Bids Are Invited For 12C X2.5 Sqmm Multistrand Trailing Cable For Eot Crane Application Multi Core -Unarmoured, Flexible ( Class-5 ) Annealed Tinned Copper Conductor, Core Dia Of Strand ( Before Stranding ) ( Mm ) :0.25, Conductor Ref Standard:As Per Is 8130 / 1984, Extruded Epr Insulated With Number Printing, Insulation Thickness ( Min ) ( Mm ) :0.8, Such Cores Laid Up, Extruded Pcp Rubber Inner Sheathed, Inner Sheath Thickness ( Minimum ) ( Mm ) :1.4, Nylon Open Type Braided, Extruded Pcp Rubber Outer Sheathed, Outer Sheath Thickness ( Min ) ( Mm ) :1.56, 1100V V Grade, Trailing Cable Generally Confirming To Is-9968. Sequential Marking For Every Meter. *Unit Of Measurement: Meter 19C X2.5 Sqmm Multistrand Trailing Cable For Eot Crane Application Multi Core -Unarmoured, Flexible ( Class-5 ) Annealed Tinned Copper Conductor, Core Dia Of Strand ( Before Stranding ) ( Mm ) :0.25, Conductor Ref Standard:As Per Is 8130 / 1984, Extruded Epr Insulated With Number Printing, Insulation Thickness ( Min ) ( Mm ) :0.8, Such Cores Laid Up, Extruded Pcp Rubber Inner Sheathed, Inner Sheath Thickness ( Minimum ) ( Mm ) :1.6, Nylon Open Type Braided, Extruded Pcp Rubber Outer Sheathed, Outer Sheath Thickness ( Min ) ( Mm ) :1.8, 1100V Grade, Trailing Cable Generally Confirming To Is-9968. Sequential Marking For Every Meter. *Unit Of Measurement: Meter 120 Sqmm Multistrand Single Core Silicon Rubber Insulated Flexible Copper Cable With Glass Fibre Sheathed For High Temp Application In Ht Motor Terminals. Flexible ( Class-6 ) Annealed Bare Copper Conductor, Core Dia Of Strand ( Before Stranding ) ( Mm ) :0.31, Semi Conductive Tape Over Conductor, Extruded Silicon Rubber Insulated, Insulation Thickness ( Min ) ( Mm ) :2.15, Fiber Glass Yarn With Varnish Braided With 100.00% Coverage, Braided, 7.2Kv Voltage Grade, Hv Test Core To Water:15Kv For 1 Minute, Sequential Marking For Every Meter. 150 Sqmm Multistrand Single Core Silicon Rubber Insulated Flexible Copper Cable With Glass Fibre Sheathed For High Temp Application In Ht Motor Terminals. Flexible ( Class-6 ) Annealed Bare Copper Conductor, Core Dia Of Strand ( Before Stranding ) ( Mm ) :0.31, Semi Conductive Tape Over Conductor, Extruded Silicon Rubber Insulated, Insulation Thickness ( Min ) ( Mm ) :2.15, Fiber Glass Yarn With Varnish Braided With 100.00% Coverage, Braided, 7.2Kv Voltage Grade, Hv Test Core To Water:15Kv For 1 Minute, Sequential Marking For Every Mete 25Sq.Mm ( 196 / 0.4Mm ) , 1.1Kv Grade Flexible Single Core Copper Cable With Annealed Tinned Copper Conductor Of Class-5 Conforming To Is:8130 / 84; With Black Coloured Silicon Rubber Insulation; Fibre Glass Yarn Braided And Treated With Suitable Varnish And Conforming To Is:9968 / Part-I, No.Of Strands:196; Dia Of Each Strand:0.4Mm;Insulation Thickness ( Min ) :1.16Mm; Dia Over Braiding:10.3+ / -2Mm. 50Sq.Mm ( 396 / 0.4Mm ) , 1.1Kv Grade Flexible Single Core Copper Cable With Annealed Tinned Copper Conductor Of Class-5 Conforming To Is:8130 / 84; With Black Coloured Silicon Rubber Insulation; Fibre Glass Yarn Braided And Treated With Suitable Varnish And Conforming To Is:9968 / Part-I, No.Of Strands:396; Dia Of Each Strand:0.4Mm;Insulation Thickness ( Min ) :1.34Mm; Dia Over Braiding:13.4+ / -2Mm. 95 Sqmm ( 456 / 0.5Mm ) Multistrand Single Core Flexible Copper Cable. Flexible ( Class-5 ) Annealed Bare Copper Conductor, Core Dia Of Strand ( Before Stranding ) ( Mm ) :0.5, Core No Of Strands Min:456, Conductor Ref Standard:As Per Is 8130 / 1984, Spirally Wrapped & Fused Ptfe Insulated, Insulation Thickness ( Min ) ( Mm ) :0.6, Class F Isulation, Fiber Glass Yarn With Varnish Braided With 100.00% Coverage, 1100V Grade, Cable Confirming To Generally Confirming To Jss 51034. 120 Sqmm ( 570 / 0.5Mm ) Multistrand Single Core Flexible Copper Cable. Flexible ( Class-5 ) Annealed Bare Copper Conductor, Core Dia Of Strand ( Before Stranding ) ( Mm ) :0.5, Core No Of Strands Min:570, Conductor Ref Standard:As Per Is 8130 / 1984, Spirally Wrapped & Fused Ptfe Insulated, Insulation Thickness ( Min ) ( Mm ) :0.6, Class F Isulation, Fiber Glass Yarn With Varnish Braided With 100.00% Coverage, 1100V V Grade, Cable Confirming To Generally Confirming To Jss 51034. 4C X6 Sqmm Multistrand Trailing Cable For Eot Crane Application Multi Core -Unarmoured, Flexible ( Class-5 ) Annealed Tinned Copper Conductor, Core Dia Of Strand ( Before Stranding ) ( Mm ) :0.3, Conductor Ref Standard:As Per Is 8130 / 1984, Extruded Epr Insulated With Number Printing, Insulation Thickness ( Min ) ( Mm ) :0.8, Such Cores Laid Up, Extruded Pcp Rubber Inner Sheathed, Inner Sheath Thickness ( Minimum ) ( Mm ) :1.2, Nylon Open Type Braided, Extruded Pcp Rubber Outer Sheathed, Outer Sheath Thickness ( Min ) ( Mm ) :1.4, 1100V V Grade, Trailing Cable Generally Confirming To Is-9968. Sequential Marking For Every Meter. 1.1Kv, 1.5Sq.Mm Unarmoured Varnished Fibre Glass Yarn Braided Single Core Cable With Flexible Annealed Copper Conductor Conductor Size:1.5Sq.Mm; Dia Of Each Strand:0.25Mm; Dia Over Braiding:2.6+ / -1Mm;Insulation Class:F 1.1Kv, 2.5Sq.Mm Unarmoured Varnished Fibre Glass Yarn Braided Single Core Cable With Flexible Annealed Copper Conductor Conductor Size:2.5Sq.Mm; Dia Of Each Strand:0.25Mm; Dia Over Braiding:3.1+ / -1Mm; Insulation Class:F 1.1Kv, 4Sq.Mm Unarmoured Varnished Fibre Glass Yarn Braided Single Core Cable With Flexible Annealed Copper Conductor Conductor Size:4Sq.Mm; Dia Of Each Strand:0.31Mm; Dia Over Braiding:3.6+ / -1Mm; Insulation Class:F 1100 Volt Grade, 3.5X 50 Sq Mm L.T Armoured Power Cable With Stranded Aluminium Conductor , Pvc Insulated ( Type-A ) Colour Coded, Laid Up, With Filler Provided With Extruded Pvc Inner Sheath , Single Galvanised Steel Round Wire Armoured And Provided With Pvc Outer Sheath.Both Inner And Outer Sheaths Shall Be Of Type St-1 And Cable Shall Be Conforming To Is:1554 ( Part-1 ) / 1988. Nb-Unless Otherwise Specified Else Where In This Specification, The Rating As Well As Performance And Testing Of The Cable Shall Conform To The Latest Revisions Available At The Time Of Placement Of Order As Per All The Relevent Standards As Mentioned But Not Limited To The Above . Sequential Marking-The Following Particulars Shall Be Properly Legible On The Cable Sheath At Interval Of One Meter Through Out The Length Of The Cable. Manufactures Name, Voltage Grade Year Of Manufacture, Nalco, Successive Length, Size Of Cable, Isi Mark Packing- Cable Shall Be Supplied In Standard Length Of 500 Mtrs With + / - 5% Tolerance In A Non Returnable Wooden / Plastic Drum. The Cable Drum Shall Carry The Following Information- Length Of Cable, Type Of Cable And Voltage Grade, Size Of Cable, Year Of Manufacture. Type Test And Routine Test Certificate To Be Submitted By The Party Along With The Material . Standard Warranty -The Cable Shall Be Warrented For A Period Of 18 Months Against Any Manufacturing Defect. Total Quantity : 3200