Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-11-2023 | Date Extension | Date | 03-11-2023 |
| Sl. No. | Item Description |
| 1 | SOFTSCAPE WORKS |
| 2 | Trees & Palms Supplying and planting of approved trees species of a height 3.0m to 3.5m, at the specified locationas shown in the drawing. Rate shall include Cost of plants, soil work inclusive of redsoil sand and manure mix staking and planting of trees sapling, replacement of dead trees and for providing a pit size 0.75 x 0.75 x 0.75 m and maintenance till the completion of project work. (rates inclusiveof maintenance for 1 year after planting) Terminalia mantaly |
| 3 | Trees & Palms Supplying and planting of approved trees species of a height 3.0m to 3.5m, at the specified locationas shown in the drawing. Rate shall include Cost of plants, soil work inclusive of redsoil sand and manure mix staking and planting of trees sapling, replacement of dead trees and for providing a pit size 0.75 x 0.75 x 0.75 m and maintenance till the completion of project work. (rates inclusiveof maintenance for 1 year after planting) Terminalia mantalyVarigated |
| 4 | Trees & Palms Supplying and planting of approved trees species of a height 3.0m to 3.5m, at the specified locationas shown in the drawing. Rate shall include Cost of plants, soil work inclusive of redsoil sand and manure mix staking and planting of trees sapling, replacement of dead trees and for providing a pit size 0.75 x 0.75 x 0.75 m and maintenance till the completion of project work. (rates inclusiveof maintenance for 1 year after planting) Foxtail palm |
| 5 | Trees & Palms Supplying and planting of approved trees species of a height 3.0m to 3.5m, at the specified locationas shown in the drawing. Rate shall include Cost of plants, soil work inclusive of redsoil sand and manure mix staking and planting of trees sapling, replacement of dead trees and for providing a pit size 0.75 x 0.75 x 0.75 m and maintenance till the completion of project work. (rates inclusiveof maintenance for 1 year after planting) Tabebuia rosea |
| 6 | Trees & Palms Supplying and planting of approved trees species of a height 3.0m to 3.5m, at the specified locationas shown in the drawing. Rate shall include Cost of plants, soil work inclusive of redsoil sand and manure mix staking and planting of trees sapling, replacement of dead trees and for providing a pit size 0.75 x 0.75 x 0.75 m and maintenance till the completion of project work. (rates inclusiveof maintenance for 1 year after planting) Brassia Actinophylla |
| 7 | Trees & Palms Supplying and planting of approved trees species of a height 3.0m to 3.5m, at the specified locationas shown in the drawing. Rate shall include Cost of plants, soil work inclusive of redsoil sand and manure mix staking and planting of trees sapling, replacement of dead trees and for providing a pit size 0.75 x 0.75 x 0.75 m and maintenance till the completion of project work. (rates inclusiveof maintenance for 1 year after planting) Cerbera Odollam Rubra height 2m to 2.5m |
| 8 | Trees & Palms Supplying and planting of approved trees species of a height 3.0m to 3.5m, at the specified locationas shown in the drawing. Rate shall include Cost of plants, soil work inclusive of redsoil sand and manure mix staking and planting of trees sapling, replacement of dead trees and for providing a pit size 0.75 x 0.75 x 0.75 m and maintenance till the completion of project work. (rates inclusiveof maintenance for 1 year after planting) Spathodea campanulata verigated |
| 9 | Trees & Palms Supplying and planting of approved trees species of a height 3.0m to 3.5m, at the specified locationas shown in the drawing. Rate shall include Cost of plants, soil work inclusive of redsoil sand and manure mix staking and planting of trees sapling, replacement of dead trees and for providing a pit size 0.75 x 0.75 x 0.75 m and maintenance till the completion of project work. (rates inclusiveof maintenance for 1 year after planting) Microphylla cone shape height 0.2m to 2.5m |
| 10 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Plumbago capansis -height 0.3m to 0.45m |
| 11 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Ficus Gold -height 0.3m to 0.45m |
| 12 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Ixora coccinea dwarf - Red -height 0.3m to 0.45m |
| 13 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Ixora coccinea dwarf - Pink -height 0.3m to 0.45m |
| 14 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Ixora coccinea dwarf - White -height 0.3m to 0.45m |
| 15 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Allamanda neriifolia -height 0.3m to 0.45m |
| 16 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Cestrum nocturnum -height 0.3m to 0.45m |
| 17 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Spider lily varigated -height 0.3m to 0.45m |
| 18 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Acalypha wilkesiana -height 0.3m to 0.45m |
| 19 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Pennisetum Setaceum - height 0.3m to 0.45m |
| 20 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Cyperus Alternifolius -height 0.3m to 0.45m |
| 21 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Tabernaemontana variegated -height 0.3m to 0.45m |
| 22 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Russelia equisetiformi -height 0.3m to 0.45m |
| 23 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Duranta gold -height 0.3m to 0.45m |
| 24 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Legastromia- height 0.3m to 0.45m |
| 25 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Malfizia Plant - height 0.3m to 0.45m |
| 26 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Eugenia - height 0.3m to 0.45m |
| 27 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) heliconia - height 0.3m to 0.45m |
| 28 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Areca palm- height 0.75m to 1.0m |
| 29 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Bamboo gold - height 3m to 3.5m |
| 30 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Bamboo Verigated -height 3m to 3.5m |
| 31 | Shrubs & Hedge PlantsSupplying and planting of approved Shrubs & Hedge Plantsspecies of a height 0.3m to 0.45m at required spacing as shown in drawing.Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting) Rhapis excelsa - height 0.75m to 1.0m |
| 32 | Ground CoversSupplying and planting of approved ground cover at required spacing as shown in drawing. Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting)Wedilia |
| 33 | Ground CoversSupplying and planting of approved ground cover at required spacing as shown in drawing. Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting)Zephyrlily - White, Pink, Yellow |
| 34 | Ground CoversSupplying and planting of approved ground cover at required spacing as shown in drawing. Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting)Alternanthera red |
| 35 | Ground CoversSupplying and planting of approved ground cover at required spacing as shown in drawing. Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting)Ophiopogon -veriegata |
| 36 | Ground CoversSupplying and planting of approved ground cover at required spacing as shown in drawing. Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting)Pentanus |
| 37 | Ground CoversSupplying and planting of approved ground cover at required spacing as shown in drawing. Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting)Golden ferns |
| 38 | Ground CoversSupplying and planting of approved ground cover at required spacing as shown in drawing. Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting)Tradescantia |
| 39 | Ground CoversSupplying and planting of approved ground cover at required spacing as shown in drawing. Rate shall include cost of plants soil work, manure and fertilizers used in top dressing, chemical and mechanical pest control, staking and maintaining the planting till it is handed over from the date of planting and replacement of dead plants. (rates inclusiveof maintenance for 1 year after planting)Hemigraphis Colorata |
| 40 | Mexican grassSupplying and laying the Mexican grass over the leveled and prepared surface. The rate to include cost of grass, inputs manure and fertilizers used periodically for top dressing chemical and mechanical pest control and all post planting maintenance procedure (deweeding lawn cutting and moving, edge trimming, leveling the grass surface with roller) etc complete till the completion of project, replacement of dead Grass. (rates inclusiveof maintenance for 1 year after planting) |
| 41 | Garden SoilSupplying and spreading of approved quality gardensoil with a suitable mix ratio. The soil mix to be well mixed and spread over prepared area free from all debris and construction waste to the required slope as per site engineers instrutions.Organic mixture consists of Neem cake 5Kg, NPK1/2Kg, Vermicompost 10Kg and all mixed with soil in correct proportion for 500sft (rates inclusive of maintenance for 1 year after planting) |
| 42 | IRRIGATIONPIPE WORKSupplying of approved make PVC pipes and fittings confirming to I.S specifications with all lead and lifts including earth work excavation fo all kind of soil to the depth of 450mm etc., MAKE- Ashirvad /Prince/ FinolexUPVC pipe SHE.40 - 2\" |
| 43 | IRRIGATIONPIPE WORKSupplying of approved make PVC pipes and fittings confirming to I.S specifications with all lead and lifts including earth work excavation fo all kind of soil to the depth of 450mm etc., MAKE- Ashirvad /Prince/ FinolexUPVC pipe SHE.40 - 1¼\" |
| 44 | IRRIGATIONPIPE WORKSupplying of approved make PVC pipes and fittings confirming to I.S specifications with all lead and lifts including earth work excavation fo all kind of soil to the depth of 450mm etc., MAKE- Ashirvad /Prince/ FinolexUPVC pipe SHE.40 - 1\" |
| 45 | IRRIGATIONPIPE WORKSupplying of approved make PVC pipes and fittings confirming to I.S specifications with all lead and lifts including earth work excavation fo all kind of soil to the depth of 450mm etc., MAKE- Ashirvad /Prince/ FinolexUPVC pipe SHE.40 -½\" |
| 46 | IRRIGATIONPIPE WORKSupplying of approved make PVC pipes and fittings confirming to I.S specifications with all lead and lifts including earth work excavation fo all kind of soil to the depth of 450mm etc., MAKE- Ashirvad /Prince/ FinolexPVC Fittings&Accesseries e.g.Couplings,tees&elbow. |
| 47 | 16mm inline LLDPE Pipe Line with necessary FITTINGS etc,. MAKE- A.G.S/ALPHA |
| 48 | 16mm lateral LLDPE Pipeline with necessary FITTINGS etc MAKE- A.G.S/ALPHA |
| 49 | MISTS- MAKE- A.G.S/ALPHA |
| 50 | DRIPPERS all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters,etc. jointing as per manufacturers\" instruction,MAKE- A.G.S/ALPHA |
| 51 | SPRINKLERS & ACCESSORIESProvidingof Pop upsprinkler full/part circle having radius of throw 3.0m - 5.5m & flow of 0.38 - 0.5 ltr./sec.at an operative pressure of 2.0 - 2.5 kg/cm.sq. , The sprinkler istype having 1/2\" bottom inlet, overall height and servicable through the top of the increased distance of throw, self flushing inner trip, adjustable arm spring for low pressure operation, hooded bearing, distance controller diffuser pin & inlet filter screen .The sprinkler shall have multi-function, pressure-activated wiper seal for low pressure opreation and for cleaning debris from the riser as it retract into the case.Thebody of sprinkler is of non - corrodible, heavy duty, ABS plastic. make: Rain Bird |
| 52 | VALVES & ACCESSORIESProvidingP.P Ball Valve,security pivot to maintain lever in space ,double water tight joint ,direct injection stem non mechanical ,with a base which permits maximum penetration into the valve. MAKE- Ashirvad /Prince/ Finolex P.P. Ball Valve63mm |
| 53 | VALVES & ACCESSORIESProvidingP.P Ball Valve,security pivot to maintain lever in space ,double water tight joint ,direct injection stem non mechanical ,with a base which permits maximum penetration into the valve. MAKE- Ashirvad /Prince/ Finolex 10\" Round Valve Box,Make: Rain Bird |
| 54 | FILTERATION UNIT Providingof Screen Filter (200 mesh) with Twin filtering elements of 30m3 /hr having an inlet connections of 3\", to create a helical effect in the incoming water ,spinning particulate in suspension away from the filtering element and so minimizing cleanings frequency ,3/4\" outlet for flushing at bottom of filter & maximum working presure of 6 Bars. Make: Rain Bird |
| 55 | FILTERATION UNIT Providingof Fertilizer unit with 60ltr capacity Make: Rain Bird |
| 56 | PUMPING UNITSupplying installation testing and commissioning of Mona Black Pump Set squirrel cage induction motor water lubricated with oil seals with sleeves and thrust bearing having all rotating parts dynamically balanced for silent operation Suitable for three phase 50 HZ AC supply Motor Body : CI Pump Body : CIMake : Kirloskar/Texmo or equivalent Capacity : 7.5 - HP Three Phase Discharge 5 LPSHead 40 Mtr Suction & Delivery 100x100mm |
| 57 | NON RETURN VALVE |
| 58 | Trench Work |
| 59 | HARDSCAPE WORKSProviding TMT Bars Fe-500D grade confirming to IS 1786,transporting to site, storing, de-coiling (if required), straightening, cutting, bending, spirally hooping, bundling and placing, in position reinforcement bars, to correct shape and size as per detailed drawings, specifications, preparing and getting approved bar-bending schedules for all reinforced concrete work such as Pile, walls, columns / stub columns, beams, slabs, staircase etc.; withcorrect size of heavy duty PVC / concrete (of same grade of concrete) cover blocks and galvanized binding wire of 18 gauge; required dewatering, provide required labour and machines / equipment / tools / tackles for handling, shifting, bending, binding,etc. The measurement shall be as per IS 1200. The item shall include cost of concrete cover blocks, binding wire, all complete to the satisfaction of the PMC/Employer at all depths, height, lift & leads. |
| 60 | HARDSCAPE WORKSExcavation in all kinds of soil, wet or dry (such as clay, Silty Clay, Sandy clay with Medium/High Plasticity and Soft disintegrated rock etc.,) in loose and slushy condition, including demolition of any existing concrete portion with suitable mechanical excavators like Poclain, JCB etc., and manually wherever required, to the required level for foundations, trenches, rafts, plinths, area levelling, etc., to required depth from existing ground level including disposing off surplus excavated material within the site and levelling as per directed by the Engineer-in charge. bailing/pumping out water to keep the site dry at all times until completion of backfilling; making temporary stepping / sloping,sectioning, trimming, dressing of sides, levelling or grading, cleaning, removing and excavating loose pockets etc., all complete to all depths, to the satisfaction of the Engineer-in-charge.All pits shall be properly barricaded at any point of time.Upto 1.5m only. |
| 61 | HARDSCAPE WORKSSupplying, Filling with selected, suitable excavated earth (excluding rock) in layers each not exceeding 150mm in depth, breaking clods, watering, compacting each layer with vibratory compactor and at inaccessible places with wooden/steel rammers to achieve 95% proctor density at optimum moisture content; dressing up embankments; if required, bailing/pumping out of water to keep site dry while back filling; costs includes transportation of all materials, labour, machinery etc. complete as perdirection and entire satisfaction to the Enigineer-in-charge |
| 62 | HARDSCAPE WORKSProviding, machine mixing and laying Plain cement concrete (PCC) M10 grade of required thickness for foundation, rafts, plinth beams, levelling course and all locations, etc. (minimum cementitious content shallbe as specified in the IS Code and as approved); including compacting, curing, required shuttering and its removal, dewatering where required and vibrating, cleaning, preparing surfaces, junctions, etc.; complete at all depths and leads as per the drawing and to entire satisfaction of the Engineer-in-charge (minimum Cement content 220 kg / cum) |
| 63 | HARDSCAPE WORKSProviding, transporting, pumping and laying batched design mixed, controlled concrete ofM30 grade (as specified in the Structural drawings) conforming to (IS 456) with minimum cement content and maximum water cement ratio as per IS or as specified by Structural Consultant including using approved quality admixtures and placed either with pump/manual/lift for following grades of concrete including compacting, vibrating, curing and protecting against excess etc. complete at all lead, lift & heights as per the drawing and to entire satisfaction of the Engineer-in-charge. (minimum Cement content 350 kg / cum) |
| 64 | HARDSCAPE WORKSFooting Works: Supplying and erecting steel / 12mm Plastic coated, marine resistant waterproof ply centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. Providing,fabricating, erecting form work and deshuttering at all levels and places wherever needed/specified as per drawing including striking with 12mm Plastic coated, marine resistant waterproof ply with adjustable steel props of acceptable Staging system and with sufficient bracing as approved by consultant. Cost to include designing of proper form work and staging system to suit the requirements, Submission of design calculations and shop drawings for approval, sealing the joints with heavy duty brown self adhesive tape, aligning to line and levels including M.S. Ties, PVC Spacer, Providing openings / cutouts / pockets, applying deshuttering chemical, Deshuttering as approved by the consultant etc., complete at all levels, double floor heights and profiles. |
| 65 | HARDSCAPE WORKSBeam Works: Supplying and erecting steel / 12mm Plastic coated, marine resistant waterproof ply centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. Providing, fabricating, erecting form work and deshuttering at all levels and places wherever needed/specified as per drawing including striking with 12mm Plastic coated, marine resistant waterproof ply with adjustable steel props of acceptable Staging system and with sufficient bracing as approved by consultant. Cost to include designing of proper form work and staging system to suit the requirements, Submission of design calculations and shop drawings for approval, sealing the joints with heavy duty brown self adhesive tape, aligning to line and levels including M.S. Ties, PVC Spacer, Providing openings / cutouts / pockets, applying deshuttering chemical, Deshuttering as approved by the consultant etc., complete at all levels, double floor heights and profiles. |
| 66 | HARDSCAPE WORKSColumn Works: Supplying and erecting steel / 12mm Plastic coated, marine resistant waterproof ply centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. Providing, fabricating, erecting form work and deshuttering at all levels and places wherever needed/specified as per drawing including striking with 12mm Plastic coated, marine resistant waterproof ply with adjustable steel props of acceptable Staging system and with sufficient bracing as approved by consultant. Cost to include designing of proper form work and staging system to suit the requirements, Submission of design calculations and shop drawings for approval, sealing the joints with heavy duty brown self adhesive tape, aligning to line and levels including M.S. Ties, PVC Spacer, Providing openings / cutouts / pockets, applying deshuttering chemical, Deshuttering as approved by the consultant etc., complete at all levels, double floor heights and profiles. |
| 67 | HARDSCAPE WORKSSuspended Floors Works: Supplying and erecting steel / 12mm Plastic coated, marine resistant waterproof ply centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation.Providing, fabricating, erecting form work and deshuttering at all levels and places wherever needed/specified as per drawing including striking with 12mm Plastic coated, marine resistant waterproof ply with adjustable steel props of acceptable Staging system and with sufficient bracing as approved by consultant. Cost to include designing of proper form work and staging system to suit the requirements, Submission of design calculations and shop drawings for approval, sealing the joints with heavy duty brown self adhesive tape, aligning to line and levels including M.S. Ties, PVC Spacer, Providing openings / cutouts / pockets, applying deshuttering chemical, Deshuttering as approved by the consultant etc., complete at all levels, double floor heights and profiles. |
| 68 | HARDSCAPE WORKSWalls Works: Supplying and erecting steel / 12mm Plastic coated, marine resistant waterproof ply centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. Providing, fabricating, erecting form work and deshuttering at all levels and places wherever needed/specified as per drawing including striking with 12mm Plastic coated, marine resistant waterproof ply with adjustable steel props of acceptable Staging system and with sufficient bracing as approved by consultant. Cost to include designing of proper form work and staging system to suit the requirements, Submission of design calculations and shop drawings for approval, sealing the joints with heavy duty brown self adhesive tape, aligning to line and levels including M.S. Ties, PVC Spacer, Providing openings / cutouts / pockets, applying deshuttering chemical, Deshuttering as approved by the consultant etc., complete at all levels, double floor heights and profiles. |
| 69 | HARDSCAPE WORKSBrick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 Coarse sand) |
| 70 | HARDSCAPE WORKSProviding and applying minimum 18mm thick double coat cement sand plaster; first coat to be 12mm thick cement sand mortar of mix ratio CM 1:5 (1 cement : 5 sand) i, second coat to be 6mm thick in cement sand mortar of mix ratio CM 1:6 (1 cement : 6 sand), finished sand face or as required to receive specified architectural external finish to correct line, plumb and level to external faces of walls, sofits/ceiling if any, including hacking concrete surfaces curing the same, racking out junctions of masonry and concrete, doing independent double legged scaffolding etc. - |
| 71 | HARDSCAPE WORKSDemolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 72 | HARDSCAPE WORKSDemolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge- |
| 73 | HARDSCAPE WORKSDemolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : |
| 74 | HARDSCAPE WORKSProviding and applying Acrylic Smooth Exterior Paint of approved make and colour conforming to IS in two coats (surface and finish acceptable to the EC/Client must be achieved by the contractor and any additional coats if required shall be at the cost of the contractor) of newly plastered wall surface with ready mixed paint of first class quality and approved colour over a priming coat with over textured finish including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., required scaffolding, leads and lifts at all levels. |
| 75 | HARDSCAPE WORKSProviding and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 76 | HARDSCAPE WORKSPreparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 77 | HARDSCAPE WORKSExtra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density) |
| 78 | HARDSCAPE WORKSProviding and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 79 | HARDSCAPE WORKSSteel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 80 | HARDSCAPE WORKSMixing cement sand morter 1:4 ratio added with water proofing compound CONPLAST X421IC Per bag of cement 125ml Cure the same for a minimum period of 3 days. Clean the loose mortar if any on the surface of wall. Acid wash and water wash the same. Allow the excess water to run off and make sure that the surface is damp. Mix part A and Part B BRUSH BOND of the polymer modified cement titious coating mechanically using a drilling fitted with mixing paddle. Apply the same to the prepared surface two coats, right angles to each other, one after the other dries up with the gap of minimum 4 hours and maximum 72 hours. |
| 81 | HARDSCAPE WORKSProviding and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge |
| 82 | HARDSCAPE WORKSProviding and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of all colour except black, cherry/ruby redof required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. |
| 83 | HARDSCAPE WORKSSupply and fixing Solid Granite Seating ( L 2m x W 0.6m x H 0.45m) |
| 84 | Fountain Supply and fixing ofVertical Jets 1\" Nozzle made up of brass with nickel plating including control valves mounted on Stainless steel 304 grade fabricated framework with stainless steel bolts and nuts including cost and conveyance of all materials etc., complete as per standard specifications. (rates inclusive of maintenance for 1 year after Handing Over) |
| 85 | Filter and AccessoriesImported filter including multiport valveFilter Capacity : Ø 900 mm / 32000 l/h Features : Fibre glass reinforced tank with UV resistant surface finish.Internal surface of the tank is finished with water resistant resin,Spherical tank with uniform wall thickness.All sand filters with oil pressure guage.(rates inclusive of maintenance for 1 year after Handing Over) |
| 86 | Filter and AccessoriesMain drain cover(rates inclusive of maintenance for 1 year after Handing Over) |
| 87 | Filter and AccessoriesEye ball inlet -(rates inclusive of maintenance for 1 year after Handing Over) |
| 88 | Filter and AccessoriesFloor inlet -(rates inclusive of maintenance for 1 year after Handing Over) |
| 89 | Filter and AccessoriesMaintenance Kit compressing of Vacuum Head, Vacuum Hose, Telescopic Handle, Leaf Rake, Leaf Scoop, Standard Wall Brush & Algae brush. (rates inclusive of maintenance for 1 year after Handing Over) |
| 90 | Filter and AccessoriesImported test Kit (rates inclusive of maintenance for 1 year after Handing Over) |
| 91 | Filter and AccessoriesPre filter(Saci), 3Hp Pump (2 No\"s) with Starter and MCP (rates inclusive of maintenance for 1 year after Handing Over) |
| 92 | Filter and AccessoriesVacuum point |
| 93 | Filter and AccessoriesFilter media 350 Kg (rates inclusive of maintenance for 1 year after Handing Over) |
| 94 | Filter and AccessoriesInstallation, testing and commissioning for filtration system |
| 95 | Supply & Fixing water proof high power LED RING Profile lights RGB/Multicolor made out of stainless steel 304gr. Manufactured by an ISO 9001 : 2015 Certified CompanySuitable to be fitted with emitter type power LED\"s with all in one optical lens of 85% efficiency step pampered glass 8 mm with protection class of IP-68.PVC gland, wire 4 core , Holder SS.304. Rating :- IP68/ ROHS/ CE |
| 96 | Supplying installation testing and commissioning of Open well submersible Pump Set with totally enclosed water filled squirrel cage induction motor water lubricated with oil seals with sleeves and thrust bearing having all rotating parts dynamically balanced for silent operation Suitable for three phase 50 HZ AC supply Motor Body : CI Pump Body : CIMake : Kirloskar/Texmo Capacity : 10 - HP Three Phase Discharge 45 LPSHead 10 Mtr Suction & Delivery 100x100mm |
| 97 | Supplying installation testing and commissioning of Open well submersible Pump Set with totally enclosed water filled squirrel cage induction motor water lubricated with oil seals with sleeves and thrust bearing having all rotating parts dynamically balanced for silent operation Suitable for three Phase 50 HZ AC supply Motor Body : CI Pump Body : CIMake : Kirloskar/TexmoCapacity : 7.5 - HP Three Phase Discharge 27 LPSHead 10 Mtr Suction & Delivery 65x165mm |
| 98 | Upvc Pipe & Fittings Supplying and Fixing of Upvc, Pipe (10 & 6 Kg/cm2 SH:80) of Make Ashirvad /Prince/ Finolex confirming to IS 4985:2000 including all UPVC fitting i/c jointing with good quality solvent of following sizes. all fixing to be done for the entire plumbing system to suit still running condition as approved by TNTPO / EC |
| 99 | Installation, testing and commissioning for water fountain (rates inclusive of maintenance for 1 year after Handing Over) |
| 100 | Providing and fixing of Glass Mosaic tiles on finished plain wall surface of size 20 x 20mm x 4mm in all colour design,fixing in customize design as per direction of engineer-in-charge. The glass mosaic tiles to be fixied on the wall surface with the help of approved adhesive applied at the rate of 2.5kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by TNTPO / EC (rates inclusive of maintenance for 1 year after Handing Over) |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail