Military Engineer Services-MES has published Tender For Certain Repairs Maintenance Of Street Lights High Mast Solar Lights And Connected Works At Mil Stn Bikaner Under Ge N Bikaner. Submission Date for this Tender is 18-11-2023. Solar Light Tenders in bikaner Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

40333251
Corrigendum : Tender For Certain Repairs Maintenance Of Street Lights High Mast Solar Lights And Connected Works At Mil Stn Bikaner Under Ge N Bikaner
Open Tender
Indian
Rajasthan
bikaner
18-11-2023

Tender Details

Certain Repairs Maintenance Of Street Lights High Mast Solar Lights And Connected Works At Mil Stn Bikaner Under Ge N Bikaner

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Oct-2023 Corrigendum BOQ 11-11-2023
2 11-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work: CERTAIN REPAIRS /MAINTENANCE OF STREET LIGHTS HIGH MAST, SOLAR LIGHTS AND CONNECTED WORKS ATMIL STN BIKANER UNDER GE (N) BIKANER.
Sl. No. Item Description
1Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth and getting out complete all as specified. (Taking out old brick from trenches shall be measured separately and deduction for brick shall be made on this account).
2Returning, filling in including spreading, leveling, watering and well ramming, in soft/loose soil, in layers not exc. 25 cmscomplete all as specified and directed.
3Removing surplus soil to a distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting pointcomplete all as specified and directed.
4Supply and laying un-reinforce precast concrete cable cover, class LV type-1 with peak, size 250 mmX150 mmx 40mm for protection of cablecomplete all as specified and directed.
5Local tibba dry sand cushioning and cover (8 cmthick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable)for protection of cable, material and labour complete all as specified and as directed by Engineer-in-Charge.
6Supply and laying in replacement of Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium stranded conductor, 1100 voltsLT grade of cross-sectionalarea 10 Sqmm 4 core laid in trenches/through pipein road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etcsupplied, fixed/ laid in repair including commissioning and testingcomplete all as specified and as directed by Engineer-in-Charge. (Note: :-(i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately.(ii) Road manually cutting/floor cutting/cutting holes etc in wall required for laying /fixing of cable etc shall be made good as per existing site condition. Nothing extra shall be admissibleon this accountand quoted rate for this item shall bedeemed to include for the same). Make- Havells/KEI/Polycab
7Ditto All as per Srl item No 6 here in above but size of cable 16 Sqmm 4 corecomplete all as specified and directed.
8Ditto All as per Srl item No 6 here in above but size of cable 16 Sqmm 2 corecomplete all as specified and directed.
9Ditto All as per Srl item No 6 here in above but size of cable 25 Sqmm 4 corecomplete all as specified and directed.
10Taking down carefully the defective street light fittings any kind any type from the poles/walls and refixing the same on poles/wallsafter repaircomplete all as directed by Engineer in Charge.( Note: A Team of workers for emergency are avlaibleinside the camp for 24 Hours)1. T&P i.e, ladder and vehicle will provided by the contractor.2. The contractor/his rep will collect the complaint from JE every day 9.00 hrs , the same will be rectified before sunset on same day,If the contractor fail to rectify the defect mentioned in the complaint slip on same day, he will be charged Rs 100/per complaint and same will be recovered from the contract amount. NOTE:- VMTL with driver will be provided by the AGE E/M for repair of doubleswan neck pole"s and single swwan neck poles security lights only.
11Supply and fixing in replacement outdoor Driver unit25 watt with surge protection complete all as specified and directed. Make - CG/Philips/Wipro
12Supply and fixing in replacement outdoor Driver unit40 watt with surge protection complete all as specified and directed. Make - CG/Philips/Wipro
13Supply and fixing in replacement outdoor Driver unit45 watt with surge protection complete all as specified and directed. Make - CG/Philips/Wipro
14Supply and fixing in replacement outdoor Driver unit75 watt with surge protection complete all as specified and directed. Make - CG/Philips/Wipro
15Supply and fixing in replacement outdoor Driver unit90 watt with surge protection complete all as specified and directed. Make - CG/Philips/Wipro
16Supply and fixing in replacement outdoor Driver unit150 watt with surge protection. complete all as specified and directed. Make - CG/Philips/Wipro
17Supply and fixing in replacement surge protection devices 5 KV compatible with industrial and outdoor LED fixtures upto rated power of 75 Wattcomplete all as specified and directed.Make - CG/Philips/Wipro
18Supply and fixing in replacement surge protection devices 5 KV compatible with industrial and outdoor LED fixtures with rated power above 75 Watt and upto 150 Watt complete all as specified and directed. Make - CG/Philips/Wipro
19Taking down existing high mast head frame for dismantling the unserviceable parts including repair of control panel wiring incl testing complete all as specified and directed. ( NoteMaking suitable arrangements of ladder or crane or scaffoldingis the responsibility of contractor .
20Taking down and dismantling existing high mast pole of high 12 to 21 mtrs from bottom plate, nuts and bolts complete with the help of suitable T&P required for holding, lifting and dismantaling high mast pole, replacement of unserviceable part ,oiling and greasing of pulleys, gear box, rope and all moving parts including assembling, intallation of high mast pole complete as directed by Engineer in Charge. ( Note. 1. Cost of crane for dismantling high mast pole is deemed to be included in quoted rate. 2. Cost of oiling and greasing of moving parts in deemed to be included in rate quoted.
21S&F TPN MCB "C" Curvecapacity 40 Amps 10 KA.complete all as specified and directed.
22Taking downby disconncting the existing electrical connections of winch motor for rewinding / repairs includingRewinding the motor of capacity up to 2 HP with best class supper enameled copper wire of existing gaugeand size including varnishes and insulating 230 V AC Hz electricsupply system . refixing and reconnecting it to the originallocation for satisfactory functioning of winch on230 V electric supply system all as specified
23Supply and fixing in replacement steel wire rope of 10 mm sizeand capacity all as specified
24Taking down the existing winch gear box of hight mast light 12 to 21 mtrs by disconnecting the winch motor and supply in replacement the winch gear box of appropriate capacity as per sample and make , fixing and connecting the same with winch motor for satisfactory operation of winch on electrical power all as specified
25M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-410-0 or Fe-310-0 grade including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces after preparation of surfaces, suppliedand fixed in repair complete all as specified and as directed by Engineer-in-Charge. (Note: - (i) Sizes & types of members and shape of the cross arms etc shall be as required at site all as directed by the Engineer-in-Charge.(ii) Un-exposed steel surfaces shall be given one coat of red-oxide zinc chromate primer only.Cost of the same is included in unit rate of the item and nothing extra shall be paid on this account.)
26Supply and fixing Street light bracket in replacement, made of GI pipe 40mm bore, light grade not less than 1 m long bent to shape includingfixing with2 nos suitable size of MS flat iron 40x6 mm clamps, nuts, bolts and washers and making connections all as directed by the Engineer-in-Charge.
27Supply and fixing in replacement for Multistranded three core PVC insulated FRLSH copper conductor cable ofsize 2.5 sqmm (nominal area), & drawing into hollow street light pole from fitting to distribution box or fitting to over head line all as specified including taking out old existing unserviceable cable. complete all as specified and directed.
28Supply and fixing in replacement for two core PVC insulated weather proof cable with aluminum conductor size 4 sqmm (nominal area), & drawing into hollow street light pole from fitting to distribution box or fitting to over head line all as specified including taking out old existing unserviceable cable.complete all as specified and directed.
29Ditto all as per Srl Iem No 28 here in before but size of cable6 Sqmm 2 core complete all as specified and directed.
30Ditto all as per Srl Iem No 28 here in before but size of cable 10 Sqmm 2 core complete all as specified and directed.
31Taking out old LT underground cable and laying after removing of defects any type/size laid in trenches/through pipein road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc including commissioning and testingcomplete all as specified and as directed by Engineer-in-Charge.
32Boring of holes under road, pavement, hard standingby trench manuallycomplete all as specified and as directed by the Engineer-in-Charge.
33Tightening GI tube bracket of street lights mounted on poles including realigning to the centre of roads including replacement of necessary nuts, bolts & washers wherever required to be replacedall as directed
34Testing and checking of faulty street light feederincluding under ground cable or on the pole on line etc and repair the same after remove the faulty feeder complete testing all as directed by Engineer in Charge Note :- Earth work measured and paid separately.
35Taking down Unserviceable time switch , checking/ testing Time switch by disconnecting the connectionand refixing the same after minor repair/resettingall as directed by Engineer in Charge Note:- item required for repairing of timer switch will measured and pain seperately under appropriate schedule of item.
36S & F MCB SP, 63 Amps , 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge.
37S & F MCB4 pole , 63 Amps , 415 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge.
38Supply only Panel mounted 2 Pole contactor MNX-22-2P of suitable rating operational voltage 230 volts confirming to IS/IEC60947-4-1, AC 50 HZ, inbuilt aux. contacts- 1 No+01 NCwith standard coil voltage 220 volts the surge resistor contract shall be post break type and damping resistances after closing be cut of current rating cap 22 Amp. complete all as specified and directed. Make :L&T/C&S/Havells
39Supply only Panel mounted 2 Pole contactor MNX-40-2P of suitable rating operational voltage 230 volts confirming to IS/IEC60947-4-1, AC 50 HZ, inbuilt aux. contacts- 1 No+01 NCwith standard coil voltage 220 volts the surge resistor contract shall be post break type and damping resistances after closing be cut of current rating cap 22 Amp complete all as specified and directed. Make :L&T/C&S/Havells
40Supply only nature switch designed forautomatic control of outdoor lighting, using infrared sensing based nature switches compatible for both single & three phases supply with operating voltage range 120-440 Volts for a nominal 230 Volts system.complete all as specified and directed by engr-in-charge.
41Material and Labour for repairing of MS street light junction box, tighting of loose nut, bolts, screws etcincluding cutting of burnt thimbles/ LT cable, taking out LT cable from Loop andrecconecting to bus bar with new thimbles duly crimpped with cable complete all as directed and specified by Eng-in-charge.
42Trimming /pruning of the tree branches coming around the street light fittings and making the street light free from touching the tree branches not less the 4 mtr radius complete all as specified and directed.
43Supply & fixing in replacement of LED decorative post top lantern light fittings for 360 degree indirect light with IP 65 protection, resistant to impact and corrosion, glare free and better uniformity complete all as specified and directed.Make CG Model LPTO-40-CDL or equivalent MakePhilips /Bajaj
44Supply & fixing in replacement of LED post top lantern light fittings with IP 65 protection, ideal to lit up parks, garden ways etc complete all as specified and directed.Make CG Model LPTH-20-CDL or equivalent MakePhilips /Bajaj
45Suppy and Fixing LED based street light, housing made up of LM6 pressure die cast aluminium alloy with aerodynamically designed for all weather conditions with excellentthermal management, toughned glass and high power LED"s with seconday optics and IP66 protection, sturdiness. The fixture should have a minimum system efficiency of more than 110/120lumen/watt and a minimum system lumen output of not less than 7700 lumens and maximum system wattage 70 Watts. The fixture shall have a correlated colour temperature of al least 5700K and CRIminimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical inpact resistance raiting of IK>=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation, driver should be withstand up to 440v for 8hrs, two surge proection, 4KV one on driver and one 10 KVexternal surge protection, PF>0.95 and THD<10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C.
46The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3,2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory. Make CG Catpart No.CRP-409-70-57-SL-GL-NSG or equivalent make of Philips/Wipro NOTES FOR LED LIGHT FITTINGS : For item No. 45 to 50. (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries. (v) Driver of the fittings must be potted type only and both fixture and driver must have seprate BIS marked resistration with clearly mentioned on fixture as well as on driver. (iv) CA No. shall be marked on each LED light fittings by printing mechanism as directed by engr-in-charge and rate of the same is deemed to be included in above quoted rate.
47Suppy and Fixing LED based street light, housing made up of LM6 pressure die cast aluminium alloy with aerodynamically designed for all weather conditions with excellentthermal management, toughned glass and high power LED"s with seconday optics and IP66 protection, sturdiness. The fixture should have a minimum system efficiency of more than 110/120lumen/watt and a minimum system lumen output of not less than 6600 lumens and maximum system wattage 60 Watts. The fixture shall have a correlated colour temperature of al least 5700K and CRIminimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical inpact resistance raiting of IK>=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation, driver should be withstand up to 440v for 8hrs, two surge proection, one 4KV on driver internaland one 10 KVexternal surge protection, PF>0.95 and THD<10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3,2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory. Make CG Catpart No.CRP-409-60-57-SL-GL-NSG or equivalent make of Philips/Wipro
48Suppy and Fixing LED based street light, housing made up of LM6 pressure die cast aluminium alloy with aerodynamically designed for all weather conditions with excellentthermal management, toughned glass and high power LED"s with seconday optics and IP66 protection, sturdiness. The fixture should have a minimum system efficiency of more than 110/120lumen/watt and a minimum system lumen output of not less than 4950 lumens and maximum system wattage 45 Watts. The fixture shall have a correlated colour temperature of al least 5700K and CRI f minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical inpact resistance raiting of IK>=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation, driver should be withstand up to 440v for 8hrs, two surge proection, 4KV one on driver and one 10 KVexternal surge protection, PF>0.95 and THD<10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3,2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory. Make CG Catpart No.CRP-409-45-57-SL-GL-NSG or equivalent make of Philips/Wipro
49Suppy and Fixing LED based street light, housing made up of LM6 pressure die cast aluminium alloy with aerodynamically designed for all weather conditions with excellentthermal management, toughned glass and high power LED"s with seconday optics and IP66 protection, sturdiness. The fixture should have a minimum system efficiency of more than 125/135lumen/watt and a minimum system lumen output of not less than 22500 lumens and maximum system wattage 180 Watts. The fixture shall have a correlated colour temperature of al least 5700K and CRI f minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical inpact resistance raiting of IK>=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation, driver should be withstand up to 440v for 8hrs, two surge proection, 4KV one on driver and one 10 KVexternal surge protection, PF>0.95 and THD<10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3,2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory. Make CG Catpart No.CRP-418-180-57-HL2-GL-HR-NSR or equivalent make of Philips/Wipro
50Suppy and Fixing LED based Floodlight, housing made up of LM6 pressure die cast aluminium alloy with aerodynamically designed for all weather conditions with excellentthermal management, toughned glass and high power LED"s with seconday optics and IP66 protection, sturdiness. The fixture should have a minimum system efficiency of more than 110/120lumen/watt and a minimum system lumen output of not less than 22000 lumens and maximum system wattage 200 Watts. The fixture shall have a correlated colour temperature of al least 5700K and CRI f minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical inpact resistance raiting of IK>=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation, driver should be withstand up to 440v for 8hrs, two surge proection, 4KV one on driver and one 10 KVexternal surge protection, PF>0.95 and THD<10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3,2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory. Make CG Catpart NoCFS-501-200-57-60D-SL-GL-NGG or equivalent make of Philips/Wipro
51Supply & Fixing of LED based Flood light fitting, housing made up of pressure die cast aluminum Alloy with effective thermal management, sturdiness . The fixture should have a minimum system efficacy of more than 110 lumen/Watt and a minimum system lumen output ofnot less than 8800 lumens and maximum system wattage 80 Watts. The fixture shall have a corelated color temperature of at least 5000K and a CRI of minimum 70 .The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment and Mechanical Impact Resistance Rating of IK >=05. The fixture driver should be withstand up to 440v for 8hrs, two surge proection not less than 5KV one on driver and one external surge protection, PF >0.95 and THD<20% .The fixture should comply with the parameters as per IS10322 and for EMI and LM 79testreports .Including suitable size street light fitting bracket with suitable sizeclamps,nut bolts and washers as per site requirement complete all as specified as directed by Engineer-in-Charge. make CG Catpart No.LFL-80-CDL/60-M or equivalent make of Philips/Wipro
52Preparation of old painted surface and painting of steel Tubular street light pole 12 mtr height double swan neck upto 1.5m above the top of PCC coping with 2 coats of aluminium anti corrosive paints of first quality and painting to pole upto 1.5m height fromtop of PCC coping with synthetic enamel paint 2 coat in black and white alternate strip including numbering in 8 cm height of number with white paint both paint aluminium/synthetic duly approved by Engineer in Charge complete as directed and specified.
53Supplying and fixing of automatic street light switch using infrared sensor based Nture Switch-, 25 kw equally distributed,63 Amps,3-pole,Model - Swadeep-02 EC 25 Kw3Pfor automatic switching of street lights based on LUX level of natural light . The sensor(Nature switch ) along with suitable power contactorrating 63 Amps 3- pole & 40 Amps 2-pole, MCB SP 63 Amps -03 nosand support terminals should be enclosed in pole/wall mountable enclosure made of rust proof ,electric shock proof, termite proof and FR grade SMC Junction box (Sintex make) confirming to IP54.The contactor suitable to 3- phaseload of 25 kw , rating 63 amps 3pole, MCB rating 63 amps SP 03 NOS. Make of Nature switch-Kakatiya Energy systems Pvt Ltd.Hyderbad/ Bajaj/Healer.Contactor-BCH/L&T/Schneider (asper IEC-60947-4-1/IS-13947-4-1),MCB- Hager/ Schneider/ Legrand/L&T, Circuit Wiring-Polycab/RR Cable /Finolex.
54Supplying and fixing of automatic street light switch using infrared sensor based Nture Switch, 08 kw equally distributed,63 Amps,1-pole,Model - Swadeep-02 EC 8 Kw1Pfor automatic switching of street lights based on LUX level of natural light . The sensor(Nature switch ) along with suitable power contactorrating 63 Amps 2- pole & 40 Amps 2-pole, MCB SP 63 Amps -02 nosand support terminals should be enclosed in pole/wall mountable enclosure made of rust proof ,electric shock proof, termite proof and FR grade SMC Junction box (Sintex make) confirming to IP54.The contactor suitable to 1- phaseload of 08 kw , rating 63 amps 2 pole, MCB rating 63 amps SP 01 NOS. Make of Nature switch-Kakatiya Energy systems Pvt Ltd.Hyderbad/ Bajaj/Healer.Contactor-BCH/L&T/Schneider (asper IEC-60947-4-1/IS-13947-4-1),MCB- Hager/ Schneider/ Legrand/L&T, Circuit Wiring-Polycab/RR Cable /Finolex.
55S & F Junction Box of size(H X W X D) 300x200x105 mm made out of Polycarbonate material totally enclosed, dust and vermin proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 55 with integrated membranes/metric knockouts for cable entry with cable glands,protection and suitable size of "connectwell" stud teriminal (provision for socket bolting)- 04 Nos suitable for 415 volts, 50 Hz, 3 phase 4 wire internal wiring system including MCB SP 06 amps- 01 No and mounted on tubular/PCC pole with suitableclamps, nuts, bolts including removal of exiting unsv all as specified and directed. Note :- CA No. shall be Marked on each box by digital printing mechanism.
56Supply and fixing in replacement PVC insulated Copper Tailing cable 6 core 2.5 sqmm of suitable for installation on high mast complete all as specified and as directed by the Engineer-in-Charge.
57Demolition of cement concrete (un-reinforced) in ground floors and pavings n.exc 15 cm thickness (below or above GL) complete all as specified and as directed by the Engineer-in-Charge.
58Supplyand fixing in replacement GI pipe light grade 40 mm bore (ISI marked) laid in trenches/ road crossings/ fixed to poles/ceiling / along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specifiedand as directed by the Engineer-in-Charge.
59Plain cement concrete (1:3:6) type C-2 using 20mm graded stone aggregates as in foundation for stay and copping of pole above ground levelincludingfinishing to exposed concrete surfaces even and fair and provision of form work for rough finished surfaces complete all as specified and as directed by Engineer-in-Charge.
60Supply and fixing LED strip with driver capacity of 28 W for 5 mtr length having system voltage 220-240V 50HZ, color temperature 6500K, dimensio of 5000X8X2 mm complete all as specified and directed by engr-in charge,.