Tender For Maint Servicing Of Summer Appliances And Connected Work Under Ge Mis Mhow, Indore-Madhya Pradesh

Military Engineer Services-MES has published Tender For Maint Servicing Of Summer Appliances And Connected Work Under Ge Mis Mhow. Submission Date for this Tender is 20-11-2023. Air Conditioner Tenders in Indore Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40337308
Corrigendum : Tender For Maint Servicing Of Summer Appliances And Connected Work Under Ge Mis Mhow
Open Tender
Indian
Madhya Pradesh
Indore
20-11-2023

Tender Details

Maint Servicing Of Summer Appliances And Connected Work Under Ge Mis Mhow

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31-Oct-2023 Other Corrigendum Other 13-11-2023
2 13-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work: MAINT /SERVICING OF SUMMER APPLIANCES AND CONNECTED WORK UNDER GE (MIS), MHOW
Sl. No. Item Description
1AIR CONDITIONERWINDOW /S PLITTYPE1.5/ 2 TON:
2M&L for removing the burnt/defective sealed compressor unit of any make from Windowtype air conditioner of capacity 1.5Ton by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fixing of new sealed compressor unit of Make: - Tecumseh Kirloskar, Model RNB 5522of rotary compressorby tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as specified and directed.
3All as per item No 1.01 abovebut Air conditioner of 2 ton capacity and sealed compressor unit Make:Tecumseh Kirloskar, Model RNB 5529 complete all as specified and directed.
4M&L for removing the burnt/defective sealed compressor unit of Split type air conditioner of capacity 1.5Ton by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fixing of new sealed compressor unit Make : Kirloskar, Model AE 5522E or CR 22K 6 M /AW 1500by tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as specified and directed.
5All as per item No 1.03 abovebut split type Air conditioner of 2 ton capacity and sealed compressor unit Make : Tecumseh, Model AW-2000 all as specified and directed.
6M&L for repairing, testing leakage in Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSI and repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system and supply & charging refrigerant gas F-22 (approx 1.90 Kg) complete.
7All as per item No 1.05abovebut Air conditioner of 2 ton capacityand supply and charging refrigrerant gas F-22 (approx 2.30 Kg) complete.
8S&F in replacement of electric blower motor of capacity 1/7 HP SP 230V, 50Hz, 930/875/825/775 RPM for window type Air conditioner including testing etc complete all as specified and directed Make : Gulmarg/GE Motor/Crompton Greaves
9S&F in replacement of electric blower motor capacity 1/8 HP SP 230V, 50Hz, 1350 RPM for 2 Ton capacity split type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and directed at site.
10S&F in replacement of electric blower motor of capacity 1/13or 1/10 HP SP 230V, 50Hz, 1450 RPM for Split type Air conditioner including testing etc complete all as specified and directed. Make : Gulmarg/GE Motor/Crompton Greaves.
11S&F in replacement of electric blower motor of capacity 1/5 HP SP 230V, 50Hz, 930 RPM for window type Air conditioner including testing etc complete all as specified and directed Make : Gulmarg/GE Motor/Crompton Greaves.
12S & F in replacement of thermostat for window type AC, working on SP, 230V,AC complete all as specified Make : Indfos/ Ranutro
13S & F inreplacement of PCB circuit with remote control for air conditionerof any Make and capacity complete all as specified and directed.Make : Voltas/Carrier/Ranutrol/LG/Blue star
14S & F in replacement of air filter for split type Air conditioner (set of three Nos) Make :Marcon or other equivalent approved by GE complete all as specified and directed.
15S & F in replacement of air filter washable of Nilon mesh suitable for window type air conditioner complete all as specified and directed Make : Marcon or other equivalent as approved by GE.
16S & F in replacement of starting capacitor 150 to 200 MFD, 440 volts AC ( Suitable for 2 TR split AC) complete all as specified and directed.Make : Asian/Empire
17S & F in replacement of starting capacitor 100 to 120 MFD, 440 volts AC ( Suitable for 1.5 TR window type AC) complete all as specified and directed.Make : Asian/Empire
18S & F in replacement of running capacitor 36/45 MFD, 440 volts AC ( Suitable for 1.5 TR window AC) complete all as specified and directed. Make : Asian /Empire
19S & F in replacement of capacitor 6 MFD, 440 volts AC ( Suitable for fan motor) complete all as specified and directed. Make : Asian /Empire
20S & F in replacement of relay box type model-KCH 5230004 Make : Usha/Arvind/Voltas
21S & F copper filter pencil type of any make and capacity for Air conditionercomplete all as specified and directed. Make : VaishaliMetal or other equivalent as approved by GE.
22S&F in repair front PVC grill of window type AC of any make complete all as specified and directed at site.
23S & F in replacement of selector switch of window type AC complete all as specified and directed. Make: Blue star/Voltas
24S & F relay over load protector complete set suitable for AC complete all as specified and directed.
25S & F in replacement of relay box type model-AC85004 /AC 85001 operating on SP 230 Volt, AC, Make : Usha/Arvind/Voltas
26S&F in repair indoor unit suitable for 1.5 TR split AC Make :voltas/LG / Samsung with complete blower, remote senser with remote, conrtolling unit, swinging arrangement and air filter complete all as specified and directed.
27S&F in repairoutdoor unit of split AC 1.5 Ton Make :voltas/LG/ Samsung with complete sealed compressor unit capacity 1.5 Ton and blower ,condenser connecting suction and discharge lines initially filled with refrigerating gas complete all as directed.
28S&F in repairindoor unit suitable for 2.0 TR split AC Make : voltas/ LG / Samsung with complete blower, remote senser with remote, conrtolling unit, swinging arrangement and air filter complete all as specified and directed.
29S&F in repair outdoor unit of split AC2.0 Ton Make : voltas/LG/ Samsung with complete sealed compressor unit capacity 2.0 Ton and blower ,condenser connecting suction and discharge lines initially filled with refrigeratinggas complete all as directed.
30SHIFTING OF AC"S:
31M&L for taking down and removing carefully split type AC complete with connected electric wires, copper tubing, insulation sleeves, outdoor unit fitting bracket etc from exiting placeand fixing the same at new location including necessary transpration, find leakage in system by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including required copper tubing up to 2 running meter cleaning & flushing out complete system and, making the system leak proof, vaccumising the system supply & charging refrigerant gas F-22 (approx 2 Kg) in air conditioner 1.5 Tonto 2.0 ton including necessary making holes into wall for insertion of copper pipe etc and making good the disturbed surface as per existing and testing after installation complete all asdirected by Engineer-in Charge
32M&L for attending compliaints by checking the window type/split type AC of any capacity, Desert cooleretc of any make, size and capacity, and making the same functionable by tightening the connection, checking power point /socket point and replacement of screws, small pieces of wire, etc completeNote:- Petty stores such as insulation tape, screws, small pieces of wires, etc shall be provided by the Contractor without and extra cost.
33S&F in repairs Copper tubing of following sizecomplete:-
343/8” size
355/8 ” size
361” size
371/4 ” size
381/2” size
39Supply and charging of gas R 134a in AC plant of any capacity complete all as specified and directed by Engineer-in-charge.Note:-Gas shall be suppliedin sealed and tested cylinder .
40M&L for repairing existing operating pannels of air conditioner (Cold store) of capacity 1.50/2 TR and making workable of incoming and outgoing connections complete all as specified and directed by Engneer-in-charge.
41M&L for profile insulation of outdoor unit complete all as specified and directed.
42S&F AC contactor three phase 415-660 volts 32 Amps coil voltages 230 Volt as per existing complete all as specified and directed.
43S&F following parts complete all as specified and directed.
44Hand shut valve of size 5/8" Make- Synergn
45Pressure gauge (0-500 PSI)
46Valve 3 way
47Flair nut 3/4" brass
48Dead plug (brass)
49Union
50S&F MCCB four pole 63 Amp 16 KA 415 volts complete all as specifiedMake: HPL/Havells
51S&F in repairs Sheet metal enclosure with earth plug andsocket single pole and neutral with single pole MCB 20 Amps 240 volts complete all as directed.
52S&F in repairs Metal clad plug, 2 pole with earth terminal capacity 20 Amp fixed in existing single pole and neutral enclosure complete.
53S&F in repairs Metal clad socket, 2 pole with earth terminal capacity 20 Amp, fixed in existing single pole and neutral enclosure complete.
54S&F in repairs MCB SP, 240 volts, 5 to 32 Amps, 10KA breaking capacity, "C" type including connection with suitable size aluminium /copper lugs complete all as directed
55M&L for Plug top, 3 pin, 15 Amp, SP, 230V, fixed in repairs complete.
56M&L for Switch socket combination piano type 5/15 Amp, 230 volts AC, fixed in repairs complete.
57DESERT COOLERS :
58S & F in replacement fan motor assembly of 1/7HP, 230V SP, AC complete clamps=04 Nos and water fan 18" sweep complete all as specified and directed. Make :GE Motors/Auc/Crompton/ISI Mark
59S & F in replacement vertical pump/Water mersed pump complete tube operated on SP 230V AC complete all as specified and directed. Make : Crompton/cool- Home/GE Motors/ISI Marked
60S & F inreplacement wood-wool pad complete heavy size (set of three pads) approximately 400 gm weightcomplete all as specified and directed.
61S & F in replacement capacitor 6 MFD, 440V, complete all as specified and directed. Make : Empire/ EPCOS/ Capro/ Asian or ISI Mark
62M&L for Scrapping down the complete existing paint of inside and out side of desert cooler cleaning the surface and applying two coats of synthetic enamel paint over a coat of red oxide primer with sprayer and writing SM/MES No with white black enamel paint complete all as specified and directed.
63S&Fin repairsDesert cooler electric driven single phase having nominalair flow capacity of 5400 cumper hour (peak), Honycab cooling media, water storage tank capacity 95/100 liters, complete with air blower motor and water mersed pump with water level indicator complete all as specified and directed. Make: Bajaj model No. DMH 95 or other equivalentin Symphony / Blue star
64WATER COOLERS :
65Supply, fix & testing of blower motor for water cooler SP 230V 50 Hz AC 1/12 HP 930 RPM with fan of size 12.5" dia completeMake : GE Motor/AUE complete all as specified and directed
66All as per item No 17.01 but 1/20 HP 1350 RPM with fan of 13" diacomplete all as specified and directed.
67All as per item No 17.01 but 1/35 HP,1350 RPM withfan of 10" dia complete all as specified and directed
68All as per item 17.01above but 1/83 HP 1350 RPM and fan of 9" dia complete all as specified and directed.
69S & F in replacement of starting capacitor 40 to 60 MFD, 275 volts complete all as specified and directed. Make- Sharda/Empire/Bhel.
70All as per item No 17.05 above but of 60 to 80 MFD complete all as specified and directed.
71S & F in repairs of running capacitor 10 MFD 440 volts AC complete all as specified and directed Make: EPCOS/ Capro /Asian .
72All as per item No 17.07 above but of 15MFD complete all as specified and directed.
73All as per item No 17.07 above but of25/30 MFD complete all as specified and directed.
74S & F in replacement of thermostat for water cooler up to 150 litres capacity. complete all as specified and directed Make : Ranutrol/Danfoss/Indfos.
75S & F inreplacement of push cock heavy duty brass Chromium plated 15mm bore (to match with existing defective push cock). complete all as specified and directed. Make: King or other equivalent ISI marked as approved by GE
76S & F float valve 15mm bore of PVC rigid type with polythene ball complete all as directed Make : Prayag or other equivalent as approved by GE.
77M&L for Scrapping downthe existing water cooler painting completely ofany capacity cleaning and preparing the surface with necessary putty work and painting the complete body of Water cooler including foundation frame of compressor, condenser etc with one coat of synthetic enamel paint over a coat of red oxide primer withspray painting and writing SM/MES No with white/black paint all as directed.
78S & F starting Relay current type suitable for compressor model= AE 4440M, KCE 443 HAA, CAJ, 34, CAJ 2612M, AE451E, KCE 461 HAE , 513HAE complete, Make-Kirloskar/Tecumseh/ Usha / Arvind
79S & F in repairs of over load protector for compressor of water cooler complete all as specified and directed.
80S & F of copper filter pencil type to any make and capacity of water cooler etc complete all as specified and directed. Make : VaishaliMetal
81S & F in replacement of capillary tubing having 0.050/0.055 bore complete all as specified and directed. Make : Vaishali Metal
82S & F of stop cock 15mm brass heavy duty (minimum weight 360 gm) complete all as specified and directed. Make: Leader, GEM, Jaquar
83S & F inreplacement rubber hose pipe of 20mm size with clip for outlet tray of water cooler approx 1.5 meter long complete all as specified and directed
84M&L for removing the burnt/defective sealed compressor unit of any make from water cooler of capacity 60 litres/hours by cutting of suction and discharge lines and un-screwing the foundation nuts supply and fix of new sealed compressorunit make : Kirloskar/Emmersonmodel : AE 444M or KCE 444 HAA/CAJ34 etc by tightening foundation nuts with new fittings and connecting suction and discharge line with gas welding work etc complete all as specified and directed by EIC.
85All as per item No 17.20 above but water cooler of capacity 80 litres/hours and S&F compressor Make : Kirloskar/Emmerson Model : CAJ 2612M/AE451E/KCE 461etc complete.
86All as per item No 17.20 above but water cooler of capacity 150-150 litres/hours and S&F compressor Make : Kirloskar/Emmerson Model AHR-13/KCJ 513 complete all as specified and directed.
87S & F in replacement PVC 3 core flexible heavy duty copper cable of size 2.5 Sqmm complete all as specified and directed Make : Plaza/Finolex or ISI Mark .
88S & F in replacement PVC 4 core flexible heavy duty copper cable of size 2.5 Sqmm complete all as specified and directed Make : Plaza/Finolex or ISI Mark .
89M & L for repairing, testing the leakage in system by charging of Nitrogen Gas up to 300 PSI and repairing of leakagespots/joints with gas welding work, cleaning and flushing the completewater cooler with gas, making the system leak proof, vacuuming the complete system, supply and charging of Freon-22 Gas approx 1.6 Kg complete for water cooler 40/60/120 litres capacity
90M&L for dismantling of water cooler of any capacity and taking out complete internal assembly ie. inner tank, inlet and out let connection etc and descaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket etc.complete all as specified and directed by EIC.
91M&L for replacement of water cooler inner tank made of stainless steel as per existing with necessary gaskets complete set with drilling work fixing with nut,bolts & washer etc complete for water cooler of 80 litres capacity all as specified and directed.
92All as per item No 17.27 but for water coolar of 150 litres capacity complete all as specified and direct ed at site.
93M&L for replacement of glass wool in 40/60/80/120 litres capacity water coolers by taking out inner outer tank and reassembling in same position including testing complete all as specified and directed.
94M&L for repairing of bottom base and legs of water cooler by providing suitable iron member, as per existing in pieces by necessasry welding work complete all as specified and directed.
95DEEP FREEZER :
96M&L for testing the leakage in system by charging Nitrogen Gas up to 300 PSI and repairing the leakage spots/joints with welding work including supply and replacement of filter pencil type copper and capillary tube of existing dia & length and making the system leakproof vacuuming the system and charging of Gas 134a approx 1.0 Kg and testing after completion all as specified and directed.
97S & F inreplacement of Relay current type and over load protector complete set suitable for compressor Model KCE 336 & KCE 345/2415 all as specified and directed.
98S & F inreplacement of thermostat Auto defrost type for Deep freezer (Refrigeration of any make & capacity) complete all as specified and direct ed at site. Make : Ranutrol/Indfos
99M&L for removing burnt/defective sealed compressorunit from deep freezer of any make by cutting of suction and discharge lines and un-screwing of foundation nuts,Supply and replacing of new sealed compressor unit Make : Kirloskar Model :KCS 410 LAA/KCS 412 LAG/Tecumseh 2415including necessary gas welding making the system leak proof, testing andtightening the foundation nuts with new grounts and connecting suction and discharge line with gas welding work etc complete.
100All as per item No 18.04 above but of compressor Make-Tecumseh Model TSK-1350 complete all as specified and directed.
101S & F relay current type and over load protector complete set suitable for compressor model No KCS 410 LAA or KCS 412 LAG fixed in repairs complete all as specified and directed.
102S & F in replacement of drier filter complete set suitable for deep freezer 215 / 386 litres complete all as specified and directed.
103S & F blower motor for Deep frizerSP 230V20 watts complete with fanincluding testing complete all as specified and directed
104REFRIGERATOR :
105S&F in repairs relay current type and overload protector complete suitable for compressor model KCE336, KCE345 complete all as specified and directed Make : Ranutrol/ Voltas /LG
106S&F in rpeairThermostat auto defrost type for refrigerators any make & capacity 165/310 litres Rerfrigerator complete all as specified and directed. Make : Danfos/Ind foss/Ranutrol
107S&F Vegitable tray as per existing and suitable for refrigerator of 300 litres capacity Make:Godrej, Voltas or whirlpool , LG.
108S&F in repairs evaporator suitable for Voltas/Godrej refrigerators capacityfixed in repairs 286/300 litres complete all as specified and directed.
109M&L for removing burnt/defective sealed compressor unit of any make from any type/Capacity(165/286/300/310 Ltr) of refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit Make Tecumesh, Godrej, Voltas or whirlpool , LG,including necessary gas welding, making the system leak proof, including Repair to leakagesystem by charging of nitrogen gas upto 300PSI, in the refrigeration system, testing and tracing the leakage in system, arresting the leakage with gas welding etc and making the complete system leak proof, vaccumising the system and making refrigerator for smooth functioningand charging of refrigerent gas 134a including necessary testing complete all as specified and directed
110Supply and charging / topping upof gas Freon- 22 complete all as specified and directed Note:- Gas shall be supplied in sealed and tested cylinder of capacity 13.60 Kg each.
111M&L for checking of AC supply electrical/electronics circuitary of water purification system, finding fault and rectification the same with repair of step down transformer 230 volt to 12/24 volts, and replacement of resistance , small pieces of wires etccomplete all as directed .
112S&F in repairof water purifier installed in various building of Infantry school and MH areaincluding replacement of candle 10"" filter set and cartrige, carbon filter and pri filter complete all as directed. Make- Aqua guard/ Beetek
113S&F in repair of water purifier and replacement of solonoid valve, PF nozzle, EVA tube, boul set etc installed in various building of Infantry school and MH areaand made functional complete all as directed. Make- Aqua guard/ Beetek
114M&L for checking the unserviceable plant (such as water cooler, refrigerator, Deep frizeretc) of any make, size and capacity, making the same serviceable functionable by tightening the connection, checking power point including, replacement of screws, small pieces of wire, etc complete Note:- Petty stores such as insulation tape, screws, small pieces of wires, etc shall be provided by the Contractor without any extra cost.
115M&L for removing the burnt/defective sealed compressor unit of Tower typemake from any type of air conditioner capacity 4.0 Ton of 3 phase by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fix new sealed compressor unit make - DaikinModel JT160BCBY1L, Kirloskar or other equivalent as approved by GEby tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as directed.
116S & F inreplacement of PCB circuit with remote control forTower AC air conditionerof capacity4.0 Tonof any Make complete all as specified and directed .Make : Voltas/Lloyd/Blue star
117M&L for repairing leakage in system ofAir conditioner of 4.0 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fix filter pencil type copper cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system and supply & charging refrigerant gas F-22 (approx 7.6 Kg) complete all as specified and directed.
118S&F in replacement of electricCondentioner motor ofcapacity6 P SP 230V, 50Hz,120 W for 4 Ton capacity Tower type Air conditioner of out door unit including testing completecomplete all as specified and directed. Make : Gulmarg/GE Motor/Crompton Greaves
119S&F in replacement of electric Blowermotor of capacity of8 P SP 230V, 50Hz,120 W for 4 Ton capacity Tower type Air conditioner of Indoor unitincluding testing complete all as specified and directed. Make : Gulmarg/GE Motor/Crompton Greaves.
120S&F in replacement of Fan Blade for condentioner motor of Out door unitdia 560X169 capacityfor 4 Ton capacity Tower type Air conditioner including testingcomplete all as specified and directed Make : Gulmarg/GE Motor/Crompton Greaves complete .
121S&F in replacement of Capacitor10 MFD for Fan of condentioner motor of Out door unitdia 560X169 capacityfor 4 Ton capacity Tower type Air conditioner including testing complete all as specified and directedMake : Renutral/ Epcos
122VOLTAGE STABLIZER :
123Taking out of deffective / burnt stablizer from various locations under GE (Maint) Infantry school Mhow of various capacity from 1 KVA to 5 KVA single phase and repair /replacement of the following defective parts and testing complete all as specified and directed. by Engineer-in-charge.
124Terminal strip
125Push button switch
126Rocker switch
127Circuit card from 3 to 5 KVA
128Circuit card from 1 to 2 KVA
129Relay 24 Volts 250 Ohms for 3 to 5 KVA
130Volt meter 0-300 volts size as per sample
131Indicator lamp (red/green)
132Booster /stabliser transformer 230 volts AC for3 to 5 KVA
133Booster / stabliser transformer 230 volts AC for1 to 2 KVA
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail