Tender For Repair/ Replacement Of Flame Proof Wiring And Connected Work At Af Stn Thoise Under Ge (Af) Thoise
Tender Overview
Project Description
Tender For Repair / Replacement Of Flame Proof Wiring And Connected Work At Af Stn Thoise Under Ge ( Af ) Thoise
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Nov-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 18-Nov-2023 |
| 2 | 06-Nov-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-Nov-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully existing unserviceable flame proofaluminum/copper point wiring of any description & in anyposition with and including existing conduit fixed on surface with and including existing junction boxes in between the point wiring complete, including making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed by Engr-in-Charge.NOTE: (i) Old existing junction boxes obtained in serviceable condition from taking down of point wiring shall be re-used in the work.(ii) Taking down / replacement of existing fittings like switches/sockets / switch fuses /tube light fittings etc. if any, shall be measured and paid for separately under appropriate item of Schedule `A\" |
| 2 | Material and labour for flame proof point wiring for one light point or one socket point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade in and including stove enameled black, rigid steel conduits of size not less than 15 mm dia (Medium grade) fixed on surface of walls/ceilings as directed with all accessories andusing 1.5 Sqmm (nominal area) stranded copper conductor single core FRLS, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly / fittings etc. complete all as specified and directed by Engr-in-Charge.NOTE : (i) Old junction boxes retrieved inserviceable conditions shall be re-used in the work.However, additional junction boxes, if any required, for making new point wiring other than the quantity of junction boxes retrieved from taking downof point wiring, shall be measured and paid for separately as ‘’supply only’’ under appropriate item of Schedule `A\" but fixing element of any type of junction boxes new or old is deemed to be included in the rates quoted by the contractor for the above item.(ii) Wiring shall be terminated and connected to the relevant switch / controlling switch gear and relevant fittings / sockets all as directed and controlling switch / fittings shall be measured and paid for separately under appropriate item of Schedule `A\". Copper Cable - Polycab/Havells/Finolex/L&TSteel Conduit- NIC/TATA/Jindal/Kalinga/AKG |
| 3 | All as per BOQ Srl item No 2.00 above but point wiring with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable for 16 Amps Flame proof Switch and socket complete all as specified and directed by Engr-in-Charge. |
| 4 | Material and labour for flame proof point wiring for one light point or one socket point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade in existingsteel conduit fixed on surface of walls/ceilings as directed andusing 1.5 Sqmm (nominal area) stranded copper conductor single core FRLS, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly / fittings etc. complete all as specified and directed by Engr-in-Charge.NOTE : (i)Point wiring shall be executed with using existing conduits and junction boxes but contractor’s quoted rates for the above item is deemed to include the cost of fixing the existing conduits and junction boxes in position properly as per site requirement and as directed by the Engineer-in-Charge. (ii) Wiring shall be terminated and connected to the relevant switch / controlling switch gear and relevant fittings / sockets all as directed and controlling switch / fittings shall be measured and paid for separately under appropriate item of Schedule `A\".Make:-Copper Cable - Polycab/Havells/Finolex/L&T |
| 5 | All as per BOQ Srl item No 4.00 above but point wiring for 2 light points controlled by one switch complete all as specified and directed by Engr-in-Charge. |
| 6 | All as per BOQ Srl item No 4.00 above but point wiring with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable for 16 A Flame proof Switch and socket complete all as specified and directed by Engr-in-Charge. |
| 7 | Taking down carefully u/s worn out wires of sub main wiring from existing conduit and complete all as specified and directed by Engr-in-Charge. |
| 8 | Replacement of old unserviceable sub main wiring for circuit/ submain wiring alongwith earth wire with two run of 1.5 sqmm of , PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100Volts grade and one run of 1.5 sqmm, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, and including concealed 25 mm dia PVC conduit 2 mm thick with all fittings, ISI marked, incl. cutting chases & making good disturbed surfaces of walls , floors etc to match with existing surface complete all as specified and directed by Engr-in-Charge. |
| 9 | Disconnecting and taking down carefully flame proof, weather proof, switches any type and making good the disturbed surfaces complete all as specified and directed by Engr-in-Charge. |
| 10 | Disconnecting and taking down carefully flame proof, Switch socketof any capacity and making good the disturbed surface complete all as specified and directed by Engr-in-Charge. |
| 11 | Supply and Fixingflame proof16A Single pole ON-OFF /rotary type switch of any description any capacity or make complete all as specified and directed by Engr-in-Charge.Make: Cat Part No RI/OA/1010-2A of Sudhir Switchgears Ltd or equivalent in Crompton Greaves/ Shyam Switchgears/ Flexpro Electricals/ Bajaj/Philips |
| 12 | Supplying & fixing flame proof, switch socket & plug combined made of aluminum alloy LM-6 having 2 pole + earth suitable for 250 volts supply and current rating of 16 Amps complete all as specified and directed by Engr-in-Charge. Make – Cat part No. SS/OA/1010 -1 of Sudhir Switchgears Ltd or equivalent in Crompton Greaves/ Shyam Switchgears/ Flexpro Electricals/ Bajaj/Philips |
| 13 | Disconnecting and taking down carefullyunserviceable Flame proof light fitting any type and making good the disturbed surfaces complete all as specified and directed by Engr-in-Charge. |
| 14 | S&F in repairflame proof point weather proof LED tube light fitting box type with 1x16 W led tube fitting including connecting electrically to ceiling using flexible 3 core PVC insulated over all sheated with flexible copper conductor of size .75 Sqmm all as required complete all as specified & directed by Engr-in-charge. Make : Havells/Bajaj/Crompton Greaves/Sudhir Switchgears/Syska/Bajaj/Philips |
| 15 | Supplying & fixing in repair /replacment flame proof fluorescent tube light fittings 1 x 36/40 watt as per IS : 2148 / 1981 & 2206 (Part-I )1984, Temperature class T-4,& made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plane washersheat resistant glass of make Borosil complete with starter, holder, choke etc &pre-wired including reflectors and wire guardsand including one No fluorescent tube 40 watt, fitting fix to wall/ceiling with using old existing fixing arrangements all as specified and directed by Engineer-in-Charge. Make :Cat Part No FF/OA/1271/401 of Sudhir Switchgears Ltd/Crompton Greaves/ Shyam Switchgears/ Flexpro Electricals/Bajaj/Philips/ Havells/Syska |
| 16 | Supply and fixing of flameproof cum waterproof LED high baylightlight fitting70 watt, IP66 protectionof cast Aluminium alloy mterial heat resistant , toughened clear glass having anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge. |
| 17 | Supply and fixing of flameproof cum waterproof LED Bulk headlight fitting30watt, IP66 protectionof cast Aluminium alloy mterial heat resistant , toughened clear glass having anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable sizecomplete all as specified and directed by Engr-in-Charge. |
| 18 | Supply and fixing flexible metal conduit 15 mm diaflame proof complete all as specified & directed by Engr-in-charge.Make: Bajaj /SUDHIR/NIC/Jindal/Kalinga. |
| 19 | S&F in replacement of porcelain lamp holderwith complete fitting suitable for HPMV/ HPSV lampscomplete all as specified and directed by Engr-in- Charge.Make - Bajaj/ Sudhir/ philips/Havells/Syska/Crompton Greaves |
| 20 | S&F in repair open construction HPSV/MH Ballast copper wound 150 watt suitable for 150 watt HPSV/MH fitting complete all as specified & directed by Engr-in-charge. Make :- Bajaj Catpart no - BJOS150 SV/MH or equivalent in Bajaj/Havells/Syska/Crompton Greaves. |
| 21 | S&F in repair Igniter suitable for HPSV/ MH lamp fitting of cap 70/ 150/ 250 watt complete all as specified & directed by Engr-in-charge.Make :- Bajaj Cat part No - BJIGN HPSV1 or equivalent in Bajaj/Havells/Syska/Crompton Greaves. |
| 22 | S&F in repair HPSV/ MH lamp fitting of cap 70/ 150/ 250 watt complete all as specified & directed by Engr-in-charge.Make :- Bajaj Cat part No - BJIGN HPSV1 or equivalent in Bajaj/Havells/Syska/Crompton Greaves. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender