Tender For Provision Of Defi Md Accommodation At Mil Station Gandhinagar (Job No 003/Amwp/12C/2022-23), gandhinagar-Gujarat

Military Engineer Services-MES has published Tender For Provision Of Defi Md Accommodation At Mil Station Gandhinagar (Job No 003/Amwp/12C/2022-23). Submission Date for this Tender is 14-12-2023. Brushes Tenders in gandhinagar Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

40344331
Corrigendum : Tender For Provision Of Defi Md Accommodation At Mil Station Gandhinagar (Job No 003/Amwp/12C/2022-23)
Open Tender
Indian
Gujarat
gandhinagar
14-12-2023

Tender Details

Tender For Provision Of Defi Md Accommodation At Mil Station Gandhinagar ( Job No 003 / Amwp / 12C / 2022-23 ) ; 1 Lump Sum Price Worked Out By The Contractor For Building WorksAs Listed In Schedule ‘A’ Part-I Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Price Prepriced By The Mes B / F From Sl Page No.27 2 Lump Sum Price Worked Out By The Contractor For Site Clearance, Development, Excavation & EarthworkAs Listed In Schedule ‘A’ Part-Ii Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Price Prepriced By The Mes B / F From Sl Page No. 28 3 Lump Sum Price Worked Out By The Contractor For Internal Water Supply As Listed In Schedule ‘A’ Part-Iii Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes B / F From Sl Page No. 29 4 Lump Sum Price Worked Out By The Contractor For Internal ElectificationAs Listed In Schedule ‘A’ Part-Iv Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes B / F From Sl Page No.33 5 Lump Sum Price Worked Out By The Contractor For Road, Path, Culvert As Listed In Schedule ‘A’ Part-V Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes B / F From Sl Page No.36 6 Lump Sum Price Worked Out By The Contractor For Area DrainageAs Listed In Schedule ‘A’ Part-Vi Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes B / F From Sl Page No.37 7 Lump Sum Price Worked Out By The Contractor For Sewage DisposalAs Listed In Schedule ‘A’ Part-Vii Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceof Prepriced By The Mes B / F From Sl Page No.39 8 Lump Sum Price Worked Out By The Contractor For External Water SupplyAs Listed In Schedule ‘A’ Part-Viii Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes B / F From Sl Page No. 40 9 Lump Sum Price Worked Out By The Contractor For External ElectrificationAs Listed In Schedule ‘A’ Part-Ix Representing Percentage ( + Or - Denomination ) Derived Under Last Column Of This Schedule Above / Belowthe Lump Sum Priceprepriced By The Mes B / F From Sl Page No. 42 10 Sch A Part-Xi ( Miscellaneous Items ) Notes: ( I ) This Schedule Is Not Pre-Priced By Mes And The Pre-Priced Rate Indicated As Rs 0.00 Under Column 5 Signifies This Fact Only. ( Ii ) Excavation And Earth Work Except For The Items Which Categorically Includes For Same Shall Be Measured And Paid Separately Under Respective Schedule. 11 Internal Water Supplys&F 15Mm Bore Cp Brass Bib Cock Screwed For Iron Pipe Of Ferrule And Fixed Complete All As Specified And Directed.Make -Jaquar Queen Series Cat No Qqt-7037 Or Technocommercial Equivalent Makes As Per Appx C. 12 Internal Electrificationss&F Tv Sockets Complete With All Accessories Complete All As Specified And As Directed. 13 S&F Rj 11 Gang With Shutter ( Telephone Jack ) Complete With All Accessories Complete All As Specified And As Directed. 14 Supply & Fixpvc Metal Braided Connection Pipes For Hot Water Supply With Brass Adopters 15 Mm Dia And 450Mm Long Complete All As Specified And As Directed. 15 S & F Led Batten Suitable For Indoor Application 20 W, 4 Length , Wall Mounted With Aluminium Housing, End Cap Made Of Abs Plastic Of White Colour Finish And High Efficiency Translucence ( Het ) Diffuser And Integral Electronic Driver Including Two Point Surface Mounting On Wall / Ceiling And Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable Of Suitable Sizecomplete All As Specified And As Directed 16 Supply And Fixing Load Line Distribution Board Tpn Vertical, 4 Way Double Door Type, Fixed On Wall Semi Flush With Incoming Mccb 4 Poles 125 Amps, 16 Ka, Busbars , Neutral Link, Blanking Plates Complete With All Accessories All As Specified And As Directed By Engineer-In-Charge. Note: Outgoing Mcbs Shall Be Measured And Paid Separately 17 Supply & Fix Led Lampb22 Base 10 W, Min Lumen Output 950 Lumens At 6500 K Cct With Batten Lamp Holderscomplete All As Specified And As Directed. 18 Supply And Fixing Led Light Fitting Mirror Type With High Out Put Diffuser 2 Feet, 10 Watt 220 V Ac Decorative Type With Driver Holder And Led Lamp Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete With Twin Core Twisted Flexible Copper Conductor Cable Of Suitable Sizecomplete All As Specified And As Directed 19 M & L For Inverter Point Wiring For One Light, Ceiling Fan And 5 Amp Socket For Each Roomwith 2.5 Sqmm, Pvc Insulated, Unsheathed, Single Core Multistandard Copper Conductor Cable ( Frls ) , 1100 Volts Grade Including 2.5 Sqmm Pvc Insulated, Unsheathed, Copper Conductor Cable For Earth Continuity Wire To Be Drawn Through In And Including Pvc Conduit Medium Grade Isi Markedwith Its Accessories Upto The Main Dband 15 A Switch Socket Combination With Gang Box Flushed In Wallfor Inverter Power Supplycomplete All As Specified And As Directed. 20 M&L For Earthing Complete With Galvanised Steel Earth Electrode 60 Cm X 60 Cm X 6 Mm Buried Directly In Ground Vertically To Depth Not Less Than 2.25 M Below Normal Ground Level With Top Edge Of The Earth Plate At A Depth Not Less Than1.5 M Below Ground Level Connected To And Including Gi Earth Lead Wire 4 Mm Dia By Meansof Nuts, Bolts, Check Nuts And Washer Etc, Made Of Gi And Connected To Test Point And Earth Dolly All As Shown In Electrical Plate No. 3 Ssr Part-I 2009 And Specified Or Indicated Including Excavation And Earthwork In Any Type Of Soil Pcc ( 1:3:6 ) Type C1 In Chamber, Precast Rcc 50 Mm Thick In Cement Concrete ( 1:2:4 ) Type B1, Reinforced With Welded Steel Wire Fabric Or Xpm ( Weight Not Less Than 4.00 Kg / Square Metre ) With Cast Iron Frame, Funnel With Wire Mesh, 20 Mm Bore Medium Grade Gi Watering Pipe, Lugs, 15 Mm Bore Medium Grade Giprotection Pipe, Test Point Etc. Complete All As Specified And Directed. Note:- ( I ) Item Includes The Cost Of 7.5 Metre Gi Pipe For Protection Of Earth Lead. ( Ii ) Item Includes The Cost Of 7.5 Metre Gi Earth Lead. 21 M&L For Earthing Complete With Galvanized Steel Earth Plate Electrode 60 Cm X 60 Cm X 6 Mm Thick, Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metres Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level, Connected To And Including Earth Lead Of Galvanized Strip 32 X 6 Mm By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Or Steel All As Shown In Electrical Plate No. 3 Of Ssr Part-I With Connected To Earth Test Point & To Main Switch Board With & Including Adequate Quantity Of Charcoal And Common Salt Alround Earth Plate & 15 Mm Dia Gi Pipe Medium Grade For Earth Lead Protection Pipe Fpr Suitable Length And Gi Pipe 20 Mm Dia Medium Grade For Watering Pipe With Funnel & Wire Mess Including Necessary Earth Work And Pcc ( 1:3:6 ) Type C1 For Earth Pit And 40Mm Thick Precastrcc Cover In Cement Concrete 1:2:4 Type B1, With 3 Nos 8Mm Dia Tmt Bars Both Ways With 12Mm Dia Round Bar Handle Complete All As Specified And Directed Note: Item Includes The Cost Of Earth Lead And Gi Protection Pipe Up To 7.5 M.Gi Strip And Protection Pipe Beyond 7.5 M Shall Be Measured And Paid For Separately. 22 M & L For Drawing 12 Pair / Multi Core Coated Copper Telephone Cable Including Pvc Conduit Of Size 20Mm Complete All As Specified And As Directed. 23 M &L Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit / Pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etcas Required 4Mm Complete All As Specified And Directed. 24 Supply And Fix Hot Water Pipe Duly Insulated With Glass Wool And Aluminium Cladding Complete In All Respect Of Size 20Mm Bore All As Specified At Site Complete All As Specified And Directed. 25 S & F 30 W Led Security Light Fitting Made Out Of Pressure Die Cast Aluminium Powder Coated Housing High Impact Resistant 4Mm Thick Toughened Glass Cover And Matrix Of Power Ledsinbuilt Electronic Driver Up To 4Kv Surge Protection Fitted With Adjustable Pole Adapter To Enable On Site Tilt Angle Setting Depending On Road Geometry Cct5500-6500 Cri Greater Than 70 , Input Power 30Woutput Operating Voltage 140-280V With Connection By Three Core Pvc Insulatedmultistranded Copper Conductor Sheathed Cable Of Size 1.0 Sq Mmfixed With & Including Bracket Made Of Gi Pipe 40Mm Bore Light Grade, 1.6 Mtr Long Bent To Shape Required With 2 No Ms Clamps Of Suitable Size And Length, Nuts & Boltscomplete All As Specified And As Directed. 26 M&L For Sub Main Wiring With Two Runs Of 4.0 Sqmmsize Main Cable And One Run Of 4.0 Sqmm Size Earth Continuty Conductor Of Single Core Pvc Insulated But Unsheathed Frls Cable Multi Standed Copper Conductors, 1100 Volts Grade, Is-694 Marked All Drawn Through And Including Suitable Size Rigid Pvc Conduit Pipe Medium Grade Isi Marked & Fittings / Accessories All Fixed To The Surface Of Wall / Ceiling Complete All As Specified And As Directed 27 M&L For Sub Main Wiring With Two Runs Of 6.0 Sqmmsize Main Cable And One Run Of 6.0 Sqmm Size Earth Continuty Conductor Of Single Core Pvc Insulated But Unsheathed Frls Cable Multi Standed Copper Conductors, 1100 Volts Grade, Is-694 Marked All Drawn Through And Including Suitable Size Rigid Pvc Conduit Pipe Medium Grade Isi Marked & Fittings / Accessories All Fixed To The Surface Of Wall / Ceiling Complete All As Specified And As Directed 28 M&L For Sub Main Wiring With Four Runs Of 10.0 Sqmmsize Main Cable And One Run Of 10.0 Sqmm Size Earth Continuty Conductor Of Single Core Pvc Insulated But Unsheathed Frls Cable Multi Standed Copper Conductors, 1100 Volts Grade, Is-694 Marked All Drawn Through And Including Suitable Size Rigid Pvc Conduit Pipe Medium Grade Isi Marked & Fittings / Accessories All Fixed To The Surface Of Wall / Ceiling Complete All As Specified And As Directed 29 Note For Item No 26.00 To 28.00: The Above Mentioned Specefied Runs Of Single Core Cables And Specefied Runs Of Earth Continuity Conductors And The Relevant Conduit With Accessories Shall Be Measured As One Runs Length.The Small Extra Lengths Required For Loops Etc For Connection In Dbs Shall Deemed To Be Included In Quoted Rate And Only The Cable Covered In Conduit Shall Be Measured. 30 Road & Foot Pathm&L For 150 Mm Thick Wmm ( Wet Mix Macadam ) ( Compacted Thickness ) Laid In Two Layers Of 75Mm Thick Each Conforming To Grading Given In Table 400-13 & Physical Requirement Given In Table 400-12 Spread By Mechanical Means & Rolled By Using 8-10 Ton Vibrator Power Roller Over Compacted Sub Grade Surface Of Soling As Specified In Clause 406 3.5 Of Morth Specification And Necessary Lateral Support And Formwork If Required Complete All As Specified And Directed. 31 M&L For Cement Concrete Bed To Drain Pipes In Pcc 1:3:6, Type C2 ( Using 40Mm Graded Stone Aggregate ) , For 450Mm Bore Drain Pipe Including Packing Under And Haunching Against The Sides Of Pipes With Concrete After They Are Laid And Tested Complete All As Specified And Directed. 32 External Water Supplysupply, Installation, Connecting And Testing Sluice Valve, Non Rasing Type Spindle, Cast Iron Body & Wedge With Bronze Wedge Ringon Both Side, Gland Packing, Class - Pn 1.6 With Flanged Ends Drilled Suitable For Bore Of Pipe 100 Mm Isi Marked ( Is:14846:2000 ) Having S.S. Spindle With Iron Wheel At Top, Complete With Nuts Bolts Washers Rubber Gasket Etc All As Specified And Directed. 33 M&L For Cutting Of Existing Ci / Di / Gi Pipe And Insterting And Including Tee Of Size 100Mm X100mm X100mmfor Making Suitable Connection Complete All As Specified And Directed.Note:- Quoted Unit Rate Of This Item Includes The Cost Of Excavation And Earth Work And Refilling Required For Completion Of Job. 34 External Electrificationssupplying, Installing, Testing And Commissioning Of Ac 3 Phase, 50 Hz, 160 Kva Capacity Transformer, Step Down, Outdoor Type, 11000 / 433 Volts ( At No Load ) With System Voltage 12Kv All As Per Is 1180 ( Part 1 ) :2014, Copper Wound, Oil Immersed, Naturally Cooled With External Cooling Tubes, Onan Cooling, Core Type, Delta Connected On Primary ( Hv ) Side And Star Connected On Secondary ( Lv ) Side In Accordance With Vector Symbol Dyn-11 ( Vector Group-4 ) With Neutral Brought On Secondary ( Lv ) Side & Having Tappings In Equal Steps Of 2.5 % From ( + ) 5% To ( - ) 10% On Primary Side By Means Of Hand Operated Off Load Tap Changing Gear, So As To Change / Correct L.T Voltage On Secondary Side Including Provision Of All Necessary / Standard Fittings All As Per Is:2026 & Iec 76 Latest Ammendments And Confirming To Bee 5 Star Rating ( Level 3 Transfomer ) As Per Is 1180 ( Part 1 ) :2014 35 ( A ) The Core Shall Be Stack / Wound Type Of High Grade Cold Rolled Grain Oriented Or Amorphous Core Annealed Steel Lamination Having Low Loss And Good Grain Properties, Coated With Hot Oil Proof Inter Layer Insulation Of Nomex / Epoxy Dotted Kraft Paper, Bolted Together And To The Frames Firmly To Prevent Vibration Or Noise. The Core Shall Be Stress Relieved By Annealing Under Inert Atmosphere If Required.The Complete Design Of Core Must Ensure Permanency Of The Core Loss With Continuous Working Of The Transformers. Lv Winding Shall Be Such That Neutral Formation Will Be At Top. Current Density For Hv And Lv Winding Should Not Be More Than 2.8 Ampere Per Sq Mm. ( B ) The Maximum Allowable Losses At 75 °C For 11 / 0.433 Kv At 50% Of Rated Load And Total Losses At 100% Of Rated Load Shall Not Exceed The Maximum Total Loss 416 Watts And 1281 Watts Respectively Without Any Positive Tolerance All As Per Specified In Is 1180 ( Part-1 ) :2014 For Energy Efficient Rating 5Star. ( C ) Overload Capacity Of Transformers Shall Be Suitable For Loading As Per Is 6600 ( D ) The Percentage Impedance Of Transformers At 75 °C For 160 Kva Shall Be As Per Table 6 Of Is 1180 ( Part-1 ) : 2014 36 ( E ) Transformer Tank Construction Shall Conform In All Respect To Clause 15 Of Is 1180 ( Part-1 ) :2014. The Internal Clearance Of Tank Shall Be Such, That It Shall Facilitate Easy Lifting Of Core With Coils From The Tank Without Dismantling Lv Bushings. All Joints Of Tank And Fittings Shall Be Oil Tight And No Bulging Should Occur During Service. Inside Of Tank Shall Be Painted With Varnish / Hot Oil Resistant Paint.The Top Cover Of The Tank Shall Be Slightly Sloping To Drain Rain Water. The Tank Plate And The Lifting Lugs Shall Be Of Such Strength That The Complete Transformer Filled With Oil May Be Lifted By Means Of Lifting Shackle.Manufacturer Should Carry Out All Welding Operations As Per The Relevant Asme Standards. The Transformer Tank Shall Be Of Robust Construction And Shall Be Built Up Of Electrically Tested Welded Mild Steel Plates Of Thickness Of 6 Mm For The Bottom And Top And Not Less Than 4 Mm For The Sides For Distribution Transformers With Tolerances As Per Is-1852.The Space Above Oil Level In The Tank Shall Be Filled With Dry Air Or Nitrogen Conforming To Commercial Grade Of Is 1747. The Tank Shall Further Be Capable Of Withstanding A Pressure Of 0.8Kg / Sq.Cm And A Vacuum Of 0.7 Kg / Sq.Cm ( G ) Without Any Deformation. ( F ) Audible Sound Levels For 160Kva, 50Hz Liquid Immersed Distribution Transformers Shall Be 56 Decibels ( Nema Standards ) ( G ) One Cable Box On Primary H.V Side Having Cable Glands Suitable For 95 Sqmm 3 Core Xlpe 11 Kv H.T Cable Consisting Of 3 Nos Porcelain H.T Bushings With Brass / Gun Metal Bushing Rods Confirming To Is 2099 And Is 3347 For Outdoor Bushing Complete With Nuts And Washers.Ht Cable Box Should Prevent The Ingress Of Moisture Into The Box Due To Rain Water Directly Falling On The Box. The Cable Box On Ht Side Shall Be Of The Split Type With Faces Plain And Machined And Fitted With Neo-K-Tex Or Similar Quality Gasket And Complete With Brass Wiping Gland To Be Mounted On Separate Split Type Gland Plate With Nut-Bolt Arrangement And Ms Earthing Clamp. The Bushings Of The Cable Box Shall Be Fitted With Nuts And Stem To Take The Cable Cores Without Bending Them. The Stem Shall Be Of Copper With Copper Nuts. The Cross Section Of The Connecting Rods Shall Be Stated And Shall Be Adequate For Carrying The Rated Currents. On The Hv Side The Terminal Rod Shall Have A Diameter Ts For 3 Phase Dt 11 Of Not Less Than 12 Mm. The Material Of Connecting Rod Shall Be Copper. Ht Cable Support Clamp Should Be Provided To Avoid Tension Due To Cable Weight. 37 ( H ) One Cable Box On Secondary ( Lv ) Side Consisting Of 4 Nos Porcelain Bushings Complying To Is 7421 With Gmbushing Rods Complete With Gm Nuts, And Washers With Cable Gland Suitable For Reception Of Outgoing L.T. Pvc Sheathed Armoured Cables Of Size 2 X 300 Sqmm 3.5 Core . Having Non-Magnetic Material Gland Plate With Appropriate Sized Single Compression Brass Glands On Lv Side To Terminate 1.1 Kv / Single Core Xlpe Armoured Cable. ( J ) The Bushing Rods And Nuts Shall Be Made Of Brass Material 12 Mm Diameter For Both Ht And Lt Bushings. The Bushings Shall Be Fixed To The Transformers On Side With Straight Pockets And In The Same Plane Or The Top Cover . The Tests As Per Latest Is 2099 And Is 7421 Shall Be Conducted On The Transformer Bushings. ( K ) Oil Conservator:The Provision Of Conservator Is Mandatory With Oil Gauge, Air Release Plug Andbreathing Device With A Drain Plug And A Filling Hole 32 Mm ( 1¼” ) Normal Size Thread With Cover. The Dehydrating Agent Shall Be Silica Gel. The Moisture Absorption Shall Be Indicated By A Change In The Colour Of The Silica Gel Crystals Which Should Be Easily Visible From A Distance. Volume Of Breather Shall Be Suitable For1kg Of Silica Gel Conforming To Is 3401. The Total Volume Of Conservator Shall Be Such As To Contain 10% Quantity Of The Oil. Normally 3% Quantity The Oil Shall Be Contained In The Conservator. ( L ) The Radiators Can Be Tube Type Or Fin Type Or Pressed Steel Type To Achieve The Desired Cooling To Limit The Specified Temperature Rise. ( M ) Transformer To Be Painted With Poly Urethene / Powder Caoted ( Color Light Gray & Da Gray ) Paints Over Anti Corrosive Primer & Shall Be Free From Runs, Sags, Wrinkles, Patchiness, Brush Marks Or Other Defects.All Primers Shall Be Well Marked Into The Surface, Particularly In Areas Where Painting Is Evident And The First Priming Coat Shall Be Applied As Soon As Possible After Cleaning. The Paint Shall Be Applied By Airless Spray. 38 ( N ) One No 100 Mm Dia Dial Type Thermometer Vapour Pressure Type Having Range 0-120 Degree Centigrade With Temp Reading Pointer, Maxtemp Indicator And Resetting Device ( O ) Rating Plate With Terninal Markings. ( P ) Two Earthing Terminals On Tank / Tank Cover To Facilitate Fixing Of 32 X 6 M Gi Earth Strip. ( Q ) Lifting Lugs. ( R ) Four Plane Solid Cast Steel Detachable Rollers. ( S ) First Fill Of Fresh Transformer Oil Conforming To Is-335, Bs148, D-1473, D-1533-1934Iec Pub296 And Tested Upto 40 Kv Dielectric Strength. Use Of Recycled Oil Is Not Acceptable. The Specific Resistance Of The Oil Shall Not Be Less Than 2.5X10¹² Ohm-Cm At 27°C When Tested As Per Is 6103. ( T ) Extra Bushing For Neutral Outside The L.T Cable Box For Providing Independent Earthing For Neutral. ( U ) Provision Of 2 Nos Danger Boards 250 X 200 Mm Size Made Out Of 1.6 Mm Thick M.S. Plate, Vitreous Enameled White, With Letters. Figures Of Voltage And Conventional Skull And Bones Insignal Red Colour , One At H.T Side And Other On L.T Side. ( V ) Any Other Fittings / Accessories So As To Conform The Whole Transformer Tois 1180 ( Part 1 ) : 2014 39 ( W ) The Distributiontransformers To Be Supplied Against This Specification Shall Be Suitable For Satisfactory Continuous Operation Under The Following Climatic Conditions As Per Is 2026 ( Part-I ) : ( I ) Location:Ahmedabad ( Ii ) Maximum Ambient Air Temperature ( °C ) :50 °C ( Iii ) Minimum Ambient Air Temperature ( °C ) :5°C ( Iv ) Maximum Average Daily Ambient Air Temperature ( °C ) :42 °C ( V ) Maximum Yearly Weighted Average Ambient Temperature ( °C ) : 32 °Cthe Temperature Rise Over Ambient Shall Not Exceed The Limits Given Below: ( I ) Top Oil Temperature Rise Measured By Thermometer : 35 °C ( Ii ) Winding Temperature Rise Measured By Resistance Method : 40 °C 40 Construction Of Brick Masonry Platform In Cement Mortar 1:4 Of Size 2400 X 1800 X1200 Mm For Outdoor Type Transformer Having Sides Finished With Brick Work With Plaster Complete With Pcc Foundation Of 1:5:10 & Pcc Platform At Top With 30 Cm Thickof Pcc 1:5:10 And 10 Cm Thick Of Pcc 1:2:4 And Having Brick Steps At One Side, Complete With Xpm Jali Duly Welded With Angle Iron Of Size 50 Mm X 50 Mm X 6 Mm All Around Upto 0.6 Metre, Including Excavation And Earth Work In Any Type Soil , Returning Filling In And Removal Of Surplus Soil Upto 50 Metre Complete All As Shown On Drawing Or As Directed. 41 M&L For Complete Set Ofled Street Light Fitting 60 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminum Hosing, Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65 / 66 Protection Fixed To Pole Complete Comprising Of The Followings:- 42 ( I ) Bracket Made Out Of Light Grade, Galvanised Steel Tube, 40Mm Bore, 1.5 Mtr Length, Bent To 120 Degree For Fixing Street Light Fitting At The Top, Fixed To Pole With Necessary Clamps Made Out Of Fi 40Mm X 4Mm With Nuts & Bolts ( Ii ) Sintex Juction Box Of Size 230X170x105mm Compete With Onesp Mcb Of 6 Amps ( Iii ) Pvc Insulated, Sheathed Copper Conductor Cable Of Size 1.5 Sqmm, 3 Core, 1100 Volts Grade, Multistranded, Passing Throuth Pipe, Fixed On Pole / Wall From Juntion Box To Street Light Fitting 43 Supply, Installation, Commissoning And Testing, Feeder Pillar Board, Kiosktype, Lt ( 415 Volts, 50 Hz , 3-Phase, 4 Wire Supply ) , Plinth Mounted, Factory Made, Outdoor Type, Weather And Vermin Proof ( Protection Class Ip-54 ) Made Out Of 50Mm X 50Mm X 5Mm Angle Iron Frame And 3.15 Mm Thick Ms Sheet Crca Sheet Powder Coated With Front & Back Hinged Opening, Rubber Lining, Locking Arrangement, Painted Externally And Internally With Two Coats Of Synthetic Enamel Gray Paint ( First Quality ) Over A Coat Of Red Oxide Primer, Grouting Panel Through Angle Iron, 0.20 Mtr In Ground And 0.5 Mtr Over The Ground Including Excavation & Earth Work In Any Type Of Soil And Pcc ( 1:3:6 ) Type C-2 Using 40Mm Graded Stone Aggregate Complete Comprising Of The Followings:- 44 Incoming Supply :- ( I ) Aluminium Bus Bar Chamber 200 Amps Rating Of 04 Strip - 01 No ( Ii ) Mccb, Thermal And Megnatic Setting, 4 Pole, Ac, 415 Volts, 125 Amp Rating, 25 Ka Rupturing Capacity - 01 No ( Iii ) Digital Type Multifunctional Metershowing Pf, V, I, Hz Etc. - 01 No ( Iv ) Indicatiing Lamp Neon Type For R-Y-B - 3 Nos. ( B ) Outgoing Supply:- ( I ) Mccb, Thermal And Meganitic Setting, 3 Pole, Ac, 415 Volts, 63 Amp Rating, 16 Ka Rupturing Capacity - 04 No ( Ii ) Cable Connection Through Straight Plugs 63A, 415 Volt - 04 Nos Cat No. 058705 Tempra Pro Ip-67 And Panel Mounting Socket 63 Amp, 415 Volt - 04 Nos Cat No. 058725 Tempra Pro Ip-67. 45 Supply Installtion Testing Andcommissioning ( Sitc ) Of Indoor Type Factory Made Automatic Power Factor Correction ( Apfc ) Of Capacity 80 Kvar Fabricated Out Of 2Mm Thick Ms Sheet, Openable Front Fitted With Low Watt Loss Capacitors To Improving Power Factor, Suitable For 415 Votls, 50 Hz, 3 Phase, 4 Wire With And Including The Following :- ( A ) Digital Multi Functional Meter Showing Current, Voltage, Power Factor, Frequency With Suitable CtS Ratio - 01 No ( B ) Indicators Ryb - 1 Set ( C ) Capacitor Step On Indication Lamps - 04 Nos ( D ) Auto-Manual Selector Switch - 01 No ( E ) On / Off Push Buttons For Manual Mode-01Set 46 ( F ) Micro Processor Based Apfc Relay 4 Steps Having All The Required Features-01 No ( G ) Mcb Tp 16 Amp - 04 Nos ( H ) Aluminium Busbars Of Suitable Capacity Tpn-01 Set ( J ) Internal Wiring Of Panel Board With Copper Cable. ( K ) Mccb 25Ka / 3 Pole, 50 Hz, 160 Amp-01 No ( L ) 2.5 Sqmm 2 Core Lt Armored Cable For Connection Of Main Panel Ct With Apfc Panel ( M ) Lt Power Capacitor Cylindrical Capacitor 20 Kvar, 440 Volts, 3 Phase, 50 Hz-01 No ( N ) Capacitor Duty Contactor Capacity 40 Kvar, 415 Votls, 3 Phase, 50 Hz-01 No ( O ) Capacitor Duty Contactor Capacity 10 Kvar, 415 Votls, 3 Phase, 50 Hz-02 Nos 47 Supply, Installation, Commissoning And Testing, Lt Panel Board, Cubical Type, ( 415 Volts, 50 Hz , 3-Phase, 4 Wire Supply ) , Floor Mounted, Factory Made And Tested, Outdoor Type, Weather And Vermin Proof ( Protection Class Ip-54 ) Made Out Of 40Mm X 40Mm X 6Mm Angle Iron Frame And 3.15 Mm Thick Ms Sheet Crca Sheet With Front & Back Opening Type Of Adequate Size For Housing Lt Switchgear Ahd Measuring Instrumentsdulypowder Coated After Seven Tank Process On Both Sides Incl Internal Wiring In The Panel With Suitable Size Of Pvc Multistranded Copper Cable 1100 Volts Grade Is-694 And Complete Comprising Of The Followings:- 48 Bus Bar 400 Amps. 4 Pole Aluminium ( 50 Kv ) ( A ) Incoming Supply:- ( I ) Mccb, Thermal Magnetic Seting, 4 Pole, Ac, 415 Volts, 320 Amp Rating, 35 / 36 Breaking Capacity, 50 Hz - 01 No ( Ii ) Led Indicatiing Lights For R-Y-B - 01 Set ( Iii ) Panel Mounted Multifunction Meter Suitable To Operate On And Incl Ct In Accuracy Class 1.0, Suitable 3 Phase Ct Network Ct Primary Programmable, Three Line Baklit Display Of Phase To Phase Rating Phase To Neutral Voltage Current Active Power Kw, Kvar, Kva, Pf Frequancy. ( B ) Outgoing Supply:- ( I ) Mccb, Thermal And Meganitic Setting, 4 Pole, Ac, 415 Volts, 100 Amp Rating, 25 Ka Breaking Capacity - 05 No ( C ) Time Switch Auto Dusk Dawn ( Nature ) 3 Phase Including Connection For Operation Of 20 X 60 Watt Lights. 49 Supplying, Installing, Testing And Commissioning, Of Factory Made Lt Meter Box, Wall Mounted Board Made Out Of Crca Sheet Of 2Mm Thick Indoor Type Totally Enclosed Weather, Dust And Vermin Proof With Front Opening Hinged Door And Locking Arrangement Mounted On Ms Flat Iron ( 40X6mm And 6 Long ) 04 No Clamp Welded To 40Mm X 40Mm X 6Mm Size Angle Iron Frame Alround Panel Duly Grouted On Wall, 415 Volts, 3 Phase, 4 Wire Ac 50 Hz Having Aluminium Bus Bar For Phase And The Neutral Insulated With Pvc Sleeves, Space For Fixing Single Phase Kwh Electric Meter Of Suitable Capacity 04 Nos, Copper Lugs, Spacers, Mounting Channels, Rubber Gasket, Locking Knobs, Hylam Sheet Pieces, Nuts And Bolts, Washers Etc. And Suitable Size Single Core Copper Wire Connections Suitable Compartments And Epoxy Powder Spray Paint With Primer Complete All As Specified Including The Following Accessories:- 50 Incoming - ( A ) Mccb 415 Volts, 4 Pole, 25 Ka Breaking Capacity Of 125 Amps - 01 No ( B ) R-Y-B Phase, Led Indicating Lamp - 03 Nos ( C ) 20A / 4Amps Hrc Control Fuse With Fuse Link - 03 Nos ( D ) 150 Amp Main Aluminium Bus Bar. Multifunction Meter With Suitable Ct. Outgoing - ( A ) Mcb, Spn, 63 Amp, 10 Ka - 04 Nos ( B ) Space For Mounting Single Phase Energy Meter-04 Nos ( C ) Copper Cable 10 Sqmm Wire And Open Terminals For All Feeders.Note : Quarter No To Be Mentioned In Respective Meter On Aryclic Plate & Cost Of Aryclic Plate To Be Included In Quoted Rate. 51 M&L For Sand Cushioning To Cables With Tibba Sand And Punning To Provide Required Cover To Ug Cables Complete As Per Ssr Part-I All As Specified And Directed.Note: Punned Down Thickness Shall Only Be Measured And Paid. 52 Supply And Installation Of Ring Main Unit One Incoming Two Outgoing Sf6 Filled Loadbreak Switch Each Of 11 Kv, 3Phase, 50 Cycles, Totally Enclosed Metal Clad Sf6 Switchgear Having Rupturing Capacity Upto 350 Mva Overload And Earth Faulth Protection, Ammeter, Voltmeter And Of Rating Up To 630 Amp Complete All As Per Specified And Directed. 53 S & F Cable Route Indicator For Ht, 6Mm Thick Ci Plate Of Size 100Mm Dia Welded To Ms Angle Iron 50Mm X 50Mm X 6Mm Embedded In Pcc 1:3:6 Type C-1 Block Size 150Mm X 150Mm X 160Mm Complete All As Specified And Directed. 54 M&L For Horizontal Boring By Using The Trenchless Technology Under The Road At Least 60 Cm Below Road Top, In Any Type Of Soil For Insertion Of Gi Pipeof 80Mm Bore. Complete All As Specified And Directed. 55 Arboriculturedigging Of Pit N. Exc 0.25 Cum In Any Type Of Soil Including Removal And Filling Back Tp Pit With Suitable Growing Media Like Red Earth By Treating With Farm Yead Manure In The Ratio ( 3:1 ) Fertilizers And Pesticides ( I.E. Bevation And Neem Cake Bhc 10% Linson Dust. Thimment Or Phorate, Manure Super And Vermicompost ) And Making Up The Trench Area To Proper Level Including Supply And Planting Tree Plants Of Species Of Height Not Less Than 3 Feet As Neem ( Azadiracha Indica ) Complete All As Specified And Directed. 56 Ditto All As Per Item No 44.00 Hereinbefore But Gulmohar ( Delonix Regia ) 57 Ditto All As Per Item No 44.000 Hereinbefore But Peepal Tree ( Ficus Religiosa ) 58 Ditto All As Per Item No 44.000 Hereinbefore But Banyan ( Ficus Benghalensis ) 59 Ditto All As Per Item No 44.000 Hereinbefore But Pink Cassia ( Cassia Javanica ) 60 Ditto All As Per Item No 44.000 Hereinbefore But Christmas Tree ( Araucaria Heterophylla ) , 61 Ditto All As Per Item No 44.000 Hereinbefore But Golden Cane Palm ( Dypsis Lutescens ) , 62 Ditto All As Per Item No 44.000 Hereinbefore But Royal Palm ( Roystonea Regia ) 63 Ditto All As Per Item No 44.000 Hereinbefore But Foxtail Palm ( Wodyetia Bifurcata ) 64 Ditto All As Per Item No 44.000 Hereinbefore But False Ashoka ( Monoon Longifolium ) 65 Maintenance Of Planted Trees And Lawn Area Grass For Two Year After Certified Date Of Completion Issued By Ge, By Employing One Experienced Mali Per Day. The Maintenance Shall Includes The Following. ( A ) Periodical De-Weeding Of Unwanted Vegetation Growth Around The Plants / Lawn Area ( B ) Watering All The Trees / Plants / Grass And Soil With Required For Proper Growth. ( C ) Periodical Prunning The Shrubs. ( D ) Periodical Lawn Mowing. ( E ) Treating The Trees / Plants Grass And Soil With Required Quantity Of Approved Manure, Pesticides And Fertillizer Including Necessary Toping Of Red Earth. ( F ) Replacement Of Dried / Dead Plants / Grass / Trees. ( G ) Hose Pipe To Be Arranged By The Contractor. ( H ) Water Shall Be Supplied By Deptt Free Of Cost Only For Watering To Plants.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Nov-2023 Date Date 30-11-2023
2 23-Nov-2023 Corrigendum No 2 Date 07-12-2023
3 30-Nov-2023 Corrigendum No 03 Date 14-12-2023

Key Value

Document Fees
INR 3000 /-
EMD
INR 1000000.0 /-
Tender Value
INR 13.50 Crore /-

BOQ Items

Name of Work:PROVN OF DEFI MD ACCN AT MIL STN GANDHINAGAR (JOB NO : 003/AMWP/12C/2022-23)
Sl. No. Item Description
1Lump sum price worked out by the contractor for "BUILDING WORKS"as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No.27
2Lump sum price worked out by the contractor for "SITE CLEARANCE, DEVELOPMENT, EXCAVATION & EARTHWORK"as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 28
3Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY "as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 29
4Lump sum price worked out by the contractor for "INTERNAL ELECTIFICATION"as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No.33
5Lump sum price worked out by the contractor for "ROAD, PATH, CULVERT" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No.36
6Lump sum price worked out by the contractor for "AREA DRAINAGE"as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No.37
7Lump sum price worked out by the contractor for "SEWAGE DISPOSAL"as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES B/F from Sl page No.39
8Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY"as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 40
9Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION"as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 42
10Sch "A" PART-XI (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule.
11INTERNAL WATER SUPPLY S&F 15mm bore CP brass bib cock screwed for iron pipe of ferrule and fixed complete all as specified and directed. Make -Jaquar QUEEN SERIES Cat No QQT-7037 or technocommercial equivalent makes as per Appx "C".
12INTERNAL ELECTRIFICATIONS S&F TV sockets complete with all accessories complete all as specified and as directed.
13S&F RJ 11 Gang with shutter (Telephone Jack) complete with all accessories complete all as specified and as directed.
14Supply & fixPVC metal braided connection pipes for hot water supply with brass adopters 15 mm dia and 450mm long complete all as specified and as directed.
15S & F LED batten suitable for indoor application 20 W, 4" length , wall mounted with aluminium housing, end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall/ ceiling and connecting up with twin core twisted flexible copper conductor cable of suitable sizecomplete all as specified and as directed
16Supply and fixing load line distribution board TPN vertical, 4 way double door type, fixed on wall semi flush with incoming MCCB 4 poles 125 Amps, 16 KA, busbars ,neutral link, blanking plates complete with all accessories all as specified and as directed by Engineer-in-Charge. Note: Outgoing MCBs shall be measured and paid separately
17Supply & fix LED lampB22 base 10 W, min lumen output 950 lumens at 6500 K CCT with batten lamp holderscomplete all as specified and as directed.
18Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete with twin core twisted flexible copper conductor cable of suitable sizecomplete all as specified and as directed
19M & L for inverter point wiring for one light, ceiling fan and 5 Amp socket for each roomwith 2.5 sqmm,PVC insulated, unsheathed, single core multistandard copper conductor cable( FRLS), 1100 volts grade including 2.5 Sqmm PVC insulated, unsheathed, copper conductor cable for earth continuity wire to be drawn through in and including PVC conduit medium grade ISI markedwith its accessories upto the main DBand 15 A switch socket combination with gang box flushed in wallfor inverter power supplycomplete all as specified and as directed.
20M&L for earthing complete with galvanised steel earth electrode 60 cm x 60 cm x 6 mm buried directly in ground vertically to depth not less than 2.25 m below normal ground level with top edge of the earth plate at a depth not less than1.5 m below ground level connected to and including GI earth lead wire 4 mm dia by meansof nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GIprotection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
21M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to and including earth lead of galvanized strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I with connected to earth test point & to main switch board with & including adequate quantity of charcoal and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe fpr suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mess including necessary earth work and PCC (1:3:6) type C1 for earth pit and 40mm thick precastRCC cover in cement concrete 1:2:4 type B1, with 3 Nos 8mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified and directed NOTE: Item includes the cost of earth lead and GI protection pipe up to 7.5 m.GI strip and protection pipe beyond 7.5 m shall be measured and paid for separately.
22M & L for drawing 12 pair /multi core coated copper telephone cable including PVC conduit of size 20mm complete all as specified and as directed.
23M &L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etcas required 4mm complete all as specified and directed.
24Supply and fix hot water pipe duly insulated with glass wool and aluminium cladding complete in all respect of size 20mm bore all as specified at site complete all as specified and directed.
25S & F 30 W LED security light fitting made out of pressure die cast aluminium powder coated housing high impact resistant 4mm thick toughened glass cover and matrix of power LEDsinbuilt electronic driver up to 4KV surge protection fitted with adjustable pole adapter to enable on site tilt angle setting depending on road geometry CCT5500-6500 CRI greater than 70 , input power 30Woutput operating voltage 140-280V with connection by three core PVC insulatedmultistranded copper conductor sheathed cable of size 1.0 sq mmfixed with & including bracket made of GI pipe 40mm bore light grade, 1.6 mtr long bent to shape required with 2 no MS clamps of suitable size and length, nuts & boltscomplete all as specified and as directed.
26M&L for sub main wiring with Two runs of 4.0 Sqmmsize main cable and one run of 4.0 Sqmm size earth continuty conductor of single core PVC insulated but unsheathed FRLS cable multi standed copper conductors, 1100 volts grade, IS-694 marked all drawn through and including suitable size rigid PVC conduit pipe medium grade ISI marked & fittings/ accessories all fixed to the surface of wall/ceiling complete all as specified and as directed
27M&L for sub main wiring with Two runs of 6.0 Sqmmsize main cable and one run of 6.0 Sqmm size earth continuty conductor of single core PVC insulated but unsheathed FRLS cable multi standed copper conductors, 1100 volts grade, IS-694 marked all drawn through and including suitable size rigid PVC conduit pipe medium grade ISI marked & fittings/ accessories all fixed to the surface of wall/ceiling complete all as specified and as directed
28M&L for sub main wiring with four runs of 10.0 Sqmmsize main cable and one run of 10.0 Sqmm size earth continuty conductor of single core PVC insulated but unsheathed FRLS cable multi standed copper conductors, 1100 volts grade, IS-694 marked all drawn through and including suitable size rigid PVC conduit pipe medium grade ISI marked & fittings/ accessories all fixed to the surface of wall/ceiling complete all as specified and as directed
29Note for item No 26.00 to 28.00: The above mentioned specefied runs of single core cables and specefied runs of earth continuity conductors and the relevant conduit with accessories shall be measured as one runs length.The small extra lengths required for loops etc for connection in DBs shall deemed to be included in quoted rate and only the cable covered in conduit shall be measured.
30ROAD & FOOT PATH M&L for 150 mm thick WMM (Wet Mix Macadam) (compacted thickness) laid in two layers of 75mm thick each conforming to grading given in table 400-13 & physical requirement given in table 400-12 spread by mechanical means & rolled by using 8-10 ton vibrator power roller over compacted sub grade surface of soling as specified in clause 406 3.5 of MORTH specification and necessary lateral support and formwork if required complete all as specified and directed.
31M&L for cement concrete bed to drain pipes in PCC 1:3:6, type C2 (using 40mm graded stone aggregate), for 450mm bore drain pipe including packing under and haunching against the sides of pipes with concrete after they are laid and tested complete all as specified and directed.
32EXTERNAL WATER SUPPLY Supply, installation, connecting and testing sluice valve, non rasing type spindle, cast iron body & wedge with Bronze wedge ringon both side, gland packing, class - PN 1.6 with flanged ends drilled suitable for bore of pipe 100 mm ISI marked (IS:14846:2000) having S.S. spindle with iron wheel at top, complete with nuts bolts washers rubber gasket etc all as specified and directed.
33M&L for cutting of existing CI/DI/GI pipe and insterting and including Tee of size 100mm x100mm x100mmfor making suitable connection complete all as specified and directed. Note:- Quoted unit rate of this item includes the cost of excavation and earth work and refilling required for completion of job.
34EXTERNAL ELECTRIFICATIONS Supplying, installing, testing and commissioning of AC 3 phase, 50 HZ, 160 KVA capacity transformer, step down, outdoor type, 11000/433 volts (at no load) with system voltage 12KV all as per IS 1180 (Part 1):2014, copper wound, oil immersed, naturally cooled with external cooling tubes, ONAN Cooling, core type, delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector group-4) with neutral brought on secondary (LV) side & having tappings in equal steps of 2.5 % from (+) 5% to (-) 10% on primary side by means of hand operated off load tap changing gear, so as to change/correct L.T voltage on secondary side including provision of all necessary / standard fittings all as per IS:2026 & IEC 76 Latest ammendments and confirming to BEE 5 Star Rating (Level 3 transfomer) as per IS 1180 (Part 1):2014
35(a) The core shall be stack/wound type of high grade Cold Rolled Grain Oriented or Amorphous Core annealed steel lamination having low loss and good grain properties, coated with hot oil proof Inter layer insulation of Nomex /Epoxy dotted Kraft Paper, bolted together and to the frames firmly to prevent vibration or noise. The core shall be stress relieved by annealing under inert atmosphere if required.The complete design of core must ensure permanency of the core loss with continuous working of the transformers. LV winding shall be such that neutral formation will be at top. Current density for HV and LV winding should not be more than 2.8 Ampere per sq mm. (b)The maximum allowable losses at 75 °C for 11/0.433 kV at 50% of rated load and total losses at 100% of rated load shall not exceed the maximum total loss 416 watts and 1281 watts respectively without any positive tolerance all as per specified in IS 1180 (Part-1):2014 for energy efficient rating 5star. (c) Overload capacity of transformers shall be suitable for loading as per IS 6600 (d) The percentage impedance of transformers at 75 °C for 160 kVA shall be as per Table 6 of IS 1180 (Part-1) : 2014
36(e) Transformer tank construction shall conform in all respect to clause 15 of IS 1180(Part-1):2014. The internal clearance of tank shall be such, that it shall facilitate easy lifting of core with coils from the tank without dismantling LV bushings. All joints of tank and fittings shall be oil tight and no bulging should occur during service. Inside of tank shall be painted with varnish/hot oil resistant paint.The top cover of the tank shall be slightly sloping to drain rain water. The tank plate and the lifting lugs shall be of such strength that the complete transformer filled with oil may be lifted by means of lifting shackle.Manufacturer should carry out all welding operations as per the relevant ASME standards. The transformer tank shall be of robust construction and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for the bottom and top and not less than 4 mm for the sides for distribution transformers with Tolerances as per IS-1852.The space above oil level in the tank shall be filled with dry air or nitrogen conforming to commercial grade of IS 1747. The tank shall further be capable of withstanding a pressure of 0.8kg/sq.cm and a vacuum of 0.7 kg/sq.cm (g) without any deformation. (f) Audible sound levels for 160KVA, 50Hz liquid immersed distribution transformers shall be 56 decibels (NEMA Standards) (g) One cable box on primary H.V side having cable glands suitable for 95 Sqmm 3 core XLPE 11 KV H.T cable consisting of 3 Nos porcelain H.T bushings with brass/ gun metal bushing rods confirming to IS 2099 and IS 3347 for outdoor bushing complete with nuts and washers.HT Cable box should prevent the ingress of moisture into the box due to rain water directly falling on the box. The cable box on HT side shall be of the split type with faces plain and machined and fitted with Neo-k-Tex or similar quality gasket and complete with brass wiping gland to be mounted on separate split type gland plate with nut-bolt arrangement and MS earthing clamp. The bushings of the cable box shall be fitted with nuts and stem to take the cable cores without bending them. The stem shall be of copper with copper nuts. The cross section of the connecting rods shall be stated and shall be adequate for carrying the rated currents. On the HV side the terminal rod shall have a diameter TS for 3 Phase DT 11 of not less than 12 mm. The material of connecting rod shall be copper. HT Cable support clamp should be provided to avoid tension due to cable weight.
37(h) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushings complying to IS 7421 with GMbushing rods complete with GM nuts, and washers with cable gland suitable for reception of outgoing L.T. PVC sheathed armoured cables of size 2 x 300 sqmm 3.5 core . having non-magnetic material gland plate with appropriate sized single compression brass glands on LV side to terminate 1.1 kV/single core XLPE armoured cable. (j) The bushing rods and nuts shall be made of brass material 12 mm diameter for both HT and LT bushings. The bushings shall be fixed to the transformers on side with straight pockets and in the same plane or the top cover . The tests as per latest IS 2099 and IS 7421 shall be conducted on the transformer bushings. (k) OIL CONSERVATOR:The provision of conservator is mandatory with oil gauge, air release plug andbreathing device with a drain plug and a filling hole 32 mm (1¼”) normal size thread with cover. The dehydrating agent shall be silica gel. The moisture absorption shall be indicated by a change in the colour of the silica gel crystals which should be easily visible from a distance. Volume of breather shall be suitable for1Kg of silica gel conforming to IS 3401. The total volume of conservator shall be such as to contain 10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator. (l) The radiators can be tube type or fin type or pressed steel type to achieve the desired cooling to limit the specified temperature rise. (m) Transformer to be painted with poly urethene/powder caoted (color light gray & DA gray) paints over anti corrosive primer & shall be free from runs, sags, wrinkles, patchiness, brush marks or other defects.All primers shall be well marked into the surface, particularly in areas where painting is evident and the first priming coat shall be applied as soon as possible after cleaning. The paint shall be applied by airless spray.
38(n) One No 100 mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, maxtemp indicator and resetting device (o) Rating plate with terninal markings. (p)Two earthing terminals on tank/tank cover to facilitate fixing of 32 x 6 m GI earth strip. (q) Lifting lugs. (r) Four plane solid cast steel detachable rollers. (s) First fill of fresh transformer oil conforming to IS-335, BS148, D-1473, D-1533-1934IEC Pub296 and tested upto 40 KV dielectric strength. Use of recycled oil is not acceptable. The specific resistance of the oil shall not be less than 2.5X10¹² ohm-cm at 27°C when tested as per IS 6103. (t) Extra bushing for neutral outside the L.T cable box for providing independent earthing for neutral. (u)Provision of 2 Nos danger boards 250 x 200 mm size made out of 1.6 mm thick M.S. plate, vitreous enameled white, with letters. figures of voltage and conventional skull and bones insignal red colour , one at H.T side and other on L.T side. (v)Any other fittings / accessories so as to conform the whole transformer toIS 1180 (Part 1): 2014
39(w) The DistributionTransformers to be supplied against this Specification shall be suitable for satisfactory continuous operation under the following climatic conditions as per IS 2026(Part-I): (i) Location:Ahmedabad (ii)Maximum ambient air temperature (°C):50 °C (iii) Minimum ambient air temperature (°C) :5°C (iv) Maximum average daily ambient air temperature(°C):42 °C (v)Maximum yearly weighted average ambient temperature (°C) : 32 °C The temperature rise over ambient shall not exceed the limits given below: (i) Top oil temperature rise measured by thermometer : 35 °C (ii) Winding temperature rise measured by resistance method : 40 °C
40Construction of brick masonry platform in cement mortar 1:4 of size 2400 x 1800 x1200 mm for outdoor type transformer having sides finished with brick work with plaster complete with PCC foundation of 1:5:10 & PCC platform at top with 30 cm thickof PCC 1:5:10 and 10 cm thick of PCC 1:2:4 and having brick steps at one side, complete with XPM jali duly welded with angle iron of size 50 mm x 50 mm x 6 mm all around upto 0.6 metre, including excavation and earth work in any type soil , returning filling in and removal of surplus soil upto 50 metre complete all as shown on drawing or as directed.
41M&L for complete set ofLED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing, heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection fixed to pole complete comprising of the followings:-
42(i) bracket made out of light grade, Galvanised steel tube, 40mm bore, 1.5 Mtr length, bent to 120 degree for fixing street light fitting at the top, fixed to pole with necessary clamps made out of FI 40mm x 4mm with nuts & bolts (ii) sintex juction box of size 230x170x105mm compete with oneSP MCB of 6 Amps (iii) PVC insulated, sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade,multistranded, passing throuth pipe, fixed on pole/wall from juntion box to street light fitting
43Supply, installation, commissoning and testing,feeder pillar board, Kiosktype, LT (415 Volts, 50 Hz , 3-phase, 4 wire supply), plinth mounted, factory made, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 50mm x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.20 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:-
44Incoming supply :- (i) Aluminium bus bar chamber 200 amps rating of 04 strip - 01 No (ii) MCCB, thermal and megnatic setting, 4 pole, AC, 415 volts, 125 Amp rating, 25 KA rupturing capacity - 01 No (iii) Digital type multifunctional metershowing PF, V, I, Hz etc. - 01 No (iv) Indicatiing lamp Neon type for R-Y-B - 3 Nos. (b) Outgoing supply:- (i) MCCB, thermal and meganitic setting, 3 pole, AC, 415 Volts, 63 Amp rating, 16 KA rupturing capacity - 04 No (ii) Cable connection through straight plugs 63A, 415 Volt - 04 Nos Cat No. 058705 Tempra Pro IP-67 and Panel mounting Socket 63 Amp, 415 Volt - 04 Nos Cat No. 058725 Tempra Pro IP-67.
45Supply Installtion Testing andCommissioning (SITC) of Indoor type factory made Automatic Power Factor Correction (APFC) of capacity 80 KVAR fabricated out of 2mm thick MS sheet, openable front fitted with low watt loss capacitors to improving power factor, suitable for 415 votls, 50 Hz, 3 phase, 4 wire with and including the following :- (a) Digital multi functional meter showing current, voltage, power factor, frequency with suitable CT"s ratio - 01 No (b) Indicators RYB - 1 Set (c) Capacitor step on indication lamps - 04 Nos (d) Auto-manual selector switch - 01 No (e) On/Off push buttons for manual mode-01set
46(f) Micro processor based APFC relay 4 steps having all the required features-01 No (g) MCB TP 16 Amp - 04 Nos (h) Aluminium busbars of suitable capacity TPN-01 Set (j) Internal wiring of panel board with copper cable. (k) MCCB 25KA/ 3 pole, 50 Hz, 160 Amp-01 No (l) 2.5 Sqmm 2 core LT armored cable for connection of main panel CT with APFC panel (m) LT power capacitor cylindrical capacitor 20 KVAR, 440 volts, 3 phase, 50 Hz-01 No (n) Capacitor duty contactor capacity 40 KVAR, 415 votls, 3 phase, 50 Hz-01 No (o) Capacitor duty contactor capacity 10 KVAR, 415 Votls, 3 Phase, 50 Hz-02 Nos
47Supply, installation, commissoning and testing, LT Panel board, cubical type,(415 Volts, 50 Hz , 3-phase, 4 wire supply), floor mounted, factory made and tested, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 6mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet with front & back opening type of adequate size for housing LT switchgear ahd measuring instrumentsdulypowder coated after seven tank process on both sides incl internal wiring in the panel with suitable size of PVC multistranded copper cable 1100 volts grade IS-694 and complete comprising of the followings:-
48Bus bar 400 Amps. 4 Pole aluminium (50 KV) (a) Incoming supply:-(i) MCCB, Thermal magnetic seting, 4 pole, AC, 415 volts, 320 Amp rating, 35/36 breaking capacity, 50 Hz - 01 No (ii) LED Indicatiing lights for R-Y-B - 01 Set (iii)Panel mounted multifunction meter suitable to operate on and incl CT in accuracy class 1.0, suitable 3 Phase CT network CT primary programmable, three line baklit display of phase to phase rating phase to neutral voltage current active power KW, KVAR, KVA, PF Frequancy. (b)Outgoing supply:- (i) MCCB, thermal and meganitic setting, 4 pole, AC, 415 Volts, 100 Amp rating, 25 KA breaking capacity - 05 No (C)Time switch auto dusk dawn (Nature) 3 Phase including connection for operation of 20 x 60 watt lights.
49Supplying, installing, testing and commissioning, of factory made LT Meter box, wall mounted board made out of CRCA Sheet of 2mm thick indoor type totally enclosed weather, dust and vermin proof with front opening hinged door and locking arrangement mounted on MS flat iron (40x6mm and 6" long) 04 No clamp welded to 40mm x 40mm x 6mm size angle iron frame alround panel duly grouted on wall, 415 volts, 3 phase, 4 wire AC 50 Hz having aluminium bus bar for phase and the neutral insulated with PVC sleeves, space for fixing single phase KWH electric meter of suitable capacity 04 Nos, copper lugs, spacers, mounting channels, rubber gasket, locking knobs, hylam sheet pieces, nuts and bolts, washers etc. and suitable size single core copper wire connections suitable compartments and epoxy powder spray paint with primer complete all as specified including the following accessories:-
50Incoming - (a) MCCB 415 Volts, 4 Pole, 25 KA breaking capacity of 125 Amps - 01 No (b) R-Y-B Phase, LED indicating lamp - 03 Nos (c) 20A/4Amps HRC control fuse with fuse link - 03 Nos (d) 150 Amp main Aluminium bus bar. multifunction meter with suitable CT. Outgoing - (a) MCB, SPN, 63 Amp, 10 KA - 04 Nos (b) Space for mounting single phase energy meter-04 Nos (c) Copper cable 10 Sqmm wire and open terminals for all feeders.Note : Quarter No to be mentioned in respective meter on aryclic plate & cost of aryclic plate to be included in quoted rate.
51M&L for sand cushioning to cables with tibba sand and punning to provide required cover to UG cables complete as per SSR Part-I all as specified and directed. Note: Punned down thickness shall only be measured and paid.
52Supply and installation of Ring main unit one incoming two outgoing SF6 filled loadbreak switch each of 11 KV, 3Phase, 50 cycles, totally enclosed metal clad SF6 switchgear having rupturing capacity upto 350 MVA overload and earth faulth protection, Ammeter, voltmeter and of rating up to 630 Amp complete all as per specified and directed.
53S & F cable route indicator for HT, 6mm thick CI plate of size 100mm dia welded to MS angle iron 50mm x 50mm x 6mm embedded in PCC 1:3:6 type C-1 block size 150mm x 150mm x 160mm complete all as specified and directed.
54M&L for horizontal boring by using the trenchless technology under the road at least 60 Cm below road top, in any type of soil for insertion of GI pipeof 80mm bore. complete all as specified and directed.
55ARBORICULTURE Digging of pit n. Exc 0.25 cum in any type of soil including removal and filling back tp pit with suitable growing media like red earth by treating with farm yead manure in the ratio (3:1) fertilizers and pesticides (i.e. Bevation and neem cake BHC 10% linson dust. Thimment or phorate, manure super and vermicompost) and making up the trench area to proper level including supply and planting tree plants of species of height not less than 3 feet as Neem (Azadiracha indica) complete all as specified and directed.
56Ditto all as per item No 44.00 hereinbefore but Gulmohar (Delonix regia)
57Ditto all as per item No 44.000 hereinbefore but Peepal tree (Ficus religiosa)
58Ditto all as per item No 44.000 hereinbefore but Banyan (Ficus benghalensis)
59Ditto all as per item No 44.000 hereinbefore but Pink Cassia (Cassia javanica)
60Ditto all as per item No 44.000 hereinbefore but Christmas tree (Araucaria heterophylla),
61Ditto all as per item No 44.000 hereinbefore but Golden Cane Palm (Dypsis lutescens),
62Ditto all as per item No 44.000 hereinbefore but Royal Palm (Roystonea regia)
63Ditto all as per item No 44.000 hereinbefore but Foxtail Palm (Wodyetia bifurcata)
64Ditto all as per item No 44.000 hereinbefore but False Ashoka (Monoon longifolium)
65Maintenance of planted trees and lawn area grass for two year after certified date of completion issued by GE, by employing one experienced mali per day. The maintenance shall includes the following. (a) Periodical de-weeding of unwanted vegetation growth around the plants/lawn area(b) Watering all the trees/plants/grass and soil with required for proper growth. (c) Periodical prunning the shrubs.(d) periodical lawn mowing. (e) Treating the trees/plants grass and soil with required quantity of approved manure, pesticides and fertillizer including necessary toping of red earth. (f) Replacement of dried/dead plants/grass/trees.(g) Hose pipe to be arranged by the contractor. (h) water shall be supplied by Deptt free of cost only for watering to plants.