Tender For Repair / Maintenance Of Certain Summer Appliances And Connected Works Under Age E / M Bairagarh Bhopal, Repair / Maintenance Of Walking Cooler, Mortuary Body Cabinate And Misc Items At New Mh Bhopal And Repair / Maintenance Of Lt Panels, Lt , bhopal-Madhya Pradesh

Military Engineer Services-MES has published Tender For Repair / Maintenance Of Certain Summer Appliances And Connected Works Under Age E / M Bairagarh Bhopal, Repair / Maintenance Of Walking Cooler, Mortuary Body Cabinate And Misc Items At New Mh Bhopal And Repair / Maintenance Of Lt Panels, Lt . Submission Date for this Tender is 28-11-2023. Air Conditioner Tenders in bhopal Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40344416
Corrigendum : Tender For Repair / Maintenance Of Certain Summer Appliances And Connected Works Under Age E / M Bairagarh Bhopal, Repair / Maintenance Of Walking Cooler, Mortuary Body Cabinate And Misc Items At New Mh Bhopal And Repair / Maintenance Of Lt Panels, Lt
Open Tender
Indian
Madhya Pradesh
bhopal
28-11-2023

Tender Details

Repair / Maintenance Of Certain Summer Appliances And Connected Works Under Age E / M Bairagarh Bhopal, Repair / Maintenance Of Walking Cooler, Mortuary Body Cabinate And Misc Items At New Mh Bhopal And Repair / Maintenance Of Lt Panels, Lt Cables, Oh Lines And Allied Works At Bairagarh Under Ge Bhopal

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Nov-2023 DATE Date 16-11-2023
2 07-Nov-2023 BOQ BOQ 16-11-2023
3 16-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-11-2023
4 23-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 84000.0 /-
Tender Value
INR 42 Lakhs /-

BOQ Items

Name of Work : REPAIR/MAINT OF CERTAIN SUMMER APPLIANCES AND CONNECTED WORKS UNDER AGE E/M BAIRAGARH BHOPAL, REPAIR/MAINT OF WALKING COOLER, MORTUARY BODY CABINATE AND MISC ITEMS AT NEW MH BHOPAL AND REPAIR/MAINT OF LT PANELS, LT CABLES, OH LINES AND ALLIED WORKS AT BAIRAGARH UNDER GE BHOPAL
Sl. No. Item Description
1Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
2Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for pole foundation, cable trench, etc and getting out in soft loose soil complete all as specified and directed.
3Excavation in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in depth for pole foundation, cable trench, etc and getting out in hard dense soil complete all as specified and directed.
4Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
5Removing excavated materials (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
6M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. Note:- Punned thickness shall be measured and paid separately.
7Supplying and laying un-reinforced precast concrete cable cover, class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.
8Dismantling of cross arms, bracings, supports, clamps and back plates from existing poles (other than dismantled poles) and pole structures complete all as specified and directed.
9Fixing only cross arms, bracing, supports, clamps and back plate, obtained from demolition with & including new nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
10S&F of cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
11M&L for earthing with GI strip as earth lead and MS galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 32 x 6 mm with GI pipe, nuts, bolts and washers upto and including test point made out of 40 x 3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame including plastering and white wash, charcoal, common salt 15cm at round the earth plate, watering pipe 20mm medium grade galvanized and 40mm dia GI pipe medium grade for GI strip protection with GI funnel complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2020. Notes: CONTRACTOR SHALL BE PRODUCE TEST RESULT DATA SHEET, IF RESULT NOT CAME AS REQUIRED, HE HAS TO REDONE WITHOUT ANY EXTRA COST. (i) The unit rate includes for 40mm dia medium grade protection pipe and earth lead upto 7.50 meter. (ii) Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured & paid seperately. (iii)PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional height of watering pipe, bends, elbow etc shall be deemed to be included in the unit rate.
12S&F of earth continuity conductor or main earthing lead of 32 x 6 mm galvanized iron strip, buried in ground or fixed to wall complete all as specified and directed.
13S&F in repair of earthing pit cover with fixing of funnel of required size in PCC 1:2:4 type B1 and RCC cover with frame as shown in electrical plate No-03 of SSR Part-I 2020 complete all as specified and directed.
14M&L for painting of steel pole (swan neck type or straight type) up to 9 mtr heightwith cross arms, clamp of any length and shape for LT overhead line/street light with two coats of aluminium paint after scratching out old paint, cleaning the existing surface rust free, preparation of the surface including marking pole numbers in a 20 cm dia yellow circle with number writing with black synthetic paint & painting strips in alternate from bottom to top with three strips of black synthetic paint & two strips of white fluorescentpaint (up to 1.5 mtr height) throughout the circumference of pole (width of each strip shall be of 30 cm), including one coat of lime wash on PCC copping of pole complete all as specified and directed.
15M&L for painting the cross arms, clamps etc of LT PCC poles of 9 m heightafter preparation of surface, making the surface smooth with two coat of aluminium paint & providing alternative bend of 30 cm width (3 black and 2 white) from bottom of pole to 1.5 m height with two coat painting with synthetic enameled paint, writing of polenumbers in yellow circle 15 cm with black paint onpoles complete all as specified and directed.
16M&L for loose filling broken stone or boulders of40 mm to 80 mm sizearound transformer plinth/four pole and two pole structures complete all as specified and directed.
17M&L for maint and cleaning of surrounding area of sub station near LT panels, transformer etc by cutting seasonal grass, bushes etc, by employing skilled mazdoor including using own T&P as required to do the job and taking all precaution while men on working in sub station being danger zone complete all as specified and directed.
18Cutting & trimming tree branches along HT/LT over head lines after arranging shut down and by taking all precautions while working on lines, etc including all T&P required for the purpose and removal of rubbish complete all as specified and directed.
19M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
20M&L for cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
21M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
22M&L for tightening and restringing of existingACSR over head conductor of any size/type on LT over head line with the help of rope/line wise and tighting the conductor to permissiable sag with and including new aluminium tape/aluminium wire complete all as specified and directed. NOTE:- Each conductor to be measured seperatly.
23Dismantling of ACSR conductor of any type and size complete all as specified and directed.
24S&F of aluminium conductor steel reinforced including straining properly on insulators and binding with aluminium binding wire complete all as specified and directed. Type of new conductors:- weasel/ rabbit/ Mink) Note : Measurements for the purpose of payments shall be made by measuring horinzontal distance between centers of two adjacent poles and adding 3% extra for sag, joints, jumpers etc.
25S&F in replacement cradle guard hexagonal/rectangular, fabricated with galvanized steel wire 3.15mm dia complete all as specified and directed.
26S&F of steel tubular pole, swaged with cast iron base plate, final taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC, numbering of poles in 100mm diameter yellow circle with black paint including 15 cm wide alternate black & yellow bands upto 1.5m height from ground level, type 410-SP-31 (9 meter long) including dismantling after disconnecting existing damaged LT PCC or steel poles, any length long and demolition of cement concrete complete all as specified and directed. Note - Excavation, earth work and PCC shall be measured and paid separately.
27S&F of MCCB, 630 amp, 4 pole, 50 KA, 415 V, thermal magnetic release type, ICS=100% ICU, with adjustable overload setting and adjustable short circuit setting and ground fault, including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB complete all as specified and directed. Make: Cat part No-6699 29 of Legrand or equivelent in Schinder/ Seimens as approved by GE.
28S&F of MCCB, 400 Amp, 4 Pole, 36 KA, 415 V, thermal magnetic release type, ICS=100 % ICU, with adjustable overload setting and adjustable short circuit setting and protection against ground fault, including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB, complete all as specified and directed. Make :Cat part No-6699 27 of Legrand or equivelent in Scheinder/ Seimens as approved by GE.
29S&F of MCCB, 250 Amp, 4 Pole, 25 KA, 415 V, thermal magnetic release type, ICS=100 % ICU, with adjustable overload setting and adjustable short circuit setting and protection against earth protection leakage fault, including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB, complete all as specified and directed. Make : Cat part No-4203 29 of Legrand or equivelent in Scheinder/ Seimens as approved by GE.
30S&F MCCB, 200 Amp, 4 Pole, 25 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting andEarth protection leakage fault module,including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB, complete all as specified and directed. Make : Cat part No-4202 28 of Legrand or equivelent in Scheinder/ Seimens as approved by GE.
31S&F of MCCB, 160 Amp, 3 Pole, 16 KA, 415 V, thermal magnetic release type, ICS=100 % ICU, with adjustable overload setting and adjustable short circuit setting, with thermal release range 125-160 Amp including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB, complete all as specified and directed. Make:- Cat part No-4200 17 of Legrandor equivelent in Schinder/ Seimens as approved by GE.
32S&F of MCCB, 100 Amp, 3 Pole, 16 KA, 415 V, thermal magnetic release type, ICS=100 % ICU, with adjustable overload setting and adjustable short circuit setting, with thermal release range 100-125 Amp including spreader terminals and phase barriers including taking down old unserviciable burnt MCCB, complete all as specified and directed. Make: Cat part No-4200 16 of Legrandor equivelent in Schinder/ Seimens as approved by GE.
33Dismantling of LT insulator of any type any size complete all as specified and directed.
34S&F of pin type, polymer insulator, 100mm height, 65 mm diameter for 1100 volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, complete all as specified and directed.
35S&F of shackle type, polymer insulators 90mm diameter and 75mm height for working pressure 1100 volts including galvanised mild steel strap 31 x 3mm size, washers, 12mm diameter insulator bolts, washers and nuts complete all as specified and directed.
36M&L for servicing/ repairing of LT panel of any sizes, consisting of MCCB, bus bar ampere meter, volt meter, selector switch and phase indication neon lamp, all parts should be cleaning and removing the carbon, tighting the bolts, nuts and washer, lugs of cables, replacement of old rusted/damaged hardwares with new galvanised bolts, nuts and washers, tapping/ insulating all exposed cables in LT panel with PVC insulation tape as per site requirement completeall as specified and directed.
37M&L for fixing MS sliding locking door bolt of size not less than 12 mm dia, 250 mm length bolt, stove enameled black with bright bolt with staple plate on LT panel doors (for locking of doors) with min six nuts, bolts and washers including drilling and fixing on site complete all as specified and directed.
38S&F of butt hinges, heavy weight, cold rolled mild steel, 100mm size duly welded to doors of LT panel board, etc complete all as specified and directed.
39S&F in repairs LED indication lamps (Red, Green, Yellow) (set of three) complete all as specified and directed.
40Supplying, installing, testing and commissioning of 3 Phase digital electronic volt meterwith accuracy class 1.0, suitable for LT 1.1 KV panel flush pattern, square type (96 x96 mm) with built-in selector switch with making electrical connections including taking out old unserviciable voltmeter complete all as specified and directed. Make : L&T Model Vega or equivelent in Seimens/ Schinder as approved by GE.
41Supplying, installing, testing and commissioning of 3 Phasedigital electronic ampere meter, 5A with accuracy class 1.0, suitable for LT 1.1 KV panel flush pattern, square type (96 x96 mm) with built-in selector switch with making electrical connections including taking out old unserviciable amper meter complete all as specified and directed. Make:- L&T Model Vega or equivelent in Seimens/ Schinder as approved by GE.
42M&L in replacement of LT cable straight through joint/ End joint heat shrinkable type with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size 16 Sqmm to 35 Sqmm x 3.5 core complete all as specified and directed.
43M&L in replacement of LT cable straight through joint/ End Joint heat shrinkable type with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size50 Sqmm to 70 Sqmm x 3.5 core complete all as specified and directed.
44M&L in replacement of LT cable straight through joint/ End Joint heat shrinkable type with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size95 Sqmm to 120 Sqmmx 3.5 core complete all as specified and directed.
45M&L in replacement of LT cable straight through joint/ End Joint heat shrinkable type with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size 150 Sqmm to 185 Sqmm x 3.5 core complete all as specified and directed.
46M&L in replacement of LT cable straight through joint/End Joint heat shrinkable type with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size 240 Sqmm to 400 Sqmm x 3.5 core complete all as specified and directed.
47S&F in repairs LT line PVC spacers (strip type) for two wire complete all as specified and directed.
48All as per item No. 46.00 here-in-before but for three wire complete all as specified and directed.
49All as per item No. 46.00 here-in-before but for four wire complete all as specified and directed.
50All as per item No. 46.00 here-in-before but for five wire complete all as specified and directed.
51Supplying, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, heavy duty cable with aluminium conductor, 1100 volts grade, laid in trenches, passing through pipes/ducts, on walls with saddle, etc including taking out old unserveciable cable, any type with aluminium conductor of size 10 Sqmm, 2 core complete all as specified and directed. Note: For item No 51.00 to 61.00 contractor will produce manufacture test certificate and warranty certificate.
52All as per item No. 50.00 here-in-before but for size 16 Sqmm, 4 core complete all as specified and directed.
53All as per item No. 50.00 here-in-before but for size 25 Sqmm, 3.5 core complete all as specified and directed.
54All as per item No. 50.00 here-in-before but for size 35 Sqmm, 3.5 core complete all as specified and directed.
55All as per item No. 50.00 here-in-before but for size 50 Sqmm, 3.5 core complete all as specified and directed.
56All as per item No. 50.00 here-in-before but for size 70 Sqmm, 3.5 core complete all as specified and directed.
57All as per item No. 50.00 here-in-before but for size 95 Sqmm, 3.5 core complete all as specified and directed.
58All as per item No. 50.00 here-in-before but for size 120 Sqmm, 3.5 core complete all as specified and directed.
59All as per item No. 50.00 here-in-before but for size 150 Sqmm, 3.5 core complete all as specified and directed.
60All as per item No. 50.00 here-in-before but for size 185 Sqmm, 3.5 core complete all as specified and directed.
61All as per item No. 50.00 here-in-before but for size 240 Sqmm, 3.5 core complete all as specified and directed.
62All as per item No. 50.00 here-in-before but for size 630 Sqmm, 3.5 core complete all as specified and directed.
63S&F of 40mm GI tubing, light grade, with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S. flat iron clamps including nut, bolt and washer including taking down old rusted pipe complete all as specified and directed.
64S&F of 50mm GI tubing, light grade, with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S. flat iron clamps including nut, bolt and washer including taking down old rusted pipe complete all as specified and directed.
65S&F of 80mm GI tubing, light grade, with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S. flat iron clamps including nut, bolt and washer including taking down old rusted pipe complete all as specified and directed.
66S&F of 100mm GI tubing, light grade, with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S. flat iron clamps including nut, bolt and washer including taking down old rusted pipe complete all as specified and directed.
67S&F in repairs aluminium lugs with brass thimble stud of any type for size of 16 sqmm complete all as specified and directed:-
68All as per item No. 66.00 here-in-before but for size 25 sqmm complete all as specified and directed.
69All as per item No. 66.00 here-in-before but for size 50 sqmm complete all as specified and directed.
70All as per item No. 66.00 here-in-before but for size 70 sqmm complete all as specified and directed.
71All as per item No. 66.00 here-in-before but for size 95 sqmm complete all as specified and directed.
72All as per item No. 66.00 here-in-before but for size 120 sqmm completex all as specified and directed.
73All as per item No. 66.00 here-in-before but for size 150 sqmm complete.
74All as per item No. 66.00 here-in-before but for size 240 sqmm complete all as specified and directed.
75All as per item No. 66.00 here-in-before but for size 300 sqmm complete all as specified and directed.
76S&F of brass thimble stud of required size size 25 sqmm complete all as specified and directed.
77M&L for painting of extisting out door LT cubical panel from outer side with two coats of existing powder coated paint after scraching out old paint, cleaning and existing surface rust free, preparation of the existing surface complete all as specified and directed. Note:- Max size of LT cubical panel 1700 X1500 X 250 mm.
78M&L for dismantling of overhead conductor of any size and type from any type of pole and lowering down safely (to avoid conductor to be damaged during tree cutting of tall branches or for replacement of pole) and refixing and tightening and stringing of existing conductor after cutting of tree on pole with the help of rope/line wise and tighting the conductor to permissiable sag with and including new aluminium tape/aluminium wire complete all as specified and directed. Note:- Each conductor and tree cutting to be measuredand paid seperatly under relevent item.
79M&L for servicing/repairing of capacitor panel of any type and size upto 150 KVAR for making them functional, removing and cleaning of dusts, checking control wiring and connections, replacement of any damaged control wire, checking of capacitors, tightening of all electrical connections and hardware, checking of metering devices, relays, etc, replacement of defective unserviceable parts to make the panel fuly functional complete all as specified and directed. NOTE:- Spares required shall be paid separately for supply only.
80Supply only heavy duty resin filled power capacitor, 440V, 3 phase, 50 Hz, conforming to IS, IP 20 with over pressure disconnector, dielectric -MPP of 15 KVAR complete all as specified and directed. Make:-Legrand (Apican)/ Shreem / Neptune or equivalent as approved by GE.
81Supply only heavy duty resin filled power capacitor, 440V, 3 phase, 50 Hz, conforming to IS, IP 20 with over pressure disconnector, dielectric -MPP of 10 KVAR complete all as specified and directed. Make:-Legrand (Apican)/ Shreem / Neptune or equivalent as approved by GE.
82Supply only heavy duty resin filled power capacitor, 440V, 3 phase, 50 Hz, conforming to IS, IP 20 with over pressure disconnector, dielectric -MPP of 5 KVAR complete all as specified and directed. Make:-Legrand (Apican)/ Shreem / Neptune or equivalent as approved by GE.
83Supply only power factor controller of 8 step controller, complete all as specified and directed. Make : Legrand Cat part No. 415042 or equivelent inShreem/ Neptune as approved by GE.
84Supply only power factor controller of 6 step controller, complete all as specified and directed. Make : Legrand Cat part No. 415042 or equivelent inShreem/ Neptune as approved by GE.
85Supply only MCB SP, 6 to 32 Amp, 240 V, 10 KA "C" curve,IP 20, Confirming to IS, complete all as specified and directed.
86Supply only control coil 230 V suitable for4 Pole contactor, complete all as specified and directed.
87Supply only add on auxiliary contact block front mounting, 2 NO + 2 NC for pole contractor 25 Amp, complete all as specified and directed.
88Supplying, fabricating and fixing of LT panel door made up of CRCA sheet min 3.15 mm thick duly painted with powder coated Siemens Grey paint, factory made, door of size suitable for existing LT panel and fixed, welded on site with panel body with havey duty hinges, with locking arrangement complete all as specified and directed.
89M&L for Cutting of bituminous road/PCC hard standing/road/floor for laying of GI pipe upto 80mm dia (trench not more than 0.3m x 0.3m) for passing of cable including making good the disturbed surfaces all as per existing complete all as specified and directed. Note:-GI pipe shall be measured and paidseparately.
90M&L for painting of 33 KV MRS Bairagarh Power house chainlink fencing including barber wire, angle iron, (65 m length X 65 m width and 1.5 m height approx) including main gate,after preparation of surface, making the surface smooth and applyingtwo coat of aluminium paint over a coat of red oxide primer from bottom of fencing upto top including white wash of main gate pillar etc complete all as specified and directed.
91Supply and laying synthetic rubber insulated mats 2mm thick for voltage upto 3.3 Kv for electrical purpose as per IS 15652-2006 suitable for electrical shock safety ofsize 1 m x 2 mcomplete all as specified and directed.
92Supplying and spreading grass killer chemical all around to kill unwanted grass near or below the feeder panel and any E/M installation of capacity 1 Litre bottle complete all as specified and directed.
93S&F in repairs for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size for LT, 200 mm X 150 mm complete all as specified and directed.
94Supplying and laying sub class "B" bricks (modular) for settlement on base for aggregate laid flat and dry in complete all as specified and directed.
95WATER COOLER STORAGE TYPE Taking out existing compressor unit from the water cooler of capacity 40/80/120/150 Ltr of any type and any make including removed of all other unserviceable parts/spares such as strainers, filter, capillary tubes suction /discharge pipe, thermostat switch, float valve, push cock running, starting capacitor, over load relay complete all as specified and directed.
96S&F of new company compressor of defective compressor to water cooler of 150 ltr capacity including painting, jointing capillary tube and testing the compressor complete all as specified and directed.
97All as per item No. 95.00 here-in-before but for capacity 60/120 Ltr. complete all as specifid and directed.
98All as per item No. 95.00 here-in-before but for capacity 40/80 ltr. complete all as specifid and directed.
99M&L for servicing of water cooler any size and make including drain outwater cleaning of water tank and cleaning of condensor coil with anti scaling solution complete all as specified and directed.
100M&L for charging of water cooler with R-22/134a gas including replacement/filling of compressor oil of make KAPILA "B" after leakage test and testing of water cooler on full load for 24 hrs continuously at site of any type and any make of capacity upto 150 ltr complete all as specified and directed.
101M&L for shifting of air conditioner split type of any make from its original position to another position with and including any B/R and electric work required for it complete all as specified and directed.
102M&L for shifting of air conditioner window type of any make from its original position to another position with and including any B/R and electric work required for it complete all as specified and directed.
103Taking out existing unserviceable fan motor of capacity 1/8 HP from water cooler, dismantling of motor and taking out old burnt copper winding wire, rewinding of fan motor with similar size super enamelled copper winding wire of make HTP/devidayal after providing "E" class insulation material including replacement of unserviceable pad MS clamps, nut and bolt, varnishing and refixing the motor in the water cooler and testing of water cooler complete all as specified and directed.
104S&F for connecting in replacement new fan motor of water cooler capacity 1/8 HP, 230 Volt 50complete all as specified and directed. Make-: Make of MIE/Khaitan/ Crompton Greaves or equivalent
105S&F in replacement of fan blades of fan motor of water coolerof capacity 150 ltr made out of GI Sheet as per existing shape and size complete all as specified and directed. Make-: Make sidwal or equivalent
106S&F for running capacitor 36 MFD of water cooler of capacity 120/150 ltr complete all as specified and directed.
107All as per Item No. 105.00 here-in-before but for starting capacitor 80-100 MFD.
108All as per item No. 105.00 here-in-before but for over load protector as per sample.
109All as per item No. 105.00 here-in-before but for starting relay 1/8 HP as per sample.
110All as per item No. 105.00 here-in-before but for plunger type relay as per sample.
111All as per item No. 105.00 here-in-before but for thermostat switch for water cooler as per sample.
112All as per item No. 105.00 here-in-before but for float valve 15mm bore, brass with ball.
113All as per item No. 105.00 here-in-before but for rubber hose pipe for 1 ½” dia and 1.5 m long drain pipe.
114All as per item No. 105.00 here-in-before but for over load/relay box type Y-412.
115REFRIGIRATOR 310/165 LTR & DEEP FREEZER 300/400 LTR Taking out existing compressor unit from the refrigerator of any capacity of any make including removed of all other unserviceable parts/spares such as over load relay, bulb, strainer, thermostat switch, bulb holder, capillary tubes, freezer door complete all asspecified and directed.
116Taking outexisting compressor unit from the deep freezer of any capacity and make including removal of all other unserviceable parts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder, capillary tubes, freezer door complete all asspecified and directed.
117S&F of new compressor in lieu of defective compressor to refrigerator of various capacity of310/280/180/165 ltr capacity including jointing capillary and testing the compressor complete all as specified and directed.
118S&F of new compressor to deep freezer of 500 ltr capacity including jointing capillary and testing the compressor complete all as specified and directed.
119S&F of new compressor to deep freezer of capacity 310 ltrincluding, jointing capillary tube and testing the compressor complete all as specified and directed. Note:-Test report duly signed by contractor and Engr-in-Charge to be required at the time of first payment.
120M&L for charging of deep freezer/refrigerator with R-22/R-32/R-134a gas of various capacity 400/200/310/165 Ltr or any size of any make including replacement of compressor oil of make capila "B" and testing complete all as specified and directed.
121S&F and coonecting of plunger type relay 1/6 HP of REFRIGERATOR complete all as specified and directed.
122All as per item No. 120.00 here-in-before but for over load protector 1/6 HP make Hitachi or equvilent as approved by GE.
123All as per item No. 120.00 here-in-before but for thermostat switch with knob - u-50-1018.
124All as per item No. 120.00 here-in-before but for freezer door for whirlpool refrigerator of Capacity 310 ltr.
125All as per item No. 120.00 here-in-before but for replacement of existing damage choked evaporator from the refrigerator of Capacity 310 Ltr of any make.
126All as per item No. 120.00 here-in-before but for replacement of the existing damaged choked evaporator from the refrigerator of Capacity 180/190/165 Ltr of any make.
127Taking out existing unserviceable fan motor of capacity 1/8 HP from the cooler/deep freezer/refrigerator dismantling the motor and taking out old burnt copper winding and rewinding of blower motor with similar size of super enameled copper winding wire after providing "E" class insulator material including replacement of bushes, name pad and varnishing refixing the motor in the DF Ref and testing of desert cooler complete all as specified and directed. Make: HTP/ Devidayal or equivalent.
128Taking out existing unserviceable fan motor of capacity 1/8 HP from the cooler/deep freezer/refrigerator dismantling the motor and connecting new fan motor complete all as specified and directed.
129AIR CONDITIONER WINDOW & SPLIT TYPE 1.5 /2 TON CAPACITY Dismantling/Taking out existing unserviceable window type air conditioner of capacity 1.5/2 Ton of any make and capacity and refixing the same to its position after serviceing with anti scaling solution and cleaning complete including removal of all other unserviceable parts/spares such as strainer, pillar suction, starting capacitor overload running capacitor relay etc complete all as specified and directed.
130All as per item No 128.00 here-in-before but split type AC of Capacity 1.5 /2 Ton.
131S&F of new compressor in lieu of defective compressor to air conditioner of 1.5 Ton/2.0 capacity window AC including jointing compressor, capillary, replacement of reverse valve copper tubing as required and testing the compressor complete all as specifid and directed. Note:-Test report duly signed by contractor and Engr-in-Charge to be required at the time of first payment.
132S&F of new compressor in lieu of defective compressor to air conditioner split type of 1.5 Ton/2.0 capacity including jointing compressor, capillary, copper tubing as required and testing the compressor complete all as specifid and directed.
133S&F in replacement of copper tubing for split type air conmditioner of 3/8 inch or any size required at site complete all as specified and directed.
134M&L for charging of air conditioner of capacity 1.5 TR/2.0 TR with R-22/R-32 gas/as on site including replacement/ filling of compressor oil of make Kapila "B" connecting lead tin coated thumble and installation of AC at site testing on full load for 24 hrs continuously complete all as specified and directed.
135Dismantling taking out existing unserviceable fan motor of capacity 1/8 HP from window type air conditioner/split type dismantling the motor and taking out old burnt copper winding wire and rewinding of fan motor with similarsize super enameled copper winding wire ofproviding"E" class insulation material includingreplacement of unserviciable rubber pad MS clamp nut bolt varnishing and refixing the motor in the AC and testing of air conditioner complete all as specified and directed. Make: HTP/ Devidayal or equivalent.
136S&F in repairs switch piano type, 240 volts, singe pole, one ways, 5 Amps, fixed in desert coolers complete all as specified and directed.
137S&F in repairs single pole and neutral enclosure with two pin and earth, plug and socket, single phase, 240 V with and including 1 No single pole MCB, capacity 20 amps, `C` charactristic, breaking cap 10 KA and industial plug top complete all as specified and directed. MAKE:-Legrand(Cat no.607841) or equivalent in Siemens/ Schinder/L&T/ ABB/Havells as approved by GE.
138S&F of PCB unit of spilt type AC of exsting make complete all as specified and directed.
139S&F in repairs of existing unserviceable PCB unit of spilt type AC of exsting make complete all as specified and directed.
140S&F in replacement of condensor coil of window type AC of 1.5 TR capacity of any make complete all as specified and directed.
141S&F in replacement of condensor coil of split type AC of 1.5 TR capacity of any make complete all as specified and directed.
142S&F and connecting running capacitor 36 MFD complete all as specified and directed.
143All as per item No 141.00 here-in-before but for over load protector No SR-1622.
144All as per item No 141.00 here-in-before but for starting capacitor 100-120MFD.
145All as per item No 141.00 here-in-before but for starting relay box type 1/8 HP SR-1622.
146All as per item No 141.00 here-in-before but for front show grill made of plastic including air filter.
147DESERT COOLER Taking out exiting unserviceable fan motor of capacity 1/8 HP from the desert cooler/ dismantling the motor and taking out old burnt copper winding and rewinding of blower motor with similar size of super enameled copper winding wire of providing "E" class insulator material including replacement of bushes, name pad and varnishing refixing the motor in the desert cooler and testing of desert cooler complete all as specified and directed. Make: HTP/ Devidayal or equivalent.
148Taking out existing unserviceable tulu pump (water pump) from the desert cooler and S&F of connecting new tulu pump 1/20 HP 230 Volt 50 C/S single phase complete all as specifid and directed. Make: MIE/Khaitan or equivalent.
149Taking out existing unserviceable fan motor from the desert cooler and S&F of connecting new fan motor 1/8 HP 230 Volt 50 C/S single phase including MS clamps and rubber pad complete all as specified and directed. Make: Cropmton/Bajaj or equivalent as approved by GE.
150S&F in replacement of desert cooler front show grill made of PGI sheet 20 gauge duly spray painting complete all as specified and directed.
151S&F in replacement of desert cooler sides shutters set of 3 made of PGI sheet 20 gauge with pad sporting frame of size duly painted complete all as specified and directed.
152S&F in replacement of capacitor 4 MFD, 230 volts 50 C/S of complete all as specified and directed.
153S&F in replacement of 3 way PVC distributor complete all as specified and directed.
154S&F in replacement of selector switch with knob complete all as specified and directed.
155Taking out unserviceable fan blades of fan motor from the desert cooler and S&F of new blade of standard quality and as per existing size complete all as specified and directed.
156Taking out existing serviceable fan motor and monobock pump from the unserviceable body of desert cooler carefully supply of desert cooler body made out of GI sheet 18 gauge duly spray painted including shutters front show grill made out of GI sheet, wooden wool pad and refixing the fan motor and tulu pump and testing complete all as specified and directed.
157M&L for painting of desert cooler body at site of any make and capacity with one coat of approved quality of synthetic enamelled paint over a coat of red oxide primer after cleaning of dust rust,complete removal of existing treatment and preparation of surface both inside and outside surface complete all as specified and directed.
158S&F of PVC pipe 15mm dia 3 mtr in each cooler complete all as specified and directed.
159Taking out unserviceable supporting leg fan motor with screw and fixing new supporting legs as per existing size complete all as specified and directed.
160S&F in replacement of wood wool pad, supporting wire frame (set of three) and fixing in water cooler complete all as specified and directed.
161Taking out carefully existing unserviceable copper PVC flexible 3 core cable and S&F ofPVC sheathed copper cable 3 core of size 70/ 00.0076 complete all as specified and directed.
162M&L for sub main wiring with two single core FRLS PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn innon metallic rigid PVC conduit of size 25 mm dia ISI marked including PVC insulated unsheathed 4 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly complete all as specified and directed. Note:-Two runs of cable as specified, one run of earth wire and one run of conduit shall be measured as one unit.
163M&L for sub main wiring with two single core FRLS PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn innon metallic rigid PVC conduit of size 25 mm dia ISI marked including PVC insulated unsheathed 6 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly complete all as specified and directed. Note:- Two runs of cable as specified, one run of earth wire and one run of conduit shall be measured as one unit.
164S&F in replacement of sheet metal enclosures with socket plug top and MCB"s with two pin and earth plug and socket complete with one single pole MCB 240 V grade 20 Amp complete all as specified and directed.
165S&F of sheet metal enclosure factory fabricated for multiphase out going suitable for mounting MCCB as incomer of rating 100 Amp vertical distribution board 4 way with suitable amp rated bus bar having IP-42 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified and directed. Cat No - DBVDD04160TAB -MCCB of HPL or Equivalent Model in Havells/Legrand/ABB as approved by GE. Note: MCCB & MCB shall be measured and paid separately.
166S&F of MCCB 100 Amp, 16 KA 3 Pole including electrical connection by appropriate size of copper lugs complete all as specified and directed.
167M&L for repair/maint of UPS for 30 min back up three phase AC input 3 phase, 4 wire voltage range (V AC), 310 to 480 V, 55 HZ, phase out put 3 phase, 4 wire, battery voltage(V DC) 360 V, battery charging current 10A, operating tempeature (celcius), 0 to 45 degree C, operating port RS-232 server and client, IP20 of DSP based double conversion online system with true galvanised isolation technology with output power 8000W and output voltage 415 V ± 1% of capacity 7.5 to 10 KVA including repair of mother board and replacement of defective battery as per site requirement and spare parts if required to make it functional complete all as specified and directed. Make :- Su-Kam
168M&L for AMC for aqua guard on quaterly basis including servicing, repair, renewal/ replacement of filters and defective spare parts if required to make it functional are deemed to inclusive of quoted rate, complete all as specified and directed.
169M&L for periodical maintenance on quarterly basis of walk in cooler of size 8" x 8" x 8" for preserving life saving medicine and medical stores with maintain temperature range from 2 degree C to 8 degree C, including dual air cooled split type cooling unit of capacity 1 TR/12000 BT U/Hr (one working and other standby) including repair of short circuit/damaged wiring, servicing of Indoor/outdoor unit including gas charging complete all as specified and directed. Note:- 1. Maintenance will be carried through OEM only. 2. Tenderer shuold quote the rate including oiling, greasing and minor spare parts as required. 3. Major spare parts as required to be measured and paid separately.
170Supply only following broken/burnt out spare part (only if required) complete all as specified and directed:-
171S&F of compressor for outdoor unit no 1 model No. RUAHOP1514
172S&F of PCB componant
173S&F of blower fan heavy duty of size 450mm sweep or as per site requirement
174M&L for Periodical maintenance on quarterly basis of walk in cooler of size 15" x 12" x 10"for preserving vegetable/meat stores with maintain temperature range from 2 degree C to 8 degree C, including dual air cooled split type cooling unit of capacity 5 TR/60000 BTU/Hr (one working and other standby)including repair of short circuit/damaged wiring, servicing of Indoor/outdoor unit including gas charging complete all as specified and directed. Note:- 1. Maintenance will be carried through OEM only. 2. Tenderer shuold quote the rate including oiling, greasing and minor spare parts as required. 3. Major spare parts as required to be measured and paid separately.
175Supply only following of broken/burnt out spare part (only if required) complete all as specified and directed:-
176S&F of compressor for outdoor unit no 1 Model No. RUAHO6024CS
177S&F of PCB componant
178S&F of blower fan heavy duty of size 650mm sweep or as per site requirement.
179M&L for Periodical maintenance on quarterly basis of mortuary cabinate for two body, 230 volt single phase, 50 hz with roof mounted refrigeration system of CP 6000 BTU/H, temperature range from 2 degree C to 6 degree C, complete with 1 piece stainless steel tray with handle including repair of short circuit/damaged wiring, servicing ofindoor/outdoor unit including gas charging complete all as specified and directed. Note:- 1. Maintenance will be carried through OEM only. 2. Tenderer shuold quote the rate including oiling, greasing and minor spare parts as required. 3. Major spare parts as required to be measured and paid separately.
180S&F of air curtain with adjustable loures with electric motor single phase 230 volts AC, 50 hz with maximum velocity 10-11 Amps (1000mm width), air speed 20 m/s of make cecon model No. C1-042 including repair of short circuit/damaged wiring, servicing, repair/replacement of defective parts if required complete all as specified and directed.
181M&L for Removing the unserviceable compressor sealed unit of any make from water cooler capacity 60 / 120 liters after cutting copper tubing without any damage to existing parts and S&F for replacement of new compressor with reconditioned compressor of same make with erection of compressor on base with suitable capillary, filter, etc jointing of copper refrigerant pipe line, charging gas to required level, including cleaning of fins, leakage testing, etc including testing for smooth functioning complete all as specified and directed.
182All as per item No. 174.00 here-in-before but for water cooler of capacity 40/80 Ltrs.
183All as per item No. 174.00 here-in-before but for water cooler of capacity 150/150 Ltrs.
184M&L for removing the condenser fan motor from water cooler of 40/80 ltrs capacity, rewinding the same with super enameled copper wire as per existing gauge and varnishing with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with washer nuts and bolts complete all as specified and directed.
185All as per item No. 177.00 here-in-before but for water cooler of capacity 60/120 Ltrs.
186All as per item No. 177.00 here-n-before but for water cooler of capacity 150/150 Ltrs.
187S&F in repairs plastic fan blade suitable for water cooler of capacity 40/80 Litres complete all as specified and directed.
188All as per item No. 180.00 here-in-before but suitable for water cooler of capacity 60 / 120 Ltrs complete all as specified and directed.
189All as per item No. 180.00 here-in-before but suitable for water cooler of capacity 150/150 Litrs complete all as specified and as directed.
190S&F in repairs starting capacitor 2.5 MFD, suitable for water cooler of any capacity complete all as specified and directed. Make:-EPCOS / USHA / ASIAN or equivalent as approved by GE.
191S&F in repairs running capacitor 2.5/10MFD suitable for water cooler of any capacity complete all as specified and directed. Make:-EPCOS / USHA / ASAIN or equivalent as approved by GE.
192S&F in repairs thermostat suitable for water cooler of any capacity complete all as specified and directed. Make: Danfoss / Indfoss or equivalent as approved by GE.
193M&L for servicing of deep freezer of capacity 265/ 320/ 492 ltrs of any make, checking / testing all parts for its serviceability, oiling / greasing of condenser motor including replacing bushes / rubber packing / gasket and insulating material and including repairing door and replacing handle, hinges, nut, bolts, washers etc, checking of refrigerant standing pressure and tapping of refrigerant up to the required level including testing for smooth functioning complete all as specified and directed.
194M&L for removing the unserviceable compressor sealed unit of deep freezer of capacity 310 liters of any make and replacing the new compressor with reconditioned compressor of the same make of model and re-installing in original position with all accessories like relay with over load protector and recharging of refrigerant including testing for smooth functioning complete all as specified and directed.
195S&F in repairs condensing coil suitable for deep freezer of capacity 320 Liters complete all as specified and directed.
196M&L for shifting of air conditioner split type of any make from its original position to another position with and including any B&R and electric work required for it complete all as specified and directed.
197M&L for removing unserviceable burnt sealed compressor from air conditioner and fixing only new rotary / new sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supplying and charging refrigerant gas including testing complete all as specified and directed. Note:- (a)Sealed unit compressor shall be measured and paid separately as supply only (b)If any item required to made equipment functional like capillary tube, copper pipe, etc is deemed to be included in quoted unit rate.
198Taking out window/split type air conditioner of any make and capacity from position and cleaning the cooling coil and condenser coil with chemical base solution and water including servicing, oiling, greasing air conditioner, checking of electrical connections and re-fixing the same at its original position and testing complete all as specified and directed. NOTE:- All spares such as compressor, fan motor, relay, capacitor, over load, etc shall be measured and paid separately as supply only.
199Supply only newly hermitically sealed/ rotary type compressor of capacity 1.5 TR complete all as specified and directed. Make: Emerson /Tecumesh /Carrier /Hitachi / Blue Star or equivalent as approved by GE.
200Supply only new hermitically sealed / rotary type compressor of capacity 2.0 TR complete all as specified and directed. Make: Emerson /Tecumesh /Carrier /Hitachi / Blue Star or equivalent as approved by GE.
201Supply only FHP motor of capacity 1/5 to 1/18 HP, single phase, 920 RPM with starting and running capacitor suitable for window type AC complete all as specified and directed. Make:- AUL/Air master or equivalent as approved by GE.
202Supply only starting capacitor 80-100 MFD /100-120 MFD /120-150 MFD complete all as specified and directed. Make: Keltronor/Epcos as per recommanded by manufacturer or equivalent as approved by GE.
203Supply only running capacitor 45/50 MFD complete all as specified and directed. Make : EPCOS or as per recommanded by manufacturer or equivalent as approved by GE.
204Supply only starting relay suitable for 1.0 /1.5 /2.0 TR compressor complete all as specified and directed. Make: HI-tech/Classic or as per recommanded by manufacturer or equivalent as approved by GE.
205Supply only rotary/push type selector switch suitable for 1.5/2.0 TR window type AC complete all as specified and directed.
206Supply only thermostat suitable for window / Split type AC complete all as specified and directed. Make : INDFOSS/Godrej or as per recommanded by manufacturer or equivalent as approved by GE.
207Supply only condenser/cooling coil suitable for window/split type AC 1.5 TR of any make and capacity complete all as specified and directed.
208Supply only condenser/cooling coil suitable for window/split type AC 2 TR of any make and capacity complete all as specified and directed.
209Supply only blower fan motor suitable for split AC /window AC of any capacity and make complete all as specified and directed.
210S&F in repairs of remote PCB for a split type AC of any capacity and make complete all as specified and directed.
211S&F in repairs of remote PCB for a split type AC of any capacity and make complete all as specified and directed.
212M&L for rewinding of stator of FHP motor of size 1/5 to 1/18 single phase 920 RPM with super quality of copper wire of existing size with varnishing, backing, testing including painting with one coat of synthetic enameled black paint complete all as specified and directed.
213M&L for charging of refrigerant gas R-22/R-32 in window / split type air conditioners 1.5 / 2.0 TR at site/contractor’s workshop including all necessary work such as cost of refrigerant, welding to refrigerant pipe line, copper pipe, etc and testing complete all as specified and directed.
214Transporting refrigerator of any make and capacity from MES Store Yard/site to contactor’s workshop for carrying out necessary repairs as mentioned in respective item including replacement of un-serviceable spares parts and re-fixing at various locations/ MES store yard after repairing complete all as specified and directed. NOTE:- All spares parts such as compressor, fan motor, relay, capacitor, over load, etc shall be measured and paid separately as supply only.
215M&L in replacement for unserviceable freezer unit of refrigerator capacity 165 / 170 / 175 litres of any make with new freezer unit with door and chill tray including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning complete all as specified and directed.
216All as per item No. 208.00 here-in-before but for refrigerator capacity 286/300/310 Ltrs.
217S&F in repairs thermostat suitable for refrigerator 165 to 310 liters capacity complete all as specified and directed. Make: Danfoss / Indfoss or equivalent as approved by GE.
218M&L for finding out the leakage with the pressure test of the condenser or cooling coil ofrerigerator of capacity 286/310 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including charging thegas R-22/R-134 and testing the water cooler complete all as specified and directed.
219All as per item No. 211.00 here-in-before but for refrigerator capacity 165/170/175 Ltrs
220M&L for removing the unserviceable compressor sealed unit of refrigerator of capacity 286 / 300 / 310 liters of any make and for replacing the compressor with new compressor of same make and model, installing in original position with all accessories like relay with over load protector, filter and recharging of refrigerant including testing for smooth functioning complete all as specified and directed.
221All as per item No. 213.00 here-in-before but for refrigerator capacity 165/175 Ltrs
222M&L for charging of refrigerant gas R-134a for deep freezer /refrigerator/water cooler at site/contractor’s workshop including all necessary work such as cost of refrigerant, welding to refrigerant pipe line, copper pipe, etc and testing complete all as specified and directed.
223M&L for cleaning down body including fitting and fixtures of desert cooler of capacity 4000 / 5000 Cum per hours of any makeincluding removal of all sludges, loose paint dust, dirt, etc and preparing the surface for painting and applying two coats of synthetic enamel paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank including rewriting of MES No. etc complete all as specified and directed.
224M&L for taking out fan motor single phase 230 Volts, 1400 RPM, 3 speed 1/8 HP from desert cooler and rewinding the same with supper enamelled copper wire as per existing gauge and varnishing with “E” class varnish, including replacement of gun metal bushes and reassembling and fixing in position complete all as specified and directed.
225S&F in repairs desert cooler motor of three speed, ISI marked, 1400 RPM, single phase, copper winding motor with ring, side legs, necessary bolts and nuts of capacity 1/8 HP complete all as specified and directed. Make : Usha/ C&G/ Khaithan or equivalent as approved by GE.
226S&F of body of 22 gauge suitable for coolers of capacity 18 guage with water tank complete all as specified and directed.
227S&F in repairs side shutter (set of three) made out from 0.80 mm thick galvanised iron sheet suitable for 4000 Cum / hrs capacity desert cooler complete all as specified anddirected.
228S&F in repairs front grill / louvers to desert cooler made out from 0.8 mm thick GI sheet suitable for 5000 /4000 Cum / hrs capacity desert cooler of any make complete all as specified and directed.
229S&F in repairs PVC flexible pipe 16 mm outer dia with bends for desert cooler with PVC elbow complete all as specified and directed.
230S&F in repairs selector switches three way, 230 Volts single phase of standard quality fixed in desert coolers complete all as specified and directed.
231S&F in repairs wood pad (set of three), minimum weight 0.8 Kg, fixed in side panels of desert coolers complete all as specified and directed.
232S&F in repairs sumbesable pump 230 Volts, 1/60 HP, ISI marked for desert cooler including pump support plate fabricated with 0.4 mm thick GI sheet with fixing screws, nuts and bolts complete all as specified and directed. Make : Khaitan/Polar/GEC or equivalent as approved by GE.
233S&F in repairs capacitor 4 MFD for fan motor of desert cooler complete all as specified and directed. Make:-EPCOS/ SYSCAP/ ASIAN or equivalent as approved by GE.
234S&F in repairs iron fan blade powder coated for fan motor of desert cooler 20 inch sweep complete all as specified and directed.
235Deduct Schedule of credit (calculation will be done off line) Rs. 160277.00
Disclaimer :