Tender For Repair/ Replacement Of Ht Line, Marshelling Yard Mrs, Different 11Kv Sub Station Including Repair Of Transformer And Connected Other Works Under Ge Missamari

Issued by Statutory Bodies & Commissions/Committees · missamari, Assam
Tender Value
95 Lakhs
Estimated cost
Bid Submission
24 Nov 2023
0 days left
EMD
1.67 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
missamari → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair/ Replacement Of Ht Line, Marshelling Yard Mrs, Different 11Kv Sub Station Including Repair Of Transformer And Connected Other Works Under Ge Missamari

BOQ

Nature of Work: REPAIR/REPLACEMENT OF HT LINE, MARSHELLING YARD MRS, DIFFERENT 11 KV SUBSTATION INCLUDING REPAIR OF TRANSFORMER AND CONNECTED OTHER WORKS AT MISSAMARI UNDER GE MISSAMARI
Sl. No. Item Description
1Excavation in Trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable/Pole/Stays etc getting out in Soft/Loose Soil, complete all as specified and as directed.
2Excavating in Trenches, not exc. 1.50 Metre wide and exc. 1.50 Metre but not exc. 3.00 Metre in depth, for Foundation of Poles/ Stays, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed.
3Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed.
4Removing Surplus Soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed.
5Dismantling unserviceable Steel Tubular Poles of any description and any size including demolition of Cement Concrete (as/if required) and made good disturbed Ground, complete all as specified and as directed.NOTE : Unserviceable Poles will be dismantled at Ground Level and disturbed ground will made good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately.
6Dismantling Stay Assembly of any description and any size including Mild Steel Clamps with Bolts, Nuts and Washers etc., complete all as specified and as directed. NOTE: Unserviceable Stay Assembly will be dismantled at Ground Level and disturbed ground will bemade good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately.
7Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc., and segregating aside for serviceable for re-use complete all as specified and as directed.
8Dismantling Insulators like Pin type, Shackle type from existing Electric Poles of any description and any size, seggregating Seviceable Insulators and keep in safe custody for re-use, complete all as specified and as directed.
9Dismantling ACSR or AAC Conductors from the Disturbed Span including Line Spacer, etc., complete all as specified and as directed.
10Dismantling Earth Wire, Cradle Guarding, etc., complete all as specified and as directed.
11Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections and joints including Pipes, Bricks, etc of any description laying in trenches or fixing with Walls/Poles, segregating serviceableCables etc, and keep in safe custody for reuse, complete all as specified and as directed.NOTE : Earthwork will be measured and paid under appropriate Items.
12M&L Cement Concrete 1:4:8 (40mm graded aggregate) as Lean Concrete in Foundation of Poles, Stay Assembly, etc., including Formwork (as/if required), complete all as specified and as directed.
13M&L Cement Concrete 1:3:6 (40mm graded aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as/if required) complete all as specified and as directed.
14M&L Cement Concrete 1:2:4 (20mm graded aggregate) as in Coping of Poles, etc. and finishing the Concrete surfaces Fair and Even including necessary Formwork required at Site(s), complete all as specified and as directed.
15Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-55 (11.0 Metre long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Painting over a coat of Aluminium Primer (Externally from Top of Coping) including writing MES Pole No.with synthetic Enamel Paint (First Grade/quality), complete all as specified and as directed.NOTE : Earthwork, Cement Concrete, etc. will be measured and paid under approprite Items.
16M&L Stay Assembly complete with Accessories as show in Electrical Plate No. 1 of MES Schedule Part-I, diameter of Stay Rod 20mm,including 7/4.00 mm Galvanised Stay Strand, complete all as specified and as directed.NOTE: Earthwork, Cement Concrete, Mild Steel Stay Clamps with Bolts, Nuts, etc., Loop Insulator, etc. will be measured and paid under approprite Items.
17M&L Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primerone Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed.
18Refixing only Cross-arms, Bracings, Supports, Clamps and Back Plates (serviceable materials i.e. Structural Steel Sections obtained from Item No. 7 here-in-before) including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primer one Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed.
19S&F Insulator Pin type Porcelain, Vitreous, White, Brown or Green including one Galvanised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut, 150mm Height, 150mm dia for 11 KV grade, complete all as specified and as directed
20Fixing only Pin type Porcelain, Vitreous, White, Brown or Green including one Galvanised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut, 150mm Height, 150mm dia for 11 KV grade, (Serviceable Insulator obtained from Item No. 8 here-in-before) complete all as specified and as directed
21S&F Disc type insulatorporcelain, vitreous,145mm high and 255mm dia ball and socket Type white , brown or green insulatorsingle Disc Assembly for tension with Tension Clamps for conductors working pressure 11000 Volts, complete all as specified and as directed.
22Fixing only Disc type insulatorporcelain, vitreous,145mm high and 255mm dia ball and socket Type white , brown or green insulatorsingle Disc assembly for tension with tension Clamps for conductors working pressure 11000 Volts (Serviceable Insulator obtained from Item No. 8 here-in-before), complete all as specified and as directed.
23S&F Loop Type Insulator Vitreous White, Brown or Green, large size with overall dimensions 90x140mm, clearance of hole 25.50 mm dia, complete all as specified and as directed.
24S&F Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) with permissible Sags and providing Jumper, etc., fixing on Electric Poles and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening, etc., complete all as specified and as directed.NOTE : Cost of Binding Wire is deemed to be included in the quoted Unit Rate.
25RestringingACSR Conductor of existing OH Lines by un-binding from Insulator of any description, re-fixing after stretching, re-stringing the Conductor, removing excess Sag, maintaining proper distance between Conductors as ordered, and binding to insulatorswith Aluminium Binding Wirecomplete all as specified and as directed.NOTE : Cost of Binding Wire is deemed to be included in the Quoted Unit Rate.
26S&F Cradles, hexagonal/rectangular fabricated with Galvanised Steel Wire with 4.00mm dia including binding with Aluminium Binding Wire, complete all as specified and as directed.NOTE : Cost of Binding Wire is deemed to be included in the Quoted Unit Rate.
27M&L Danger Notice Plate of 1.6 mm thick Mild Steel Sheet, vitreous enamelled white, with Letters, Figures and Conventional Skull and Bones in Signal Red colour and fixed with MS Clamps Bolt and Nuts of approved size, for HT 25x20 Cm size including dismantling unserviceable one, complete all as specified and as directed .
28S&F Lightning Arrester Expulsion type complete with all Fittings Transmission Class discharge capacity 65 KA suitable,for working pressure 11000 Voltsincludingdismantling of old unserviceable and connection to earth Strip, complete all as specified and directed.
29S&F Lightning Arrester Expulsion type complete with all Fittings Transmission Class discharge capacity 65 KA suitable,for working pressure 33000 Voltsincludingdismantling of old unserviceable and connection to earth Strip, complete all as specified and directed.
30S&F Expulsion Fuse, Single Pole, Channel type/drop out type suitable as per Site requirement with Working Pressure 11 KV grade of capacity 200 Amps including taking down unservice-able Fuses, complete all as specified and as directed.
31S&F Switch Air Break Gang Operated for 11 KV grade, Triple Pole vertically mounted on insulator and fitted on steel frame , current rating 200 Amps, mechanically operated mechanism from Ground Level consisting ofOperating Rod of GI Pipe 25mm bore (dia) ‘light grade’ of suitable Length worked From Ground Level and with Locking Arrangement Mild Steel Flat Iron Clamp 50x6mm including dismanting old unserviceable Switch Air Break of any description, complete all as specified and as directed
32Dismantling Air Break Gang Operated SwitchesHT 11 KV 3 Phase,any capacity ( 200/400 ) Amps vertical / horizontal mounted including Insulators and Operating Mechanism for repair/replacement of broken / worn out components and insulators etc. with or without taking down from Pole all as directed.NOTE :- (a)Parts needed to be replaced shall be measured and paid seperately as \"supply only\" against appropriate Items of Schedule. However Labour component involved in replacement is included inUnit Rate quoated against this Item.The Unit Rate shall deemed to be included for handling of serviceable materialsfor reuse to site andas directed(b)Any minor repairs involved to make the GODfunctionaleven if notified by Engineer-in-Charge shall be carried out by the Contractor without any extra cost to the Department.
33Supply only Male Contact/ Moving Contact Blade suitable for Air Break Gang Operated Switches, 11KV, complete all as specified and as directed.
34Supply only Female Contact/ Fix ContactJaw suitable for Air Break Gang Operated Switches, 11KV, complete all as specified and as directed.
35Supply only Tinned Copper Flexible Jumper 200/400 Amps, suitable for Air Break Gang Operated Switches, 11KV, complete all as specified and as directed.
36Supply only MS Jumper Carrier, suitable for Air Break Gang Operated Switches, 11KV, complete all as specified and as directed
37Supply only Back Connector Plate, suitable for Air Break Gang Operated Switches, 11KV, complete all as specified and as directed
38Supply & laying HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, ‘Earthed Grade, cross-sectional area 95 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed.NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
39Supply & laying HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, ‘Earthed Grade, cross-sectional area 120 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed.NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
40Supply & laying HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, ‘Earthed Grade, cross-sectional area 240 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed.NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
41Re-laying HT XLPE Cable,(Obtained from Item NO.11) insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, ‘Earthed Grade, cross-sectional area 95/120/240 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed.NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
42M&L Cable End Jointing KitIndoor Termination Cold Shrinkable type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 50 Sqmm to 95 Sqmm complete all as specified and as directed
43M&L Cable End Jointing KitIndoor Termination Cold Shrinkable type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 120 Sqmm to 185 Sqmm complete all as specified and as directed
44M&L Cable End Jointing Kit indoor Termination Cold Shrinkable type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 240 Sqmm to 300 Sqmm , complete all as specified and as directed
45M&L Cable End Jointing Kit Outdoor Termination Cold Shrinkable type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 50 Sqmm to 95 Sqmm complete all as specified and as directed
46M&L Cable End Jointing Kit Outdoor Termination Cold Shrinkable type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 120 Sqmm to 185 Sqmm , complete all as specified and as directed
47M&L Cable End Jointing Kit Outdoor Termination Cold Shrinkable type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 240 Sqmm to 300 Sqmm , complete all as specified and as directed
48M&L Cable Jointing Kit Straight Through Termination Heat Shrink-able type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 50 Sqmm to 95 Sqmm complete all as specified and as directed.
49M&L Cable Jointing Kit Straight Through Termination Heat Shrink-able type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size120 Sqmm to 185 Sqmm complete all as specified and as directed.
50M&L Cable Jointing Kit Straight Through Termination Heat Shrink-able type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 240 Sqmm to 300 Sqmm complete all as specified and as directed.
51S&F Pre-cast Reinforced Cement Concrete 1:2:4 (20mm graded aggregate) TypeB-1 of size (0.5M X 0.05MX1.0M) Cable Route Indicator including embossing \"DANGER/11KV CABLE/MES\" on both sides andpainted Letters with approved Colour, burried in ground for a depth of 45 Cm including necessary Earth Work, complete all as specified and as directed.
52M&L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for.
53S&F Unreinforced Pre-cast Concrete Cable Cover, Class HV type 2 flat of size 450x180x40mm with minimum average breaking load 350 Kg, as per IS-5820:1970, complete all as specified and as directed.
54Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 80mm bore (dia) for passing of UG Cable, complete all as specified and as directed.NOTE: GI Pipe laid will be measured and paid separately under appropriate Item.
55S&F Galvanised Iron Pipe 80mm bore (dia), Light grade as in protection of UG Cable laid in Trenches, complete all as specified and as directed.
56Taking out Transformer from its Position from any location under GE Missamari for repair /servicing/ rewindingofcapacity 300 to 500 KVA , 11/0.433 Volts disconnecting /openingHV, LV Electrical connections, earthing connections along with following other works. (a) Transportation of transformer to workshop at Tezpur/ Guwahati and back to siteby making necessary arrangements of T&P (crane, recovery, vehicle, tripoid to be arranged by firm ) as directed. (b) Opening of transformer top cover by extraction ,removingof serviceable - unserviceable nuts bolts and washers etc, (c). Lifting primary coil (HT) and secondary coil (LT) , dismantaling of transformer complete part by part carefully , and display all the parts without damaging any portion, (d) Refilling topping up of transformer oil after dehydration and filteration in transformer. (e). Reassembeling the transformercomplete with all existingserviceable parts, andnew parts as ordered . (f) Reinstall the Transformer at site in position as directed after repair connectingHV, LV electrical connections, earthing connections and testingto entire satisfaction on load . Note- (j) Replacement of userviceable parts like; Bush insulator, brass studs, cork gasket, breather assembly, tap changer, rewinding , reinsulation of Primary and secondary coil with copper winding wire, dehydration and filteration of transformer oil etc shall be measured and paid seperately under appropriate Item of schedule.(k) Renewal ofadequate size Nut, bolts & washers of transformer top cover shall deemed to be included in UNIT RATE QUOATED(l) Contractor has toinstall another transformer of same capacity with his own arrangement in place of unserviceable transformer untill the transformer come from workshop for installation at existing place.and cost of stand by transformer will not be paid seperately.
57Taking out Transformer from its Position from any location under GE Missamari for repair /servicing/ rewindingofcapacity 63 to 250 KVA , 11/0.433 Volts disconnecting /openingHV, LV Electrical connections, earthing connections along with following other works. (a) Transportation of transformer to workshop at Tezpur/ Guwahati and back to siteby making necessary arrangements of T&P (crane, recovery, vehicle, tripoid to be arranged by firm ) as directed. (b) Opening of transformer top cover by extraction ,removingof serviceable - unserviceable nuts bolts and washers etc, (c). Lifting primary coil (HT) and secondary coil (LT) , dismantaling of transformer complete part by part carefully , and display all the parts without damaging any portion, (d) Refilling topping up of transformer oil after dehydration and filteration in transformer, (e). Reassembeling the transformercomplete with all existingserviceable parts, andnew parts as ordered , (f) Reinstall the Transformer at site in position as directed after repair connectingHV, LV electrical connections, earthing connections and testingto entire satisfaction on load , Note- (j) Replacement of userviceable parts like; Bush insulator, brass studs, cork gasket, breather assembly, tap changer, rewinding , reinsulation of Primary and secondary coil with copper winding wire, dehydration and filteration of transformer oil etc shall be measured and paid seperately under appropriate Item of schedule.(k) Renewal ofadequate size Nut, bolts & washers of transformer top cover shall deemed to be included in UNIT RATE QUOATED(l) Contractor has toinstall another transformer of same capacity with his own arrangement in place of unserviceable transformer untill the transformer come from workshop for installation at existing place.and cost of stand by transformer will not be paid seperately.
58Taking out Voltage stabliser from its Position from UAV under GE Missamari for repair /servicing/ rewindingofcapacity 200 KVA , 433 Volts disconnecting /opening Electrical connections, earthing connections along with following other works. (a) Transportation of voltage stabilizer to workshop at Tezpur/ Guwahati and back to siteby making necessary arrangements of T& P (crane, recovery, vehicle, tripoid to be arranged by firm ) as directed, (b) Opening of voltage stabilizer top cover by extraction ,removingof serviceable - unserviceable nuts bolts and washers etc , (c) Dismantaling of voltage stabilizer complete part by part carefully , and display all the parts without damaging any portion, (d) Refilling topping up of voltage stabilizer oil after dehydration and filteration in voltage stabilizer, (e) Reassembeling the voltage stabilizercomplete with all existingserviceable parts, andnew parts as ordered , (f) Reinstall the voltage stabilizer at site in position as directed after repair connecting electrical connections, earthing connections and testingto entire satisfaction on load , Note- (g) Replacement of userviceable parts like; Bush insulator, brass studs, cork gasket, breather assembly, tap changer, rewinding , reinsulation of Primary and secondary coil with copper winding wire, dehydration and filteration of transformer oil etc shall be measured and paid seperately under appropriate Item of schedule.(h) Renewal ofadequate size Nut, bolts & washers of voltage stabilizer top cover shall deemed to be included in UNIT RATE QUOATED
59Taking out Voltage stabliser from its Position from Baffle range and 180MH under GE Missamari for repair /servicing/ rewindingofcapacity 100 KVA , 433 Volts disconnecting /opening Electrical connections, earthing connections along with following other works. (a) Transportation of voltage stabilizer to workshop at Tezpur/ Guwahati and back to siteby making necessary arrangements of T& P (crane, recovery, vehicle, tripoid to be arranged by firm ) as directed, (b) Opening of voltage stabilizer top cover by extraction ,removingof serviceable - unserviceable nuts bolts and washers etc, (c) Dismantaling of voltage stabilizer complete part by part carefully , and display all the parts without damaging any portion, (d) Refilling topping up of voltage stabilizer oil after dehydration and filteration in voltage stabilizer, (e) Reassembeling the voltage stabilizercomplete with all existingserviceable parts, andnew parts as ordered ,(f) Reinstall the voltage stabilizer at site in position as directed after repair connecting electrical connections, earthing connections and testingto entire satisfaction on load , Note- (g) Replacement of userviceable parts like; Bush insulator, brass studs, cork gasket, breather assembly, tap changer, rewinding , reinsulation of Primary and secondary coil with copper winding wire, dehydration and filteration of transformer oil etc shall be measured and paid seperately under appropriate Item of schedule.(h) Renewal ofadequate size Nut, bolts & washers of voltage stabilizer top cover shall deemed to be included in UNIT RATE QUOATED
60Taking out potential transformer from its Position from main receiving stationunder GE Missamari for repair /servicing/ rewindingof 33 KV disconnecting /openingHV, LV Electrical connections, earthing connections along with following other works. (a) Transporation of transformer to workshop at Tezpur/ Guwhati and back to siteby making necessary arrangements of T&P (crane, recovery, vehicle, tripoid to be arranged by firm ) as directed, (b) Opening of PT top cover by extraction ,removingof serviceable - unserviceable nuts bolts and washers etc, (c). Lifting primary coil (HT) and secondary coil (LT) , dismantaling of PT complete part by part carefully , and display all the parts without damaging any portion, (d) Refilling topping up of oil after dehydration and filteration in transformer, (e). Reassembeling the PTcomplete with all existingserviceable parts, andnew parts as ordered , (f) Reinstall the PT at site in position as directed after repair connectingHV, LV electrical connections, earthing connections and testingto entire satisfaction on load& Note- (g) Replacement of userviceable parts like; , rewinding , reinsulation of Primary and secondary coil with copper winding wire, dehyderation and filteration of oil etc shall be measured and paid seperately under appropriate Item of schedule.(h) Renewal ofadequate size Nut, bolts & washers of PT top cover shall deemed to be included in UNIT RATE QUOATED
61M&L for rewinding HT coil of 11/ 0.433 KV Transformerany capacity using proper size DPC copper wire and insulation material , heating coils in heat chamber after rewindingincluding taking out carefully burnt unserviceable copper winding of coilscomplete all as specified and directed.
62Re-insulation of HT coil of transformer of any capacity using proper size paper insulation material to form DPC Copper wire and HT insulation material suitable for HT 11 KV transformer complete all as specified and directed.(Note : Item shall be measured only where re-insulation of copper wire is required.)
63M&L for rewinding LT coil of 11/ 0.433 KV Transformerany capacity using proper size DPC copper wire and insulation material , heating coils in heat chamber after rewindingincluding taking out carefully burnt unserviceable copper winding of coilscomplete all as specified and directed.
64Re-insulation of LT coil of transformer of any capacity using proper size paper insulation material to form DPC Copper wire and insulation material suitable for HT 11 KV transformer complete all as specified and directed.[Note : Item shall be measured only where re-insulation of copper wire is required].
65Servicingto transformer at site of capacity 50 KVA to 250 KVAinstalled on Plinth/ Pole mountedstructure byopening top cover& replacingunserviceable spares / components of transformer ,without lifting core assembely reassemblingafter repair & testing complete allas specified anddirected by Engr-in-Charge. Note- (a) Replacement of userviceable parts like; Bush insulator, brass studs, cork gasket, breather assembly, tap changer,etc shall be measured and paid seperately under appropriate Item of schedule.
66Servicingto transformer at site of capacity 300 KVA to 500 KVAinstalled on Plinth/ Pole mountedstructure byopening top cover& replacingunserviceable spares / components of Distributiontransformer ,without lifting core assembely reassemblingafter repair & testing complete allas specified anddirected by Engr-in-Charge. Note- (a) Replacement of userviceable parts like; Bush insulator, brass studs, cork gasket, breather assembly, tap changer,etc shall be measured and paid seperately under appropriate Item of schedule.
67Servicingto Power transformer at site of capacity 1600 KVAinstalled on Plinth mountedstructure byopening top cover& replacingunserviceable spares / components of Powertransformer ,without lifting core assembely reassemblingafter repair & testing, complete allas specified anddirected by Engr-in-Charge. Note- (a) Replacement of userviceable parts like; Bush insulator, brass studs,breather assembly, etc shall be measured and paid seperately under appropriate Item of schedule.
68Servicingto Power transformer at site of capacity 3150 KVAinstalled on Plinth mountedstructure byopening top cover& replacingunserviceable spares / components of Powertransformer ,without lifting core assembely reassemblingafter repair & testing, complete allas specified anddirected by Engr-in-Charge. Note- (a) Replacement of userviceable parts like; Bush insulator, brass studs,breather assembly, etc shall be measured and paid seperately under appropriate Item of schedule.
69M&L for preparation of old painted steel or iron surfaces of transformer of 50 to 100 KVA , 11/0.433 Volts capacity transformers by scrapping with steel wire brush/scrapper emery paper, etc. and applying two coats of synthetic enamel smoke grey paint over a coat of red oxide primer (painting shall be done by spray machine) including writing of SM No, MES No etc. at prominent place/location of transformer with black synthetic enamel thick paint in white back ground complete all as specified and directed.
70M&L for preparation of old painted steel or iron surfaces of transformer of 150 to 200 KVA , 11/0.433 Volts capacity transformers by scrapping with steel wire brush/scrapper emery paper, etc. and applying two coats of synthetic enamel smoke grey paint over a coat of red oxide primer (painting shall be done by spray machine) including writing of SM No, MES No etc. at prominent place/location of transformer with black synthetic enamel thick paint in white back ground complete all as specified and directed.
71M&L for preparation of old painted steel or iron surfaces of transformer of 250 to 500 KVA , 11/0.433 Volts capacity transformers by scrapping with steel wire brush/scrapper emery paper, etc. and applying two coats of synthetic enamel smoke grey paint over a coat of red oxide primer (painting shall be done by spray machine) including writing of SM No, MES No etc. at prominent place/location of transformer with black synthetic enamel thick paint in white back ground complete all as specified and directed.
72Supply onlyCeramic Bush insulators on LT side as per existing size, shape and specification for capacity 315 to 500 KVA, 11/0.433 Volts transformers
73Supply onlyCeramic Bush insulators on LT side as perexisting size, shape and specification for capacity 200 to 300 KVA, 11/0.433 Voltstransformers
74Supply onlyCeramic Bush insulators on LT side as perexisting size, shape and specification for capacity 50 to 150 KVA, 11/0.433 Voltstransformers
75Supply onlybrass studon LT side as per existing size, shape and specification for capacity 315 to 500 KVA, 11/0.433 Voltstransformers
76Supply onlybrass studon LT side as per existing size, shape and specification for capacity 200 to 300 KVA, 11/0.433 Voltstransformers
77Supply onlybrass studon LT side as per existing size, shape and specification for capacity 50 to 150 KVA , 11/0.433 Volts transformers
78Supply only cork sheet gasket(set of four) for ceramic bushing on LT side as per existing size, shape and specification complete for capacity 315 to 500 KVA, 11/0.433 Volts transformers
79Supply only cork sheet gasket(set of four) for ceramic bushing on LT side as per existing size, shape and specification complete for capacity 200 to 300 KVA, 11/0.433 Volts transformers
80Supply only cork sheet gasket(set of four) for ceramic bushing on LT side as per existing size, shape and specification complete for capacity 50 to 150 KVA, 11/0.433 Volts transformers
81Supply onlyCeramic Bush insulators on HT side as per existing size, shape and specification for capacity 315 to 500 KVA, 11/0.433 Volts transformers
82Supply onlyCeramic Bush insulators on HT side as perexisting size, shape and specification for capacity 200 to 300 KVA, 11/0.433 Voltstransformers
83Supply onlyCeramic Bush insulators on HT side as perexisting size, shape and specification for capacity50 to 150 KVA, 11/0.433 Voltstransformers
84Supply onlybrass studon HT side as per existing size, shape and specification for capacity 315 to 500 KVA, 11/0.433 Voltstransformers
85Supply onlybrass studon HT side as per existing size, shape and specification for capacity 315 to 300 KVA, 11/0.433 Voltstransformers
86Supply onlybrass studon HT side as per existing size, shape and specification for capacity 50 to 150 KVA , 11/0.433 Volts transformers
87Supply only top cover gasket set as per existing size, shape and specification complete for capacity 1600 KVA , 33/11 KVtransformers
88Supply only top cover gasket set as per existing size, shape and specification complete for capacity 315 to 500 KVA , 11/0.433 Voltstransformers
89Supply only top cover gasket set as per existing size, shape and specification complete for capacity 200 to 300 KVA, 11/0.433 Voltstransformers
90Supply only top cover gasket set as per existing size, shape and specification complete for capacity 50 to 150 KVA, 11/0.433 Voltstransformers
91Supply only breather assembly as per existing size, shape and specification complete for capacity 1600 KVA , 33/11 KV transformers
92Supply only breather assembly as per existing size, shape and specification complete for capacity 315 to 500 KVA , 11/0.433 Voltstransformers
93Supply only breather assembly as per existing size, shape and specification complete for capacity 200 to 300 KVA, 11/0.433 Voltstransformers
94Supply only breather assembly as per existing size, shape and specification complete for capacity 50 to 150 KVA, 11/0.433 Voltstransformers
95Supply only Tap Changer as per existing size, shape and specification complete for capacity 315 to 500 KVA , 11/0.433 Voltstransformers
96Supply only Tap Changer as per existing size, shape and specification complete for capacity 200 to 300 KVA, 11/0.433 Voltstransformers
97Supply only Tap Changer as per existing size, shape and specification complete for capacity 50 to 150 KVA, 11/0.433 Voltstransformers
98Supply Only Oil temperature indication cum alarm and trip facilityas per existing size and specification complete for capacity of 1600 KVA, 33/11 KV transformers ncluding necessary connection with VCBs, complete all a s specified and directed by engr-in-charge.
99Supply Only winding temperature indication cum alarm and trip facility as per existing size and specification complete for capacity of 1600 KVA, 33/11 KV transformers including necessary connection with VCBs, complete all a s specified and directed by engr-in-charge.
100Supply and fixing of 110 Volts DC electronic Hooter of size 96X96 mm including necessary taking down of old Unserviceable one , complete all as specified and directed by engr-in-charge
101Dehydration and filtration of existingtransformer oil of transformers capacity ranging from 50 KVA to 3150 KVA( 33 KV System step down to 33/11 KV and 11 KV System step down to 11/0.433 KV)on site at different locationswithout disturbing the power supply system withfiltration machine and heating system in orderto achieve Di-electric strength of oil 40KV minimum at 2.5 mm gap complete all as specified and as directed.Note :- Contractor shall use stand by DG set for dehyderation where alternate power is not available.
102Supply &filling up of transformer oil conforming to IS -335 of 1993 as in topping up / replacementup to desired level of transformer oil capacity complete all as specified and as directed. [Note: Dielectric strength of oil should not be less than 40 KV at 2.5 mm gap complete all as specified and directed.](Make : GULF/POWER OIL/SERVO or equivalent as approved by GE)
103Supply and fixing as in replacementTemperature Guage as per existing size, shape and specification complete for capacity 350 to 500 KVA , 11/0.433 Voltstransformers
104Supply and fixing as in replacementTemperature Guage Changer as per existing size, shape and specification complete for capacity 200 to 300 KVA, 11/0.433 Voltstransformers
105Supply and fixing as in replacementTemperature Guageas per existing size, shape and specification complete for capacity 50 to 150 KVA, 11/0.433 Voltstransformers complete all as specified and directed.
106Supply and fixing as in replacementpair of arcing horns suitable fortransformer capacity50 to 500 KVA, 11/0.433 Volts complete all as specified and directed.
107Supply and replacing silica gel in crystal form of breather assembly of transformer capacity upto 3150 KVA atinstalled site complete all as specified and directed.
108M&L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles (above the Planting Depth and PCC Copings of 11.0 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one Coat of Red Oxide Zinc Chrome Primer, alternate Yellow & Black Strips Painting (4 No. Each Strip 200 mm wide) and remaining portion of Pole and Cross Arms, Cable Protection Pipe, Brackets, etc. treated with Two Coats of Aluminium Paint,complete all as specified and as directed.
109M&L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Pre-stressed Concrete Pole (above the Planting Depth and PCC Copings of 11 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying Two Coats of Synthetic Enamel Painting in alternate Yellow & Black Strips Painting (4 No. Each Strip 200 mm wide) and remaining portion of Pole treated with Two Coats of Exterior Weather Proof Paint and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. treated with Two Coats of Aluminium Paint, complete all as specified and as directed.
110Material and Labourfor Earthingcomplete with Galvanised Steel Earth Plate Electrode600 x 600 x 6mm, thick burieddirectlyin ground ( earth pit not less than 2.25 Metre deep below the Ground Level ) with Top Edge of Earth Plate not less than 1.50 Metre deep below normal ground level , connectedto Galvanisedsteel iron strip earth lead 32x6 mmbymeans of Bolts, Nuts, Check Nuts and Washers made of Galvanised Iron 20 mm dia GI Pipe (Med grade) for watering, 40 mm dia GI Pipe light grade for protection of earth strip,includingnecessary earth work in any type of soil , PCC (1:3:6) Type C1 Concrrete pit RCC (1:1.5:3) Type A1 Precast cover (54x54x5Cm) duly reinforced with including 8mm Dia TMT Bar @ 150 mm c/c both ways lifting handle made of 8mm dia TMT Bar embeded in precast cover slab complete as shown in electrical Plate No 3 of SSR Part-I including testing on completion complete all as specified and as directed.
111M & L for earthing complete with copper Earth Plate Electrode 600mm x 600mm x3.15mm, thick burieddirectlyin ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below Normal Ground Level, connectedto Copper earthstrip 20x3 mm drawn through and including Galvanised Ironprotection Pipe 40 mm bore (dia) Light grade up to heightof the transformer foundation where transformer issituated by means of Bolts, Nuts, Check Nuts and Washers etc Earth plate surrounded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150mm thick PCC Pit in cement concrete 1:3:6 (20 mm graded aggregrate ), Precast RCC1:2:4 (20mm graded aggregrate )cover slab 350 x350 x 50mm thick reinforced with and including 8mm dia TMT Bars @ 10 cmCentre to Centreboth ways GIWire Mesh , Funnel, with GI Watering Pipe 20mm bore dia Medium grade necessary excavation in soft loose soil returning filling in and removal of surplus soil upto a distance of 50 METRE and all asshown in Electrical Plate No. 3 of MES schedule Part- I and testing on completion complete all as specified and as directed.
112Servicing / Removing the existing, relay units of any make and cap from the cubical panel and carrying out servicing including cleaning, fitted, cradle contacts with Emery paper wiping gently, cleaning,and adjusting yoke, replacing burnt tripping coil etc incl calibration of IDMT relay in VCBs and tuning with other VCBs as reqd (so that incoming VCBs trips on fault before 33 KV VCB and outgoing VCBs trip before incoming VCBs) Testing of IDMT relay with the help of primary / secondary injection all as specified as per manufacturer specification.
113Servicing / Removing the existing, relay unitsof any make and cap from the cubical panel and carrying out servicing of VCBs, including cleaning, fitted, cradle contacts with Emery paper wiping gently, cleaning,and adjusting yoke, replacing burnt tripping coil etc incl calibration of IDMT relay in VCBs and tuning with other VCBs as reqd (so that incoming VCBs trips on fault before 11 KV VCB and outgoing VCBs trip before incoming VCBs) Testing of IDMT relay with the help of primary / secondary injection all as specified as per manufacturer specification.
114Supply and fix Earth continuity conductor or Main Earthing lead fixed to wall or batten or reccess or chasses or buried in ground or drawn in conduit / pipe or fixed to Poles or any other indicated situation for loop GI strip of size 32mmx6mm connected to test point complete all as specified and as directed.
115Supply and fix Earth continuity conductor or Main Earthing lead fixed to wall or batten or reccess or chasses or buried in ground or drawn in conduit / pipe or fixed to Poles or any other indicated situation for loop copperstrip of size 20mmx3m m connected to test point complete all as specified and as directed.
116M & L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by engr-in-charge.
117M&L spring charging motor for 11 KV VCB, 240 Volt, AC complete all as specified and directed complete all as specified and directed by Engr-in-charge.
118Supply and fixing spring charge gear assembly and motor in existing ABB vaccum circuit breaker including taking down old unserviceable one , complete all as specified and directed by engr-in-charge
119Supply and fixing high speed master trip relay type VAJ 110 V DCall as specified and directed by engr-in-charge
120Supply and fixing racking rack out pinion as per existing type and size, all as specified and directed by engr-in-charge
121Material and labour for earthing with copper plated earth electrode-ASEL 393 or equivalent CP-Outer pipe Dia : 80/76mm and wall thickness : 2mm ; Inner pipe dia 38mm and wall thickness 2.6mm, length : 3000 mm, copper plating thickness : 100 microns confirming to IS-3043 : 1987 all as directed & specified including HDP lockable earth pit cover cum inspection chamber & earth lead of 20 x 3 mm thick copper strip in a metallic / PVC protective covering and all other required accessories including design, modifications etc. to achieve the required earth termination rod resistance value as per OEM/Indian Standard recommendations not more than 1.0 ohm.(Note:- (i) Contractor has to produce the earth test report (ii) The rates includes the cost of excavation in any type of soil) Make :- True power Earthing
122Supply, fixingand testing of Transformer protection numerical relay REJ 601, overcurrent, earthfault, phase discontinuity, negative phase sequence and thermal overload protections, inrush current detection, reclosing and measurement preconfigured funtionality faciliates easy and fast commissioning universal power supply 24-265 V AC/DC , configure binary input/output using local HMI or communication interface specific varient with site selectable CT selection (01/05 A), boolean logic and timers, supports modbus and IEC60870-5-103 protocols,including fixing in existing position in place of thermal electromagnectic relay,complete all as specified and directed by engr-in-charge. Make :- ABB
123Supply, fixingand testing of feeder protection numerical relay REF 601, overcurrent, earthfault, phase discontinuity, negative phase sequence and thermal overload protections, inrush current detection, reclosing and measurement preconfigured funtionality faciliates easy and fast commissioning universal power supply 24-265 V AC/DC , configure binary input/output using local HMI or communication interface specific varient with site selectable CT selection (01/05 A), boolean logic and timers, supports modbus and IEC60870-5-103 protocols,including fixing in existing position in place of thermal electromagnectic relay,complete all as specified and directed by engr-in-charge. Make :- ABB
124Supply, fixingand testing of Vaccum interrupter for 11 KV VCB ,complete all as specified and directed by engr-in-charge. Make :- Altstom, Model No VG 204 GB
125Supply, fixingand testing of Vaccum interrupter for 11 KV VCB ,complete all as specified and directed by engr-in-charge. Make :- Arevaor, Model No VG2
126Servicing/ Reparingto Battery charger 10 A, 124-143V DC with battery bank of capacity 24 V, 80 AH installed at MRS and reistallation after repair & testing complete allas specified anddirected by Engr-in-Charge. Note- (a) Replacement such as rectifiers, voltage regulator, voltage limiter etc userviceable defective parts are included in unit quoted rate.
127Servicing/ Reparingto Battery charger 10 A, 110V DC with battery bank of capacity 24 V, 100 AH installed at MRS and reistallation after repair & testing complete allas specified anddirected by Engr-in-Charge. Note- (a) Replacement such as rectifiers, voltage regulator, voltage limiter etc userviceable defective parts are included in unit quoted rate.
128S&F Lightning Arrester polymer type complete with all Fittings Transmission Class discharge capacity 65 KA suitable,for working pressure 33000 Voltsincludingdismantling of old unserviceable and connection to earth Strip, complete all as specified and directed.
129S&F polymeric pin Insulator FRP 34 mm , Brown colour including one Galvanised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut,for 33 KV grade, complete all as specified and as directed

AI Tender Summary

OUR REF NO 40384511
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 95 Lakhs
LAST DATE 24-11-2023
Authority
Authority Name Military Engineer Services
Work Description Repair/ Replacement Of Ht Line, Marshelling Yard Mrs, Different 11Kv Sub Station Including Repair Of Transformer And Connected Other Works Under Ge Missamari
Basic Detail
Tender No 8394/E8
Bidding Type Tender
Location
City missamari
State Assam
Key Dates
Publish Date 27 Oct 2023
Submission Date 24 Nov 2023
Open Date 01 Dec 2023
Finance
Tender Value 95 Lakhs
Tender Fee 1000
EMD 1.67 Lakhs
Exemption Not Available
Document List
d2a45d3a-74a3-4817-9aee-5dde116847b2.html
BOQ_700028.xls
TENDERDOCUMENTS8394.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 27, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 24, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 01, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

d2a45d3a-74a3-4817-9aee-5dde116847b2.html

xls

BOQ_700028.xls

pdf

TENDERDOCUMENTS8394.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders