Min: 20 N / Mm^2, Barcol Hardness Min 50, Specific Gravity:1.8-2.0 Designed To Handle Wind Speed Of 170Km / Hr, With Suitable Leak Proof Mounting Fastners And Ss Nut Bolts And Washers. Make: Axxon / Jml / Ma Engg 72 ( G ) Cables And Wires ( I ) 4Sqmm Weather Proof Dc Cable -01 Lot ( Ii ) 6 Sq Mm 4 Core Flexible Copper Cable -01 Lot ( Iii ) 16 Sqmm, Single Core Copper Flexible Cable -01 Lotmake: Polycal / Finolex / Havells ( H ) Integration Of Above System Mentioned In Item No ( A ) To ( G ) With Sucessful Testing Commissioning And Completion In All Respect With Satisfaction Of Engineer In Charge. 73 S&F Monkey Guard Pvc Spikes Having Angular Spikes, Translusent, Suitable To Tie In Gi Frame, Gi Pipes, Fixed On Wall Etc Around The Panles To The Full Length Of Perimeter , On The Border Post, Corner Structures Etcfor Each Pv Panel 400Wp All As Specified And As Directed By Engineer-In-Charge. 74 Arboriculture 75 S & F Rcc Tree Guard Of Size ( 1800X500x37 Mm -04 Pnnels ) With 5Mm Dia Reinforced Bar All As Specified And Directed By Engr-In-Charge. 76 Supply And Laying 20Mm Bore Steel Water Tubing, Medium Grade Galvanised With And Including Necessary Pipe Fittings / Accessories Like Sockets, Unions Tees, Elbows Etc And Laid In Trenches, Complete, All As Specified & Directed. 77 Supply &Planting Various Trees Well Growth ( Ht Of Tree Not Less Than 0.90 Mtr ) As Mentioned Below By Digging Pit Of Size 0.4 X 0.4 X 0.6 Mtr , Removing And Conveying Unwanted Material, Grass , Stones, Etc To A Distance Exc 500 Mtr, Providing & Flling Fresh Garden Soil & Farm House Manurein Excavated Pit In 2:1 Proportion, Mixing Garden Soil & Farm Manure Thoroughly To A Height Of 60 Cm, Well Leveling, Watering On Previous Height . Also Planting Two Years Growth Of Trees All As Specified And Approved And Maintaining Till Well Grown Up & Established By Watering , Weeding, Clipping, Rolling Etc To The Satisfaction Of Engr-In-Charge And Including Replanting Of The Dead Plants, All As Specified And Directed By Engr-In-Charge. 78 Ashoka 79 Gulmohar. 80 Real Palm 81 Neem 82 Jackfruit, Mango, Guava, Jamun Fruit Tree. 83 Amaltas-100 Nos, Shaddy Trees -100 Nos Note: For Ser Ltem No 21.03 To 21.09 ( I ) Height Of Plant Shall Be Measured From Top Of Foliage ( Not From The Isolated Branch / Leaf, Main Stem ) To 150Mm From Top Of Root. ( I ) Water Will Not Be Supplied By Mes. Contractor Has To Make His Own Arrangement For Watering To Plants. ( I ) The Rates Quoted By The Contractor Deemed To Be Included Forwatering, Maintenance Of Plants Till Two Years After Certified Date Of Completion Of Work. ( Iv ) . During Two Years After Completion Of The Work If Any Plant Is Found Dead, Or Not Of Satisfactory Growth, Plants Of Approved Size And Shape Shall Be Provided Without Any Extra Cost. ( V ) . Supply And Application Of Manure, Sweet Earth And Pesticides, Fertilizers, Etc Up To Two Years After Completion Are Deemed To Be Included In The Quoted Unit Rate. ( Vi ) Tenderer To Note That 10% Of Quoted Amount Against These Items Shall Be Retained For Two Years After Completion. In Case Of Failure By The Contactor To Maintain The Plants As Above, The Same Shall Be Carried Out By The Department At ContractorS Risk And Cost And The Expenditure Shall Be Deducted From This Retained Amount. ( Vii ) The Plants Shall Be Brought At Site Six Months Before The Date Of Completion Of The Work As Per Work Order