Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 09-11-2023 | Revised BOQ | Other | 20-11-2023 |
| Sl. No. | Item Description |
| 1 | CIVIL WORKRemoving chocks and leakages from down take GI/CI/PVC pipeline on walls floor level by using zoola / scaffolding and rectify the same for functioning with all lifts etc. complete. |
| 2 | Removal of plants /ficus grown by pulling out root system embedded in masonry, cutting stem and application of high/ gur/ lime formulation as specified by the Architect or other patented chemical biocide treatment such as biocide \"Glycel\" (iso proplamine salt of glyphosate) or other chemical as specified by the Engineer in charge etc. complete |
| 3 | Removing the tiles, battens and dungry cloth from roof, sorting out the serviceable and unserviceable materials and stacking the same as and where directed in the compound, scaffolding etc. complete. |
| 4 | Removing G.I. or A.C. sheet roofing including purlines, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete. |
| 5 | Specialised stone cleaning to remove oil or emulsion paint, stains or dark patches from surface of stone from old masonary of Heritage structure with paper pulp, chemicals, thinners, solvents, or soft Teepol or equivalant soap solvent/ solution or by using pressure jet machine with all the necessary care and precautions, etc. complete as directed by Engineer in charge.(As specified by Consulting Architect) |
| 6 | Removing damaged lightning arrestors, including conductor from their position, including fasteners and fittings, and stacking carefully etc. complete. |
| 7 | Removal of existing wooden veneer from doors carefully without damaging the original layer of a TW door and stacking the materials as directed with all leads lifts, etc.complete. |
| 8 | Removal of card boards/ timber pannels/ G.I sheets /asbesto sheets/ blockages of Arches, Windows and Doors carefully without damaging the plastered surface and stacking the materials as directed with all leads lifts,etc.complete. |
| 9 | Removal of M.S grills of Arches, Windows and Doors carefully without damaging the Historic surface and stacking the materials as directed with all leads lifts,etc.complete. - Arches in the service alley - G.F |
| 10 | Dismantling jack arch flooring and removing of Lime concrete in haunch filling ofjack arches. Checking of \"I\" sections for their structural integrity and removing the damaged sections at required height. Stacking and carting away the debris as directed with all leads and lifts, cleaningetc. complete. Appropriate measures and precautions to be takenwhile dismantling the floor that the external walls are not damaged structurally and as instructed by the consultant and Engineerin charge. |
| 11 | Removing R.S. girders of any size and span lowering the same and stacking neatly wherever directed in the compound scaffolding etc. complete. |
| 12 | Dismantling, lowering and numbering down existing stone members of historic structure, elements such as decorative rails, gothic style architectiral elements, railings, arch and vault stones, brackets, gargoyles, coping, pedestal, capital of stones etc.of any size and shape, in lime or cement including removing manually the wedged stone by light chiseling if required. lifting manually, lowering over sand bags, numbering the stones with enamel paint on the non visible surface, stacking the dismantled material in a proper storage within 50m radius as directed with all leads, lifts etc. complete. Item includes removing of lime mortar from dismantled stones and cleaning stones for reuse if required. As directed by the Consultant and Engineer in charge. |
| 13 | Proper dismantling of the damaged Terrace, including removal of Brick bat coba fixed on screed of 50mm thick lime mortar and resting on a lime concrete floor supported by MS \"T\" and ‘I‘ sections, stacking the serviceable materials in storage within 500m radius and carting away the rubbish as directed with all leads and lifts etc. complete. |
| 14 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, racking out joints, watering and scaffolding Complete. |
| 15 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts, complete. |
| 16 | Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads lifts, complete. Spec. : As directed by Engineer in charge. |
| 17 | Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts, complete. |
| 18 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts, complete.Ground floor |
| 19 | First floor |
| 20 | Secomd floor |
| 21 | Third floor |
| 22 | Removing W.C. Pan including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the service-able materials as and where directed including of throwing the unserviceable materials out side. |
| 23 | Removing the tar or coba and disposing of the material as directed etc. complete. |
| 24 | Removal of Timber flooring/ ceiling boards/ tiles taking care of the timberboards so that most of the removed planks can be reused. Item includes proper stacking of boards at a distance within 100 mts, sorting them in reusable and non reusable stacks, removing all old screws from the floor joists and disposing them in a safe place or as directed by Engineer or Architect in charge on site. |
| 25 | Removing wooden or A.C. partition including frame work and stacking the materials as with all leads, lifts, complete. |
| 26 | Removal of paint from Decorative stone surface carefully, without damaging the historic stone surface and ornamental work, manually, using pressure water jets and chemicals where needed, making the surface even and polished by hand scrapping tools, complete. |
| 27 | Scrapping the oldplasteredinternalsurface withsandpaperandcoatingthe entire surface with mixture of whiting or glue and linseed oil including scaffolding etc. complete as directed. |
| 28 | Removing the existing cement plaster of any thickness without causing dust nuisance and stack in g the debri s upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete. |
| 29 | Removing cementious pointing and other epoxy - based hard material from joints of Basalt stone manually with chisel and hammer or with the help of electric grinders. Proper care should be taken so that the stone is not damaged during removal. |
| 30 | Cleaning of Mettalic Stains or paint and rust of Iron railings and application of an anti rust coat to existing cast or wrought - iron fixtures. The paint can be removed by using oxypropane flame at a proper temperature without damaging the wrought iron surface, rust can be removed by wire brushing or applying a chemically neutral solution based on a combination of acid and alkali materials. Item also includes preparing the surface for paintings and coastings etc. complete |
| 31 | Removing ventilators and small windows with frame and stacking the materials with all leads lifts, complete.ground floor |
| 32 | first floor |
| 33 | second floor |
| 34 | Removing Manglore tiled roofand ridge tiles with battens, ridge and barge boards, eaves 8A board setcand sacking the materials as directed with allleads and lifts complete. Including removing wood work below etc. complete. |
| 35 | Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in superstructure including racking out joints when plastering is to be done / striking joints when no plastering is to be done watering and scaffolding complete. |
| 36 | Providing and fixing Ashlar Fine, Moderately carved stones of size 0.23 in height X 0.53 m wide 1st sort like coping/base/ cut stone, semi circular, champhered, semi octagonal, string courses, cap stones etc. in lime mortar 1:1.5 proportion; including lifting the dressed stones upto a height of 4.5-6.00 m., setting with stainless steel dowels, pins and fixing with Araldite and hardener, adding Bonding ingredients like Bel fruit (30Kg), Black Gur (jaggery)(20Kg) and other materials as per requirement against the quantity of lime mortar of 1.00 Cu.M including watering, curing and pointing etc. complete. The stones shall be dressed full or to template, or as shown in the working drawings. The exposed faces of the stone shall be fine chisel - dressed, and all joints shall be in line and close and not more than 3MM thick. All visible angles and edges to be free from unsightly chippings. as directed by Engineer in charge. |
| 37 | Consolidation of Friable Masonry,(these areas include ornate columns, pilasters, capitals whose decorative portions are succumbed to the heavy weather loading imposed on them) using Ethyl-silicate based consolidant applied manually with small brushes, low pressure spray(not atomised) held at work distance 50 to 100mm. preparing the surface, scaffolding etc. complete as directed. |
| 38 | Providing and fixing Ashlar Fine, Moderately or Heavily carved stones For Base stone Plinth stone (0.60 X 0.60 X 0.45) - 1st sort like columns, arch and vault stones, string /courses, cap stones etc. in lime mortar 1:1.5 proportion; including lifting the dressed stones upto a height of 4.5 - 6M., setting with stainless steel dowels, pins and fixing with Araldite and hardener, adding Bonding ingredients like Bel fruit (30Kg), Black Gur (jaggery) (20Kg). and other materials as per requirement against the quantity of lime mortar of 1.00 Cu.M including watering, curing and pointing etc. complete. The stones shall be dressed full or to template, or as shown in the working drawings. The exposed faces of the stone shall be fine chisel - dressed, and all joints shall be in line and close and not more than 3 mm thick. All visible angles and edges to be free from unsightly chippings, etc. complete. As directed by Architect consultant and Engineer in Charge. |
| 39 | Providing and fixing Mangalore tiled roofing with class \"AA\" tiles including securing the last course of tiles near the eaves with steel flat 40 mm x 3 mm and 1.22 mm wire fixing countryteak wood sloping battensof25 x12 mm teak wood horizontal battensof 50mm x25mm over the slopping battens, all iron work and coal tarring the battens etc. complete (Excluding ridge and hip tiles). |
| 40 | Providing and fixing Ghana teak wood common rafters, purlins and purlin cleats, hip rafters, jack rafters, ridges, wall plates, post plates and posts for roofing etc. including scaffolding, if necessary all iron work and one coat of primer complete. |
| 41 | Providing and fixing Indian teak wood framed collar beam / king post / queen post truss, withallIronworkincludingscaffolding,ifnecessary,andonecoatofprimeretc. complete. |
| 42 | Providing leak proof lead sheet flashing at the specified locations on the roof using 99.9%pure lead sheet of approved quality and company, having size 0.9 x 5.5m or more and thickness around 2.38mm but not less than 2mm bending in situ & joining end to end with 100m.m. lap (or as per detailed drawings and requirements for draining water from valley and eaves gutters in the historic building), with the help of gas welding. The top edge should be fixed by turning it 25mm in to a horizontal brickwork joint or groove in case of stone masonry, and also the upstand against wall should not be less than 100m.m. Fixing details should be referred from the detailed drawings, including screws and nails in stainless steel, after conformation with the Architect or Engineer in charge. Surface areas of lead sheet laid should be measured and no extras to be given for overlaps. |
| 43 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 44 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 45 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 46 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 47 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 48 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 49 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 50 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 51 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 52 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 53 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 54 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 55 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 56 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 57 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 58 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 59 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 60 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 61 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 62 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 63 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 64 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 65 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 66 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 67 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 68 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 69 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 70 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 71 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 72 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 73 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 74 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 75 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 76 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 77 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 78 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 79 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 80 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 81 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 82 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 83 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 84 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 85 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 86 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 87 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 88 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 89 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 90 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 91 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 92 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 93 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 94 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 95 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 96 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 97 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 98 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 99 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.Spec. No. : As directed by Engineer-in-charge. |
| 100 | Providing antitermite treatment to the joints of wooden beams or joint and woodenfalse ceiling used for the roof work of the existing building as per I.S. 6313 (Part-III) by drilling 6 mm dia. holes at a downward angle of about 45% at the junction of wood work and masonry and injecting 80 ml. of chlordane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee. Spec. No. : As directed by Engineer-in-charge. |
| 101 | Providing & fixing rough point chisel - dressed Khandaki paving (Minimum size of stone 0.45 x 0.30 x 0.18 M.) for Terraces or landing, as per design & detailed drawing & size, from approved source of & quality, including transportaion & conveyance to specific location, layingat a slope of 1 : 40 in line, level over layer of 20 mm. thick 1 : 1.5 lime mortar, with joints not exceeding 5 MM thick, specialadhesive material like araldite etc. with watering, curing, etc. complete. The sides of the stone are to be dressed true and square for 0.5\" for top, and the joints shall be set in lime for 1\"\" in from face. Including all material, lead, lift, tools, scaffolding, cleaning, washing, all taxes and including GST etc. complete. Specifications- As directed by Engineer In Charge. |
| 102 | Restoration of existing Old Windows of the Heritage structure providing, fixing and restoring all sorted old broken/missing etc, glazed window panels of historic structure which are original including removing of paint, sag corrections, manual finishing with removal of existing fittings, fixtures using epoxy/saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/damaged/dilapidated wooden membersand full qty of 5mm plain glass panels wherever required as per design including one coat of primer and two coats of melamine polish all the necessary fittings to be fixed at the location all inclusive as directed by Engineer in charge, etc, complete.Ground floor |
| 103 | first floor |
| 104 | second floor |
| 105 | Restoration of existing old Windows of the Heritage structure (main Building Windows) - Providing, fixing and restoring all sorted old broken/ missing etc. glazed window panels of historic structure which are original including, sag corrections, manual finishing with removal of existing fittings, fixtures, using epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/ damaged/ dilapidated wooden members (consider maximum 50% replacement of the total door size) and full qty. of 8 millimetreplain glass panels as per design, window panel is made of up 70 mm x 38 mm finished burma teak Wood frame with finished 40mm x 38mm center supports and dividers with 10mm BTC Lipping for fixing glass also 2 brass handles 6 brass butt hinges, 2 stays for windows and One \"9\" inches and one \"4\"inches long tower bolt,Including one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete. (window panel size 1.38 x 1.63)Ground floor |
| 106 | first floor |
| 107 | second floor |
| 108 | Restoration of existing old Louver Windows with New louver window For BTC Bottam of main Windows - providing, fixing and restoring all sorted old broken/ missing etc. Louver windows for ventilation of historic structure which are original including, sag corrections, manual finishing withusing epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/ damaged/ dilapidated wooden membersincluding finish frame size of BTC woodfinished 80x110 mm frame and Louvers of siuzeFinished 10 x 90mmincluding one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete.Ground floor |
| 109 | first floor |
| 110 | second floor |
| 111 | Third floor |
| 112 | Restoration of existing old Louver Windows For Bottam of main Windows - providing, fixing and restoring all sorted oldmissing Louver windows. Louver windows for ventilation of historic structure made up of BTC wooden members whichmanual finishing withusing epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, including finish frame size of BTC woodfinished 80x110 mm frame and Louvers of sizeFinished 10 x 90mm(consider maximum 50% replacement of BTC wood the total louver size)including one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete.Ground floor |
| 113 | first floor |
| 114 | second floor |
| 115 | Third floor |
| 116 | Restoration of existing old Windows /ventilators paneles with new BTC wood window ventilator. (windo type 1 ventilator window) - providing, fixing and restoring all sorted old broken/ missing etc. glazed window panels of historic structure which are original including, sag corrections, manual finishing with removal of existing fittings, fixtures, using epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/ damaged/ dilapidated wooden membersand with 2 sidepanel and 1 central panel is made up of 50mm x 38mm finished size burma teak wood with supports of 30mm x 38mm BTC wood having both side panels with same frame size fitted inframe usinf brass butt hinges and central panel fitted with brass pivot of the Heritage structure also glazing of8 millimetreplain glass panels wherever required as per design, glass is fixed by 10mm BTC \"L\" type moulding4 inches 4 brass handles, 4 brass butt hinges, brass pivot with 44\"inches long tower bolt including one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete.Ground floor |
| 117 | first floor |
| 118 | second floor |
| 119 | Restoration of existing old Windows /ventilators paneles considaring 50% of wood dammaged and repalced (windo type 1 ventilator window) - providing, fixing and restoring all sorted old broken/ missing etc. glazed window panels of historic structure which are original including, sag corrections, manual finishing with removal of existing fittings, fixtures, using epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/ damaged/ dilapidated wooden membersand with 2 sidepanel and 1 central panel is made up of 50mm x 38mm finished size burma teak wood with supports of 30mm x 38mm BTC wood having both side panels with same frame size fitted inframe usinf brass butt hinges and central panel fitted with brass pivot of the Heritage structure also glazing of8 millimetreplain glass panels wherever required as per design, glass is fixed by 10mm BTC \"L\" type moulding4 inches 3 brass handles, 4 brass butt hinges, brass pivot with 44\"inches long tower bolt including one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete.Ground floor |
| 120 | first floor |
| 121 | second floor |
| 122 | Restoration of existing old Windows /ventilators with new BTC wood ventilator window (Window type W2 ventilator) - providing, fixing and restoring all sorted old broken/ missing etc. glazed window panels of historic structure which are original including, sag corrections, manual finishing with removal of existing fittings, fixtures, using epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/ damaged/ dilapidated wooden members (consider maximum 50% replacement of the total Windows size) and with 2 sidepanel is made up of 50mm x 38mm finished size burma teak wood with supports of 30mm x 38mm BTC wood having both side panels with same frame size fitted in frame of the Heritage structure new 8 millimetreplain glass panelsas per design, glass is fixed by 10mm BTC \"L\" type moulding for fixing glass also2 brass handles, 4 brass butt hinges, and 24\"inches long tower bolt including one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete.Ground floor |
