Tender For Repairs / Replacement Of Lt Cable, Lt Panels, Apfc Panels, And Other Allied Works Of Eastern Area At Hisar Mil Stn Under Ge Hisar, hisar-Haryana

Military Engineer Services-MES has published Tender For Repairs / Replacement Of Lt Cable, Lt Panels, Apfc Panels, And Other Allied Works Of Eastern Area At Hisar Mil Stn Under Ge Hisar. Submission Date for this Tender is 20-11-2023. Electrification Work Tenders in hisar Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

40332995
Corrigendum : Tender For Repairs / Replacement Of Lt Cable, Lt Panels, Apfc Panels, And Other Allied Works Of Eastern Area At Hisar Mil Stn Under Ge Hisar
Open Tender
Indian
Haryana
hisar
20-11-2023

Tender Details

Tender For Repairs / Replacement Of Lt Cable, Lt Panels, Apfc Panels, And Other Allied Works Of Eastern Area At Hisar Mil Stn Under Ge Hisar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work : REPAIRS / REPLACEMENT OF LT CABLE, LT PANELS, APFC PANELS, AND OTHER ALLIED WORKS OF EASTERN AREA AT HISAR MIL STN UNDER GE HISAR
Sl. No. Item Description
1Taking out the old unserviceable LT underground cable 10 sqmm 2 core 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors from trenches/wall/floor/road/ culverts or pole etc complete all as specified and directed . Note : Excavation and earth work, duct work, GI pipe for laying of cable and sand cushing/cable protection covers etc are beyond the scope of this item and shall be measured & paid for separately under relevant items of BoQ.
2All as per item No 1.00 (here-in-before) but 35Sqmm 3.5 core.
3All as per item No 1.00 (here-in-before) but 70Sqmm 3.5 core.
4All as per item No 1.00 (here-in-before) but 120Sqmm 3.5 core.
5All as per item No 1.00 (here-in-before) but 185Sqmm 3.5 core.
6All as per item No 1.00 (here-in-before) but 240Sqmm 3.5 core.
7Laying only old serviceable LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductorsin trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe of10 Sqmm 2 core all as directedretrieved from item srl No. 1.00 (here-in-before).
8Laying only old serviceable LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductorsin trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe of35 Sqmm 3.5 core all as directedretrieved from item srl No. 2.00 (here-in-before).
9Laying only old serviceable LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductorsin trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe of70 Sqmm 3.5 core all as directedretrieved from item srl No. 3.00 (here-in-before).
10Supply , laying,jointing, testing and commissioningof size 10 sqmm 2 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
11All as per item No 10.00 (here-in-before) but 35Sqmm 3.5 core.
12All as per item No 10.00 (here-in-before) but 70Sqmm 3.5 core.
13All as per item No 10.00 (here-in-before) but 120Sqmm 3.5 core.
14All as per item No 10.00 (here-in-before) but 185Sqmm 3.5 core.
15All as per item No 10.00 (here-in-before) but 240Sqmm 3.5 core.
16Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depthfor laying cables, foundation for pole etcand getting out in soft/loose soil etc complete all as specified and as directed.
17All as per Serial item No 16.00 (here-in-before) but depth exceeding 1.5 mtr and not exceeding 3.00 mtr.
18Removing excavated material to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point etc complete all as specified and as directed. .
19Returning filling in incl spreading leveling watering and well ramming in layers n. exc 25cm thick etc complete all as specified and as directed.
20M&L for Sand cushioning 230mm thickness withdry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) andpunned down to 180mm after laying of cablein trenches for protection of cable completeall as directed. Note :- For the purpose of payment only punned thickness shall be measured.
21Taking up bricks laid as cable covers and stacking serviceable brick for reuse at site etc complete all as specified and directed.
22Laying only old bricks retrieved from item Srl Item No. 21.00 (here-in-before) as cable covers in trenches etc complete all as specified and directed.
23M&L for brick covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, perpendicular to the direction of cable etc complete all as specified and directed. .
24Taking up or down 40mm bore steel tubing and connection incl cleaning for refixing or removal to store all as specified & directed.
25Taking up or down 80mm bore steel tubing and connection incl cleaning for refixing or removal to store all as specified & directed.
26Fixing only 40mm bore steel tubes light grade including fittings on poles/ walls/under Road / floor all as directedretrieved from item srl No. 24.00 (here-in-before). Note :- Necessary clamps, nut, bolts, washers etc shall be deemed to be included in rates quoted.
27Fixing only 80mm bore steel tubes light grade including fittings on poles/ walls/under Road / floor all as directedretrieved from item srl No. 25.00 (here-in-before). Note :- Necessary clamps, nut, bolts, washers etc shall be deemed to be included in rates quoted.
28M&L for Galvanized iron tubing, 40mm bore light grade, ISImarked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
29M&L for Galvanized iron tubing, 80mm bore light grade, ISImarked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
30S&F in replacement MCB TPN of capacity 63A,10 KA, type "B", 415 volts complete all as specified and directed
31Supply, installation, commissioning and testing in replacement of MCCB 630 Amp ( fixed on existing panel) 415 volt, 4 pole, 50 KA breaking capacity with adjustable current range for overload protection and thermal release complete with spreader terminals (legs) and with proper lugs complete all as specified and as directed.
32All as per Srl item No "31.00" (here-in-before) but 400 Amps, 36 KA.
33All as per Srl item No "31.00" (here-in-before) but 200 Amps, 36 KA.
34All as per Srl item No "31.00" (here-in-before) but 63 Amps, 27 KA.
35Disconnecting and taking out underground cable, including carry out megger testing of dismantle LT cable of 3.5/4core 25 to 50 Sqmmsizes oflength not more than 5 mtr and locating the fault and cutting the faulty damaged portion of cable , connecting with providing new heat shrinkable straight through jointing kit with suitable size , including excavation, returning fillingand all connected materials complete all as specified and directed. Note:-Necessary excavation , sand cushioning ,cable cover as bricks etc beyond 5 mtr should be measured and paid separately.
36All as per Srl item No "35.00" (here-in-before) but 3.5core 70 to 150 Sqmm
37All as per Srl item No "35.00" (here-in-before) but3.5core 185 to 240 Sqmm
38All as per Srl item No "35.00" (here-in-before) but 3.5core 300 to 400 Sqmm
39Testing and fault locating of LT underground cable of any size with the help of cable fault locating machine at site including removal of moisture content from cable all as directed. Notes :- (i) The machine for locating of fault will be arranged by the contractor and quoted rates is deemed included the same inclduing cost of necessary excavation &earthwork. (ii) Cable joint will be measured & paid seperately under relevant item
40S&F 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire,cable flat or circular of aluminium solid conductors of size 16 Sqmm twin core including taking down existing service connection all as specified & directed.
41Dismantling unserviceable concrete pole/struts of any size and removing from site complete all as specified and directed.
42Supply, erecting & fixing in true vertical position pre stressed concrete pole conforming to IS-1678 of9 mtr long, 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class 10 complete all as specified and directed by Engineer- in-charge. Note :- (i) The rate quoted shall deemed to included taking out conductors, earthwire from existing pole and refixing to newly errected pole. (ii) Earth work & PCC shall be measured and paid separately.
43Dismantling unserviceable stay assemblycomplete and removing from site complete all as specified and directed by Engineer- in-charge.
44M&L for GI Stay assembly with 20mm dia of stay rod complete with all accessories as shown in electric plate no 1 of MES schedule Part I complete. Note: - Earth work, PCC, loop type insulator shall be measured separately.
45S&F in replacement galvanized stay stranded wire of size 7/4 mm and fixing to stay assembly complete all as shown in electrical plate No 1 of SSR-2009 (Part-I) complete all as specified and directed.
46M&L for plain cement concrete (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation complete all as specified and directed.
47M&L for PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) as in mass concrete including necessary form work complete all as specified and directed.
48M&L for PCC (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles complete all as specified and directed.
49Dismantling unserviceable cross arms, clamps etc and removing from site complete all as specified and directed.
50M&L for Cross Arms bracings supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps stay clamps, D clamps nuts, bolts, washers welding bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat ofaluminiumpaint complete all as specified and directed.
51Dismantling insulator any type/ any size from LT poles complete all as specified and directed by.
52S&F loop type insulator, vitreous porcelain, white brown or green with over all dimensions 65mm x 90 mm, clearance of hole 16 mm suitable for 1100 volts complete all as specified and directed by Engineer- in-charge..
53S&F pin type insulators LT 1100 Volts grade porcelain vitreous white or brown including one galvanized mild steel spindle, two galvanized iron washers, one galvanised iron nut, 100 mm height, 65 mm diaall as specified and directed.
54M&L for providing shackle type insulator LT 1100 volt grade porcelain vitreous white or brown including galvanised insulator bolts, nuts 12 mm dia and washer including 31x3mm galvanised mild steel straps, 75 mm height and 90 mm dia of insulator complete all as specified and directed.
55Taking down unserviceable/old ACSR conductor any size from over head lines, poles by removing binding wire, service wire, cables and removal from site complete all as specified and directed.
56Supply and fixing Aluminium conductor steel reinforced (ACSR) of any size for HT/LT OH lines on poles including stringing ,binding with aluminium wire 14 SWG or aluminium tape incljumpers complete connecting of disconnected cable, service cable and street light connection complete all as specified anddirected.
57Re-Stringing / Re-stretchingincluding jointing in situ of each span not more than 45 Mtrs between two electric poleshaving 5 Nos of ACSR conductorsincluding GI earth continuity wire, with/ withoutguarding wires onelectric poles of any size at different locations all as ordered manually or by telephonically means to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete as ordered :-
58Prunning / trimming the branches of trees if any along overhead line with any number of conductor, 3 mtr on all side below/ above/ sides of overhead line and removing the same upto 150 mtr away complete all as specified and directed by Engineer-in-Charge (The above is to be ensured for the entire contract period by cutting/trimming of trees any number of times as required). Note :- Trimming of tree branches shall be carried out for any number of conductors in a span surrounded by tree branches.
59M&L in replacement of PVC separator in position to keep ACSR conductor as equal spacing complete all as specified and directed by Engineer-in-Charge suitable for 3 Wireof ACSR conductors
60All as per Srl item No "59.00" (here-in-before) but 5 Wire
61M&L for Boring of holes under road, pavement hard standing by trenchless technology using necessary mechanical mean for laying of cable complete all as specified and directed.
62M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers,PCCchamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete including taking down existing u/s earthing all as specified & as directed. Note :- PCC chamber shall be constructed at least 1.5m away from the earthelectrode and pipe for watering shall be provided in slanting manners.
63All as per srl item No "62.00" (here-in-before) but using galvanized iron strip 25 x 4 mm as earthing lead and GI protection pipe light grade 40 mm bore. NOTEfor Srl item no 62.00 & 63.00 :- The unit rate quoted shall includes for protection pipe and GI earth wire 4.00mm /GI strip25x4mm from top of earth plate up to 7.5 meter above ground level.
64Supply and fixing in replacement Indicator lamp LED type (R-Y-B) 240 V, AC, Single phase, fixed on existing LT panel all as specified and directed.
65Supply and fixing in replacement digital type Volt meter 96mm x 96mm of range 0-500 Volts, Class - 1 incl internal wiring with 1.00 sqmm single core copper cable all as specified and directed.
66Supply and fixing in replacement digital type Ammeter 96mm x 96mm of range 0-600 Volts, Class - 1 incl internal wiring with 1.00 sqmm single core copper cable all as specified and directed.
67M&L for preparation of old surface of existing panel of size not more than 1.2 m x 0.75 m x 1.2 mtr mounted on angle iron frame not more than 30 cms height by scratching and complete removing of existing paint and M & L for spray painting the existing panel outside and inside of approved shade with two coats of synthetic enamel paintcomplete all as specified and as directed.
68M & L for repairing of existing LT panel by welding, replacing of 03 Nos of broken hinges as per existing shape & size complete all as specified and as directed.
69M & L in replacement for LT Danger notice plate of size 20 X 15 cm of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures, and conventional skull and bones, in signal red colour and fixed with MS clamps, bolts, and nuts of approved size etc complete all as specified and as directed.
70Surface dressing not exceeding 15 cm depth and getting out in soft /loose soil including clearing away all grass and vegetation saplings , shrubs , bushes , undergrowth roots and removing rubbish upto a distance n exc 50 mtrs outside the periphery of the any installation/ feeder pillar area etc. Note:-The contractor will ensure that no vegetation grows during the contract period on the area so dressed.
71Material & Labourfor painting of steel tubularpoles of any height includingcross arms, clamps, back plates etc by rubbing with sand paper and cleaning incl preparation of old surfaces and applying two coats of aluminum paint including making 03 Nos of 30cm wide circular bands with black and yellow paint starting from plinth level at a gap of 30cm in between 2 bands and numbering of poles in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5cm large block letters 2" (inch) wide complete all as specified and directed.
72Supply, installation, commissioning and testing of LT panel box (Kiosk), out door type, platform mounted, suitable for 415 Volts, 50 Hz , 3 phase, 4 wire supply, CPRI approved, factory assembled, having bus bar chamber with insulated Aluminium bus bar 240 Amps rating installed on porcelain insulators, the panel shall be dust and vermin proof double door made out of 3.15mm CRCA MS sheet, outer & inner and individual compartment for MCCB / MCB & Volt meter / Ammmeter and 50 x50 x 6mm thick angle iron for base frame work, LT panel box should be powder coated including internal wiring with PVC insulated solid copper conductor FRLS cable of appropriate sizes but not less than 4 sqmm, front opening type with approx for cable enty with double door shutter including locking arrangement as per manufacturers with 2 keys complete including and comprising of the following complete all as specified and directed including taking down existing u/s LT panel :-(a) Incoming :- (i)MCCB 4 pole , LT 415 Volts, 50 Hz, AC, 160 Amps rating with 36 KArupturing capacity, thermal & magnetic release adjustable type ( Ics =100%Icu).-01 No. (ii)Bus bar Aluminium TPN 240 Amps - 01 Set Note:-(i)All incoming /outgoing cables shall be connected throughsuitable size gland plate/glands and these will be connected with Al Lugs of suitable size also( if necessary). (ii)The size of gland plates should be of suitable capacity of cable. (iii)The Rate quoted shall deemed to be included necessary internal wiring with copper conductor of suitable size as per manufacturer requirement.
73Supply, installation, commissioning and testing of factory made, out door type, self standing, double door, front and back openable, made of 3.15mm CRCAMS sheet APFC panel compartmental type with APFC relay 8 stage with heavy duty MPP capacitor bank 120 KVAR (5 KVAr - 03 No, 10 KVAr - 03 No, 25 KVAr - 01 No, 50 KVAr - 01 No with 7% detuned harmonics filter reactor) with thyrister control module and MCCB TP of 16 KA of 1.5 times of rating currect of capacitor suitable for each control and MCCB TPN 250 Amps 36 KA as incomer including control CT & control wiring complete having following assessories including control wiring with HR FRLS copper wire complete all as specified and directed including taking down existing u/s panel :-Notes :- (i)Compact modular bolted design, removable side and back panels with option of top and bottom cable entry. (ii)Capacitor installed in removable assemblies for ease of operation and maintenance. (iii) Incoming of APFC panel of MCCB TPN 250 Amps, 36 KA breaking capacity with high electrolytic grade Aluminium bus bar of suitable rating. (iv)120 KVAR (5 KVAr - 03 No, 10 KVAr - 03 No, 25 KVAr - 01 No, 50 KVAr - 01 No) with thyrister control module and MCCB TP of 16 KA of 1.5 times of rating current of each capacitor suitable for each control (each capacitor bank equipped with discharge resister) & 7% detuned harmonics filter reactor.(v)High performance microprocessor based 3 Phase APFC relay 8 stage with Auto / Manual option. (vi)In built 3 Phase power analyzer, Ammeter, Voltmeter and PF meter (each have 01 No) (vii)Capacitor duty thyrister control modules with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitors. (viii) Induced air system provided with axial flow fan / centrifugal fan. (ix) Bottom cable entry system available with front glass for viewing controller and analyzer from front.