Tender For Repair/ Maintenance Of Summer Appliances And Geysers At Offer Qtrs, Vrg Line, Me Line, Cod Estate And Connected Area Under Ge (I) Kanpur, kanpur-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair/ Maintenance Of Summer Appliances And Geysers At Offer Qtrs, Vrg Line, Me Line, Cod Estate And Connected Area Under Ge (I) Kanpur. Submission Date for this Tender is 23-11-2023. AMC of Air Condition Tenders in kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40376709
Corrigendum : Tender For Repair/ Maintenance Of Summer Appliances And Geysers At Offer Qtrs, Vrg Line, Me Line, Cod Estate And Connected Area Under Ge (I) Kanpur
Open Tender
Indian
Uttar Pradesh
kanpur
23-11-2023

Tender Details

Tender For Repair / Maintenance Of Summer Appliances And Geysers At Offer Qtrs, Vrg Line, Me Line, Cod Estate And Connected Area Under Ge ( I ) Kanpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Nov-2023 Rvsd BOQ BOQ 16-11-2023
2 16-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 22700.0 /-
Tender Value
INR 11.35 Lakhs /-

BOQ Items

Name of Work : REPAIR/ MAINT OF SUMMER APPLIANCES AND GEYSERS AT OFFR QTRS, VRG LINE, ME LINE, COD ESTATE AND CONNECTED AREAUNDER GE (I) KANPUR
Sl. No. Item Description
1Repair, maint and making the continuity of electric supply after rectifying the defects of the ceiling fan, exhaust fan, wall fan, desert cooler, geyser, water cooler, refrigrator, ACs etc. including providioning of small pieces of electrical wire of size 0.75 to 4 Sqmm twin/three core and length not exceding 1 mtrs and all types of screws, nuts, bolts & washers as required at site complete all as specified and directed. (Note :- (i) Any other accessories found unserviceable shall be replaced & paid seprately under respective items of this Sch. (ii) Contractor will collect complaint slip on daily morning from MES complaint cell and deposit the same after rectifying the defect on next day morning(iii) Complaint slip book, registers as per sample will be provided by the contractor
2Disconnecting electrically, taking down existing ceiling/exhasut fan any type and capacity with due care, dismantling blades and removing for repair with all accessories all as spfd and directed.
3Assembling the fan any type with blades at site and hanging on ceiling /wall refixing after getting rapaired complete with all accessories all as spfd and directed.
4Strip opening of ceiling fan 230 volts any make /type/size for carrying out repair/greasing / oiling, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testingcomplete and all as specified. Note :- 1. Repairs will be measured and paid separately under respective items.
5Rewinding of ceiling fan motor 1200/1400 mmsweep any make/size with super enamelled copper winding wire with gauge including cutting of old burnt winding. Sleeve work varnishing with `B" class insulation varnish, greasing ,connection with flexible wire of appropriate size two core copper wire upto connector block qty of copper winding wire complete and all as specified.
6S&F in repair fan capacitor AC 440 volts 4 mfd 50HZ complete and all as specified. Make : Jimcap/Epcos/Havells
7All as per srl item No 6 here-in-before but 2.5 mfd and complete all as specified and directed.
8All as per srl item No 6 here-in-before but 3.15 mfd and complete all as specified and directed.
9S&F in repair ofgun metal bush suitable for any size / model / type of fans complete all as specified & directed.
10S&F in repair alignment grinding to shaft, remetalling & finishing all as required .
11S&F in repair ceiling fan shaft of standard size including taking out old shaft, complete and all as specified.
12Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed by engineer-in-charge. Make : Havells/Anchor/Indoasian
13Strip opening of exhaust fan/air circulator/table fan/Pedestal/wall fanany size / make / sweep for carry outrepair/greasing,oiling work, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing after carrying out the repair, complete and all as specified.