| 123 | first floor |
| 124 | second floor |
| 125 | Restoration of existing old Windows /ventilators with 50% BTC wood member replaced ventilator window (Window type W2 ventilator) - providing, fixing and restoring all sorted old broken/ missing etc. glazed window panels of historic structure which are original including, sag corrections, manual finishing with removal of existing fittings, fixtures, using epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/ damaged/ dilapidated wooden members (consider maximum 50% replacement of the total Windows size) and with 2 sidepanel is made up of 50mm x 38mm finished size burma teak wood with supports of 30mm x 38mm BTC wood having both side panels with same frame size fitted in frame of the Heritage structure new 8 millimetreplain glass panelsas per design, glass is fixed by 10mm BTC \"L\" type moulding for fixing glass also2 brass handles, 4 brass butt hinges, and 24\"inches long tower bolt including one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete.Ground floor |
| 126 | first floor |
| 127 | second floor |
| 128 | Restoration of existing old Windows ,ventilators with new Ventilator window - providing, fixing and restoring all sorted old broken/ missing etc. single panels glazed window of historic structure which are original including, sag corrections, manual finishing with removal of existing fittings, fixtures, using epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/ damaged/ dilapidated wooden membersand full qty.with of 70mm x 38mm finished size burma teak wood frame, with 2 supports of 40 x 38mm moulded BTC frame,8 millimetre thickplain glass fitted with 10mm BTC \"L\" moulding,also 4inches 2 brass handles, 4 brass butt hinges, and 24\"inches long tower bolt andincluding one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete. ( size :- 1.39 X 0.94, semicircle window)Main building.Ground floor |
| 129 | first floor |
| 130 | second floor |
| 131 | Restoration of existing old Windows /ventilators - providing, fixing and restoring all sorted old broken/ missing etc. single panels glazed window of historic structure which are original including, sag corrections, manual finishing with removal of existing fittings, fixtures, using epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/ damaged/ dilapidated wooden members (consider maximum 50% replacement of the total door size) and full qty.with of 70mm x 38mm finished size burma teak wood frame, with 2 supports of 40 x 38mm moulded BTC frame,8 millimetre thickplain glass fitted with 10mm BTC \"L\" moulding,also 4inches 2 brass handles, 4 brass butt hinges, and 24\"inches long tower bolt andincluding one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete. ( size :- 1.39 X 0.94, semicircle window)Ground floor |
| 132 | first floor |
| 133 | second floor |
| 134 | Restoration of existing old French Type full Windows with frame with New french door type BTC wood window - providing, fixing and restoring all sorted old broken/ missing etc. French type door windo of historic structure which are original including, sag corrections, manual finishing with removal of existing fittings, fixtures, using epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/ damaged/ dilapidated wooden membersand full qty.with frame size 80x110 mm of BTC wood and Shutter made up of 90mm x 38mm finished size burma teak wood frame, with single verticalesupports of 40 x 38mm and 5 horizontal support of 40x38mmmoulded BTC frame,8 millimetre thickplain glass fitted with 10mm BTC \"L\" moulding,also 6 inches 4 brass handles, 16 brass butt hinges, and 8 , 6\"inches long tower bolt andincluding one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete. ( size :- 2.40 X 2.47) Main building.Ground floor |
| 135 | first floor |
| 136 | second floor |
| 137 | Restoration of existing old French Type full Windows with frame,50%BTC wood damage window replacement :-Providing, fixing and restoring all sorted old broken/ missing etc. French type door window of historic structure which are original including, sag corrections, manual finishing with removal of existing fittings, fixtures, using epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/ damaged/ dilapidated wooden membersand full qty.with frame size 80x110 mm of BTC wood and Shutter made up of 90mm x 38mm finished size burma teak wood frame, with single verticalesupports of 40 x 38mm and 5 horizontal support of 40x38mmmoulded BTC frame,8 millimetre thickplain glass fitted with 10mm BTC \"L\" moulding,also 6 inches 4 brass handles, 16 brass butt hinges, and 8 , 6\"inches long tower bolt andincluding one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete. ( size :- 2.40 X 2.47) Main building.Ground floor |
| 138 | first floor |
| 139 | second floor |
| 140 | Restoration of existing old Windows /ventilators with new BTC wood window - providing, fixing and restoring all sorted old broken/ missing etc. single panels glazed window of historic structure which are original including, sag corrections, manual finishing with removal of existing fittings, fixtures, using epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/ damaged/ dilapidated wooden membersand full qty.with of 70mm x 38mm finished size burma teak wood frame, with 2 supports of 30 x 38mm moulded BTC frame,8 millimetre thickplain glass fitted with 10mm BTC \"L\" moulding,also 4inches 3 brass handles, 6 brass butt hinges, and 44\"inches long tower bolt andincluding one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete. ( size :- 0.97 x 1.81 m)(Anex building)Ground floor |
| 141 | first floor |
| 142 | second floor |
| 143 | Third Floor |
| 144 | Restoration of existing old Windows /ventilators with 50%new BTC wood window - providing, fixing and restoring all sorted old broken/ missing etc. single panels glazed window of historic structure which are original including, sag corrections, manual finishing with removal of existing fittings, fixtures, using epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/ damaged/ dilapidated wooden membersand full qty.with of 70mm x 38mm finished size burma teak wood frame, with 2 supports of 30 x 38mm moulded BTC frame,8 millimetre thickplain glass fitted with 10mm BTC \"L\" moulding,also 4inches 3 brass handles, 6 brass butt hinges, and 44\"inches long tower bolt andincluding one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete. ( size :- 0.97 x 1.81 m)(Anex building)Ground floor |
| 145 | first floor |
| 146 | second floor |
| 147 | Third Floor |
| 148 | Restoration of existing old Windows with ventilator with new BTC window - providing, fixing and restoring all sorted old broken/ missing etc. single panels glazed window of historic structure which are original including, sag corrections, manual finishing with removal of existing fittings, fixtures, using epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/ damaged/ dilapidated wooden membersand full qty.with of 70mm x 38mm finished size burma teak wood frame, 8 millimetre thickplain glass fitted with 10mm BTC \"L\" moulding,also 4inches 3 brass handles, 6 brass butt hinges, and 44\"inches long tower bolt andincluding one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete.Ground floor |
| 149 | first floor |
| 150 | second floor |
| 151 | Restoration of existing old Windows with ventilator with 50% BTC wood missing members window - providing, fixing and restoring all sorted old broken/ missing etc. single panels glazed window of historic structure which are original including, sag corrections, manual finishing with removal of existing fittings, fixtures, using epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/ damaged/ dilapidated wooden members (consider maximum 50% replacement of the total door size) and full qty.with of 70mm x 38mm finished size burma teak wood frame, 8 millimetre thickplain glass fitted with 10mm BTC \"L\" moulding,also 4inches 3 brass handles, 6 brass butt hinges, and 44\"inches long tower bolt andincluding one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete.Ground floor |
| 152 | first floor |
| 153 | second floor |
| 154 | Restoration of existing old Fix Windowswith new BTC wood Fix window - Providing, fixing and restoring all sorted old broken/ missing etc. single panels glazed window of historic structure which are original including, sag corrections, manual finishing with removal of existing fittings, fixtures, using epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/ damaged/ dilapidated wooden membersand full qty.with of 50mm x 38mm finished size burma teak wood frame, with 1 supports of 40 x 38mm moulded BTC frame,8 millimetre thickplain glass fitted with 10mm BTC \"L\" moulding, andincluding one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete. ( size :- 1.35 X 1.06, ) ANEX BUILDING.Ground floor |
| 155 | first floor |
| 156 | second floor |
| 157 | Third floor |
| 158 | Restoration of existing old Fix Windowswith 50% replacement of BTC wood - Providing, fixing and restoring all sorted old broken/ missing etc. single panels glazed window of historic structure which are original including, sag corrections, manual finishing with removal of existing fittings, fixtures, using epoxy/ saw dust to fill uneven surfaces, making the surface smooth and ready to polish, replacing missing/ damaged/ dilapidated wooden members (consider maximum 50% replacement of the total door size) and full qty.with of 50mm x 38mm finished size burma teak wood frame, with 2 supports of 40 x 38mm moulded BTC frame,8 millimetre thickplain glass fitted with 10mm BTC \"L\" moulding, andincluding one coat of PU sealer and two coats of PU polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete. ( size :- 1.35 X 1.06, fix step frame window) ANEX BUILDING.Ground floor |
| 159 | first floor |
| 160 | second floor |
| 161 | Third floor |
| 162 | Providing and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202-1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, matfinish stainlesssteel fixtures fastenings, finishing with french- polish/ waxing complete. (without door frame).Ground floor |
| 163 | first floor |
| 164 | second floor |
| 165 | Third floor |
| 166 | Providing and applying P.U.polish/ P.U. Paint of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary.Ground floor |
| 167 | first floor |
| 168 | second floor |
| 169 | Third floor |
| 170 | Providing and fixing Burma teak wood frame with / without ventilator of size as specified for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 millimetrex 40 millimetre x 5 millimetreincluding one coat of primer and two coates of oil paint for wood, As directed by Engineer in charge etc. complete - For door frames. (Wood section size 0.085mete X 0.085 metre X 2.70 metre)Ground floor |
| 171 | first floor |
| 172 | second floor |
| 173 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre asperdrawing including fixtures,necessarywelding andpainting with one coatsof anticorrosive paint and two coats of oil painting complete.Ground floor |
| 174 | first floor |
| 175 | second floor |
| 176 | Providing structural steel work in single stanchions composed of R.S.J. Channel etc. with caps, bases, mild steel plated, angle brackets, cleats, gussetplates, anchorbolts etc.as per detailed designs and drawings or as directed including cutting, fabrication, hoisting, erecting fixing in position, making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it two.coats of oil painting approvedquality and shade etc. complete.Ground floor |
| 177 | first floor |
| 178 | second floor |
| 179 | Providing and applying 2 coats of alluminium paint of approved make to new structural steel workin building s and workshops including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat)etc. complete.ground floor |
| 180 | first floor |
| 181 | second floor |
| 182 | Providingandfixing Indian teakwoodeavesboards15cm wide and25mm thick plain decorative type including scaffolding and painting with two coats etc. complete.ground floor |
| 183 | first floor |
| 184 | second floor |
| 185 | Providing and fixing crimped wire G.I. mesh of size 20mm x 20mm 10 guage to iron angle frame including welding crimp mesh to angle frame and steel flat, fixingthe frame in its original position and oil painting etc. complete. (excluding cost of structural steel) |
| 186 | Providing and fixing sheet glass of 24 oz. for all size including putty etc. complete. |
| 187 | Providing antitermite treatment to the wooden frames of doors/windows of the existing building as per I.S. 6313 (Part-III) by drilling 6mm dia. holes at four corners on one side and four corners on other side at a down ward angle of about 45% at the junction of wood work and masonary and injecting 150ml. of chlorodane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee.ground floor |
| 188 | first floor |
| 189 | second floor |
| 190 | Third floor |
| 191 | Plastering and pointingProvidinglime plaster 12 mm thick in a single coat in 1 : 3 lime mortar, with smooth finish to concrete or brick or stone surfaces, in all positions including scaffolding and curing complete. |
| 192 | Providing and applying Pointing to stone masonry in 1:3 lime mortar (1 lime : 3 Sand) or pure lime using specialist tools to match old stone work, cleaning, curing, scaffolding at all heights, etc., complete. |
| 193 | Providingand applyingprimingcoatovernew/old steeland other metalsurfaces including preparingthesurfacebythoroughlycleaningoil,grease,dirtand other foreignmatterand scouredwithwirebrushes,finesteelwool,scrappersandsand paper,scaffoldingetc. complete. |
| 194 | Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary , andwateringthe surface for two days etc complete. |
| 195 | Excavationforfoundationinearth,soilofalltypes,sand,gravelandsoftmurum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthe buildingareaand stackingandspreadingasdirected,dewatering,preparingthebed forthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means |
| 196 | Excavation for foundation in hard murum including removing the excavated materials upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Manual Means |
| 197 | Filling in plinth and floors with contractors soil sand or murum in 15 cm to 20cm, layers including watering and compaction complete. |
| 198 | Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with sand/grit ramming, watering complete. |
| 199 | Providing and casting in situ cement concrete M-15 of trap / granite / quartzite / gneiss metal for steps including centering, formwork, compacting, roughening them if special finish is to be provided and curing and finishing if required complete,with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer with natural sand. |
| 200 | Providing and laying in situ cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, formwork, cover blocks compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) complete, With fully automatic micro processor based PLC with SCADA enabled reversible drum type concrete mixer . With natural sand. |
| 201 | Providing and casting in situ cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement).With fully automatic micro processor based PLC with SCADA enabled reversible drum type concrete mixer. With natural sand. |
| 202 | Providing & casting in situ cement concrete M-20 of trap / granite /quartzite/gneiss metal for R.C.C. beams and lintels as per detailed designs & drawings or as directed including centering, formwork, cover blocks compaction & roughening the surface if special finish is to be provided & curing complete. (Excluding reinforcement). With fully automatic micro processor based PLC with SCADA enabled reversible drum type concrete mixer With natural sand. |
| 203 | Providing and casting in situ cement concrete M-20 of trap/ granite / quartzite/gneiss metal for R.C.C. slabs and landings canopy, waist slab with steps as per detailed designs and drawings including centering, formwork, cover blocks compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement).With fully automatic micro processor based PLC with SCADA enabled reversible drum type concrete mixer With natural sand. |
| 204 | Providing & casting in situ cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design & drawings including centering, formwork, cover blocks compacting & roughening the surface if special finish is to be provided & curing complete. (Excluding reinforcement).With fully automatic micro processor based PLC with SCADA enabled reversible drum type concrete mixer With natural sand. |
| 205 | Providing and casting in situ cement concrete M-20 of trap/ granite / quartzite/gneiss metal for R.C.C. pardi, as per detailed designs and drawings including centering, formwork, cover blocks compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement).With fully automatic micro processor based PLC with SCADA enabled reversible drum type concrete mixer With natural sand. |
| 206 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 207 | Providing first class Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints pointing in c.m. 1:3 and watering in pillars of curved shapes, as shown on the drawing or as directed complete. |
| 208 | Providing coursed rubble masonry Second sort of trap/ granite/ quartzite/ gneiss stones in cement mortar 1:6 in external walls of plinth including, bailing out water, striking joints inside and racking out joints from outside and watering complete. |
| 209 | Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 mm thick in C.M. 1:4 using waterproofing compound at 1 Kg. per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 mm thick in C.M. 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding etc. complete. |
| 210 | Providing internal cement plaster 20mm. Thick in Single coats in cement mortar 1:3 with out neeru finish ,to concrete, brick surface, in all positions includings caffolding and curing etc.complete. |
| 211 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing complete. |
| 212 | Providing and fixing mild steel grill gate with angle iron frame 65 mm x 65 mm x 10 mm with iron bars at 150mm.C/C and diagonal flats as per the detailed drawing including hinges, pivot blocks locking arrangement, welding riveting and oil painting of three coats of approved shade. Weight of gate 35 Kg/smt. |
| 213 | Providing flush grooved pointing with cement mortar 1:3 for stone masonary work including scaffolding and curing complete. |
| 214 | Providing & laying water proof treatment of terrace slab with B.B. Coba in all position with an average thickness of 112 mm consisting specialised materials as per the manufactures specifications and covering 10 years guarantee on court fee stamp paper including all lead, lift, etc. complete. |
| 215 | Providing, laying and fixing P.V.C. pipe of 25mm dia. with fittings such as bends, tees,reducers,clamps,etc.includingnecessaryexcavation,trenchfillingetc. complete.Includingremoving existing pipe line if necessary and conveying and stackingthesameinPWD chowky or as directed etc. complete. |
| 216 | Providing, laying and fixing P.V.C. pipe of 40 mmdia. with fittings such as bends, tees,reducers,clamps,etc.includingnecessaryexcavation,trenchfillingetc. complete.Includingremoving existing pipe line if necessary and conveying and stackingthesameinPWD chowky or as directed etc. complete. |
| 217 | Providing and laying 100mm diameter half round salt glazed stoneware pipes in brick masonry including fittings such as bends, tees, single junction, necessary excavation and jointing complete |
| 218 | Providing and laying polished Shahabad Stone Flooring 25 mm to 30 mm thick and required width in Plain/diamond pattern with black polished caddappa stone slab for border or any other design on a bed of 1:6 Cement mortar or 1:11/2 lime mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning complete.- For Toilet waiting lobby |
| 219 | Providing and laying ceramic tiles of approved quality 30cm x 30cm x 5 mm for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry cleaning curing complete.Ground floor |
| 220 | first floor |
| 221 | Second floor |
| 222 | Providing andlaying vitrified rustic matt stone finish tileshaving size 590 mm to 605 mm x590mm to 605mm of8to 10mm thicknessandconfirming to IS.15622-2006 (Group Bla) of approvedmake,shadeandpatternforflooringinrequiredposition laid onabedof1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.Note: (Water absorption should not be more than 0.05%) |
| 223 | Providing and preparing kitchen otta made up from 30 mm thick and 75 cm. wide one side polished kadappa top 75cm high vertical support for kadappa at 1 m. c/c of 25mm thick both side polished kadappa middle shelf and bottom of 20 mm thick one side polished kadappa with facia patti of 20 x 50mm kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etc. complete. |
| 224 | Providing & fixing orissa type colour glazed earthenware 625 x 450 mm w.c. pan including trap, C.I. soil & vent pipe upto the out side face of wall including 100mm. dia. C.I. plug, bend, 15mm thick 10 litre PVC flushing cistern with all necessary pipe connection etc. complete. |
| 225 | Renewing by Providing and fixing new Indian type Ivory glazed earthenware. 580 mm W.C. Pan with ‘P’ trap including C.C. or lime concrete bedding and making good damages making connections to water supply and drainage and making good the deficiencies if any. |
| 226 | Providing and fixing coloured glazed earthenware Wash Hand Basin of 55 cm. x 40 cm. size including cold water piller tap/cold and hot water piller tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap upto the outside face of the wall. |
| 227 | Providing and fixing stainless steel sink of size 600 x 510 x 200 mm of Nirali or equivalent make incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. |
| 228 | Providing and applying pearl/luster finish paint of approved colour and shade to the existing plastered surface including scaffolding, preparing the surface, applying primer and the acrylic wall putti etc. complete. Spec. No. : As directed by Engineer in charge. |
| 229 | Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary cleaning and preparing the surfaces, watering for two days complete. |
| 230 | Providing leak proof treatment by Injection grouting method to old floor without removing tiles of W.C., bath, with cement sand proportion of 1:1.5 and water proofing compound at 2 Kg/bag of cement mixed in 35 litres of water including drilling holes in required position grouting with above mixed solution and ceiling etc. complete.Spec. No.: As directed by Engineer in charge. |
| 231 | Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery upto destination hoisting and fixing of accessories such as inlet, outlet over flow pipe inclusive of all tanks capacity between 200 to 1000 liters |
| 232 | CompactHandTowelDispenser, ProductCode – 4980 / 2014 |
| 233 | FoamSoapDispenser, ProductCode – 2013 |
| 234 | AirNeutralizerDispenserProgrammable, ProductCode – 1284 |
| 235 | JumboRollTissueDispenser, ProductCode - 1307 |
| 236 | PersonalSeatCoverDispenser, ProductCode - 1260 - For VIP Toilets |
| 237 | Providing and fixing Decorative Cast iron Brackets for Awnings or chajjas as per given design, including hoisting, erecting, fixing in position, making welded connections and two coats of oil painting complete. |
| 238 | Providing & fixingOFFICER TABLE VENEER having size of 1.80x0.90x0.75 meter made up ofCOMMERTIAL I.S 303 Plywith pedestal made up of 18mm & 12mm plywoodas per approved drawing with 400 mm channels for key board and 600 mm channels for drawerslidersand using Whinges for shutters to be fixed with magnet, S.S. door chains Handel 100mm, ENOX drawer lock andfinished with 4mm thickNatural wood VENEER ( Flitchess metallic burl vereer series ). confirming to (ISI 1328) and finished with Melamine polishing Matt or GlossyPremium quality in approved design & groves,Plywood edges to be finished with BTC lipping Internaly finished with Internaly finished with 0.8 mm Laminate confirming (ISI 2046), outer edges melamine polishing antiermite treatment and as directed by engineer In charge etc complete.second floor |
| 239 | Providing and fixing OFFICE TABLE SIDE RUNNER WITH DRAWER made up of COMMERTIAL I.S 303 Ply and back with 12mm thick commertialply and shutter with 18mm plywood as per architectural desing & drawing and finish with 4mm thick Natural wood VENEER like ( Flitchess metallic burl vereer series ) etc. confirming to (ISI 1328) and finished with Melamine polishing Matt or GlossyPremium quality and inside surfece finish with french pollish, including BTC lipping, 75mm brass hinges, brass screws, SS 304 grade handel, drawer locks, s.s. chain , 100mm brass tower bolt, magnet,drawer chanel 400mmmelamine pollish to moulding / lipping antitermite treatment to plywood , labour chargesand as directed by engineer Incharge etc complete.second floor |
| 240 | Providing & fixingCONFERANCE ROOM TABLE FINISHED WITH LAMINATEhaving size of 6.60 X 0.60 X0.75 m(HT)as per detailed drawing with following specificationsmade up of SANIK CENTURY COMMERTIAL I.S 303 Plyor equivalent brand18mm thick comertial plywood and finished with 1.00mm thick AEROLAM MAKE LAMINATE confirming to (ISI 2046) or equvalent make Premium quality in approved design & groves,Plywood edes to be finished with BTC lipping internal face is finished with1.00mm thick AEROLAM MAKE LAMINATE confirming to (ISI 2046) & outeredges is finish withmelamine polishing, antitermite treatment etc complete.second floor |
| 241 | Providing & Fixing 6.00 mm Thick Solid Surface Material (Dupont / Corian Acryalic White ) over Plywood or Wooden Surface Including all hardware and Labour changes , with buffing and making surface by polishing sud glossy or matte etc complete.second floor |
| 242 | Providing & fixingVENEER WALL PANELLING made up ofCOMMERTIAL I.S 303 Ply18mm thick plywoodframe work of 75mm patti at 600mm x600mm center to center covered with 18 mm thick comertialplywood finished with 4mm thickNatural wood VENEER ( Flitchess metallic burl vereer series ) etc. confirming to (ISI 1328) and finished with Melamine polishing Matt or Glossy Premium quality as per approved design ,Plywood edges to be finished with BTC lipping, melamine polishing to molding antitermite treatment as directed by engineer In charge etc complete.second floor |
| 243 | Providing & fixingLAMINATED WALL PANELLING made up ofCOMMERTIAL I.S 303 Ply18mm thick plywoodframe work of 75mm patti at 600mm x600mm center to center covered with 18 mm thick comertialplywood finished with 1.00mm thick LAMINATE confirming to (ISI 2046)Premium quality as per approved design ,Plywood edges to be finished with BTC lipping, melamine polishing to moulding antitermite treatment and as directed by engineer In charge etc complete. |
| 244 | Providing and fixing Decorative charcoalstrips paneling to walls, Paneling made up of frame work 18mm comertial IS 303 plywood double patti0.075 m width at 0.60 M center to center and covered with 18mm thick plywood. Decorative readymade charcoal strips panele patti of 0.125 x 3.04 M size is fitted on plywood panel using Probond adhesive and edges finished with 0.045 x 0.012 mm Charcoal molding As Directed By Engineer Incharge etc complete. |
| 245 | Providing & Fixing 48 MM thick ONE SIDE LAMINATEDAND OTHER SIDE VEENERDOORmade up of 18mm thickCOMMERTIOL( ISI-303)plywood frame covered with 12mm thick COMMERTIOL( ISI-303) plywood both side of the frame to get required thickness as per architectural design & drawing AndFinish with One side 1.00mm thick LAMINATE confirming to (ISI 2046) and Other side Finish With4mm thickNatural wood VENEER ( Flitchess metallic burl vereer series ). confirming to (ISI 1328) and finished with Melamine polishing Matt or Glossywith grove, edges finish with 50 X 10mm BTC lipping strip as per drawing is fitted by BTC 22 X 10mm moulding including all matarials brass scruw, brass hinges (125 X 12mm,)mortilse lock, door stopper, antitarmite treatment to plywood, melamine pollish to moulding and lipping, labour charges etc. complete. |
| 246 | Providing & Fixing 48 MM thick both side VENEER DOOR (WITHOUTGLASS) made up of 18mm thickCOMMERTIOL( ISI-303)plywood frame covered with 12mm thickCOMMERTIOL( ISI-303) plywood both side of the frame to get required thickness as per architectural design & drawing . Premium quality with grove, edges finish with 50 X 10mm BTC lippingas per drawing is fitted by BTC 22 X 10mm moulding including all materials brass screw, brass hinges (125 X 12mm,) mortice lock, door stopper, antitermite treatment to plywood, two coats melamine pollish to moulding and lipping, labour charges as directed by engineer Incharge etc complete.second floor |
| 247 | Providing & Fixing 48 MM thick both side VENEER DOOR (WITHOUTGLASS) made up of 18mm thickCOMMERTIOL( ISI-303)plywood frame covered with 12mm thickCOMMERTIOL( ISI-303) plywood both side of the frame to get required thickness as per architectural design & drawing . Premium quality with grove, edges finish with 50 X 10mm BTC lippingas per drawing is fitted by BTC 22 X 10mm moulding including all materials brass screw, brass hinges (125 X 12mm,) mortice lock, door stopper, antitermite treatment to plywood, two coats melamine pollish to moulding and lipping, labour charges as directed by engineer Incharge etc complete.second floor |
| 248 | Providing and laying wall paper with cutting and fitting as per approved design.second floor |
| 249 | ProvidingandFixingRollarBlindsAMIMakeorapprovedmake&shadeof38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work)second floor |
| 250 | ProvidingandFixingMineralFibreAcousticalSuspendedCeilingSystemwithFine Fissured(BevelledTegular)EdgeTilesofsize15mmExposedGrid.Thetilesshould haveHumidityResistance(RH)of99%,NRC0.6,LightReflectance85%,Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 16mm , with Recycled content of 31 %. The tile shall be laid on precoated G.I channel height of 32 with 15 mm wide T - section flanges colour white having rotary stitching and XL2 CLIP on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32mm and a load carrying capacity of 7.57Kilograms/M2andpulloutstengthofminimum100Kilograms..TheTSections haveaGalvanizingof90grams perM2 and need tobeinstalledwith Suspension system. TheTileand Grid systemusedtogethershouldcarrya10yearwarranty. product approved in GRIHA and BS 476 etc. complete.second floor |
| 251 | Providing and fixing frame work of galvanised iron for suspended false ceiling whichincludes galvanised iron perimeter channels of size 27 mm and 0.5 mm thickhavingone flange of 20 mm and another of 30 mm along with perimeter of the ceiling,fixing inbrickwall / partition with thehelp of rawal plugs and screws, suspendinggalvenisediron intermediate channels of size 45 mm and 0.9 mm thick with two flanges of 15 mm each from the soffit at 1200 mm centers withsteel galvanisediron hangerofwidth 25mm x0.5 mm fasteners, ceiling section of 0.5 mmthickness havingcurvedwedgeof51.5mmandtwo flanges of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with the help of connecting clips and in direction perpendicular to the intermediate channel at 450 mm centers, 12.5mmdrywallsscrewsat230mmcenters;fixingscrewsmechanicallyeitherwith screw driver or drilling machine with suitable attachment etc. complete.second floor |
| 252 | Providingandfixingfalseceilingof10to12mmthickdecorativeboardsoffibrous plaster of paris including scaffolding if necessary all architectural work like mouldings, cornices,coves,domes, cups as per detailed drawings and three coats of spray painting to boards etc.complete.(excludingframework,runnersandmildsteel suspenders).second floor |
| 253 | Providingandfixingoffactory madeuPVCSlidingwindow&door(WhiteColour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section1.5 mm, wherever required.uPVC window & door profile shall be made in India &shallconformtoBSEN12608andotherstandardsasmentionedbelow: S.No. Name of the testTest MethodSpecified Parameter1 Tensile Impact Strength ISO 8256- more than 700Kj/m22 )Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3. Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 )Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 (b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 )Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 \"P\" Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 )Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glassinthesash,uPVCglazingbead,interlock,EPDM/TPEgasket,brushshallbe providedincludingtouchlockandrollers&properdrainagesystemshallbeprovided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge.uPVC Window and Door Profilesarewarrantedforaperiodoften(10)yearsagainstnon-uniform discoloration, wrapping and rotting under general use. f) 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of door)(Big Series) Door frame of size 122 x 54 mm & Door Sash ofsize 85 x 47mm & Mesh sash of size 85 x 47 mm.second floor |
| 254 | Providingandapplyinginteriorwallfinishlusterofapprovedmakeoninternalwall surface as detailedbelow Scrapping the surface with emery paper and wipe clean wall primerwithbrushwith mineral turpentine with brush 8 to 10% and oil 15 to 20%withrollerand allowingtodryforaperiod6to8hours.wallputtywith appropriateproportionofwater allowing to dry forperiod4to 6hours.Scrapping withEmerypaper180andwipe clean. Applyingwall primer withbrushwithmineral turpentine 8 to 10% andoil 15 to 20% with rollerScrappingEmerypaper320and wipeclean,interiorwallfinishluster1stcoatwith brush/rubber/spraywithmineral turpentine 7to 9%andOilwithroller19 to 21% After8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9% withbrushandOil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity.(With prior approval of S.E.)second floor |
| 255 | Providing& Arrangemnt of High Back, Synchronized Mechanismwith Multiple Locking,AdjustableArmrest,GasliftforSeatheightadjustment,Standard5-prong P/Nylon Basewith Leatherite Upholsterysecond floor |
| 256 | Providing and supplying on sitevisitors chairwith round 2 mm. thk pipe frame with chrome finish with reinforced pipe inserts having moulded seat and back with nylon back cover with PP armrest hanging back fabric etc. complete.(B1019 INDIAN) VISTER CHIAR TYPE -1 second floor |
| 257 | Providing & fixing Shutter & Shelf To Wall Cupboard having size of 0.90x0.60x2.10 meter made up ofCOMMERTIAL PLYWOOD(ISI-303) e with 18 mm COMMERTIAL PLYWOOD(ISI-303) plywood to frame work shutter & Frame work is made up of 18 mm plywood as per approvedcdetail drawing including hinges for shutter ,Handle 100mm ,drawer lock ,Magnet, Chain ,and finish with 1.00mm thickLAMINATE confirming to (ISI 2046)primium qualityin approved design & grooves .Plywood edges to be finish with BTC lipping internal french polish ,melamine antitermite treatment and as directer by engineer incharge etc completed . |
| 258 | Providing and fixing Signages of various sizes using 12mm thk marine waterproof ply with teakwood moulding all around with frame 40 X 25mm as per approved design, including with sticker of directional statutory information signages as per approved design and matter fixed at the location. as directed by Engineer in charge. |
| 259 | Providing and fixing double leaf half glazed and half panelled door shutter with burma teak wood members excluding frame with shutter members 37millimetrethick as per detailed drawing consisting panelled vertical styles 95millimetrex 37millimetreand lock rail 250millimetrex 37millimetreand bottom rail 195 mm x 37 mm with 25mm thick BTC wood panelsand 12millimetre glass panels with 40mm bavelling fixed in 40millimetrewooden members fixed into burma teak 10 mm moulding \"L\" type,including Brassfixtures and fastening in that 6 nos 4inches openingparlimantary hinges, 9 inches long brass tower bolts, 300mm long double door aldrop fitting, 6 inches long 4 nos of handles,1/2\" BTC.W. beading at cross work on glass panel and at junctions of panel inserts one coat of primer and two coats of melamine polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete.Ground floor |
| 260 | first floor |
| 261 | second floor |
| 262 | Third Floor |
| 263 | Providing and fixing double leaf half glazed and half panelled door shutter with burma teak wood members excluding frame with shutter members 37millimetrethick as per detailed drawing consisting panelled vertical styles 95millimetrex 37millimetreand lock rail 250millimetrex 37millimetreand bottom rail 195 mm x 37 mm with 25mm thick BTC wood panelsand 12millimetre glass panels with 40mm bavelling fixed in 40millimetrewooden members fixed into burma teak 10 mm moulding \"L\" type,including Brassfixtures and fastening in that 6 nos 4inches openingparlimantary hinges, 9 inches long brass tower bolts, 300mm long double door aldrop fitting, 6 inches long 4 nos of handles,1/2\" BTC.W. beading at cross work on glass panel and at junctions of panel inserts one coat of primer and two coats of melamine polish, all the necessary fittings, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete. (consider maximum 35% replacement of BTC wood the total door size)Ground floor |
| 264 | first floor |
| 265 | second floor |
| 266 | Third Floor |
| 267 | Providing and fixing Heritage type old design hevey type BrassDouble Door Fitingfixtures and fastening in that 6 nos 4\" x 8\"parlimantary hinges, 8\" inches long brass tower bolts,12\"x 16mm thickdouble door aldrop fitting, 6 inches long 4 nos of handles, andall the necessary screws hardwer labour, to be fixed at the location, all inclusive, as directed by Engineer in charge etc. complete. |
| 268 | Electical Work - Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. |
| 269 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP |
| 270 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. |
| 271 | Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA |
| 272 | Supplying & erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 273 | Supplying & erecting triple pole and neutral distribution board (TPNDB),SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 274 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 275 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 276 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 277 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 278 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 279 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 280 | Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 281 | Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 282 | Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 283 | Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 284 | Supplying & erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 285 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 286 | Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVCinsulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 287 | Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 288 | Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 289 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 290 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 291 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 292 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 293 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 294 | Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVCconduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular typeswitch,earthing and required accessories as per specification No: WGPW/ SW. |
| 295 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections |
| 296 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 297 | Supplying and erecting PVC Surface modular switch box with doublemounting plate for 6 module duly erected. |
| 298 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia withnecessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 299 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 300 | Supplying and erecting decorative pendent type brass lamp holder complete erected with their accessories. The fitting having following specification type of fitting : Indoor,Mounting : Suspension, net weight : 2.5 kg dimensions :Lamp Shade Diameter : 12.99 inch, Lamp Shade Height : 4.13 inch,Lamp max reach from ceiling to shade : 76.77 inch, canopy diameter : 3.54 inch, canopy height : 2.16 inch, Wattage : 20 W , Color temperature : 3000 K , Bulb base : E27, Cord length : As per site condition , Light effect : Diffused IP rating: 20, Material : Brass & Copper including driver complete with 3 year warranty as per site specification. The fitting should be inspected & tested at manufacturing place before dispatch. At site from engineer in charge or as directed by engineer in charge. |
| 301 | Supplying & erecting inverter LED batten 20W tube light fitting withpolycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. |
| 302 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 200 mm width & 20 mm height complete with necessary hardware. |
| 303 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware. |
| 304 | Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority |
| 305 | Supplying, installing, testing and commissioning of 40 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 75 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate,canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB ,MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG. |
| 306 | Supplying and installation of Solar PV Module cleaning unit consisting ofnozzles spray, necessary pipes, valves, post, electronic panel board concealed with weather proof cabinet, spreading water periodically for removal of dust, related motor pump, controller, timer and nozzles set suitable for covering 5 KW Solar PV Module. (Approx. 35 Sq. Mtr. PV Module area). |
| 307 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 308 | Supplying and erecting AC three phase LT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz, with backlit LCD display, optical port & RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD,tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. |
| 309 | SE building Meter panelFabricating & Supplyinstallingtesting and commissioning ofMain Electrical control panel( Size : 2.2 Mtr X 2 Mtr X 0.4 Mtr ). INCOMING 1 nos. 400A 3P MCCB,1 Sets of 500 Amps. Aluminium Bus bars with colour coded heat shrinkable PVC sleeves 1 Set of RYB indicating lamps with individual MCB 1 No.flush mounted panel metersuitable rated current transformers1 No. 0-500V.OUTGOINGFEEDER FOR MAIN PANEL - 100 A TP MCCB(1 Nos.), 63 A FP RCCB (16 nos.)All the components shall be housed in a common cubical made of 16 swg. M.S.sheet .The panel shall be powder coated of approved colour both inside & out side. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height with necessary accessories etc completed. |
| 310 | CE buidling Meter Panel - Fabricating & Supply installingtesting and commissioning ofMain Electrical control panel( Size : 2.5 Mtr X 2 Mtr X 0.4 Mtr ).INCOMING 1 nos. 400A 3P MCCB,1 Sets of 500 Amps. Aluminium Bus bars with colour coded heat shrinkable PVC sleeves 1 Set of RYB indicating lamps with individual MCB 1 No.flush mounted panel metersuitable rated current transformers1 No. 0-500V.OUTGOINGFEEDER FOR MAIN PANEL - 100 A TP MCCB(1 Nos.), 63 A FP RCCB (11 Nos.), 40 A FP RCCB (2 nos.),16 A DP RCCB (1 nos.)All the components shall be housed in a common cubical made of 16 swg. M.S.sheet .The panel shall be powder coated of approved colour both inside & out side. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height with necessary accessories etc completed. |
| 311 | Supplying and erecting triple pole mini feeder pillar with 500V, 200A FPMCCB as incomer and 2 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation complete as per specification no. SWSWR/MFP |
| 312 | Supplying and erecting triple pole mini feeder pillar with 500V, 300A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation as per specification no. SW-SWR/MFP |
| 313 | Supplying, installation, testing and commissioning extendable/non-extendable outdoor type 11 kV 630A, load break isolator switch, compliant to IEC 62271 - 100, 200 and 102,on provided MS channels/trench/foundation as per specification no SW-HTS / LBS |
| 314 | Supplying, erecting, testing & commissioning 11kV, 630A, 21kA/3sec, 3 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 1 no. feeder with 1 LBS and 2 nos. feeder with 2 VCB. compliant to IEC 62271 -100,200 and 102, as per specification no. SW-HTS/RMU SCADA |
| 315 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete |
| 316 | Supplying and erecting GI sheet 1.6mm (16 SWG) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for HV/EHV (11000 Volts) installation with compliance to IS 2551-1982 |
| 317 | Supplying and erecting AC three phase HT CT multifunction net meterDLMS compliance of accuracy class 0.5, 3x 63.5V, 50Hz, with backlit LCDdisplay, optical port & RS 232 port( measures import kWh, kVAh, export kWh, kVAh, net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. |
| 318 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 319 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 320 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 321 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 322 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 120 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 323 | Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as perspecification no. CB-JT/HT |
| 324 | Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 325 | Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 326 | Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 630 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound Non-sealed transformer delta/star connected additional neutral brought out on load side, temperature rise should not exceed 45? by thermometer in oil and 50? by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, having 7 number of tap positions , with standard accessories complete with test certificate with losses below 1860 Watts at 50% load, 5300 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL. |
| 327 | Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG |
| 328 | Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD |
| 329 | Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to |
| 330 | Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete. |
| 331 | Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete. |
| 332 | Providing and making second class Burnt Brick masonry with conventional /I.S. type bricks in cement mortar 1:6 in foundation sand plinth of inner walls /in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. |
| 333 | Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. |
| 334 | Supplying & arranging burnt cured bricks properly for various purposes (size 9”x4.25”x3”) at work for 100 bricks complete. |
| 335 | Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 Kilogram). |
| 336 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). |
| 337 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 338 | Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W,CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V,inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 339 | Supplying and erecting Street light bracket made from 25 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC |
| 340 | Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 341 | Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet,outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. |
| 342 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 343 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 344 | Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVCinsulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 345 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). |
| 346 | Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority |
| 347 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 348 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. |
| 349 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 350 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 351 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 352 | Supplying & erecting 50 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW |
| 353 | Supplying & erecting 100 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW |
| 354 | Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 355 | Supplying, erecting & commissioning MDF Box 150x150 pairs made frommin. 1.5mm thick MS sheet as per specification no. WG-TW |
| 356 | Supplying, erecting & commissioning MDF Box 800x800 pairs made frommin. 1.5mm thick MS sheet as per specification no. WG-TW |
| 357 | Supplying, erecting & commissioning 50 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 358 | Supplying, erecting & commissioning 150 pairs M.S. junction box made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 359 | Supplying and installing, testing & commissioning of digital (hybrid) typeEPABX of 6 x 32 extensions suitable upto 96 extensions complete. |
| 360 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 361 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC |
| 362 | Supplying and fixing 24 port patch panel with tool-less keystone jacks inprovided U Rack complete as per specification no. WG-NAS/PP |
| 363 | Supplying and fixing 24 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fibre cables in provided U rack complete as per specification no. WG-NAS/ LIU |
| 364 | Supplying and fixing SC/LC type multimode duplex adapter to couple two connectors between OFC & Fibre switch/Fibre module as per specification no. WG-NAS/MMA |
| 365 | Supplying and fixing 1 x 12 duplex adapter panel - SC complete |
| 366 | Supplying and fixing SC/LC type multimode pigtails (OM3) for LIU to terminate OFC in LIU as per specification No. WG-NAS/LIU2 |
| 367 | Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, core dia 50/125 µm (OM3), suitable upto 10 GBPS, ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-COC/OFC LSZH |
| 368 | Supplying and installing armoured single mode optical fibre cable with 6 fiber, core dia 50/125µm (OS1/OS2) 10/40 GBPS speed in provided underground HDPE pipe complete. |
| 369 | Supplying and plugging 3 m fibre patch cord LC-SC MM (50) OM3 LSZHduplex complete as per specification no. WG-COC/FPC |
| 370 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK |
| 371 | SITC of Electric Traction Passenger Lift with · Rated capacity :- 6 Passenger/408Kg · Floors :- G+2 floor (3 Stops/3 Landings) · Travel :- 3 to 12 mtrs · Location of Lift Machine:- MRL · Rated speed :- 1.0mps VS· Car/Landing door clear opening of 800 mm wide x 2000mm high · Clear Car size of 1650 mm wide x 1650 mm deep x 2250mm high · Lift shaft available having clear size of 2660 mm wide x 2700 mm deep, 1500 mm Pit depth,4250 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including liftmotor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine ofarless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & \"License to Work the Lift\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. Add on: 1.For additional one floor As per page no 274 Item A 2 For full collective control system page no 276 Item B 1 |
| 372 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 373 | Supplying and erecting modular type 3 pin 6A multi socket with safetyshutter, duly erected on provided plate and box with wiring connections |
| 374 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. |
| 375 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 376 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 377 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 378 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 379 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erectedon angle iron/GI frame. |
| 380 | Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A, withovercurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakagetrip indication as per specification no SW-RCCB/RCBO |
| 381 | Supplying, fixing and commissioning 4 pole RCBO 63A, with overcurrent,rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 382 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 383 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 384 | Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA |
| 385 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. |
| 386 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 387 | Supplying & erecting single phase, 240V, street light control panel up to the max load of 12kW, SPN MCB 63A, powder coated CRCA 14 SWG sheet,outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs.astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation & overcurrent, short circuit,earth fault protection on provided iron frame / CC foundation. |
| 388 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 389 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 390 | Supplying & erecting triple pole and neutral distribution board (TPNDB),SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 391 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 392 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 393 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 394 | Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB |
| 395 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 396 | Supplying & erecting flat flexible 3 core 2.5 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 397 | Supplying and erecting Supplying, fixing and commissioning of recessed uplighting exterior ratedIP66-67Gea Power LED Pro U220 mm Efficiency LED,Luminaire Total Power:28.9 W, Operating Voltage/Frequency: 100-240 V 50/60 Hz, inrush current 45A,inrush time 0.45 ms,Power factor of 0.92,Inbuilt dynamic DMX controller included in fixture,Real lumens:623, Real lm/W : 22,Corelated Colour Temperature(CCT),RGBW,UGR<=16,Structure material:aluminium structure :AISI 316 stainless steel Diffuser material: Tempered Glass Diffuser finish : Transperent Driver brand:Meanwell, Dimming protocol,DMX RDM Power Factor 0.92 including driver having mounting arangement,Life class of 50,000 hrs at L80B20 compleet with 3 years warranty. |
| 398 | Supplying and erecting Supplying, fixing and commissioning of Spotlight IP66 Cube Pro 4 LEDS LED 16W RGBW Inbuilt Dynamic DMX controller included in fixture, Urban grey 997lm, Real lumens : 997, Real lm/W : 62,Correlated Colour Temperature (CCT) : RGBW, Lens / reflector angle : SPOT 16ºUGR : <=16, Structure material : Aluminium Structure finish : Urban grey Diffuser material : Glass Diffuser finish : Transparent, Voltage / frequency : 24VDCDimming protocol : DMX Power Factor : 1.00 Useful life : 50.000h L80B20with of external rated meanwell driver 24V - 200W - constant voltage, Operating Voltage / frequency: 100 -240V/50-60Hzinclusive ofDynamic DMX controllerWarranty: 3 years, Resistant to marine environments: Yes |
| 399 | Supplying and erecting Supplyingfixing and commissioning ofExternal rated Led strip On Performace 9.6W/m,48W per 5 meter, RGBW CRI 80 IP65 2576lm per 5 meter, Lens / reflector angle: HORIZONTAL112º, Equipment necessary but not included, Voltage / frequency: 24VDC Useful life: 50,000h L80B20 with external rated meanwell driver 24V - 150W - constant voltage, Operating Voltage / frequency: 100 - 240V/50-60Hz,inclusive ofDynamic DMX controllerWarranty: 3 years with aluminium extrusion |
| 400 | Supplying and erecting Supplying, fixing and commissioning ofExtrnal rated Led strip 3 mtr Asai Top Bend RGBW 1000mm 19.2 W RGBW IP67Red / Green / Blue: 4W/m. Neutral White: 7.2 W/m. RGB +NW: 19.2W/m. Lumens :- Red: 69.94lm, Green: 179.68lm Blue: 44.35lm RGB: 271.91lm NW: 319.86lm, Color Temperature (CCT): Red: 1001k Green: 7889k Blue: 100000k RGB: 14068k NW: 3861k, Structure material: PVC, Diffuser material: PVC Diffuser finish: Semitransparent, Useful life: 50,000h L80B20 Warranty: 3 years with mounting clipv including driverwith aluminium extrusion |
| 401 | Supplying and erecting Supplying, fixing and commissioning of of external rated Lineal lighting system IP65- IP67 Mex Surface Big LED 24, Luminaire total power: 24W, Real lumens: 370, Real lm/W: 15 Correlated Colour Temperature (CCT): RGBW, Lens / reflector angle: FLOOD 71º UGR: <=19, Structure material: Aluminium Structure finish: Urban grey Diffuser material: Glass Diffuser finish: Transparentincluding driver having mouting arrangement with Warranty: 3 years. |
| 402 | Supplying and erecting Supplying, fixing and commissioning of Reccessed of external rated Lineal lighting system IP65- IP67 Mex Recessed Big LED 24, Real lumens: 370 Real lm/W: 15, Correlated Colour Temperature (CCT): RGBW, Lens / reflector angle: FLOOD 71º, UGR: <=19 Structure material: Aluminium Structure finish: Urban grey Diffuser material: Glass Diffuser finish: Transparent Equipment necessary but not included Voltage / frequency: 24VDC Useful life: 50,000h L80B20 including driver having mounting arrangement with Warranty: 3 years |
| 403 | Supplying and erecting Supplying, fixing and commissioning of DMX Controller for controlling RGBW Luminaires for powerful show storage and should work as a playback device capable of delivering light.Each shows to installations with up to 6000 DMX universe having 8 ports . The key features for the controller are as follows - Housing Steel : Aluminium, Input Voltage - 90-264V AC/50 60 Hz , IEC Classification : Class I , CommunicationPortocols : TCP/IP/, Art-Net, Control Versions : DMXS12, DMX512/RDM, Power Consumption: 300W, Number of Universes : Up to 6000, Net weight : 8.5 kh, Temperature Range : 0°C to 40°C. Humidity Range : 10 to 85% ( no condesation),Protection Rating : IP20, Certification : CE, CB,CQC with Warranty: 3 years |
| 404 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 405 | Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 406 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 407 | Supplying & erecting four pole ON LOAD change over switch, 415V, 32A,open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3 . |
| 408 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 409 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting,bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.(1.2x1.2x1=2.88 sqm + 1.2x0.3x4=1.44 sqm total 4.32 sqm @ 18 guage 9.8 kg/sqm 4.32 x 9.8 = 42.33 kg say 42 kg) |
| 410 | Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982 |
| 411 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 412 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 413 | Supplying and layingSupplying and laying(including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete. |
| 414 | Providing Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP |
| 415 | Supplying and erecting minimum Three & above star rated submersiblepump set suitable for erection on open well of 3.75 KW/5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 43 to 11m and discharge from 120 to 840 litres. per minute & pipe of Suction 65mm / Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP |
| 416 | Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C,Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starterhaving relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phaseimbalance etc . |
| 417 | Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. |
| 418 | Supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete. |
| 419 | Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. |
| 420 | Supplying & erecting Float sensor switch for water level controller working on 250V & rated current 8A, with 2 mtr. wire & High quality of wire & plastic body. |
| 421 | Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps). |
| 422 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 423 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 424 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 425 | Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories. |
| 426 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cmcomplete with all materials, testing & recording the results as per specification no. EA-EP |
| 427 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 428 | Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 429 | Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP |
| 430 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP |
| 431 | Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP |
| 432 | Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP |
| 433 | Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessaryfittings complete as per specification no. FF-PP |
| 434 | Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessaryfittings complete as per specification no. FF-PP |
| 435 | Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessaryfittings complete as per specification no. FF-PP |
| 436 | Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850LPM at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 45kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body &bronze impeller with stainless steel shaft(SS410 grade), mechanical sealconforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP |
| 437 | Supplying, installation, testing and commissioning of main fire pump(MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 mhead driven by 76 HP or suitable HP capacity diesel engine at requiredworking speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine, exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP |
| 438 | Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP |
| 439 | Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT |
| 440 | Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV |
| 441 | Supplying and erecting 100 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV |
| 442 | Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV |
| 443 | Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 444 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 445 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 446 | Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 447 | Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 448 | Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 449 | Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG |
| 450 | Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS |
| 451 | Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings,suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 45kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby,alternate run per start in auto mode) comprises of the following features & switchgears: 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU\"s, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. 4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP,O/L & phase reversal protection with emergency stop switch. 5. TPN SPD 100kA Type 1 +2 tested. 6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps. 7. System controller tocontrol operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors,annunciation window for fault indication, complete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications. 9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge. 10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP = (1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECP Add ons: 1. For Hydrant pump Page no 217, Item A 3 2. For Sprinkler pump Page no 217, Item B 4 3. For Diesel pump Page no 218, Item D |
| 452 | Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system. |
| 453 | Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 454 | Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL |
| 455 | Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/NZ |
| 456 | Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve of size ( 400 x 400 x 400)mm or hose pipe box of size ( 600 x 600 x 200)mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mm having front doors with viewing glass of size (200x150) mm and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 457 | Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/ FMC |
| 458 | Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC |
| 459 | Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV |
| 460 | Supplying and erecting 20/25mm dia gun metal air release cock, withnecessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV |
| 461 | Supplying and erecting 50 mm dia gun metal gate valve complete withPN16 pressure rating, as per specification no. FF-VL/GV |
| 462 | Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FFSPR. |
| 463 | S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wallcomplete. |
| 464 | ABC powder type fire extinguisher as per IS 13849/15683 of 6 kg capacity with necessary clamp for erection on wall. |
| 465 | Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-ise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area\"s etc. with 3 years equipment replacement warrantyIS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD. |
| 466 | Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C,humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/SD . |
| 467 | Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \"Break Glass\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP. |
| 468 | Supplying, installing, testing and commissioning of addressable firecontrol/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM |
| 469 | Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH. |
| 470 | Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU |
| 471 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP. |
| 472 | Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP |
| 473 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). |
| 474 | Supplying & erecting Float sensor switch for water level controller working on 250V & rated current 8A, with 2 mtr. wire & High quality of wire & plastic body. |
| 475 | Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |