| 1 | 1.SH:- Academic and Hostel Building Portion:- |
| 2 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, intoplinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 3 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 4 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 5 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.a) Foundations and plinth |
| 6 | Providing and laying damp proof course 38 mm thick with cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 12.5mm nominal size). |
| 7 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in :b) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level. |
| 8 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 9 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 10 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 11 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. |
| 12 | Reinforced cement concrete work in stair casesexcept spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. |
| 13 | Centring and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concrete. |
| 14 | b) Column, pillars, posts and struts etc. |
| 15 | c) Lintels, beams, girders, bressumers and cantilevers etc. |
| 16 | d) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 17 | e) Stairs (excluding landings) except spiral stair cases. |
| 18 | f) Walls including attached buttresses, pilasters etc. |
| 19 | Reinforcement of RCC work including bending, binding and placing in position complete.a) Tar/ TMT steel |
| 20 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
| 21 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 22 | Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position. |
| 23 | Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position. |
| 24 | Providing and fixing 44 mm thick best available local wood Class - B I (19 mm batten and 25 mm bracing) battened and braced doors and windows shutters including providing and fixing necessary bright finished or black enamelled T-hinges, butt hinges, sliding door bolts, tower bolts and handles with necessary bolts and nuts and screws complete. |
| 25 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws.a) 38mm thick best available local wood class - B I |
| 26 | Providing and fixing 38 mm thick wire gauge shutters using galvanized mild steel wire gauge of IS gauge designation 140G with wire of dia 0.56 mm for doors, windows and clerestory windows including anodized aluminum butt hinges with necessary screws.a) Best available local wood class B-I |
| 27 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.a) Ornamental grill. |
| 28 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.a) 300 x 16 mm |
| 29 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete.a) 300 x 10 mm |
| 30 | b) 250 x 10 mm |
| 31 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a) 125 mm for Door |
| 32 | b) 100 mm for Windows |
| 33 | Providing and fixing MS safety hasp and staple with necessary screws etc complete.a) 150 mm |
| 34 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 35 | Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete. |
| 36 | Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately). |
| 37 | Steel work in rallingincluding cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately). |
| 38 | Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate20 mm nominal size) finished with a floating coat of neat cement.b) 50 mm thick |
| 39 | Pre-cast terrazzo tiles 20 mm thick with white, black or white and black marble chips of sizes up to 6 mm laid in floor, treads of steps and landings on 25 mm thick bed of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete with pre-cast tiles of :a) Light shade using white cement |
| 40 | Pre-cast terrazzo tiles 20 mm thick with marble chips of sizes upto 6 mm in skirting and risers of steps not exceeding 30 cm in height on 12 mm thick cement plaster 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry including rubbing and polishing complete with tiles of :a) Light shade using white cement |
| 41 | Extra, if cut tiles other than half tiles are used in risers of steps skirting and dado. |
| 42 | Pre-cast terrazzo tiles 20 mm thick with marble chips of sizes up to 6 mm fixed on wall on 12 mm thick cement plaster 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry including rubbing and polishing complete with tiles of :a) Light shades using white cement |
| 43 | Cement plaster skirting (up to 30 cm height) with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, including rounding of junctions with floor.a) 21mm thick |
| 44 | Providing corrugated G.I.sheet roofing fixed with galvanised iron J or L hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete, excluding the cost of purlins, rafters and trusses.a) 0.83 mm thick GI sheet |
| 45 | Providing ridges or hips 60 cm overall in plain G.I. sheet fixed with galvanised iron J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete.a) 0.83 mm thick GI sheet |
| 46 | Providing and fixing 4.0 mm thick asbestors plain sheet ceiling of approved quality with necessary nails etc.complete (frame work for base to be paid separately). |
| 47 | Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling.a) Best local approved quality wood |
| 48 | Extra for making chamfered edges of beading. |
| 49 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
| 50 | 15 mm cement plaster 1 : 3 (1 cement : 3 fine sand) on the rough side of single or half brick wall. |
| 51 | Providing two coats of acrylic water based wall putty/ wall filler of Asian Paits/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the halp of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department. |
| 52 | Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade. |
| 53 | Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete. |
| 54 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
| 55 | Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work. |
| 56 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade. |
| 57 | Painting one or more coats on GI sheets with superior ready mixed paint of approved brand and manufacture in white, grey or green shades on new work to give an even shade. |
| 58 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 59 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).a)15mm nominal bore. |
| 60 | Providing and fixing brass bib cock of approved quality.a)15mm nominal bore. |
| 61 | Providing and fixing PVC connection pipe with brass union A) 30cm length.a)15mm nominal bore. |
| 62 | b)20mm nominal bore. |
| 63 | Providing and fixing CP brass shower rose with 15 mm or 20 mm dia inlet. 100 mm dia |
| 64 | Painting GI pipes and fitting with two coats of anti corrosive bitumastic paint of approved qualtiy.a) 15 mm dia pipe |
| 65 | b) 20 mm dia pipe |
| 66 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanb) Orissa Pattern WC Pan |
| 67 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 68 | Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan WC.a) 250 x 130 x 30 mm |
| 69 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.a) 50 mm dia |
| 70 | Providing and fixing sand cast iron heel rest sanitary bend.a) 100 mm dia |
| 71 | a) 50 mm dia |
| 72 | Providing and fixing sand cast iron single equal plain junction of required degree.a) 100 x 100 x 100 mm |
| 73 | Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/Aggrigate 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cementmortar1 : 3 (1 cement : 3 fine sand) including shuttering complete. |
| 74 | Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single0 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15Kg). |
| 75 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design. |
| 76 | Providing water storage tank (Sintex) 1000 litre capacity. |
| 77 | Internal Electrification POINT WIRING Point wiring in PVC conduit, with modular type switch.Wiring for light point /fan point/exhaust fan point/call bell point with 1.5 Sq.mm FR PVC insultated copper conductor single core cable in surface/recessed PVC conduit,with modular switch, modular switch, suitable size G.I. box and earthing the point with 1.5 sq. mm.FR PVC insulated copper conductor single core cable etc. as required.Group A |
| 78 | Group B |
| 79 | Group C |
| 80 | Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 81 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (5A Plug). |
| 82 | 2 x 4 sq. mm + 1 x 4 sq. mm earth wire(for power point). |
| 83 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 84 | 25 mm |
| 85 | 32 mm |
| 86 | 50 mm |
| 87 | TV Cable in existing Conduit :-Supplying and drawing co-axial TV Cable RG - 6 grade,0.7 mm solid copper conductor PEinsulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. |
| 88 | S/F modular type switch/socket :-Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 Amps Switch |
| 89 | 15/16 Amps Switch |
| 90 | 5/6 Amps Socket |
| 91 | 15/16 Amps socket outlet |
| 92 | Telephone socket outlet |
| 93 | TV Antenna Socket Outlet |
| 94 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 95 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required |
| 96 | Supplying and fixing brass batten/ angle holder includingconnection etc. as required. |
| 97 | Erection of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required. |
| 98 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required |
| 99 | Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc as required. |
| 100 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.5/6 amps switch |
| 101 | Installation, testing and commissioning of resistance type ceiling fan regulator,in existing switch box including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable,earthing the regulator etc. as required. |
| 102 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 510 mm sweep |
| 103 | CHAPTER 2 – MCCB, MCB & DB’S Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP&N |
| 104 | 63 Amp TP&N |
| 105 | Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp |
| 106 | 125 Amp |
| 107 | 250 Amp |
| 108 | Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.4 way (4 + 12), Double door |
| 109 | 6 way (4 + 18), Double door |
| 110 | EARTHING Copper Plate Electrode :- Earthing with Copper plate 600 x 600 x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc.(but withoutcharcoal or coke and salt) complete as required. |
| 111 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required |
| 112 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 113 | Septic Tank Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more tha |
| 114 | Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 115 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 116 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 |
| 117 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth an |
| 118 | Reinforcement of RCC work including bending, binding and placing in position complete.a) Cold twisted bars |
| 119 | Centring and shuttering including strutting, propping etc. and removal of form work for:a)Suspended floors, roofs, landing shelve and theirsupports, balconies and chajjas (3.50m height) |
| 120 | b)Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 121 | 12 mm thick cement plaster 1:3( 1 cement : 3 fine sand) |
| 122 | Neat cement punning |
| 123 | Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement.a) 40 mm thick. |
| 124 | Furniture as per yardsticks For Classroom Wooden Table |
| 125 | Wooden Chairs (armed) |
| 126 | Woden Desk |
| 127 | Wooden Bench |
| 128 | Dustbin |
| 129 | For DormitoryWooden Cots with mosquito net stand |
| 130 | Wooden Chairs (armed) |
| 131 | Wooden Table |
| 132 | Alluminium Water filter 19 ltr. Cap. |
| 133 | Carrying Charge. LOADING AND UNLOADING Carriage of Cement/steel/CGI Sheet,etc from Tinsukia to work site i/c loading, unloading & staking to countable manner as per the direction of Engineer-In-Charge (Hill Road)Tinsukia to work site |
| 134 | Aggregate, sand, boulder |
| 135 | Carriage of materials Cement/steel 155Km |
| 136 | Aggregate i/c sand, boulder & planks Surfaced Road 60 |
| 137 | Unsurfaced Graveled Road 8 |
| 138 | Katcha Track and Track in River Bed/Nallag Bed and Choe Bed 2 |
| 139 | Boundary Wall 180.911 Meter Length Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides offoundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 140 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement :4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 141 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 142 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :a) M-20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 143 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm toa) M-20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 144 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M-20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 145 | Centring and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concrete. |
| 146 | b) Column, pillars, posts and struts etc. |
| 147 | c) Beam , linteletc. |
| 148 | Reinforcement of RCC work including bending, binding and placing in position complete.\"a) TMT steel |
| 149 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:4(1 cement : 4 fine sand). |
| 150 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 151 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 152 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 153 | 15 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall. |
| 154 | Providing and fixing MS grills of required pattern in wooden frames ofwindows etc with MS flat, square or round bars with round headed bolts andnuts or by screws.a) Ornamental grill. |
| 155 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 156 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 157 | Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work. |
| 158 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade. |