Tender For Provision Of Fasf At Panagarh; 1 Note ( Applicable For All Items / Parts ) :- The Bidders / Contractors Are Advised To Refer Notes On Boq / SchA Before Entry / Quoting The Rates.Lumpsum Price Workedout By The Tenderer For Buildings Works As Listed In Schedule ‘A’ Part-I. 2 Lumpsum Price Workedout By The Tenderer For Earth Work And Excavationas Listed In Schedule ‘A’ Part-Ii. 3 Lumpsum Price Workedout By The Tenderer For Explosive Limit Boardsas Listed In Schedule ‘A’ Part-Iii. 4 Lumpsum Price Workedout By The Tenderer For Internal Electrification As Listed In Schedule ‘A’ Part-Iv. 5 Lumpsum Price Workedout By The Tenderer For External Electric Supply As Listed In Schedule ‘A’ Part-V. 6 Lumpsum Price Workedout By The Tenderer For External Water Supplyas Listed In Schedule ‘A’ Part-Vi. 7 Lumpsum Price Workedout By The Tenderer For Sewage Disposal As Listed In Schedule ‘A’ Part-Vii. 8 Lumpsum Price Workedout By The Tenderer For Road / Path / Culvert / Hard Standingas Listed In Schedule ‘A’ Part-Viii. 9 Lumpsum Price Workedout By The Tenderer Forarea Drainage As Listed In Schedule ‘A’ Part-Ix. 10 Lumpsum Price Workedout By The Tenderer Forlighting Protection As Listed In Schedule ‘A’ Part-X. 11 Lumpsum Price Workedout By The Tenderer Forrcc Dunnage Blocks As Listed In Schedule ‘A’ Part-Xi. 12 Lumpsum Price Workedout By The Tenderer Forfire Point As Listed In Schedule ‘A’ Part-Xii. 13 Lumpsum Price Workedout By The Tenderer Forchain Link Fencing & Gate As Listed In Schedule ‘A’ Part-Xii. 14 Lumpsum Price Workedout By The Tenderer Fordemolition & Dismantling As Listed In Schedule ‘A’ Part-Xiv. 15 Sch A Part-Xv ( Misc B&R And E&M Items ) Note : This Schedule Is Not Pre-Priced By Mes And The Pre-Priced Rate Indicated As Rs 0.00 Under Col. 5 Siginifies This Fact Only.Site Clearence 16 Material And Labour For Mixing Of Lime @ 2.5% By Weight With Earthin Filling Of Traverse .Note- Only Lime And Mixing With Rotavator Is To Be Paid Under This Item .Laying , Spreading And Compaction Etc Is Incl In Forming Embankment Of Earth. 17 Internal Electrification 18 Supply & Fixing Led Bulb 10 Watt, B22 Suitable For Fitting In Lamp Holder Batten Type Complete All As Specified And As Directed. 19 Supply And Fixingflame Proof Cum Water Proof Led Bulk Head Light Fitting Of 20 Watt, Certified By Cmri, Suitable For Gas / Vapor Group Of Iia & Iiib, Zone 1 & 2 As Per Is-2148 ( 1981 ) And Is-2206 Part-I Having Ip 66 Degree Of Protection, Cast Aluminum Alloy Material And Heat And Impact Resistance Toughen A Clear Glass Having Anti Corrosive Epoxy Powder Coated Finish Complete With All Accessories Pre Wired And Including Connected Up With Three Core Flexible Copper Conductor Cable With Suitable Size Complete All As Specified And As Directed. . 20 Supply And Fixingflame Proof Led Light Fitting 40 Watt, Certified By Cmri, Suitable For Gas / Vapor Group Of Iia & Iiib, Zone 1 & 2 As Per Is-2148 ( 1981 ) And Is-2206 Part-I Having Ip 65 Degree Of Protection As Per Is-2147 ( 1962 ) Of Die Cast Aluminum Alloy Lm-6 Construction, Light Grade Epoxy Powder Coating Finish Of Shade Number 631 As Per Is-5 Having Provisioning Of One Number Internal Earth And Two Numbers External Screws Of M4 / M5 Size O Ring Endless Neoprene Rubber Gasket, Stainless Steel Hardware, Two Number 3 / 4 Inch Cable Entry, Cable Glands, All Internal Electrical Components Pre-Wired, Inside White And Outside Light Gray, Internal Driver Type Epoxy Powder Coating, Clear Heat Resistance Well Glass Complete All As Specified And As Directed. . 21 Supply And Fixing Flame Proof Distribution Board, Flame Proof As Certified By Cmri, Spn 8 Way With Din Rail, Suitable For Isolators, Mcbs And Elcbs, Suitable For Group-I, Iib As Per Is 2148 ( 1981 ) , Ip-65 As Per Is-2147 ( 1962 ) , Cast Aluminium Alloy Lm-6 Conastruction, Light Gray Epoxy Shade No 632 Of Is-5 Powder Coating Having Having O Ring Neoprene Rubber Gasket, Hardware In External Steel Construction Complete All As Specified And Directed. ( Note:- Isolators, Mcbs And Elcbs Shall Be Measured And Paid Separately ) . 22 External Electric Supply 23 Supply Laying Old Size Fly Ash Brunt Building Bricks, Laid In Trenchesover Sand Cushion Laid With Axis Of Bricks Perpendicular To The Axis Of Lt Cable For Cable Protection, Complete All As Specified And As Directed. 24 Dismentling / Taking Down Of Cradles Hexagonal / Rectangular Fabricated With Galvanised Steel Wire Any Shape And Size Complete All As Specified And As Directed. 25 Taking Down Old U / S Danger Notice Plate Any Type And Size Complete All As Specified And As Directed. 26 Taking Up / Out Ht Ug Cables Of Any Cross Sectional Area And Connections And Joints Including Pipes, Bricks, Etc Of Size 120 Sqmm 3 Core Laying In Trenches Or Fixing With Walls / Poles, Segreating Serviceable Bricks / Precast Covers, Pipes, Cables Etc, And Keep In Safe Custody For Reuse, Complete All As Specified And As Directed. 27 Relaying Of Ht Ug Cable ( Serviceable Cable Obtained From Item No. 24 Here-In- Before ) Of Size 120 Sqmm 3 Core Complete All As Specified And As Directed. Note : Earthworks, Sand Cushioning, Pre-Cast Concrete Cable Cover, Gi Pipe, Etc. Will Be Measured And Paid Under Appropriate Items. 28 Boring Holes Horizontally Under Road Without Damaging The Surface Of Road ( Minimum 1.0 Metre Below The Road Surface / Footpath With The Help Of Gi Tubing Not Exc. 80Mm Bore ( Dia ) For Passing Of Ug Cable, Complete All As Specified And As Directed.Note: Gi Pipe Laid Will Be Measured And Paid Separately Under Appropriate Item. 29 M & L For Cable Route Indicator Of Cast Iron For Lt / Ht Cable ( Colour Brown / Blue Respectively ) With 35X35x4mm Ms Angle Iron Post 1.00 Mtr Long Embedded In Pcc 1:3:6 Type C1 Foundation Concrete 150Mm X 150Mm X 300Mm Deep Complete All As Specified And As Directed. 30 Supply , Install, Testing And Commissioning Of Lt Panel Board Outdoor Type, Cpri Approved, Platform Mounted Factory Made Of Size 1.2 X 1.0 X 0.6M, Totally Enclosed Dust And Vermin Proof Openablefrom Both Front And Rear Side Made Out Of 14 Swg ( 3 Mm ) Thick Crcams Sheet And Built Upon Suitable Size Angle Ironframe Work , Having Front And Rear Hinged Doors, Lifting Lugs ( 2 Nos ) , Earthing Strips At Rear Side , Bottom Detachable Gland Plate Complete With Suitable Size Zinc Plated And Passivated Nut, Bolts , Spring And Washers.The Cabinet And All Members Should Be Chemically Treated With Msr Solution For Anticorrosive Treatment And Apply Spray Paint With Two Coat Of Synethetic Enamel Paintover A Coat Of Red Oxide Primer. The Panel Should Be Suitable For 415 Volts , 50Hz , 3 Phase4 Wire Systemand Internal Connection Should Be Provided With Copper Strips Of Suitable Size, 04 Nos Copper Bus Bar 200 Amps And Necessary Foundation Workand Comprisingfollowing:- 31 ( A ) Incoming Mccb, 4 Pole, 125 Amps, 415 Volt Ac, 35 Ka Rupturing Capacity --01 No. ( B ) Ougoing Mccb, 4 Pole, 100 Amps, 415 Volt Ac, 25 Ka Rupturing Capacity --03 Nos. ( C ) Ougoing Mcb Tpn 10 Amps, 10 Ka, C Series, 415 Volts--02 Nos. ( D ) Changeover Switch 125 Amps 415 Volts--01 No. ( E ) Voltmeter & Ammeter With Selector Switch. 32 Supply , Install, Testing And Commissioning Of Lt Panel Board Outdoor Type, Cpri Approved, Platform Mounted Factory Made Of Size 1.2 X 1.0 X 0.6M, Totally Enclosed Dust And Vermin Proof Openablefrom Both Front And Rear Side Made Out Of 14 Swg ( 3 Mm ) Thick Crcams Sheet And Built Upon Suitable Size Angle Ironframe Work , Having Front And Rear Hinged Doors, Lifting Lugs ( 2 Nos ) , Earthing Strips At Rear Side , Bottom Detachable Gland Plate Complete With Suitable Size Zinc Plated And Passivated Nut, Bolts , Spring And Washers.The Cabinet And All Members Should Be Chemically Treated With Msr Solution For Anticorrosive Treatment And Apply Spray Paint With Two Coat Of Synethetic Enamel Paintover A Coat Of Red Oxide Primer. The Panel Should Be Suitable For 415 Volts , 50Hz , 3 Phase4 Wire Systemand Internal Connection Should Be Provided With Copper Strips Of Suitable Size, 04 Nos Copper Bus Bar 160 Amps And Necessary Foundation Workand Comprisingfollowing:- 33 ( A ) Incoming Mccb, 4 Pole, 100 Amps, 415 Volt Ac, 35 Ka Rupturing Capacity --01 No. ( B ) Ougoing Mcb, 2 Pole, 40 - 63 Amps, 10 Ka, C Series, 230 Volt Ac -- 05 Nos. ( C ) Outgoing Mcb Tpn 10 Amps, 10 Ka, C Series, 415 Volts--03 Nos. ( D ) Time Switches 415 V Three Phase Of 20 Amp Rating With Contactor--01 No. ( E ) Voltmeter & Ammeter With Selector Switch. 34 Supply And Fixing Led Street Light Fitting 45 Watt 230 V Ac, Luminous Efficacy 120 Lumens / Watt Outdoor Type With High Pressure Die Cast Aluminum Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65 / 66 Protection Including Gi Bracket Of Required Shape & Size As Recommended By Manufacturer, Clamp Of Required Length Including Nuts & Bolts Fixed On Street Poles Complete. Make: Jaquar, Model No:Lsrt02s045xc Or Equivalent In Havells / Bajaj. ( Note:- 34 Nos Street Light To Be Fitted On Lt Oh Line Pole ) 35 Supply And Fix Junction Box With Terminals Of Size 155 X 210 X 92Mm Or Nearest Higher Size Made Of Polycarbonate Body With Ip 66 / 67 Degree Of Protection, Dust Proof, Water Tight, Shock Proof, Fire Retardant, With Internally Embedded Gasket Fitted With Heat Treated Bakelite Terminals Block And Pvc Glands For Cable Entry Complete All As Directed. Make: Hensel; Cat No-Kf1616g. 36 Supply, Laying & Testing Pvc Insulated, Pvc Sheathed Electric Control Cables ( Heavy Duty ) With Stranded Copper Conductor Of Size 1.5 Sq Mm, 3 Core, 1100 Volts Grade To Connect Street Light To Junction Box Complete All As Specified And As Directed. 37 Supply And Fixing Led Search Light With Mororised System, Led Light Should Be 300Watt, 230 V Long Range Type With Horizontal & Vertical Operational Controls By Remote Control Unit. 38 Supply And Fixing All-In-One Outdoor Solar Led Street Light 30 Watt With Minimum 150 Lumens, With In Built Scc, 100Wp High Efficiency Mono Crystalline Solar Pv Module, Minimum 12.8 V, 36 Ah Capacity Lithium Ferro Phosphate Battery, Hdg Tubular Pole 7 Mtr Complete All As Specified And As Directed. Make: Havells / Bajaj / Jaquar. Note: Pcc Foundation To Erect The Solar Light Pole Shall Be As Per Manufacturer Recommendation And Included In Item Rate. 39 External Water Supply 40 Supply And Laying Of Pipe Ductile Iron, Socket & Spigot Type, Class “K-9”, 200 Mm Nominal Dia Complete All As Specified And As Directed. 41 Supply And Laying Of Pipe Ductile Iron, Socket & Spigot Type, Class “K-9”, 150 Mm Nominal Dia Complete All As Specified And As Directed. 42 Supply And Laying Of Pipe Ductile Iron, Socket & Spigot Type, Class “K-9”, 100 Mm Nominal Dia Complete All As Specified And As Directed. 43 Material & Labour For Di Specials Like Bends ( Any Type, Radius And Angle ) Tapers Any Type ( Straight, Bend, Increasing, Decreaing Or Double Socket Etc ) Tee Pieces Single Branch Y Junction, Double Branch, Cross For Di Pipe Upto 200 Mm Bore Complete All As Specified And As Directed. 44 M & L Construction Of Brick Masonrychamber Of 90 Cm X 90 Cmx 90 Cm [ Internal Dimensions ] Suitable For 150 Mm / 200 Mm Bore Sluice Valve With Pcc 1:4:8 Type D2 Using 40 Mm Graded Stone Aggregate For Foundationbrick Wall With Sub Class ‘B’ Brick, Oldsize Built In Cm1:6 Pcc [ 1:2:4 ] Type B1 [ Using 20 Mm Graded Stone Aggregate For Coping Rendering In Cm [ 1.4 ] 15 Mmthick Including Provision Of Ms Sheet Cover 3 Mm Thick With Two Coats Of Synthetic Enamel Paint Over A Coat Ofred Oxideprimer To Steel Surfaces And Locking Arrangement Including Necessary Excavation And Earth Work In Any Type Of Soil Complete All As Specified. 45 M & L Construction Of Brick Masonrychamber Of 60 Cm X 60 Cmx 60 Cm [ Internal Dimensions ] Suitable For 50Mm Bore Sluice Valve With Pcc 1:4:8 Type D2 Using 40 Mm Graded Stone Aggregate For Foundationbrick Wall With Sub Class ‘B’ Brick, Oldsize Built In Cm1:6 Pcc [ 1:2:4 ] Type B1 [ Using 20 Mm Graded Stone Aggregate For Coping Rendering In Cm [ 1.4 ] 15 Mmthick Including Provision Of Ms Sheet Cover 3 Mm Thick With Two Coats Of Synthetic Enamel Paint Over A Coat Ofred Oxideprimer To Steel Surfaces And Locking Arrangement Including Necessary Excavation And Earth Work In Any Type Of Soil Complete All As Specified. 46 Road / Path / Culvert 47 Material & Labour For Mixing Of Fly Ash, Clinker & Stone Dust In Proportion Of 1:3 :6 ( I.E 10% Fly Ash, 30% Clinker And 60% Stone Dust Materials ) Laying Thickness Of 600Mm ( Compacted Thickness ) In 3 Layers , Watering , Ramming And Compacting With Vibratory Roller To Get Min Cbr Value 8% And Dry Density 97 % Placed At Required Camber And Gradient Completeas Directed By Engr-In-Charge 48 Material & Labour For 225 Mm Th ( Compacted Th ) Wet Mix Macadam ( Wmm ) ( Laid In Three Layer Of 75Mm Each ) Using 40Mm Graded Aggregates , Spread Using Mechanical Paver As Specifed, Rolled With Power Roller Exc 10 Tonne Not Exc 12 Tonne And Consolidated As Specifiedgradient And Camber Complete As Specified And As Directed. 49 Material & Labour For Cleaning And Preparing The Road Surface And Marking Good For Road Marking Applying Reflective Thermoplastic White Road Marking Paint ( Hot Application ) Conforming To Bis 3262 Laid Down Through Modern Propelled Road Marking Machine In A Layer Of Crystalex And Use Of All Ingredients Such As Binder, Glass , Beads, Titanium Dioxide , Calcium Carbonate , Interfiller Thermoplastic Reqd For Glass Beads Per Sqm By Incorporating The White Glass Beads For Reflectivity In 100Mm Width Complete All As Specified And Directed. 50 Fire Fighting System 51 Supply And Fixing Portable Fire Extinguisher Water Co2 Type, 9 Ltr Capacity Confirming To Is:940 / 6234Suitable For Fire Fighting System. 52 Supply And Fixing Portable Fire Extinguisher Powder Type Suitable For Fire Type A B Or C, Of 10 Kg Capacity Confirming To Is: 13849 / 14609Suitable For Fire Fighting System. 53 Supply And Fixing Portable Fire Extinguisher Co2 Type, 5 Kg Capacity Confirming To Is:2878Suitable For Fire Fighting System. 54 Supply And Fixing Ceiling Hook Confirming To Is:927Suitable For Fire Fighting System 55 Supply And Fixing Fire Beater Confirming To Is:8096Suitable For Fire Fighting System 56 Supply And Fixing Fire Bucket Made Out Of Ms Irin, 9 Ltr Capacity Confirming To Is:2546Suitable For Fire Fighting System. 57 Supply And Fixing Shovelsuitable For Fire Fighting System 58 Supply And Fixing Fire Gong / Hand Siren Confirming To Is: 6026 Suitable For Fire Fighting System 59 Supply And Fixing Fire Axe Suitable For Fire Fighting System 60 Digitel Temp & Humidity Meter 61 Supply, Testing, Commissioning And Fixing Of Temperature & Humidity Data Logger With The Following Specifications:- ( A ) Max / Min : Temperature Reading Over 0 To 100% Rh :40 Degree Celsius To 70 Degree Celsius. ( B ) Measurement Ranges By Pc With Usb Interface With Data Card And Lcd Monitor ( C ) Memory For 32700 Readings ( 16350 Temperatures And 16350 Humidity Readings ) With Long Life Battery Pack With Accessories Including Locking Arrangement Complete With Fixing On Wall. 62 Electric Siren 63 Supply, Install, Test And Commission Electric Motor Siren For Heavy-Duty Application, Ideal Auidable Range ( Diametrical ) 8.0 Kms, Motor 5 Hp ( 2880 Rpm ) Insulation Class F / B, Ip-44 , 415 Volts, 3 Phase, Frequency 50 Hz, Aluminium Casting Bodied, Horizontal Impeller Complete With All Mounting And Accessories Including Canopy Made Out Of Ms Channel, Cgi As Required To Protect From Heavy Rain Fall Complete All As Specified And As Directed. 64 Supply And Fix Dol Starter Suitable For Electric Motor Upto 5 Hp, 415 Volts, 3 Phase Complete All As Specified And As Directed. 65 Dg Set 66 Supply, Installation, Testing And Commissio-Ning Silent Diesel Engine Driven Generating Set 415 Volts, 3 Phase 4 Wire, Engine As Per Is:10001 / 10002 And Alternator As Per Is: 13364 Complete With Relay Panel And Switch Gears For Automatic Starting On Main Failure, Control Panel Having Meter And Sound Proof Canopy As Per Cpcb Norms And Foundation Etc. Of Capacity 50 Kva.Technical Specification : Stroke- 4, No. Of Cylinders- 4, Rpm- 1500, Cyl. Configuration - Vertical Lnline, Dirction Of Rotation - Counter Clockwise Viewed From Flywheel End, Method Of Aspiration- Turbo Charged After Cooled, Method Of Cooling- Coolant Cooled, Type Of Governor- Electronic, Starting System-12V Electric Start, Overload Capacity- 10% For 1Hr. In Every 12Hrs. Running, Duty- Continuous, Safety Control- Low Lube Oil Pressure, High Coolant Temp, Applicable Standards - Iso 3046, Bs 5514, Bore & Stroke- 97X128mm, Displacement-3.84Ltrs, Compres-Sion Ratio-17.5 :1, Lube Oil Sump Cap- 9 Ltrs, Coolant Capacity With Engine Jacket- 15 Ltrs. 67 Alternator. Rating: 50Kvatype: Brushless, Excitation: Self Excited, Self Regulated ( Avr ) , Enclosure: Spdp, Enclosure Protection: Ip-23, Rating: Continuous, Rated Voltage: 415V, No Of Phases: 3Ph, Rated Current: 50Kva-208Amps, Frequency: 50Hz, Power Factor: 0.8Pf, Class Of Insulation: H, Voltage Regulation: + 1%, Overload Capacity10% For 1Hr For Every 12Hrs Running, Applicable Standards: Is 4722 / Bs 5000.Accessories. Fuel Tank Suitable For 8Hrs. Capacity Shall Be Supplied And To Be Mounted Inside The Canopy, Exide Make Batteries 1 No.X12v, 90Ah Capacity, Battery Lead, Anti-Vibration Mounting Pads ( Fitted Inside The Canopy ) , Residential Silencer ( Fitted On Inside / Top Of Canopy ) , First Fill Of Lube Oil & Coolant. 68 Amf Control Panel. The Amf Control Panel Shall Be Made Of 16Swg Crca Sheet, Set / Floor Mounted, Indoor Type, Dust And Vermin Proof And Powder Coated And Suitable For 415V, 3Phase, 50Hz System. The Panel Will Be Incorporated Inside The Canopy And Shall Consist Of The Following Features: Microprocessor Based Amf Controller Having Safety Features With Display Of Following Engine & Alternator Parameters:- Engine Display Features-Low Lube Oil Pressure, High Water Temperature, Overspeed, Low Fuel Level, Rpm, No. Of Hours Run, Battery Voltage. Safeties- Llop, Hwt, Lfl, Over Speed & Earth Fault Relay. Alternator Display Features- Ampere, Voltage, Frequency, Power Factor, Kw, Kwh, Kvar. Safeties- Over Current, Over / Under Frequency, Short Circuit, Current Transformers Of Suitable Ratio, 2 Nos Suitalby Rated 4 Pole Power Contactor For Dg & Mains, 1 No. Suitably Rated Mccb With Short Circuit & Overload Protection As Outgoing, Indicating Lamps For Dg On / Load On / Mains On, Mcb For Control Protection, Battery Charger With Auto Trickle & Boost Charging Facility, Toggle Switch For Control On / Off. Note: All Engine & Alternator Parameters Will Be Displayed Through Above Controller Only. 69 Acoustic Enclosure. Acoustic Enclosure Should Be Fcri Approved And Made Of Specially Procured 16Swg Crca Sheet And Structural Sheet Metal Base Frame And Comply With Cpcb / Grihanorms With Following Features:- The Most Compact, Six Sided, Close, Modular Construction And Detachable. Meet Cpcb / Moef Norms. Sound Level<75 Dba At One Meter Distance Under Free Field Conditions As Per Norms. Easy Accessibility Around The Dg Set, Which Ensures Optimum Serviceability. Special Powder Coated Enclosure, Weather Proof, Corrosion Resistant, Environment Friendly. Specially Designed Lifting Hooks. Use Of High Quality Hardware Ensure Longer Life Of Enclosure. Provision For Emergency Stop Facility. Fuel Tank Of 8Hrs. Running Capacity Is Specially Designed And Mounted Inside The Enclosure As An Integral Part Of Acoustic Enclosure. Foundation / Plinth / Base : Shall Be Provided As Per Manufacturers Recommendations Included In Quoted Rate Of Contractor.Also Necessary Connection From Main Panel To Dg Panel With Cables As Per Load To Be Included In Quoted Rate Of Contractor.Note: Rcc Platform To Mount Dg Set Shall Be As Per Manufacturer Recommendation And Included In Item Rate. 70 Demolition & Dismantling 71 Taking Down Db / Main Switch Of Any Size And Making Good Disturbed Surface Of Wall / Floor Complete All As Specified.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Nov-2023 First Corrigendum Date 02-12-2023
2 25-Nov-2023 SECOND CORRIGENDUM Date 09-12-2023
3 01-Dec-2023 THIRD CORRIGENDUM Date 16-12-2023
4 08-Dec-2023 Fifth Corrigendum Date 23-12-2023
5 08-Dec-2023 Fourth Corrigendum Other 23-12-2023
6 08-Dec-2023 Fourth corrigendum BOQ 23-12-2023
7 14-Dec-2023 DATE CORRIGENDUM Date 28-12-2023
8 14-Dec-2023 DRG1 Other 28-12-2023
9 14-Dec-2023 DRG Other 28-12-2023
10 14-Dec-2023 SIXTH CORRIGENDUM Other 28-12-2023
11 20-Dec-2023 EIGHT CORRIGENDUM Other 28-12-2023
12 26-Dec-2023 NINETH CORRIGENDUM Other 28-12-2023

Key Value

Document Fees
INR 3000 /-
EMD
INR 2575000.0 /-
Tender Value
INR 29.63 Crore /-

BOQ Items

Name of Work :PROVN OF FASF AT PANAGARH
Sl. No. Item Description
1NOTE (Applicable for all items/parts):- The bidders/contractors are advised to refer Notes on BOQ/SCH"A" before entry/quoting the rates. Lumpsum price workedout by the tenderer for BUILDINGS WORKS as listed in Schedule ‘A’ Part-I.
2Lumpsum price workedout by the tenderer for EARTH WORK AND EXCAVATIONas listed in Schedule ‘A’ Part-II.
3Lumpsum price workedout by the tenderer for EXPLOSIVE LIMIT BOARDSas listed in Schedule ‘A’ Part-III.
4Lumpsum price workedout by the tenderer for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-IV.
5Lumpsum price workedout by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-V.
6Lumpsum price workedout by the tenderer for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VI.
7Lumpsum price workedout by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII.
8Lumpsum price workedout by the tenderer for ROAD/PATH/CULVERT/ HARD STANDINGas listed in Schedule ‘A’ Part-VIII.
9Lumpsum price workedout by the tenderer forAREA DRAINAGE as listed in Schedule ‘A’ Part-IX.
10Lumpsum price workedout by the tenderer forLIGHTING PROTECTION as listed in Schedule ‘A’ Part-X.
11Lumpsum price workedout by the tenderer forRCC DUNNAGE BLOCKS as listed in Schedule ‘A’ Part-XI.
12Lumpsum price workedout by the tenderer forFIRE POINT as listed in Schedule ‘A’ Part-XII.
13Lumpsum price workedout by the tenderer forCHAIN LINK FENCING & GATE as listed in Schedule ‘A’ Part-XII.
14Lumpsum price workedout by the tenderer forDEMOLITION & DISMANTLING as listed in Schedule ‘A’ Part-XIV.
15Sch "A" Part-XV (MISC B&R AND E&M ITEMS) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only. SITE CLEARENCE
16Material and labour for mixing of lime @ 2.5% by weight with earthin filling of traverse .Note- Only lime and mixing with rotavator is to be paid under this item .laying ,spreading and compaction etc is incl in forming embankment of earth.
17INTERNAL ELECTRIFICATION
18Supply & fixING LED bulb 10 watt, B22 suitable for fitting in lamp holder batten type complete all as specified and as directed.
19Supply and fixingflame proof cum water proof LED bulk Head light fitting of 20 Watt, certified by CMRI, suitable for gas/ vapor group of IIA & IIIB, Zone 1 & 2 as per IS-2148 (1981) and IS-2206 Part-I having IP 66 degree of protection, cast aluminum alloy material and heat and impact resistance toughen "A" clear glass having anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connected up with three core flexible copper conductor cable with suitable size complete all as specified and as directed. .
20Supply and fixingflame proof LED light fitting 40 Watt, certified by CMRI, suitable for gas/ vapor group of IIA & IIIB, Zone 1 & 2 as per IS-2148 (1981) and IS-2206 Part-I having IP 65 degree of protection as per IS-2147 (1962) of die cast aluminum alloy LM-6 construction, light grade epoxy powder coating finish of shade number 631 as per IS-5 having provisioning of one number internal earth and two numbers external screws of M4/M5 size "O" ring endless neoprene rubber gasket, stainless steel hardware, two number 3/4 inch cable entry, cable glands, all internal electrical components pre-wired, inside white and outside light gray, internal driver type epoxy powder coating, clear heat resistance well glass complete all as specified and as directed. .
21Supply and fixing flame proof distribution board, flame proof as certified by CMRI, SPN 8 way with DIN rail, suitable for isolators, MCBs and ELCBs, suitable for group-I, IIB as per IS 2148 (1981), IP-65 as per IS-2147 (1962), cast aluminium alloy LM-6 conastruction, light gray epoxy shade No 632 of IS-5 powder coating having having "O" ring neoprene rubber gasket, hardware in external steel construction complete all as specified and directed. (Note:- Isolators, MCBs and ELCBs shall be measured and paid separately).
22EXTERNAL ELECTRIC SUPPLY
23Supply laying old size fly ash brunt building bricks, laid in trenchesover Sand Cushion laid with axis of bricks perpendicular to the axis of LT cable for Cable Protection, complete all as specified and as directed.
24Dismentling / Taking down of cradles hexagonal / rectangular fabricated with galvanised steel wire any shape and size complete all as specified and as directed.
25Taking down old U/S Danger Notice Plate any type and size complete all as specified and as directed.
26Taking Up/Out HT UG Cables of any Cross Sectional Area and connections and joints including Pipes, Bricks, etc of size 120 Sqmm 3 core laying in trenches or fixing with Walls/Poles, segreating serviceable Bricks/Precast covers, Pipes, Cables etc, and keep in safe custody for reuse, complete all as specified and as directed.
27Relaying of HT UG cable (Serviceable cable obtained from Item No. 24 here-in- before) of size 120 Sqmm 3 core complete all as specified and as directed. NOTE : Earthworks, Sand Cushioning, Pre-cast concrete cable cover, GI Pipe, etc. will be measured and paid under appropriate Items.
28Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface / footpath with the help of GI Tubing not exc. 80mm bore (dia) for passing of UG Cable, complete all as specified and as directed. NOTE: GI Pipe laid will be measured and paid separately under appropriate Item.
29M & L for cable route indicator of cast iron for LT/HT cable (Colour Brown/Blue respectively) with 35x35x4mm MS angle iron post 1.00 Mtr long embedded in PCC 1:3:6 type C1 foundation concrete 150mm x 150mm x 300mm deep complete all as specified and as directed.
30Supply , install, testing and commissioning of LT panel board outdoor type, CPRI approved, platform mounted factory made of size 1.2 x 1.0 x 0.6m, totally enclosed dust and vermin proof openablefrom both front and rear side made out of 14 SWG (3 mm) thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paintover a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with copper strips of suitable size, 04 Nos copper bus bar 200 Amps and necessary foundation workand comprisingfollowing:-
31(a) Incoming MCCB, 4 pole, 125 Amps, 415 Volt AC, 35 KA rupturing capacity --01 No. (b) Ougoing MCCB, 4 pole, 100 Amps, 415 Volt AC, 25 KA rupturing capacity --03 Nos. (c) Ougoing MCB TPN 10 Amps, 10 kA, "C" series, 415 volts--02 Nos. (d) Changeover switch 125 Amps 415 Volts--01 No. (e) Voltmeter & Ammeter with selector switch.
32Supply , install, testing and commissioning of LT panel board outdoor type, CPRI approved, platform mounted factory made of size 1.2 x 1.0 x 0.6m, totally enclosed dust and vermin proof openablefrom both front and rear side made out of 14 SWG (3 mm) thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paintover a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with copper strips of suitable size,04 Nos copper bus bar 160 Amps and necessary foundation workand comprisingfollowing:-
33(a) Incoming MCCB, 4 pole, 100 Amps, 415 Volt AC, 35 KA rupturing capacity --01 No. (b) Ougoing MCB, 2 pole, 40 - 63 Amps, 10 kA, "C" series, 230 Volt AC -- 05 Nos. (c) Outgoing MCB TPN 10 Amps, 10 kA, "C" series, 415 volts--03 Nos. (d) Time switches 415 V three Phase of 20 Amp rating with contactor--01 No. (e) Voltmeter & Ammeter with selector switch.
34Supply and fixing LED street light fitting 45 Watt 230 V AC, luminous efficacy 120 Lumens/Watt outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including GI bracket of required shape & size as recommended by manufacturer, clamp of required length including nuts & bolts fixed on street poles complete. Make: Jaquar, Model No:LSRT02S045XC or Equivalent in Havells/Bajaj. (Note:- 34 Nos street light to be fitted on LT OH Line Pole)
35Supply and fix Junction box with terminals of size 155 x 210 x 92mm or nearest higher size made of polycarbonate body with IP 66/67 degree of protection, dust proof, water tight, shock proof, fire retardant, with internally embedded gasket fitted with heat treated bakelite terminals block and PVC glands for cable entry complete all as directed. Make: Hensel; Cat No-KF1616G.
36Supply, laying & testing PVC insulated, PVC sheathed electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm, 3 core, 1100 Volts grade to connect street light to junction box complete all as specified and as directed.
37Supply and fixing LED Search light with mororised system, LED light should be 300Watt, 230 V long range type with horizontal & vertical operational controls by remote control unit.
38Supply and fixing All-in-one outdoor solar LED street light 30 watt with minimum 150 lumens, with in built SCC, 100Wp high efficiency Mono Crystalline Solar PV Module, minimum 12.8 V, 36 Ah capacity Lithium Ferro Phosphate battery, HDG Tubular Pole 7 mtr complete all as specified and as directed. Make: Havells/Bajaj/Jaquar. Note: PCC foundation to erect the Solar light pole shall be as per manufacturer recommendation and included in item rate.
39EXTERNAL WATER SUPPLY
40Supply and laying of pipe ductile Iron, socket & spigot type, Class “K-9”, 200 mm nominal dia complete all as specified and as directed.
41Supply and laying of pipe ductile Iron, socket & spigot type, Class “K-9”, 150 mm nominal dia complete all as specified and as directed.
42Supply and laying of pipe ductile Iron, socket & spigot type, Class “K-9”, 100 mm nominal dia complete all as specified and as directed.
43Material & labour for DI specials like Bends (any type, radius and angle) tapers any type (straight, bend, increasing,decreaing or double socket etc) Tee pieces single branch "Y" junction, double branch, cross for DI pipe upto 200 mm bore complete all as specified and as directed.
44M & L Construction of brick masonrychamber of 90 cm x 90 cmx 90 cm [internal dimensions] suitable for 150 mm/200 mm bore sluice valve with PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundationbrick wall with sub class ‘B’ brick, oldsize built in CM1:6 PCC [1:2:4] type B1 [using 20 mm graded stone aggregate for coping rendering in CM [1.4] 15 MMthick including provision of MS sheet cover 3 mm thick with two coats of synthetic enamel paint over a coat ofred oxideprimer to steel surfaces and locking arrangement including necessary excavation and earth work in any type of soil complete all as specified.
45M & L Construction of brick masonrychamber of 60 cm x 60 cmx 60 cm [internal dimensions] suitable for 50mm bore sluice valve with PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundationbrick wall with sub class ‘B’ brick, oldsize built in CM1:6 PCC [1:2:4] type B1 [using 20 mm graded stone aggregate for coping rendering in CM [1.4] 15 MMthick including provision of MS sheet cover 3 mm thick with two coats of synthetic enamel paint over a coat ofred oxideprimer to steel surfaces and locking arrangement including necessary excavation and earth work in any type of soil complete all as specified.
46ROAD/PATH/CULVERT
47Material & Labour for mixing of fly ash, clinker & stone dust in proportion of 1:3 :6 (i.e 10% Fly ash, 30% Clinker and 60% Stone dust materials) laying thickness of 600mm(compacted thickness) in 3 layers , watering , ramming and compacting with vibratory roller to get min CBR value 8% and Dry density 97 % placed at required camber and gradient completeas directed by Engr-in-Charge
48Material & Labour for 225 mm th (compacted th) wet mix macadam (WMM) (laid in three layer of 75mm each) using 40mm graded aggregates , spread using mechanical paver as specifed, rolled with power roller exc 10 tonne not exc 12 tonne and consolidated as specifiedgradient and camber complete as specified and as directed.
49Material & Labour for cleaning and preparing the road surface and marking good for road marking applying reflective thermoplastic white road marking paint (Hot application) conforming to BIS 3262 laid down through modern propelled road marking machine in a layer of CRYSTALEX and use of all ingredients such as binder, glass ,beads,titanium dioxide ,calcium carbonate ,interfiller thermoplastic reqd for glass beads per Sqm by incorporating the white glass beads for reflectivity in 100mm width complete all as specified and directed.
50FIRE FIGHTING SYSTEM
51Supply and fixing Portable Fire Extinguisher water CO2 type, 9 ltr capacity confirming to IS:940/6234suitable for fire fighting system.
52Supply and fixing Portable Fire Extinguisher powder type suitable for fire type A B or C, of 10 Kg capacity confirming to IS: 13849/14609suitable for fire fighting system.
53Supply and fixing Portable Fire Extinguisher CO2 type, 5 Kg capacity confirming to IS:2878suitable for fire fighting system.
54Supply and fixing Ceiling Hook confirming to IS:927suitable for fire fighting system
55Supply and fixing Fire beater confirming to IS:8096suitable for fire fighting system
56Supply and fixing Fire bucket made out of MS Irin, 9 ltr capacity confirming to IS:2546suitable for fire fighting system.
57Supply and fixing Shovelsuitable for fire fighting system
58Supply and fixing Fire gong/ hand siren confirming to IS: 6026 suitable for fire fighting system
59Supply and fixing Fire axe suitable for fire fighting system
60DIGITEL TEMP & HUMIDITY METER
61Supply, testing, commissioning and fixing of Temperature & Humidity Data Logger with the following specifications:- (a)Max / Min : Temperature reading over 0 to 100% RH :40 degree Celsius to 70 degree Celsius. (b)Measurement ranges by PC with USB interface with data card and LCD monitor (c)Memory for 32700 readings (16350 temperatures and 16350 humidity readings) with long life battery pack with accessories including locking arrangement complete with fixing on wall.
62ELECTRIC SIREN
63Supply, install, test and commission electric motor siren for heavy-duty application, ideal auidable range (Diametrical) 8.0 Kms, Motor 5 HP( 2880 RPM) insulation class F/B, IP-44 , 415 volts, 3 phase, frequency 50 Hz, aluminium casting bodied, horizontal impeller complete with all mounting and accessories including canopy made out of MS channel, CGI as required to protect from heavy rain fall complete all as specified and as directed.
64Supply and fix DOL starter suitable for electric motor upto 5 HP, 415 volts, 3 phase complete all as specified and as directed.
65DG SET
66Supply,installation,Testing and Commissio-ning silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc. of capacity 50 KVA.Technical Specification : Stroke- 4, No. Of cylinders- 4, RPM- 1500, Cyl. Configuration - vertical lnline, Dirction of Rotation - Counter clockwise viewed from flywheel end, Method of aspiration- Turbo charged after cooled, Method of cooling- Coolant cooled, Type of Governor- Electronic, Starting system-12V Electric start, Overload capacity- 10% for 1hr. in every 12hrs. running, Duty- Continuous, Safety control- Low lube oil pressure, High coolant temp, Applicable standards - ISO 3046,BS 5514, Bore & Stroke- 97x128mm, Displacement-3.84Ltrs, Compres-sion ratio-17.5 :1, Lube oil sump cap- 9 Ltrs, Coolant capacity with engine jacket- 15 Ltrs.
67Alternator. Rating: 50KVAType: Brushless, Excitation: Self excited, self regulated (AVR), Enclosure: SPDP, Enclosure protection: IP-23, Rating: Continuous, Rated voltage: 415V, No of phases: 3Ph, Rated current: 50KVA-208Amps,Frequency: 50Hz, Power factor: 0.8pf, Class of insulation: H, Voltage Regulation: + 1%, Overload capacity10% for 1hr for every 12hrs running, Applicable standards: IS 4722/BS 5000. Accessories. Fuel tank suitable for 8hrs. Capacity shall be supplied and to be mounted inside the canopy, Exide make batteries 1 No.x12V, 90AH capacity, Battery lead, Anti-Vibration mounting pads (fitted inside the canopy), Residential silencer (fitted on inside/top of canopy), First fill of lube oil & coolant.
68AMF Control Panel. The AMF control panel shall be made of 16SWG CRCA sheet, set/floor mounted, indoor type, dust and vermin proof and powder coated and suitable for 415V,3Phase, 50Hz system. The panel will be incorporated inside the canopy and shall consist of the following features: Microprocessor based AMF controller having safety features with display of following engine & Alternator parameters:- Engine Display features-Low lube oil pressure, High water temperature, overspeed, low fuel level, RPM, No. of hours run, battery voltage. Safeties- LLOP, HWT, LFL, Over Speed & earth fault relay. Alternator Display features- Ampere, Voltage, Frequency, Power Factor, Kw, Kwh, KVAR. Safeties- Over current, over/ under frequency, short circuit, current transformers of suitable ratio, 2 Nos suitalby rated 4 Pole power contactor for DG & Mains, 1 No. suitably rated MCCB with short circuit & overload protection as outgoing, Indicating Lamps for DG ON/ load ON/Mains ON, MCB for control protection, Battery charger with auto trickle & boost charging facility, Toggle switch for control ON/Off. Note: All engine & alternator parameters will be displayed through above controller only.
69Acoustic Enclosure. Acoustic enclosure should be FCRI approved and made of specially procured 16SWG CRCA sheet and structural sheet metal base frame and comply with CPCB /GRIHAnorms with following features:- The most compact, six sided, close, modular construction and detachable. Meet CPCB / MOEF norms. Sound level<75 DbA at one meter distance under free field conditions as per norms. Easy Accessibility around the DG set, which ensures optimum serviceability. Special powder coated enclosure, weather proof, corrosion resistant, environment friendly. Specially designed lifting hooks. Use of high quality hardware ensure longer life of enclosure. Provision for emergency stop facility. Fuel tank of 8hrs. running capacity is specially designed and mounted inside the enclosure as an integral part of Acoustic enclosure. Foundation /Plinth/Base : Shall be provided as per manufacturers recommendations included in quoted rate of contractor.Also necessary connection from main panel to DG panel with Cables as per load to be included in quoted rate of contractor. Note: RCC platform to mount DG Set shall be as per manufacturer recommendation and included in item rate.
70DEMOLITION & DISMANTLING
71Taking down DB/main switch of any size and making good disturbed surface of wall/floor complete all as specified.