Tender For Provision Of Ceiling Fans, Water Geyser, Air Conditioners And Water Coolers Against Ber Appliances For Ncc Ota, Gwalior And Fitment Of 12 X Air Conditioner In Green Room, Waiting Room And Other Ancillaries Of The Building No P-83, gwalior-Madhya Pradesh

Military Engineer Services-MES has published Tender For Provision Of Ceiling Fans, Water Geyser, Air Conditioners And Water Coolers Against Ber Appliances For Ncc Ota, Gwalior And Fitment Of 12 X Air Conditioner In Green Room, Waiting Room And Other Ancillaries Of The Building No P-83. Submission Date for this Tender is 25-11-2023. Air Conditioner Tenders in gwalior Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40419687
Corrigendum : Tender For Provision Of Ceiling Fans, Water Geyser, Air Conditioners And Water Coolers Against Ber Appliances For Ncc Ota, Gwalior And Fitment Of 12 X Air Conditioner In Green Room, Waiting Room And Other Ancillaries Of The Building No P-83
Open Tender
Indian
Madhya Pradesh
gwalior
25-11-2023

Tender Details

Provision Of Ceiling Fans, Water Geyser, Air Conditioners And Water Coolers Against Ber Appliances For Ncc Ota, Gwalior And Fitment Of 12 X Air Conditioner In Green Room, Waiting Room And Other Ancillaries Of The Building No P-83

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Oct-2023 Corrigendum 1 Other 13-11-2023
2 13-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-11-2023
3 20-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 95000.0 /-
Tender Value
INR 47.50 Lakhs /-

BOQ Items

Name of Work: PROVN OF CEILING FANS, WATER GEYSER, AIR CONDITIONERS AND WATER COOLERS AGAINST BER APPLIANCES FOR NCC OTA, GWALIOR AND FITMENT OF 12 X AIR CONDITIONER IN GREEN ROOM, WAITING ROOM AND OTHER ANCILLARIES OF THE BUILDING NO P-83
Sl. No. Item Description
1Geyser
2Supply and fix Water heater storage type,electric,capacity 50 litres.BEE 5 star rated
3S&F sheet metal Enclosure with socket Plug top and earth plug, single pole and neutral with single pole MCB 20 Amps 240 volts in repairs complete all as specified and directed.
4S&F in place of u/s PVC Connection of any make with(ISI Mark) having 10 mm dia, 60 cm long with steel reinforcement suitable for hot & cold water geyser outlet supply with 02 nos of unions/cup shaped cover with washers all as directed by engr-in-charge.
5M&L sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 volts grade, 4 Sqmm size with multi stranded copper conductor (ISI marked with valid CML No), drawn in and including surface mounted non metallic rigid PVC conduit (ISI marked with valid CML No) not less than 20mm dia with all accessories including PVC insulated un sheathed 2.5 Sqmmcable with multistranded copper conductor (ISI marked with valid CML No) as connected to earth with dolly complete all as specified and as directed (Cutting of wall and making good disturbed surface of wall shall be measured & paid sepertely.
6Celing Fan/Exhaust fan
7Taking down all size of Ceiling fan,Exhaust fan, sealing cable end, dismantling blades, disconnection and removing fan and blades and deposited to MES store.
8Supply & fixBEE Service value >6.0 ceiling fans(BLDC)1200 mm sweep(Non remote type) down rod all accessories required including regd length of 3 core 1.0 sqmm PVC multistranded copper conductor, PVC connector for proper hanging of fan and testing complete all as specified and directed.
9Supply & fixBEE Service value >6.0 ceiling fans(BLDC) 1400 mm sweep(Non remote type), down rod all accessories required including regd length of 3 core 1.0 sqmm PVC multistranded copper conductor, PVC connector for proper hanging of fan and testing complete all as specified and directed.
10Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with double ball bearing, blades, and frame and louvers complete.
11Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep with double ball bearing, blades, and frame and louvers
12Air Conditioner
13Taking down & disconnection ofall type/size of air conditioner complete all deposited to MES Store Carefully all as specified and directed by Eng-in-charge.
14Supply and install, Cold and Hot Hi wall split unit indoor/outdoor complete with cordless remote control unit and with in built air ionizer and Plasma filter for better indoor air quality of 1.5 TR capacity three star rating with Echo friendly Refrigerant R-410 complete all as specified and directed.
15Supply and install, Cold and Hot Hi wall split unit indoor/outdoor complete with cordless remote control unit and with in built air ionizer and Plasma filter for better indoor air quality of 2 TR capacity three star rating with Echo friendly Refrigerant R-410 complete all as specified and directed.
16Supply and fix window type air conditioner electric driven (single phase), cooling capacity 4500 K Cal per hour (1.5 Ton) BEE 5 star rated Complete.
17Supply and fix window type air conditioner electric driven (single phase), cooling capacity 4500 K Cal per hour(2 Ton) BEE 5 star rated Complete.
18S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilizer at 230 V with accuracy of + 2.5% and of capacity 4 KVA complete all as specified and directed.
19Water Cooler
20Supply, installation,commis-sioning of Water cooler fully stainless steel, electric driven single phase having approx storage 60/120 ltr and nominal cooling capacity all as specified and directed.
21Supplying and laying of PPR/CPVC pipes of size 20 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trench complete including taking out old pipes all as specified and directed. Note : GI/CPVC Combination Sockets & interconnection services included in the Quated rate.
22Supplying and laying of GI Pipe, "medium grade of size 20 mm",fittings on walls/ceiling or laying in floors/trench complete including taking out old pipe all as specified and directed. Note : GI/CPVC Combination Sockets & interconnection services included in the Quated rate.
23Taking down carefully existing aluminum / copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed.
24S&F PPR/CPVC BALL VALVE confirming to IS 14846/2000,ISI Mark M including dismantling of old u/s Gate valve fixed at any location of size 20 mm dia all as specified and directed.
25S&Fflexible PVCwest pipe for drainage of water complete all as specified and directed.
26S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilizer at 230 V with accuracy of + 2.5% and of capacity 1 KVA complete all as specified and directed.
27Taking down submain wiring of any size any type and in any position metalic/non metallic PVC conduit of wooden batten complete all as specified and directed.
28M&L, concealed point wiring with PVC insulated and unsheathedelectric cable 1100 volts grade single core FRLSH confirming to IS 694:2010 having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including concealed non metallic rigid PVC conduit medium grade( ISI marked with valid CML No)not less than 20 mm diawith all fitting and fixing accessories and1.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to common earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxesfactory made for mounting switch, regulators etc with and including 2.8 mm thick plastic laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint insidefor mounting switches. sockets etccomplete for the following:-
29One Ceiling fan point controlled by one switch.
30One 3 pin socket outlet 5 Amp controlled by one switch on independent board.
31S&F switch piano, flush button single pole one way 5 Amp complete all as specified and directed.
32S&F Ceiling rose 3 terminal/pvc/polycarbonate, isolated body.
33S&F switch socket combination, flush button, 2 in one 6 pin 5 Amp complete all as specified and directed.
34supply and install hi wall split unit indoor/outdoor complete with cordless remote control unit and with coolingand heating function of capacity 2 ton 3 star rated
35Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 285 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA
36S & F PVC White colour Three core copper conductor 4 Sqmm alongwith PVC pipe for protection from junction box to bracket complete .
37M & L for iron stand for base of split AC outdoor unit, bracing, supports, clamps and back plated fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross arms complete all as specified and as directed.
38Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core
39S&F MCCB DB sheet metal encloser double door with bus bar 415 volt 2 in 1 shuttle type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
40M&L cable jointing kit for LT cable for outdoor termination heat shrink type joint complete with material and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size 25 to 95 sqmm
41S&F aluminium tube terminal in repair heavy duty BS-4579 of size 95sqmm