Tender For Repair / Maintenance Replacement Of Street Lights, Perimeter Lights, Street Light Timers With Allied Work In Technical Area And Officer Enclave Area Under Age (I) Af Stn Manauri
Tender Overview
Project Description
Tender For Repair / Maintenance Replacement Of Street Lights, Perimeter Lights, Street Light Timers With Allied Work In Technical Area And Officer Enclave Area Under Age (I) Af Stn Manauri
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-Nov-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-Nov-2023 |
| 2 | 23-Nov-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 28-Nov-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches soft/loose soil not exceeding 1.5 m wide not exceeding 1.5 m in depth for foundation etc or for shaft well, cesspits, manholes, pirehole etc not exc 10sqmm on plan and not exceeding 1.5 m in depth and getting out complete all as specified & directed. |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified & directed. |
| 3 | Removing excavated material not exceeding 50 m and deposting where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed. |
| 4 | M&L for sand cushioning (dry sand) to under ground cable for cable protection complete all as specified & directed.Note: Only punned thickness of sand will be measured. |
| 5 | M&L for brick, subclass \"B\" well burnt, laid dry flat in trenches for protection of cable over LT cable, complete all as specified & directed. |
| 6 | Labour for boring under road/drain/PCC path by mannual method for inserting the 40/50mm dia light grade GI tubing for cable protection complete all as specified & directed. |
| 7 | S&F in replacement 50mm dia GI tubing (light grade) fixed on each pole, with suitable size MS clamp 4 mm thick 15cm width, two nos nut and bolts holding the steel tubular pole with painting of MS strip clamp complete all as specified & directed. |
| 8 | M&L cement concrete in roof, kerbs or mud stops rounded or chamfered on edge type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) complete all as specified & directed. |
| 9 | Labour only with necessary T&P such as tool kit/ ladderto attend day to daysecurity light/Flood light related works and repair / replacement of the unserviceable spares such as driver control plate/Fuse assembly /cable from fittings to junction box/ GI pipe bracket/clamps/ kiosk box all other required work for making serviceable to security light fitting etc all street light poles 9 /11 mtr long, carried out all complaints secure safety measures complete all as specified & directed. Note : (i) All required spare parts for making serviceable shall be measured and paid seprately. (ii)Making serviceable one security light will be consider as single job. |
| 10 | Supply, laying, testing and connection of UG LT PVC insulated armoured heavy duty electric XLPE cable with aluminium conductor 1100 volt grade 3.5 core, cross-sectional area 25 Sqmm size in treanches including cutting, providing aluminium lugs suitable size and cable glands and nut bolts etc with electrical connection in terminal box and testing and commissioning including taking out old unserviceable cable complete all as specified & directed.Make: Havells/ Finolex/ RPG/ Polycab/ Paragon/ Fort Gloster |
| 11 | Supply, laying, testing and connection of UG LT ,PVC insulated armoured heavy duty electric XLPE cables with aluminium conductor 1100volt grade 2 core, cross-sectional area 10 Sqmm size in treanches including cutting, providing aluminium lugs suitable size and cable glands and nut bolts etc with electrical connection in terminal box and testing and commissioning including taking out old unserviceable cable complete all as specified & directed.Make:Havells/ Finolex/ RPG/ Polycab/ Paragon/ Fort Gloster |
| 12 | S&F in replacement MCCB 4 Pole 63 Amp having breaking capacity 25kA at 415V with adjustable thermal & fixed magnetic setting (A Frame) Ics=100% of Icu including making connection with suitable size lugs complete all as specified & directed.Make : L&T / Havells / Siemens / Schneider |
| 13 | S&F in replacement MCCB 4 Pole 100 Amp having breaking capacity 25kA at 415v with adjustable thermal & fixed magnetic setting (A Frame) Ics=100% of Icu including making connection with suitable size lugs complete all as specified & directed.Make :L&T / Havells / Siemens / Schneider |
| 14 | S&Fin replacement of CE 60 watt LED street light fitting with pressure die cast aluminium housing with heat resistant toughened glass and accessories & IP66 protection,White cool,Raptor Neo, metal, input Voltage 220 V includingmaking connection complete from fitting to pole/terminal box, complete all as specified & directed.Make: Crompton Cat part No TRP409-60-57-SL-NS-GL-NSG / Havells Cat Part No LHETBXU7PA6J060/ Bajaj / Phillips |
| 15 | S&Fin replacement of CE 120 Watt Flood light fitting with pressure die cast aluminium housing with heat resistant toughened glass and accessories & IP66 protection,White cool,, metal, input Voltage 220 V includingmaking connection complete from fitting to pole/terminal box complete all as specified & directed.Make: Crompton (Cat Part No LFLN-120-CDL/60-M) / Havells / Bajaj / Phillips |
| 16 | S&Fin replacement of CE 200 Watt Flood light fitting with pressure die cast aluminium housing with heat resistant toughened glass and accessories & IP66 protection,White cool,, metal, input Voltage 220 V includingmaking connection complete from fitting to pole/terminal box complete all as specified & directed.Make: Crompton (Cat Part No LFLN-200-CDL/60-M)/ Havells / Bajaj / Phillips |
| 17 | Supply only in replacement Driver circuit plate of LED security light fitting capacity 25 to 60 Watt in original suitable for Make / model as existing and as approved by Engr-in-Charge complete all as specified & directed. |
| 18 | Supply only in replacement Driver circuit plate of LED security light fitting capacity 70 to 120 Watt in original suitable for Make / model as existing and as approved by Engr-in-Charge complete all as specified & directed. |
| 19 | Supply only in replacement Driver circuit plate of LED security light fitting capacity 150 to 200 Watt in original suitable for Make / model as existing and as approved by Engr-in-Charge complete all as specified & directed. |
| 20 | S&Fin replacement of twin core copper flexible wire, PVC insulated and PVC sheathed 1.5 Sqmm size from street light fitting to terminal box length electric connection through suitable size lugs (in the steel tubular pole making two hole one near terminal box and one near street light fitting, holesize 5.0Sqmm, making of hole drilling method and wire connection through inner side of pole) including commissioning and testing and also taking down the old flexible wire from overhead conductor to fitting complete all as specified & directed. |
| 21 | S&Fin replacement of shock proof, fire retardant rust proof, out door pole kiosk box of size 310x210x120mm made out of one piece Engineer plastic moulding of siemens grey colour with in built 4 aluminium strip of 100Amp rating fitted on DMC unbrakable insulator with MCB SPN 40Amp including clamps for fixing arrangement complete all as specified & directed.Make: Sintex / Universal / SMC |
| 22 | S&F in replacement three pole power contactor type ML-4 suitable for 70-100 amp range, 240 volt including making connection complete all as specified & directed.Make: L&T Model-SS90910 / ABB / Siemens / C&S |
| 23 | S&F in replacement three polepower contactor type MNX suitable for 32-60 amp range, 230/415 volt including 1 no with NO volt coil, making connection complete all as specified & directed.Make: L&T Model-CS94111 / ABB / Siemens / C&S |
| 24 | S&F inreplacement three polepower contactor type MNX suitable for 9-35 amp range, 230/415 volt including one 1 with NO volt coil,making connection complete all as specified & directed.Make: L&T Model-CS94106 / ABB / Siemens / C&S |
| 25 | S&F in replacement timer switch (FM series) suitable for 16A/250 V AC supply, FM/1 quartz daily 240V AC base/din mounting including making connection complete all as specified & directed.Make: L&T Model- J648B1 / Legrand / C&S |
| 26 | Lowering down high mast lantern carriage from 16 to 20 meter high mast pole and raising it after changing the MV light fittings with LED light fittings and testing the automation system for moving up-down the above said lantern carriage complete all as specified & directed. |
| 27 | M&L for servicing of integral power tool of High mast sytem insatlled for it\"s operation, repairing of control panel circuit, Motor etc for safe operation of mast including necessary oiling, greasing etc and changing of minor defective items installed in control panel, testing after servicing/repairing on complete installation of parts for mast operation complete all as specified & directed. |
| 28 | M&L for GI pipe brackets made out of 32/40 mm dia GI pipe medium grade 1.5m long, bent to shape, including necessary cutting, welding etc and fixing the same with two number flat iron clamps of 40x4mm with nuts, bolts and washer including taking down old brackets complete all as specified & directed. |
| 29 | M&L for preparation of old painted surface of PCC LT Poles / Steel LT poles and applying two coats of synthetic enamel paint in alternate blue and white strips of 30 cm each up to 1.5 m height from top of steel/PCC coping and numbering of poles complete all as specified & directed. |
| 30 | S&F in replacement Digital timer switch with Timelite DBs outdoor type factory made powder coated all along internal and external surfaces, weather proof dust/water proof with IP 55 protction, consisting of 01 No AC contactor three phase 32 Amp capacity 25 kA, one digital Timer switch three nos MCB 32Amp 10 kA toggle switch having both auto manual and by pass system - 01 No mounted on existing pole/panel with suitable size clamps complete all as specified & directed. Make: Indoasian model Digital time lite switch 32 amp 3 pole Cat No TL032DBO and digital time DB Cat Part No TDA43110 / Schneider / Legrand / Havells / L&T |
| 31 | S&F in replacement manual operated ON/ OFF switch for security light circuit 230 volt AC supply upto 40 Amps rated in existed complete all as specified & directed. |
| 32 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix \"B\" to Particular specifications as approved by AGE (I) AF manauri if not specified in BOQ |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender