Tender For Provision Of 05 X Urinal Point Near Bldg No. T-48 And Additional /Alternator To Bldg Nos P-22 And P-24 Of Md Accn At Mil Stn Banbasa, banbasa-Uttarakhand

Military Engineer Services-MES has published Tender For Provision Of 05 X Urinal Point Near Bldg No. T-48 And Additional /Alternator To Bldg Nos P-22 And P-24 Of Md Accn At Mil Stn Banbasa. Submission Date for this Tender is 28-11-2023. Toilet Bathroom Tenders in banbasa Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

40355888
Corrigendum : Tender For Provision Of 05 X Urinal Point Near Bldg No. T-48 And Additional /Alternator To Bldg Nos P-22 And P-24 Of Md Accn At Mil Stn Banbasa
Open Tender
Indian
Uttarakhand
banbasa
28-11-2023

Tender Details

Tender For Provision Of 05 X Urinal Point Near Bldg No. T-48 And additional /alternator To Bldg Nos P-22 And P-24 Of Md Accn At Mil Stn Banbasa

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-11-2023
2 23-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 92000.0 /-
Tender Value
INR 46 Lakhs /-

BOQ Items

NAME OF WORK: PROVN OF 05 X URINAL POINT NEAR BLDG No. T-48 AND ADDN AND ALTN TO BLDG Nos P-22 AND P-24 OF MD ACCN AT MIL STN BANBASA
Sl. No. Item Description
1DESCRIPTION OF ITEMS
2Demolition of cement concrete unreinforced in any description and in any position removal of debris from site all as specified and directed.
3M & L for 75mm thick cement concrete type C2 (1:3:6) using 40mm graded stone aggregate for plinth protection, path etc finished surface even and smooth without using extra cement all as specified and directed.
4Demolition of brick work built in cement mortar all as specified and directed.
5M & L for brick work built in CM (1:6) with old sized sub class B burnt clay bricks straight or curved on plan exceeding 6m radius all as specified and directed.
6Taking down cement plaster of any description in any position including raking out joints making for key, scrubbing down with water etc and removal of debris from site all as specified and directed.
7M & L for 15mm thick rendering in CM(1:4) on fair faces of brick walls and finishing the surface even and smooth with out using extra cement complete all as specified and directed.
8M & L for 15mm thick rendering in CM(1:6) on other than fair faces of brick walls and finishing the surface even and and smooth with out using extra cement complete all as specified.
9M & L for 5mm thick rendering in CM(1:3) on ceiling and finishing the surface even and smooth with out using extra cement all as specified and directed.
10M & L for preparation of newly plastered surfaces of ceiling and applying two coats of oil emulsion distemper of white or tinted, over & including a layer of wall care putty (average thickness 1mm) finished smooth, complete all as specified and directed.
11M & L for preparation of old plastered surfaces of ceiling by complete removal of existing treatment by brooming down or steel wire brushing, moulds, moss and efflorescent salts etc and applying two coats of oil emulsion distemper of white or tinted, over & including a layer of wall care putty (average thickness 1mm) finished smooth, complete all as specified and directed.
12M & L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer over & including a layer of exterior grade wall care putty (average thickness 1mm) finished smooth complete all as specified and directed.
13M & L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper of white or tinted, over & including a layer of wall care putty (average thickness 1mm) finished smooth, complete all as specified and directed.
14M & L for preparation of old plastered surfaces of walls by complete removal of existing treatment by brooming down or steel wire brushing, moulds, moss and efflorescent salts etc and applying two coats of oil emulsion distemper of white or tinted, over & including a layer of wall care putty (average thickness 1mm) finished smooth, complete all as specified and directed.
15M & L for preparing the new surfaces of walls and applying three coats of white wash on complete all as specified and directed.
16Dismantling floor hearth, wall tiling including cement mortar bedding, backing complete all as specified and directed.
17M & L for non-skid ceramic coloured floor tiles exc 0.11sqm but not exc. 0.18sqm as in floors set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade over and including 15mm thick screed bed in CM(1:6) complete all as specified and directed.
18M & L for non-skid ceramic coloured floor tiles exc 0.11sqm but not exc. 0.18sqm as in skirting/dado set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade over and including 10mm thick rendering in CM(1:4) complete all as specified and directed.
19M & L for glazed ceramic coloured wall tiles 300x450x7 to 8mm thick as in vertical surface such as skirting/dado tiles set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade over and including 10mm thick rendering in CM(1:4) complete all as specified and directed.
20M & L for machine cut Kota stone slab flooring 20-25mm thick over and including 15 mm thick screed bed in CM (1:6) laid and bedded jointed in cement slurry mixed with pigment to match to shade of the slab incuding grinding, mirror polishing complete all as specified and directed.
21M & L machine Cut Kota stone slab 20-25mm thick as in dado, riser of steps, skirting, and including 10 mm thick rendering as backing coat of kota stone CM 1:4laid and jointed with grey cement slurry mixed with pigment to match to shade of the slab incuding cutting grinding mirror polishing complete all as specified and directed.
22M & L forUdaipur green marble work 12 to 15mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match, over and including 15mm thick screed in CM(1:4) including making hole 25 mm dia for gas pipe (if required) complete all as specified and as directed by Engineer-in-Charge.
23M & L for providing edge moulding to 18-20mm thick stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc complete all as specified and as directed by Engineer-in-Charge.
24Taking down chowkats or frames with shutter(without taking off shutter from the frame) area not exc. 1.5 sqmand making the surface of brick wall good plastering, around the opening complete all as specified and directed
25Takingdown chowkats of any description without taking off shutter from the frame exceeding 1.5 sqm but not exc. 4.0 sqm each and making the surface of brick wall good plastering, around the openingcomplete all as specified and directed.
26S & F of pressed steel frames frame size 125X60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
27S & F of pressed steel frames frame size 105X60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
28S & F Mild steel Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps and similar small articles conforming to Fe 410-O 0r Fe 310-O complete all as specified and directed.
29M & L for framed work as in grills, gratings etc. with ends of bars shouldered and / or rivetted, or forged into spikes; framed guard bars; barred iron door, railings and similar work conforming to Fe 290-0 or Fe 310-0, complete all as specified and directed.
30M & L for plain cement concrete type C-1 (1:3:6) using 20mm graded stone aggregate for embedding of holdfasts and filling of pressed steel frames/chowkhats etc complete all as specified and directed.
31S & F 30mm thick flush shutters, factory made, solid core construction, with block board core and plywood face panels, commercial type on both sides including 30x6mm thick teak wood lipping around the shutter, complete all as specified and directed.
32S & F 35mm thick second class hard wood, factory made glazed and skeleton door shutter open rebated and prepared to receive glass or gauge etc (without sash bar)edges of framing plain chamfered or rounded, mitred and rebated sash bars any number complete all as specified and as directed. Note :- Size of member of shutters shall be as specified in SSR Part-I 2009 section 8 clause 8.24(a).
33S & F of mild steel butt hinges 100mm, medium weight all as specified and directed.
34S & F 150mm long ISI marked mild steel pressed handle, ovaltype, stove enamelled black complete all as specified and directed.
35S & F 200mm long ISI marked mild steel barrel tower bolts, stove enamelled black with bright bolts and fixed complete all as specified and directed.
36S & F of mild steel sliding door bolts 300mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
37S & F of 300mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
38S & F of Stainless Steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and direceted.
39S&F factory made PVC Cupboard frame of the size 75mm x 40mm with a wall thickness of 5mm, made out of extruded 5mm thick plain/prelam PVC sheet of density 600 kg/cbm, having bottom width of 50mm and thickness of 10mm. All four frame lengths reinforced with 15 mm x 15mm M. S. square tubes of 19 gauge thickness throughout the frame and mitre cut at two corners adjointed with 2 nos. of 15mm long brackets 0f 10mm x10mm M S square tubes. The door frame shall be fixed to the wall using 8/100 long M S screws through the frame by using PVC fasteners. A minimum of 4 nos. of screws to be provided for each vertical member and minimum of 2nos. of screws to be provided horizontal member etc. complete as per direction of Engr-in-Charge, manufacturer"s specification and drawing. Note :Material will be of Rajshree/ Sintex/ Cactus and will be fabricated through authorised fabricators of the approved firm.
40S&F factory made PVC cupboard flush type shutter (to form double leaf door) of 30mm thick consisting of frame made out M S tubes of 19 gauge thickness and size 19mm x 19mm for stiles and rails. The inside panel shall consist of 20 mm thick multichamber hollow PVC section of 1mm wall thickness, bonded using solvent cement/ cynoacrylate adhesive with 5mm thick plain/prelam PVC sheet, on both side of inside panel incliding necessary items to fix the shuter to frame such as 100mm stailess steel hinges, 100 mm long handles made of anodised aluminium and magnetic ball catch for each pair of shutter.All four edges of the panel to be sealed with lipping of 10mm thick and 20mm wide PVC sheet baton (made by sticking 2nos. PVC foam sheet of 5mm thickness using PVC solvent cement adhesive) complete as per direction of Engr-in-Charge. Note : ( Material will be of Rajshree/ Sintex/ Cactus and will be fabricated through authorised fabricators of the approved firm)
41S&F factory made PVC shelf/ Partition of required size consisting of panel of 18mm thick Celuka PVC ply and for supporting the hold of shelf/ Partition and shall provided 3 edges in size 18mm x 18mm as per required length. The front side of the edge visible in the front of the shelf/ Partition to be edge lipped by 18mm width x 1mm thick PVC sheet using solvent cement etc including dismantling of existing partition/shelf of any description etc complete as per direction of Engr-in-Charge. Note :- ( Material will be of Rajshree/ Sintex/ Cactus and will be fabricated through authorised fabricators of the approved firm)
42S&F PVC sheet wall panelling of thickness 5mm consisting panels of desired size stuck on inner frame work of 35mm wide strips of 5mm thick PVC sheet. The PVC strips shall be fixed to the wall using 65mm long MS Screws through the grrove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200mm. A strip of 5mm thick PVC sheet of width 75mm featherd at edges shall be stuck at the places where two panels are joined, using solvent cement Complete as per direction of Engr-in-Charge. Note :- ( Material will be of Rajshree/ Sintex/ Cactus and will be fabricated through authorised fabricators of the approved firm)
43S & F of fibre glass reinforced plastic (FRP) door frames of cross section 95mm X45 mm having double rebate of 32mmX15mm to recive shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resign and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three leg the frame shall be covered with fibre glass in all side MS stay shall be provided bottom to steady the frame complete as specified by the manufacture and as per the direction of Engineer-in-charge.
44Supply and fixing 30 mm thick fiber glass reinforced plastic (FRP) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyesteresin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856 complete all as specified by the manufacturer and as per directions of Engineer- in-charge.
45S & F of aluminium butt hinges medium weight 100mm type C-21 complete all as specified.
46S & F of 150mm aluminium anodised barrel tower bolt complete all as specified.
47S & F of 150mm aluminium anodised handles cast type complete all as specified.
48M & L for preparation of new wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified.
49S & F of powder coated aluminium frame for doors, windows, ventilators with one or more rebates or three track section for windows including joining cleat for fixing etc. complete all as specified by Engineer-in-Charge.
50S & F of powder coated aluminium window and ventilator shutters, fixed type/sliding type without sash bar, including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, lock, screws etc. complete all as specified and directed by Engineer-in-Charge.
51S & F of powder coated aluminium window and ventilator shutters, side hung type without sash bars, including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed by Engineer-in-Charge.
52S & F of sheet glass 4.80mm thick ordinary quality with oil putty or rubber and beading complete all as specified and directed
53S & F in repairs of 25mm stainless steel curtain rod of approved quality including fixing with brackets, knobs, screws etc complete all as specified and directed.
54Taking down GI pipes and connection including cleaning for refixing or removal to store of 15mm bore all as directed.
55Taking down GI pipes and connection including cleaning for refixing or removal to store of 20mm bore all as directed.
56Cutting chases in brick wallsfor concealed water tubing or concealed conduit wiring, etc., and making good in PCC or CM(1:3) not exceeding 10 cm girth complete all as specified and directed.
57S & F of galvanised iron tubing medium grade, with all fittings and fixed complete to wall and ceiling or laid in floors concealed where necessary bore of tube 15mm all as specified and directed.
58S & F of galvanised iron tubing medium grade, with all fittings and fixed complete to wall and ceiling or laid in floors concealed where necessary bore of tube 20mm all as specified and directed.
59Supply, hoisting and fixing in repairs of rotational moulded PVC water storage tank, 500 litres capacity cylindrical vertical type triple-layered with closed top including inlet,PVC float valve and necessory fittingsoutlet and wash out holes of approved make including dismantling of existing tank of any descriptionand removing from site of work complete all as specified and as directed.
60Supplying, hoisting and fixing of rotational moulded PVC water storage tank, 500 litres capacity conforming to IS-12701 (1996) cylindrical vertical type triple-layered with closed top including PVC float valve and necessary fittings for inlet, outlet and wash out holes complete all as specified and as directed.
61S & F in repairs of vitreous china squatting pan "Orissa" pattern of size 580mm x 440mm white with integral foot rest with "P" or "S" trap, front or back inlet and connection to trap with cement concrete bedding etc complete all as specified and as directed.
62S & F in repair PVC valveless, syphonic action type, flushing cistern, 10 litre capacity, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
63S & F of vitreous china wash hand basin white flat back of size 550mm x 400mm including cutting for and pinning ends of brackets including 32mm bore PTMT waste coupling (half or full threaded) and PVC waste pipe 32mm dia and 15mm bore PVC connection 450mm long with brass union and jam nuts on both sides and fixed on a pair of MS cantilever bracket of appropriate size complete all as specified and directed.
64S & F in repairs of 15mm bore dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type screwed down high pressure, with or without lettered `Hot" or `Cold" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
65S & F in repairs of 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
66S & F in repairs of 15mm dia PVC connection with PTMT nuts of length 450mm complete all as specified and as directed.
67S & F in repairs of 15mm dia concealed fancy type stop valve copper alloy with chromium plated fixed to iron pipe complete all as specified and as directed.
68S & F in repairs of chromium plated 125mm long flat shape for wall mounted showers with flange complete all as specified and directed.
69S & F of 15mm bore angular stop cock fancy type, cast copper alloy chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
70S & F in repairs of 15mm CP fancy type bib cock long body all as specified and directed.
71S & F in repairs of brass chromium plated towel rail 20mm dia D type 60cm long all as specified and directed.
72S & F in repairs of soap dish holder CP all as specified and directed.
73S & F in repairs of glass shelf with bracket all as specified and directed.
74S & F of 125mm chromium plated grating with or without waste hole all as specified and directed.
75S & F in repairs Sinks with drainage board made of stainless steel 1 mm thick for kitchen or laboratory including plugs, washers, waste coupling and waste pipe including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460 bowl size 410mm x 330mm x 160mm fixed complete all as specified and directed.
76S & F in repairs 100mm dia, cast iron, spun, soil waste and vent pipe, in any length with or without ears, with cement joints, fixed to wall, complete all as specified and directed.
77S & F in repairs 100mm bore cast iron plain bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified & directed.
78S & F in repairs cast iron 100mm bore branch pieces, single (equal or unequal), ordinary or inverted (spigot or socketed type) or with parallel branch,fitted with oval access doors, complete all as specified & directed.
79S & F in repairs, 100mm dia, cast iron floor trap with and including suitable size chromium plated stainless steel grating including jointing to waste pipe, fixed to cement concrete type B1 1:2:4, complete all as specified and directed.
80Taking down rainwater pipes (any size or pattern), including all fittings heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store (measured over all as fixed along the centre line over fittings and accessories)
81S & F of PVC (SWR) 110mm dia rain water pipe single socket any length with rubber rings joints fixed to walls complete all as specified and as directed.
82S & F of PVC (SWR) 110mm dia bend any radius including cutting brick wall / concrete and making good the disturbed surfaces complete all as specified and as directed.
83S & F PVC (SWR) 110 mm junction (Single T) equal or unequal 110mm complete all as specified and directed.
84Demolition of reinforced cement concrete as in RCC chajja, chimney, beams, slab, shelves etc. by chiseling and cutting the reinforcement including removing the rubbish / debris to a distance as directed by Engr-in-charge, complete all as specified and directed.
85M & L for reinforced cement concretetype B1 1:2:4, 20 mm graded aggregateas in cover slab, landings, lintel beams, chajja etc complete all as specified and directed. (Reinforcement shall be measured and paid seperately).
86M & L for TMT deformed bars 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as directed and specified.
87M & L for TMT deformed bars 6 to 8mm dia, cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as directed and specified.
88M & L for formwork to fair finished sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
89M & L for PCC 1:5:10 type E-2 using 40 mm graded stone aggregate as in foundation filling / mass concrete (as in sunken floor)with and including demolition of existing PCC from sunken portion and removed the same to a distance as directed by Engr-in-Charge, complete all as specified.
90M & L for 40mm thick PCC 1:2:4 type B-0, using 12.5mm graded stone aggregate mixed with integral water proofing compound (As per manufacturer"s instructions) as in bottom surface of sunken portion with proper slope towards spout pipe with and including 15mm thick rendering in CM 1:3mixed with integral water proofing compound (As per manufacturer"s instructions) on vertical surfaces. After laying sewage / plumbing pipes & fitting & fixtures in position , two coats of epoxy compound shall be applied, complete all as directed. Note:- (i) Water tightness test shall be carried out by ponding test for 72 hours & defects (If any) observed shall be rectified by the contractor at his own cost as directed by Engr-in-Charge. (ii) The process of grouting & ponding test shall be repeated by the contractor at his own cost until leakage / seepage / dampness of sunken portion not stopped.
91S & F 25mm dia GI pipe, medium grade as in spout pipe, jointing and testing for leakage proofing from around the spout pipe, grouting in wall by making hole of suitable dia and making good the disturbed surfaces of wall with existing finish, complete all as specified and as directed.
92M & L for water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment specifications from bottom to top : - Contd….
93(a) Removal of existing treatment and wire brushing and cleaning top surface of tiles and roofs to preparation of surface for applying in primer and bitumen.
94(b) M & L for 15mm thick rendering on fair faces of concrete surfaces in CM(1:4) with water proofing compound @ 100ml per 50 Kg of cement complete all as specified and directed. (WPC measured and paid seperately)
95(c) Applying APP based polymeric membrane minimum weight 3Kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (weight not less than 150gms/sqm) land on coat of bituminous shalitex primer @ 0.3litres/sqm by forced application complete all as specified and directed.NOTE:- Laying shall be done all as per manufacturer"s instruction and all as specified in clauses 11.43 of MES SSR-2020 Specifications.
96M & L for cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed laid over and including 15 mm screed bed in CM(1:6), set, jointed and pointed in neat cement slurry as in roof tiles complete all as specified.
97M & L for cement concrete type B1 1:2:4 ( 20 mm graded stone aggregate) providingcement concrete in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
98Supply only liquid water proofing compound.
99M & L for Providing & injecting chemical for post construction ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in a portion with CM (1:2) to match the existing apron complete all as specified and directed.
100M & L for Post Construction anti termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with CM (1:2) to match the existing floors all as specified and directed.
101Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth, for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
102Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
103M & L for removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed.
104M & L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
105M & L for PCC 1:4:8 type-D2 (using 40mm graded stone aggregate) in foundation ,filling and mass concrete complete all as specified and directed.
106M & L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls and lintel beams including necessary formwork complete all as specified and directed.
107M & L for 40mm thick damp proof course in cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) to horizontal or vertical surfaces including necessary formwork and supply of water proofing compound as per manufacturer"s instructions complete all as specified and directed.
108Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 100mm dia of pipe complete all as specified.
109S & F rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides fixed with angle cleats or other connecting plates conforming to Gde Fe-410 W complete all as specified and directed.
110M & L for applying two coats of synthetic enamel paintover a coat on redoxide primer of newsteel surfaces any description, not otherwise described over 10 cm width or girth complete all as specified and directed.
111M & L pre-painted coloured galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick having tensile strength of 550Mpa as in roof covering fixed with self tapping screws complete all as specified and directed.
112S & F of vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement mortar 1:3 including PTMT waste coupling, PVC waste pipe complete all as specified and directed.
113M & L for 75mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
114S & F of suspended ceiling system of grid/section size 600x600mm comprising of GI powder coated main 39x24x0.8 mm thick ( thickness comprising of GI/0.40+PPGS/0.3) cross Tee 29X24X0.8 MM thick and wall angle 22.2x22.2x0.65 mm thick with and including 4 mm thick E-board false ceiling tiles to be placed in the grid system duly suspend with 6 mm dia GI wire hangers fixed with steel dash fasteners or from purlin of the roof with clip complete all as specified and directed.
115E/M Items :
116Taking down copper /aluminium point wiring (light, fan, bell,socketor power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc.Removing materials to store for keeping in safe custody or for taking credits and making good distrubed surfaces ofwalls, floors etc complete all as specified and directed at site.
117Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
118Taking down carefully copper/aluminium Sub main wiring of any size fromsurface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
119Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan bladesand deposit to MES store yard complete all as specified and as directed.
120Taking down existing single phase electronic energy meter of any capacity after disconnecting all necessary electrical connections and deposit to MES store yard complete all as specified and as directed.
121M&L for point wiring with 1.5 Sq mmsingle corePVC insulated unsheathedcopper FRLSH multi stranded conductor cable in andincludingConcealed PVC conduitof size 20/25mm ISImarked inclusive oftees ,bend ,elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc withwhite laminated 3 mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi strandedcopper conductor 1.5Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminalincludingcutting, chasses and makinggooddisturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :-
122(a) One light point controlled by one, one way switch 5 Amps
123(b) One light point controlled by one, two way switch 5 Amps
124(c) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
125(d)One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
126(e) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
127(f)One bell point controlled by one, bell switch 5 Amps
128Ditto all as per item No 117 here in before butusing 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and as directed.
129S & F for Switch Piano type single pole 5 amp, 230 Volts complete all as specified and directed at site.
130S & F for Switch Piano type2 way switch 5 amp, 230 Voltscomplete all as specified and directed at site.
131S & F for Switch Piano type single pole 15 amp, 230 Volts complete all as specified and directed at site.
132S & F for switch bell push pianotype 5 amp, 230 Volts Complete all as specified and directed at site.
133S & F forsocket outlet 2 in 1 , 5 pin, 5 amp, 230 Volts complete all as specified and directed at site.
134S & F forsocket outlet 2 in 1 , 5 pin, 15 amp, 230 Volts complete all as specified and directed at site.
135S & F for Ceiling rose, surface Bakelite with 3 terminals, ISImarked for batten fitting complete all as specified and as directed.
136S & F for stepped type electronic fan regulator flushType complete all as specified and directed at site.
137S & Ffor lamp holder , PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and directed.
138S & Ffor Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed.
139M & L forSub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit
140S & F for sheet metal enclosure MCBDBSPN12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
141S & F for sheet metal enclosure MCBDBSPN8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
142S & F for sheet metal enclosure MCBDBSPN4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
143S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, "C" curve complete all as specified and as directed.
144S & Ffor MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, "C" curve complete all as specified and as directed.
145Fixing only for refixing the celing fan with copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal complete all as specified and as directed.
146S & F for Highly efficient LED Bulbs, 10 W, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap of make Bajaj, Havells, HPL complete all as specified and as directed.
147Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
148S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
149Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm all as specified and directed.
150Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers all as specified and directed.
151Supply and fix electric water heater, storage type steel body with copper inner tank andHeating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safetyValve, thermostate, NRV, connection piece etc complete all as specified and as directed.
152Refixing existing single phase electronic energy meter of any capacity after connecting all necessary electrical connections complete all as specified and as directed.
153Taking down existing old Extg unserviceable LT UG/ service cable of any description and size complete all as specified and as directed.
154Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m in depth oftrenches for laying of pipe lines and getting out including forming bottom surfaces to required level complete all as specified and as directed.
155Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
156Removing excavated material (soil) at a distance n.exc 50m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed.
157M&L for providing dry sand as in cushioning to underground cable including punning down of sand in layers as specified and directed.
158M&L for brick protection cover of UG cable by using old size sub class "B""common burnt clay building bricks,laid dry and flat abutting each other with width equal to length of the brick and gap between adjacent brick n.exc 10 mm complete all as specified and directed.
159S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 2 core core all as specified and directed.
160Supply and laying & testing and commisioning LT underground cable of size 6 sqmm 2core, 1100 volts grade, XLPEinsulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ducts, on poles etc of size complete all as specified and as directed.
161S&F GI Pipe 40 mm dia light gradefor protection of cable complete all as specified and as directed.
162M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x6.0 mm thick, burrieddirectly in ground (earth pit not less than 2.25 metres deep belowground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0mm dia Protedcted by light GI Pipe 20 mm dia and 15 dia med grade for watering pipe and connected by means of bolts, nuts, check nuts and washers of galvanized iron or steel, iron funnel,Iron pit cover and chamberall as shown in electrical plate No. 3 connected to earthing test point including testing on completion complete all as specified and directed.
163Note : Tenderers may note that amount of credit Rs 77,448.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.