14Rewinding of exhaust fan/ air circulator fan/ table fan/pedestal/wall mounted fan motor any size, from 225 to 450 mm sweep with supper enamelled copper wire as required including necessary cutting of old burnt winding wire, cleaning of slots, greasing and provision of necessary threading/sleeve work and taking out connection in lead with PVC copper wire of appropriate size upto connector block complete and all as specified.
15S&F in repair of ball bearing any No suitable forceiling fan upto 1400mm sweep complete and all as specified Make : SKF/NBC/ABC.
16S&F in repair of ball bearing for exhaust fan/pedestal fan/air circulator/table/wall fan upto 450mm sweep complete and all as specified Make : SKF/NBC/ABC.
17Cleaning thoroughly ceiling fans 48"/56" (1200mm / 1400mm) sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified & directed by Engineer-in-Charge
18Cleaning thoroughly exhaust/wall/podestal fan 256 mm to 450 mm sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified & directed by Engineer-in-Charge
19S&F in repair of fan blade set steel heavy duty suitable for exhaust/ pedestal/air circulator fan 250 to 450 mm sweep, complete (as per sample) and all as directed by Engineer-in-Charge.
20S&F in repair of fan blade set plastic suitable for exhaust/ pedestal/air circulator fan 250 to 450 mm sweep, complete (as per sample) and all as directed by Engineer-in-Charge.
21S&F in replacement of fan blade set steel 1200/1400mm sweep complete (as per sample) and all as directed by Engineer-in-Charge suitable for ceiling fan all as required at site.
22S&F in replacement ofdown rod for ceiling fans made out of 15 mm diaMS pipe, medium grade duly threaded/pin complete all as per sample of size 45 Cm long.
23All as per item No 22but of size 1 Mtrs long and complete all as specified and directed.
24All as per item No 22but of size 1.5 Mtrs long and complete all as specified and directed.
25All as per item No 22 but of size 2 Mtrs long and complete all as specified and directed.
26All as per item No 22 but of size 3 Mtrs long and complete all as specified and directed.
27Disconneting & taking down ceiling fan up to 1400 mm sweep / exhaust fan up to 450mm sweep for servicing, strip opening of fan including servicing, cleaning, oiling and greasing complete at site. Re-assembling and refixing to the same/other location. Testing complete after servicing and fixing for smooth and noise free operation.
28Supply and fixing lower and upper canopy of fans of ceiling fans of suitable size required at site as directed by Engr-in-Charge.
29S&F in repair for 40 mm bore galvanised iron tubing medium grade fixed to walls for hanging the fan complete all as specified and directed.
30S&F in repair for 50 mm bore galvanised iron tubing medium grade fixed to walls for hanging the fan complete all as specified and directed.
31S&F of hook for hanging of fan on ceiling of suitable shape of mild steel flat iron with suitable size nuts, bolts & washers all as per sample complete all as specified & directed.
32M & L for providing PVC rounded 3 core 0.75 sqmm copper cable and making necessary connection complete all as specified & directed. Make : Polycab / Finolex / Havells/Plaza.
33All as per item No 32 but copper cable of size 1.5 Sqmm.
34All as per item No 32 but copper cable of size 2.5 Sqmm.
35M&L for single pole and neutral enclousere with a top pin, plug and socket copmlete with one MCB 25 Amps, 240 Volts.
36S&F in repair of plug top 15 Amps all as spfd and directed. Make : Cona/Anchor/Havells
37Taking out water cooler of any make and type of capacity 40 / 80 / 150 ltrs from position and cleaning/serviceing the complete condenser coil and storage tank with chemical base solution and soda water including servicing, oiling of air blower motor, checking of electrical & water supply connection incl and re-fixing the same on its existing position after testing complete all as specified and directed.
38Disconnecting, dismantling and taking out defective water cooler of any make and type of capacity 40 / 80 / 150 ltrsfor repair all as spfd and directed.
39S&F repairin replacement ofsealed compressor as per sample suitable for water cooler of capacity up to 40 / 80/ 150 Ltrsas per sample.
40S&F repair in replacement of Starting capacitor 40-60 Mfd / 60-80 Mfd / 80-100 Mfd as per sample for water cooler.
41S&F repairin replacement of Running capacitor 10-30 Mfd as per sample for water coller/ window ac/ split ac/refrigerator.
42S&F repair in replacement of Thermostat suitable for water cooler of capacity 40 / 80 / 150 ltrs as per sample.
43S&F repair in replacement ofStarting relay of water cooler as per compressor requirement.
44S&F repair in replacement of Blower motor of water cooler with fan blade of capacity 1/10 to 1/35 HP as per site requirement.
45S&F repairin replacement ofOver load protector of water cooler as per sample suitable for water coolers.
46S&F in repair of PVC flexible pipe transparent 15 / 20 mm dia (as per sample) for water cooler.
47S&F in replacement ofBrass chromium plated Push cock heavy duty universal type, suitable for water cooler of capacity up to 150 ltrs.
48S&F in repair of PVC float valve 15 / 20 mm dia with rod & ball for water cooler. Make: Prayag or equivalent.
49S&F in repair of Liquid line filter one way / two way for water cooler.
50Supply and fixing in repair of waste washing tray including PVC pipe connection of existing shape & size for water cooler as required at site complete all as specified and directed.
51S & F in repair of condenser coil with copper tube and aluminium fins for water coolers suitable for up to 40 / 80/ 150 Ltrs capacity of any make and type complete all as specified and directed.
52M & L repair for cutting out worn bottom and sheet base frame including mild steel legs from water coolers of any make and capacity and fixing the same with new plain galvanised iron sheet 16 SWG of existing size and new angle iron base frame and legs of existing size with and including necessary gas welding and providing nuts / bolts etc complete all as specified and directed.
53S&F repair of ceiling fan clamps for fixing with fan rod incd nut, bolt, lock pin, rubber real complete all as specified & directed.
54M & L for Writing SM / MES No. of Summer cooling appliances including Water coolers, desert coolers, refrigerators and Air Conditioners with synthetic enamel paint or Stickers equivalent of approved color complete all as specified and directed by Engr-in-Charge.
55Supply & Fixing in replecement Exhaust fan iron body 200/250 mm sweep complete with fittings & connections to wall complete all as per directed by Engr-in-charge
56M & L in repair for taking down/out desert cooler from exsting place and removing the old paint from the body of desert coolerand applying paint external body, fan and pump with a coat of synthetic enamel grey paint , internal body with a coat of synthetic enamel black paint with brush painting at site after proper dusting cleaning and scraping old painted surface and refixing on same/other location after painting complete all as specified and directed.
57M & L in repair of side panels of desert cooler made out of 22 SWG mild steel sheet of size not more than 0.70x0.80 mtr to match with existing cooler as per sample complete with jalli, wood wool pad , fastners painting with two coat of synthetic enamel paint over a coat of primer etc complete all as specified and directed.
58M&L inrepair of desert cooler water tank made out of 19 SWG mild steel sheet of size not more than 0.80x0.80x0.20 mtr (approx)to match with existing cooler as per sample including front side panel opening complete with louvers, provision for selector switch, indicator lamp etc and top cover plate made of 22 SWG mild steel along with vertical angle support of suitable height and two coat of synthetic enamel paint over a coat of primer etc complete all as specified and directed.
59Supply and fixing in repair of water lifting pump submersible type 220 -240 Volts 50 HZ as per sample complete all as specified and directed.
60Supply & fixing in repair of kit fan motor of desert cooler as per sample, 230 volts complete with blades, fixing legs, nuts, bolts, washers etc of complete all as specified & directed. Make : Crompton / Havells / Khaitan / Usha.
61S&F in replacement of ready made wood wool pad size as required at site of 15 mm thickness, made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as specified & directed.
62M & L for disconnecting, dismantling, refixing and rewinding of kit fan motor upto450 mm sweep of desert coolers 230 volts AC 50 C/S with super enamelled copper conductor wire of existing gauge as original including replacement of bush -02 Nos shaft -01 No ring-01 No & clamp-04 Nos complete all as specified & directed
63S & F in repair of desert cooler stand using angle iron (40 x 40 x 6 mm) making square type platform of min size 800 x 800mm and fixing through two angle iron piece for horizontal support and two angle iron piece for 45 degree angle vertical support into the walls of any type / height as required on site by means of required nuts, bolts, fastners, welding work etc to form a platform suitable for fixing the desert cooler of any size & type compete all as specified and directed. Note: Angle iron should be painted with a coat of red oxide primer and two coat of synthetic enamel paint.Minimum 20 cm length of the angle iron should be inserted into the wall and fixing the same through required PCC work.Cutting chases in walls required for fixing the angle iron support shall be finished with cement mortar 1:4 and surface shall be matched with existing surface by using putty, plaster of paris etc. and applying finishing coat of existing treatment shall be deemed to be included in the unit rate quoted by the contractor.
64M&L in repair for dimentling, taking out old u/s clamp and fixing with new clamp for kit fan motor of desert cooler as per site requirement with nuts & washers complete all as spfd and directed..
65Disconnecting, dismantling old u/s selector switch and fixing with new selector switch as per sample all as spfd and directed. Make Anchor/Kay/Cona
66Disconnecting, dismantling old u/s indicator lamps and replaced with new all as spfd and directed. Make Anchor/Kay/Standard
67Dismantling old PVC Water distributor four way and refixing with new as per sample and all as spfd and directed.
68S&F in repair of existing UNSV desert cooler blade as per sample and fix in the desert cooler and all as specified and directed by Engr-in-Charge. Make. Cromton graves.
69M&L for disconnecting, dismantling old u/s wiring of desert cooler and replacement with new wiring of selector switches and indication lamps and other as required at site with 1.5 Sqmm single core wires all as spfd and directed.
70Disconnecting, dismantling and taking out old u/s storage type water heater geyser of cap 25/35 Ltrs from wall for repair at site all as spfd and directed.
71Fixing only storage type water heater geyser on wall after reapir and replacement of old unserviceable with gutties/anchor bolts or nuts & bolts and fixing the same in existing /other location complete all as specified and directed.
72M&L for opening the geyser and replacement of glass wool for insulation of geyser of 25 to 50 ltrs capacity of anymake / type complete all as specified and directed by Engineer-in-Charge.
73S&F in repair of chromium plated flexible stainless steelconnection with two brass adopter as per existing sample suitable for carrying hot / cold water, fixed one end at geyser inlet and other to outlet water supply point complete all as specified and directed.
74S&F in repair of PVC flexible connection with two brass adopter as per existing sample suitable for carrying hot / cold water, fixed one end at geyser inlet and other to outlet water supply point complete all as specified and directed.
75M&L for disconnecting, dismantling old u/s thermostat switch of geyser 25 to 50 ltrs capacity and replaced with new as per sample with temperature range adjustable from 25 to 90 degree centigrade, superior quality 20 Amps rating, 220 Volts AC supply as per sample complete all as specified and directed.
76M&L for disconnecting, dismantling old u/s heating element of cap 2 kW and replaced with new and testing on completion as per sample complete all as specified and directed by Engineer-in-Charge
77All as per item No 57 but heating element of size 1.5 kW.
78M&L for dismantling old u/s syphon assembly of geyser 25 to 50 ltrs ltr capacity and replaced with new stainless steel syphon as per sample and all as spfd and directed/
79S&F in repair of pressure release valve with inlet coupling of superior quality as approved complete all as specified and directed by Engineer-in-Charge.
80S&F in repair of plug top 15 Amps all as spfd and directed. Make : Cona/Anchor/Havells
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail