Tender For Spl Repair Of Walls Of Burning Pit, Refixing Of Iron Plated, Electric Fitments And Electricity Supply Of Amn Sub Depot, Provn Of 01 X Wpn Burning Pit At Shed No Nh-160 (Rssd) And Other Sanctioned Works Of Cod Under Age B/R-Ii Of Ge (East), jabalpur-Madhya Pradesh

Military Engineer Services-MES has published Tender For Spl Repair Of Walls Of Burning Pit, Refixing Of Iron Plated, Electric Fitments And Electricity Supply Of Amn Sub Depot, Provn Of 01 X Wpn Burning Pit At Shed No Nh-160 (Rssd) And Other Sanctioned Works Of Cod Under Age B/R-Ii Of Ge (East). Submission Date for this Tender is 15-11-2023. Wall construction Tenders in jabalpur Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40332907
Corrigendum : Tender For Spl Repair Of Walls Of Burning Pit, Refixing Of Iron Plated, Electric Fitments And Electricity Supply Of Amn Sub Depot, Provn Of 01 X Wpn Burning Pit At Shed No Nh-160 (Rssd) And Other Sanctioned Works Of Cod Under Age B/R-Ii Of Ge (East)
Open Tender
Indian
Madhya Pradesh
jabalpur
15-11-2023

Tender Details

Spl Repair Of Walls Of Burning Pit, Refixing Of Iron Plated, Electric Fitments And Electricity Supply Of Amn Sub Depot, Provn Of 01 X Wpn Burning Pit At Shed No Nh-160 ( Rssd ) And Other Sanctioned Works Of Cod Under Age B / R-Ii Of Ge ( East ) Jabalpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 86000.0 /-
Tender Value
INR 42.96 Lakhs /-

BOQ Items

Name of Work : SPL REPAIR OF WALLS OF BURNING PIT, REFIXING OF IRON PLATED, ELECTRIC FITMENTS AND ELECTRICITY SUPPLY OF AMN SUB DEPOT, PROVN OF 01 X WPN BURNING PIT AT SHED NO NH-160 (RSSD) AND OTHER SANCTIONED WORKS OF COD UNDER AGE B/R-II OF GE (EAST) JABALPUR
Sl. No. Item Description
1RESTRICTED AREA SCHEDULE
2Excavating over areas n.exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
3Excavation in trenchesfor laying of cables, poles and stay in any type of soil n.exc 1.5 mtr wide and n.exc 1.50 mtr deep and getting outin soft/loose soil complete all as specified and directed.
4Returning & filling in, including spreading and leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
5Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in & raming earth/ broken rubble mixed with earth around, in layers n.exc 25cm, watering & removing surplus soil to a distance n.exc 50m & making good surface in soft/loose soil complete all as specified and directed.
6M&L for unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deepbefore laying and 15 cm covering above the top edge of cable after laying complete all as specified and directed. Note : Maesurement shall be done after puning down of sand.
7Removing excavated materials n.exc 50 mtr and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
8Removing excavated soil exc 50m but n.exc 100m & depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
9M&L for Moorumm/red bajri filling in floors or pavings, laid in layers n.exc 15 cm thick spread, levelled & rammed including watering complete all as specified and directed.
10M&L for hard core, broken stone or gauge n.exc 63mm complete all as specified and directed.
11M&L PCC in foundations, filling and mass concrete type C-2 (1:3:6) using 40 mm graded crushed stone aggregate complete all as specified and directed.
12M&L PCC in foundations, filling and mass-concrete type D-2 (1:4:8) using 40 mm graded crushed stone aggregate complete all as specified and directed.
13M&L for PCC (1:2:4) type B-2 using 40mm graded crushed stone aggregate as in filling in surface channels and drains etc complete all as specified and directed.
14M&L PCC in roof kerbs of mud stops, paddingtype B-1 (1:2:4) using 12.5 mm graded crushed stone aggregate complete all as specified and directed.
15M&L PCC in lintels upto 1.5 m clear span, cills, steps, seismic & other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating as directed type B-1 (1:2:4) using 20 mm graded crushed stone aggregate complete all as specified and directed.
16M&L RCC type B-1 (1:2:4) using 20 mm graded crushed stone aggregate in Walls, retaining walls, basement walls, ballast walls and the like, any thickness, above top of footings, including attached pilasters and buttresses complete all as specified and directed.
17M&L RCC M-25 design mix using 20 mm graded crushed stone aggregate in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc basement slabs, under reamed piles and mass concrete complete all as specified and directed.
18M&L RCC M-25 design mix using 20 mm graded crushed stone aggregate in columns, pillars, piers, posts and struts complete all as specified and directed.
19M&L for Fly Ash bricks sub-class "B" locally available laid flat in trenches over sand cushioning for cable protection complete all as speciffied and directed.
20M&L for Brick work with sub class `B" bricks, straight or curved on plan exc 6m mean radius, built in lime mortar (1:4) complete all as specified and directed.
21M&L for fire brick work in linings to fire places, flues, burning pit etc (other than in chimney shafts), set, jointed and pointed in fireclay mortar complete all as specified and directed.
22Form work to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams, and similar work, verticle or to batter rough finished surfaces of concrete flat complete all as specified and directed.
23Form work to faces of walls, retaining walls, abutments, parapets & staircase railing and similar work including attached pillasters, buttresses, etc, vertical or to better rough finished surfaces of concrete flat complete all as specified and directed.
24Form work to sides of pillars, posts, struts, piers,columns, and stanchions rough finished surfaces of concrete Square, rectangular or polygonal complete all as specified and directed.
25S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled & countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete & screwing etc wind ties for roof including securing bolts, posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed.
26M&L for Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framedbalusters, walk ways, railings,framework of water tanks and similar work conforming to Fe.290 Gde-E-165 complete all as specified and directed.
27M&L Mild steel TMT bars 10mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed.
28M&L Mild steel TMT bars 5mm dia & over upto & including 10mm dia in stirrups, spacers & binders, cut to length, bent to shape required, binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed.
29S&F Rolled mild steel sections as in main & cross beams, hip & jack rafters, purlins where connected to common rafters & running rails & guides for sliding doors, fixed with angle cleats or other connecting plates GDE Fe 410-0 or Fe 310-O complete all as specified and directed.
30S&F Rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary & counter sunk) forming holes, without any attachment GDE Fe 410-0 or Fe 310-O complete all as specified and directed.
31S&F Rolled mild steel Roof trusses (framed), trussed purlins crane gantries, rails & fastenings & heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. GDE Fe 410-0 or Fe 310-O complete all as specified and directed.
32S&F Rolled mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with & including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails & guides) & hanging, also fastening & fixing complete GDE Fe 410-0 or Fe 310-O complete all as specified and directed.
33S&F Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 complete all as specified and directed.
34S&F Welded steel wire fabric supplied & fixed complete to wood or steel members Weight per square metre n.exc 4Kg complete all as specified and directed.
35S&F Plain, galvanised, mild steel sheeting 1mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
36S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as inroof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
37M&L 6mm thick asbestos cement, corrugated or semi corrugated shets in roofs, walls, etc, fixed with coach screws complete all as specified and directed.
38M&L 100mm thick PCC type B-2, (1:2:4) using 40mm graded crushed stone aggregate complete all as specified and directed.
39M&L 150mm thick PCC type B-2, (1:2:4) using 40mm graded crushed stone aggregate complete all as specified and directed.
40M&L 75mm thick PCC type C-2, (1:3:6) using 40mm graded crushed stone aggregate as in sub base, plinth protection including cutting and filling the grooves complete all as specified and directed.
41M&L 150mm thick PCC type C-2, (1:3:6) using 40mm graded crushed stone aggregate complete all as specified and directed.
42M&L Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed & pointed in neat cement slurry in floors with grey cement & pigment complete all as specified and directed.
43M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:6) complete all as specified and directed.
44M&L 20mm thick screed for laying floor finishes in CM (1:6) complete all as specified and directed.
45Taking down cement or cement lime plaster, any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
46Complete removal of existing treatment from wall surface and applying two coat of cement base paint over a coat of primer complete all as specified and directed.
47Preparation of old steel surface and applying two coats of fire resistance paint complete all as specified and directed.
48Preparation of new steel surface and applying two coats of fire resistance paint complete all as specified and directed.
49Applying two coats of synthetic enamel paint on steel & iron surfaces of any description, n.exc 10cm width or girth when unconnected with other painting or when painted in different tint, including preparation of new surface & applying one coat of red oxide, zinc chrome complete all as specified and directed.
50M&L for applying two coat of fire resistance paint any description wood, steel, iron, concrete, brick, stone, etc, exc 10cm in width or girth complete all as specified and directed.
51S&F for GI Pipe light grade for cable protection passing under road/floor or for fixing to poles of 50 mm dia complete all as specified and directed.
52Forming Contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound Grade "A" complete all as specified and directed.
53Demolition of Brickwork or stone/boulder masonry, built in CM or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework & precast concrete articles complete all as specified and directed.
54Demolition of PCC of any description & in any position not otherwise specifically provided for (unreinforced) complete all as specified and directed.
55Demolition of RCC of any description & in any position not otherwise specifically provided for complete all as specified and directed.
56Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
57Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed.
58S&F chimany with all fittings and fixture complete all as specified and directed.
59S&F XLPE insulated armoured and pvc sheated heavy duty electric cable with aluminium conductor 2 core, 10 Sqmm, 1100 volt grade laid in tranches passing through pipes /ducts including testing complete of following cross sectional area and size note- rate is inclusive of cable gland & cable lugs.
60S&F XLPE insulated armoured and pvc sheated heavy duty electric cable with aluminium conductor 4 core, 10 Sqmm, 1100 volt grade laid in tranches passing through pipes /ducts including testing complete of cross sectional area and size complete all as specified and directed. Note- Rate is inclusive of cable gland & cable lugs.
61S&F XLPE insulated armoured and pvc sheated heavy duty electric cable with aluminium conductor 4 core, 50 Sqmm, 1100 volt grade laid in tranches passing through pipes /ducts including testing complete of cross sectional area and size note- rate is inclusive of cable gland & cable lugs.
62Supply install commissioning and testing CPRI Approved factory fabricated, floor mounted outdoortype LT Feeder Pillar Box of suitable size fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 x 50 x 6 mm frame and 750mm above the Normal ground level complete factory made totally enclosed dust and vermin proof double door both side hinge opening arrangement on front and back with locking arrangement cable entry andexist from bottom with cable glands and gaskets, aluminium bus bar 250 Amps rating (01 Set) fixed on porcelain insulator with internal wiring with suitable size of aluminium strips to be used for incoming and outgoing connection of all switches/MCCB"s & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with copper lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint including necessary PCC (1:3:6) type C-2 as in foundation all as directed, comprising of the following : - (a)INCOMING (i)Thermal magnetic and microprocessor release MCCB 100 Amps, 4 Pole, 36 KA with front operated locking device. - 01 Nos (b)OUTGOING (i)Thermal magnetic MCCB 63 Amps, 4 Pole, 415V, 25 KA. Qty- 02 Nos. (ii) MCB 32 Amps, 2 Pole. Qty- 01 Nos. (c) (i)Digital Voltmeter 0 - 500 Volts with selector switch - 1 Set. (ii)Digital Amperemeter 0 - 200 Amps with selector switch - 1 Set. (iii) Indicator Lamp - R - Y - B (Set of three). (iv)Frequency meter 40-55 Hz - 01 Nos
63Taking down old/unservicable MCB DB any type and S&F for sheet metal enclosure MCB DB TPN 4 Way vertical type with 200 Amps rated bus bar 415 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
64Taking down old/unservicable MCBany type and S&F MCB triple Pole rated capacity 63 Amps, 415 Volts, breaking capcity10 KA "C" curve complete all as specified and directed.
65Taking down old/unservicable MCBany type and S&F MCB single Pole rated capacity 5 to 32 Amps, 240 Volts, breaking capcity10 KA "C" curve complete all as specified and directed.
66Taking down old un-serviceable flood light fitting of any type & size and S&F for Smart Bright essential flood LED light fitting of capacity 100 wattswith IP 65/66 protection and pre-wired and necessary mounting arrangements and provision of 2.5 sqmm three core copper conductor cable multistranded from ceiling rose to light fitting complete all as specified and directed. Make : Philips cat part No BVP142 P LED 100 CW FG GR PSU.
67M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground levelconnecting to and including GI steel strip of size 32 x 6mm by means of bolts, nuts, check nuts, and washers of galvanised iron or steel including 40 mm dia medium grade pipe for protection ofGI strip to the extent of 7.5 mtrs asearthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate S. No 3 of SSR Part-I (2009) including PCC foundation/ chamber in mix 1:2:4 type B-1 with angle iron frameCI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal complete all as specified and directed. Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
68UN-RESTRICTED AREA SCHEDULE
69Excavating over areas n.exc 1.5m deep & getting out in soft/loose soil complete all as specified and directed.
70Excavating in trenches n.exc 1.5m wide & n.exc 1.5m in depth for foundationetc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 Sqm on plan & getting out in soft/loose soil complete all as specified and directed.
71Excavation in trenchesfor laying of cables, poles and stay in any type of soil n.exc 1.5 mtr wide and n.exc 1.50 mtr deep and getting outin soft/loose soil complete all as specified and directed.
72Returning filling in, including spreading and leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
73Removing excavated materials n.exc 50 mtr and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
74M&L for Hardcore of Broken stone/boulders gauge n.exc 63mm, deposited, spread & levelled in layers n.exc 15 cm thick, watered & rammed to a true surface complete all as specified and directed.
75M&L for Moorum/red bajri filling in floors or pavings, laid in layers n.exc 15 cm thick spread, levelled & rammed including watering complete all as specified and directed.
76M&L PCC in foundations, filling and mass-concrete type D-2 (1:4:8) using 40 mm graded crushed stone aggregate complete all as specified and directed.
77M&L PCC in lintels upto 1.5 m clear span, cills, steps, seismic & other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating as directed type B-1 (1:2:4) using 20 mm graded crushed stone aggregate complete all as specified and directed.
78M&L Precast cement concrete type B-1 (1:2:4) using 20 mm graded crushed stone aggregate set in CM(1:4) in landings, cover slabs (for manholes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed.
79M&L RCC type B-1 (1:2:4) using 20 mm graded crushed stone aggregate in Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc basement slabs, under reamed piles and mass concrete complete all as specified and directed.
80M&L RCC type B-1 (1:2:4) using 20 mm graded crushed stone aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, chajja, deck slabs and in shelves and the like complete all as specified and directed.
81M&L RCC type B-1 (1:2:4) using 20 mm graded crushed stone aggregate in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
82M&L RCC type B-1 (1:2:4) using 20 mm graded crushed stone aggregate in columns, pillars, piers, posts and struts complete all as specified and directed.
83Supplying only Integral waterproofing compound (ISI Mark).
84M&L for Brick work with subclass `B" bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
85M&L brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed.
8640mm thick Damp proof course to horizontal or vertical surfaces including necessary form work in PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate.
87Form work to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams, and similar work, verticle or to batter rough finished surfaces of concrete flat complete all as specified and directed.
88Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work, n.exc 200mm thick (horizontal or sloping) rough finished surfaces of concrete flat complete all as specified and directed.
89Form work to sides & soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors & beams, etc rough finished surfaces of concrete flat complete all as specified and directed.
90Form work to sides of pillars, posts, struts, piers, columns, and stanchions rough finished surfaces of concrete Square, rectangular or polygonal complete all as specified and directed.
91S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles, & rails with suitable PVC sheet beading & joined together with solvent cement, in the frame at site as per specification & drawing complete all as specified and directed.
92S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, in opening as per specification & drawing complete all as specified and directed.
93S&F Aluminium, anodised, barrel tower bolts 150mm long of extruded section complete all as specified and directed.
94S&F Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
95S&F Butt hinges 100mm size, medium weight, cold rolled mild steel complete all as specified and directed.
96S&F Aluminium handles 150mm size, cast type, anodised complete all as specified and directed.
97S&F Factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing.
98M&L Mild steel TMT bars 10mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed.
99M&L Mild steel TMT bars 5mm dia & over upto & including 10mm dia in stirrups, spacers & binders, cut to length, bent to shape required, binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed.
100M&L Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed.
101S&F Steel ventilators with top hung shutter including hinges, steel peg stay complete all as specified and directed.
102M&L 75mm thick PCC type C-2, (1:3:6) using 40mm graded crushed stone aggregate as in sub base, plinth protection including cutting and filling the grooves complete all as specified and directed.
103M&L 100mm thick PCC type C-2, (1:3:6) using 40mm graded crushed stone aggregate complete all as specified and directed.
104M&L 75mm thick PCC type C-2, (1:3:6) using 40mm graded crushed stone aggregate as in plinth protection complete all as specified and directed.
105M&L 75mm thick PCC type D-2, (1:4:8) using 40mm graded crushed stone aggregate as in sub base complete all as specified and directed.
106S&F Coloured Glazed ceramic tiles in vertical surfaces350 x 250mm x 7mm/450 x 350 x 7mm thickset and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick plaster in CM(1:4) complete all as specified and directed.
107S&F Coloured Non Skid ceramic tiles7 to 8mm thick (squares/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm,in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM(1:4) complete all as specified and directed.
108M&L for colour rubber moulded chequered cement concrete tiles 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry in floors with white cement and pigments complete over 20mm screed bed in CM 1:6 complete all as specified and directed.
109M&L Water Proofing Treatment on roof surface (Horizontal & Vertical surfaces) in following sequence through manufacturer/authorized applicator of the manufacturer including taking down of existing roof treatment,properly cleaning & drying the concrete surfaces complete all as specified and directed :- (a)M&L 10 mm thick rendering on roof surfaces/concrete surface in CM 1:4 complete all as specified and directed. (b)Applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg / Sqm complete all as specified and directed. (c)Applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 kg/ Sqm including cleaning surfaces complete all as specified and directed. (d)Laying 3 mm thick unrolled over the bitumen coated surface, polymeric water proofing membrane Hyperplas standard weight not less than 3kg /Sqm with 100 mm over laps shall be sealed by flame as per manufacturers instruction complete all as specified and directed. (e)Applying two coats of bituminous base aluminium paintincluding preparation complete all as specified and directed.
110M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:4) finished even & smooth (without using extra lime or cement) complete all as specified and directed.
111M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces (without using extra cement)in CM (1:6) on external surface complete all as specified and directed.
112M&L Rendering 5mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling complete all as specified and directed.
113M&L for rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces,second layer (finishing coat)mixed withwater proofing compoundas per manufacturer"s instructions and finished the surfaces even and fair without using extra cement complete all as specified and directed. Note:WPC shall be measured and paid separately under relevant items.
114Applying three coats of white wash on new wall surface including preparation of surface complete all as specified and directed.
115Applying two coats of cement base paint, white or tinted on new wall surface including preparation of surface over a coat of primer complete all as specified and directed.
116Applying three coats of white wash on new ceiling surface including preparation of surface complete all as specified and directed.
117S&F Figured glass 4.0mm thick, pin head type & glazing with oil putty in squares n.exc 0.5 Sqm in each pane complete all as specified and directed.
118Applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome complete all as specified and directed.
119S&F Rotational moulded polyethylene water storage tanks 1000 Ltire capacity (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part-I 2009 complete all as specified and directed.
120S&F CP Bib taps 15 mm bore, cast copper alloy with crtuch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
121S&F CP Pillar taps fancy type 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot" or `Cold" with long screwed shanks & fly-nuts, screwed for iron pipe complete all as specified and directed.
122S&F Stop valves 15 mm bore, cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
123S&F Stop valves 20 mm bore, cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
124S&F Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
125S&F Ball brass valves 20mm bore, high pressure, with polythene float & flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
126S&F Grating doom 100 mm dia of PTMT (minimum weight 25 gms) complete all as specified and directed.
127S&F Towel rail 600mm long of PTMT fixed with & including CP brass screws & wooden/plastic cleats (minimum weight 190 gms) complete all as specified and directed.
128S&F PVC connections 15mm size with PTMT nuts of length 300mm complete all as specified and directed.
129S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
130S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
131S&F PVC (SWR) bends any radius 75mm dia complete all as specified and directed.
132S&F PVC (SWR) bends any radius 110mm dia complete all as specified and directed.
133S&F PVC (SWR) vent cowl 110mm dia complete all as specified and directed.
134S&F PVC (SWR) "S" trap of 110mm bore complete all as specified and directed.
135M&L PVC (SWR) gully trap 125/110 mm, setting & jointing with solvent cement complete all as specified and directed.
136M&L Concrete bed to 150mm dia drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested, in PCC (1:4:8) complete all as specified and directed.
137M&L Salt glazed stoneware drain pipes laid in trenches & jointed as specfified of 150mm dia complete all as specified and directed.
138S&F Soap dish, CP, approximate size 160 x 160 x 90mm complete all as specified and directed.
139S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern & flush pipe) complete all as specified and directed.
140S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (min.), with grating & union for discharge pipe (excluding flushing cistern, flush pipe & waste pipe) complete all as specified and directed.
141S&FPVC valveless, syphonic action type, flushing cistern 10 litre capacity, low level, white, with intel, ball valve, float & handle including brackets complete all as specified and directed.
142S&F in repairs Plastic water closet seat, black, closed pattern with flat bottom, & cover & mild steel CP or aluminised hinging device complete all as specified and directed.
143S&F Vitreous China wash basin, white, flat back, size 550 x 400mm excluding taps, waste chain & plug & porcelain stopper but including brackets complete all as specified and directed.
144S&F 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood & fixed to wooden plugs with CP brass screws & cup washers complete all as specified and directed.
145S&F UPVC Tubes with all fitting & fixed complete to walls & ceilings or laid in floors of 15mm bore complete all as specified and directed.
146S&F UPVC Tubes with all fitting & fixed complete to walls & ceilings or laid in floors of 20mm bore complete all as specified and directed.
147On site LLDPE septic tankdesigned to carry sewage and slduge water excavation in any type of soil PCC 1:4:8 below foundation vent shaft connection etc complete for 25 users complete all as specified and directed.
148Construction of Soakage Well of 1.20 m internal dia and 1.5 m effective depth including excavation and earth work, PCC, brick masonry and RCC slabs complete all as shown on drgand specified (Drg No CEJZ/TD/58 Sheet I & II ).
149Note : Structural design will be done by the the contractor as specified.
150Schedule of credit amount of Rs. 70,221.00 to be deducted during AOC
Disclaimer :