Tender For Construction Of A Road Connecting To Biswanath Temple Approach Road To Parking Area Yatri Niwas At The Hill Top As Well As Beautification And Development Of Biswanath Temple Block_Delanga Dist_Puri, delanga-Odisha

Zilla Parishad-ZP has published Tender For Construction Of A Road Connecting To Biswanath Temple Approach Road To Parking Area Yatri Niwas At The Hill Top As Well As Beautification And Development Of Biswanath Temple Block_Delanga Dist_Puri. Submission Date for this Tender is 08-11-2023. Road Work Tenders in delanga Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

40300400
Corrigendum : Tender For Construction Of A Road Connecting To Biswanath Temple Approach Road To Parking Area Yatri Niwas At The Hill Top As Well As Beautification And Development Of Biswanath Temple Block_Delanga Dist_Puri
National Competitive Bid
Indian
Odisha
delanga
08-11-2023

Tender Details

Construction Of A Road Connecting To Biswanath Temple Approach Road To Parking Area Yatri Niwas At The Hill Top As Well As Beautification And Development Of Biswanath Temple Block_Delanga Dist_Puri

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Oct-2023 Corrigendum 1 Other 08-11-2023

Key Value

Document Fees
INR 7080 /-
EMD
INR 83069.0 /-
Tender Value
INR 83.06 Lakhs /-

BOQ Items

Name of Work: Construction of a road connecting to Biswanath Temple, approach road to parking area, Yatri Niwas as the Hill top as well as beautification and development of Biswanath Temple, Block-Delanga, Dist- Puri DIST - PURI, ODISHA
Sl. No. Item Description
1Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.etc. complete as per direction of Engg-in-Charge
2Foundation excavation in Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014cum in volume within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the department etc. complete as per direction of Engg-in-Charge .
3Removal of unserviceable soil including excavation loading and disposal up to 1000 mtr lead with Hydraullic Excavator of 0.9 cum bucket Capacityas per specification approved by the department etc. complete as per direction of Engg-in-Charge .
4Filling foundation and plinth with sand and well watered and rammed including cost, conveyance and royalty etc complete asper direction of Engg.-in-Charge.
5Cement concrete (1:3:6)with 40mm size CBHG metal including cost, conveyance and royalty etc. completeas per direction of Engg.-in-Charge.
6i Part-E Sl.No.3
7Cement Concrete (1:2:4) with 12 mm size broken hard granite chips for R.C.C. works including hoisting and laying etc. complete as per direction of Engg-in-Charge .
8i Part-B Sl.No.2ii Part-E Sl. No.4
9Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018etc. complete as per direction of Engg-in-Charge .
10Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm ofM-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect confonning to IS 5758: 1984. etc. complete as per direction of Engg-in-Charge .
11Cutting in disintegrated rock not requiring blasting to be removed by pick axes and crow bars and depositing materials within 50m lead and 1.5m initial lift including rough dressing as per direction and specification of the department including stacking useful materials separately as ordered. (per 100 Cum.) etc. complete as per direction of Engg-in-Charge .
12Supply fitting and fixing MS grill / Iron work wrought and put up in window grating including drilling holes in choukathas /(MS hand rail including Enamel paint for hand rail ) etc. complete as per direction of Engg-in-Charge .
13i Part-E Sl.No.21 ii Part-I Sl. No.9
14Fixing industrial Chequred tiles in floors,treads or steps and landings on 25 mm thick CM (1:1) jointed with neat cement slurry mixed with pigments to match the shades includind cost for rubbing, polishing & cost of marbel tiles etc. completeas per direction of Engg-in-Charge .
15Earth work by mechanical means borrowed from out side within 5km initial lead and 1.5m initial lift including levelling and dressing the bed and sides depositing muck within initial lead and lift etc. complete as per direction of Engg-in-Charge .
16Brick work with Fly Ash Bricks having crushing strength 75 kg/sq.cm in c.m. 1:6 in F & P including cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge .i) Part-DSl No.4
17ii) Part-ESl No.5
18Brick work with Fly Ash .Bricks having crushing strength between 100kg/sq.cm to 149kg/sq.cm in c.m. 1:6 in Sup.Str. including cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge .
1916mm. thick cementplaster in c.m. 1:6 over brick masonryincluding cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge . i) Part-DSl No.6
20ii) Part-ESl No.10
21Cement washing one coats with cost of all labour & materials etc. complete as per direction of Engg-in-Charge . i) Part-DSl No.7
22ii) Part-ESl No.16
23Wall Priming onecoats on new work with wall water bound primer ofapproved shadeas per direction of Engg-in-Charge .i) Part-DSl No.8
24ii) Part-ESl No.17
25Wall painting two coats on new work with Weather coat paint ofapproved shadeas per direction of Engg-in-Charge .i) Part-DSl No.9
26ii) Part-ESl No.20
27Marking and painting lines or arrows for road markingetc. completeas per direction of Engg-in-Charge .
28Painting and writing road signs of all kinds as per I.R.C. standard including painting boards. etc. completeas per direction of Engg-in-Charge .
292.5cm. thick A.S.Flooring with C.C.1:2:4 using 12mm. size HBG crusher broken chips including punning,cost,conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge .
30Providing and Laying reinforcement Cement concrete (M-20) with 20 mm and down graded chips including cost all materials,labours,T & P,curing etc complete (excluding the cost of reinforcement & Centering, shuttering) as per direction of Engineer-in-charge. A- Column Base a i Part-E Sl. No.7(a)
31b i- Part-HSl. No.4 (a)ii- Part-ISl. No.4 (a)
32B- Tie Beam
33C- Beam & column Ground Floor a i Part-E Sl. No.7(b)
34b i- Part-HSl. No.4 (c)ii- Part-ISl. No.4 (c)
35D- 65mm avg. Chajja Ground Floor
36E- Roof Slab Ground Floor a i- Part-ESl. No.7 (d)
37b i- Part-HSl. No.4 (d)ii- Part-ISl. No.4 (d)
38F- Lintel Ground Floor Part-E Sl. No.7(e)
39Supplying, fitting and placing uncoated HYSD bar reinforcement complete in proper position including cost of binding wire 18 to 20 gauge as per direction of Engg.-in-Charge.Ground Floora i Part-E Sl. No.8
40b i- Part-HSl. No.5ii- Part-ISl. No.6
4112mm cement plaster in cement mortar (1:6)including necessary scaffolding curing etc. as per direction of Engg.-in-Charge.Ground Floor
426mm.thick cement plaster with C.M(1:4) to RCC surface including closed deep chipping and slury treatment etc. complete as per direction of Engg.-in-Charge.Ground Floor a- i-Part-E Sl. No.11
43b i- Part-HSl. No.6ii- Part-ISl. No.6
44Fixing colour Vitrifiedtiles in floors (Printed Series)of size 600mm x600 mm of approved make conforming IS:13755 laid on 20 mm thick cement mortar (1:4)and filling joints with white cement of approved qualityincluding cost of all materials, labour T&P etc rrequired for the work all completeas per direction of Engineer-in-charge.
45Fixing Vitrifiedtiles in dados (Printed Series)skirting and risers of stepson 12 mm thick cement plaster(1:3) jointed with neat cement slurry mixed with pigments to matche shade of the tiles including rubbing and polishing completeasper direction of Engineer-in-charge.
46Fixing Granitetiles ofsize above 0.4 Sqm. (20mm. thick) in floors,treads or steps and landings on 25 mm thick CM (1:1) jointed with neat cement slurry mixed with pigments to match the shades includind cost for rubbing, polishing & cost of marbel tiles etc. completeas per direction of Engg-in-Charge . Ground Floor i Part-E Sl. No.14
47ii Part-H Sl. No.8
48Fixing granite tiles of0.10 Sqm. & upto 0.4 Sqm. (10mm. thick)in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades includind cost for rubbing, poloshing complete excluding cost oftiles etc. completeas per direction of Engg-in-Charge . Ground Floor i Part-E Sl. No.15
49b i- Part-HSl. No.7 ii- Part-ISl. No.7
50Wall painting two coatswith Plastic emulsion paint ofapproved shadeas per direction of Engg-in-Charge .
51Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T & P etc. complete as per direction of Engg-in-Charge .
52Eamel Painting two coats with enamel paint over one coat of primer of approved quality etc. complete as per direction of Engg-in-Charge .
532.5cm.grading concrete (1:2:2) on roof slab using 6mm.size CBHG chips including cost,conveyance and royalty of materials curing etc.complete as per direction of Engg-in-Charge .
54Fixing Floor tiles in floors,treads or steps and landings on 25 mm thick CM (1:1) jointed with neat cement slurry mixed with pigments to match the shades includind cost for rubbing, polishing & cost of marbel tiles etc. completeas per direction of Engg-in-Charge .
55Fixing Ceramic Glazed wall tiles in dados skirting and risers of stepson 12 mm thick cement plaster(1:3) jointed with neat cement slurry mixed with pigments to matche shade of the tiles including rubbing and polishing completeasper direction of Engineer-in-charge.
56Fixing industrial Chequred tiles in floors,treads or steps and landings on 25 mm thick CM (1:1) jointed with neat cement slurry mixed with pigments to match the shades includind cost for rubbing, polishing & cost oftiles etc. completeas per direction of Engg-in-Charge .
57Supplying , fitting and fixing of two Track UPVC sliding window of approved make with 6mm thick glass of approved qualitycomplete with frame. shutters and all fitting and fixtures etc. completeas per direction of Engg-in-Charge .
5812mm. thick cementplaster in c.m. 1:4 over brick masonryincluding cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge .
59Cement punning including cost, conveyance of cement and curing etc. complete as per direction of Engg-in-Charge .
60Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front modular cover of suitable size , MS modular box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex / L&T / Anchor / Havels / V Guard )Part-F Sl.No.1 i Group-A
61ii Group-B
62iii Group-C
63Supplying and fixing of following MODULAR type Bell pushon the existing switch box / cover including connections etc as required. as per direction of Engineer in Charge. ( Make of wire Finolex / L&T / Anchor / Havels / V Guard ) Part-FSl. No.2 Ground Floor
64Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor o f ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/L&T/Anchor/Havels/V Guard)Part-FSl. No.3 Ground Floor
65Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/L&T/Anchor/Havels/V Guard)Part-FSl. No.4 Ground Floor
66Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/L&T/Anchor/Havels/V Guard) Part-FSl. No.5 Ground Floor
67Recessed wiring to submain in 2 x 10 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/L&T/Anchor/Havels/V Guard)Part-FSl. No.6 Ground Floor
68Recessed wiring to Supply and fixing of01 no.sof 3pin 5/6 amp modular socket and S.P. 5/6 amp one way modular switch, 1 no. of 5 pin 15/16 socket out let and S.P. 15/16 A one way modular switch on Modular G.I. Box with Modular Base and cover. (Make of wire Finolex/L&T/Anchor/Havels/V Guard)Part-FSl. No.7 Ground Floor
69Supply and fixing of 3 pin 6Amp plugwith 6Amp switch on existing board (Modulartype ).(Make of wire Finolex/L&T/Anchor/Havels/V Guard) Part-FSl. No.8 Ground Floor
70Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 03 no.s of 6 pin 5/6 & 01 no. of 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.(Make of wireFinolex/L&T/ Anchor/ Havels/V Guard) Part-FSl. No.9 Ground Floor
71Supply and fixing of following way single pole and neutral, sheet steel, MCB distribution board consumer unit, 240 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic covr for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB / RCCB / Isolator) 6 WAY (8 + 18) DOUBLE DOOR, HORIZONTAL TYPE Part-FSl. No.10 Ground Floor
72Supply and fixing of 5Amp to 32A rating 240V "B/C" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. as required.(make-HPL/ Havells/ Legrand /L&T/C&S) Part-FSl. No.11 Ground Floor
73Copper Earth Plate electrode Supply and fixing of copper plate earthing( 600 X 600 X 3.15mm )with running copper flat 25 X 5mm from copper plate to funnel of40mm dia G.I pipe including all accessories etc. as required.(make-HPL/ Havells/ Legrand /L&T/C&S)Part-FSl. No.12 Ground Floor
74Salt / charcoal for pipe earth electrode Copper Earth Plate electrodeExtra for using salt and charcoal for G.I or copper pipe earth elctrrode as required.(make-HPL/ Havells/ Legrand /L&T/C&S) Part-FSl. No.13 Ground Floor
75S/F of 1200mm High Speed Ceiling fan Alluminium Body, Copper winding, High speed ceiling fan (Make-Crompton Model-Riviera High Speed, Polycab Model-Vital, Polar Model-Winpro) etc. Part-FSl. No.14 Ground Floor
76S/F of 8" PLASTIC VENTILLATING FAN exhaust fan (Make-Crompton Model-Jura, Polycab Model-Vital, Polar Model-Winpro) etc. Part-FSl. No.15 Ground Floor
77S/Fof 1x18 Watt LED T-5 fitting(Make-Crompton/Philips/Havells/Bajaj)Part-FSl. No.16 Ground Floor
78S/Fof 60 W LED Street light fitting(Make-Crompton/Philips/Havells/Bajaj) Part-FSl. No.17 Ground Floor
79S/F OF TP & N SFU IN CUBICAL PANEL BOARD Providing and fixing of following capacity TP& N disconnector fuse switch unit inside existing cubical panel board with ISI marked HRC fuses including drilling holes in cubical pannel, makinfg connection as requred etc, completePart-FSl. No.18 Ground Floor
80MV cable laying up to 25 sq.mm on surface Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size notexceeding 25 sq.mmon surface as required.Part-FSl. No.19 Ground Floor
81Fixing of lightning conductor finial Fixing of lightning conductor finial made up of 25 mm dia 300 mm long , Copper tube / G.I. tube having single prong at top with 85 mm dia 6 mm thick G.I. base plate ISI marked including holes etc. as requredincluding all connections. Part-FSl. No.20 Ground Floor
82P/F of copper tape on parapet or wall surface (Vertical run) Providing and fixing of copper tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)as required.Part-FSl. No.21 Ground Floor
83S/F OF MAIN SWITCHES ISI Marked-100Amp TPN Supply, Installation, Testing, and Commissioning of 100 Amp TPN Main switches of following capacity (IS 13940 Part 3/1993 ) on existing surface / wall mountnting and complete with HRC Fuse links, interconnections, earthing, etc. as required as per direction of Engineer in Charge.Make- SEIMENS/HPL/ANCHOR/L&T/HAVELS/C & S/ RKPart-FSl. No.22 Ground Floor
84Providing and fixing M.V danger board of 250 mm x 200 mm made mild steel at least 2 mm thick and vitreous enameled white on both sides and with inscription in single red colours on front side as requred.Part-FSl. No.23 Ground Floor
85S/F of 20 Watt LED Square surface mountfitting (Make-Havells/Philips/C&S/Crompton) as requred.Part-FSl. No.24 Ground Floor
86Supply fitting and fixing Concrete Garden chair (3 seater) of approved make including all materials, labours andtrnasporting,etc. completeas per direction of Engg-in-Charge .i Part-I Sl. No.10 ii Part-J(b) Sl.No.1
87Supply and fixing 18W Integrated solar streetlight suitable for perfect solar system solution for remote & off grid locations. Housing in aluminium alloy body which makes it water & rust proof with IP65.Enclosed inside the unit multi cell LEP Technology BATTERY Lithium Ion/Oxide 24Ah+1%,12.8V+0.4V,Max continuous discharge current (w/o PCM)upto42A,should conform to the latest BIS/International standards which is charged by a highly effiecient mono-crystalline solar panel.The LED Iuminary delivers close to 120 lumens per watt and is made from the finest LEDs from Bridgelux/Oshram/Philips confirmed to BIS specification.The light must have dust to drawn system to auto control the device.The Streetlight is a plug & play unit and can be very easily mounted on walls or poles via the extensions provided with the product itself.A manual ON/OFF switch has also been provided so that the light can be awitched off when not in use for a long timeetc. complete as per direction of Engg-in-Charge . Part-J(a) Sl.No.3
88Supply fitting and fixing different signage for parking, awareness of people, information guide etc. including all materials, labours andtrnasporting,etc. completeas per direction of Engg-in-Charge . Part-J(c) Sl.No.1
89Supply fitting and fixing 1.50M high bamboo fencing with muli bamboo posts and strong bamboo frame work including all materials etc. completeas per direction of Engg-in-Charge .Part-J(d) Sl.No.1
90Supply fitting and fixing 1.50M high bamboo fencing with muli bamboo posts and strong bamboo frame work including all materials etc. completeas per direction of Engg-in-Charge .Part-J(d) Sl.No.2
91Cutting holes through existing brick work including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc all complete as per Engg.-in- charge. 250mm wall Part-G Sl.No.1 All Floors
92Cutting holes in R.C.C floors and roos upto 19cm thick for passing G.I/P.V.C pipes and fitting etc. and prepairing the holes after insertion of pipe etc. with cement concrete 1:2:4 including finishing complete so as to make it leak proof as per Engg.-in- charge. Part-G Sl.No.2 All Floors
93Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per specification etc complete as per Engg.-in- charge. Part-G Sl.No.3 All Floors
94Providing and fixing on wall face unplasticised Rigid PVC soil, waste and rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes complete as per direction of Engineer-in-Charge a-75 MM OD PVC SWR S/S Pipe (ISI Type-A) Part-GSl.No.4(i)All Floors
95b- 90 MM OD PVC SWR S/S Pipe (ISI Type-A) For Rain WaterPart-GSl.No.4(iii)All Floors
96c- 110 MM OD PVC SWR S/S Pipe (ISI Type-A) Part-GSl.No.4(i)All Floors
97Laying in trenches unplasticised PVC pipes IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by heat application method including testing as per specification complete. (Earth work in trenches to be measured and paid for separately) a- 125mmdia rigid UPVC pipe Class -3 (0.60Mpa)Part-GSl.No.5(i)All Floors
98b- 160mmdia rigid UPVC pipe Class -3 (0.60Mpa)Part-GSl.No.5(ii)All Floors
99Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge a- 20mm dia pipe Part-GSl.No.6(i)All Floors
100b- 25mm dia pipe Part-GSl.No.6(ii) All Floors
101c- 40mm dia pipe Part-GSl.No.6(iii)All Floors
102Providing and fixing on wall face unplasticised-PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansios etc complete as per direction of Engineer-in-Charge A- PVC SWR coupler i) 75 mm dia PVC SWR coupler Part-GSl.No.7A(i) All Floors
103ii) 90 mm dia PVC SWR coupler Part-GSl.No.7A(ii) All Floors
104iii) 110 mm dia PVC SWR coupler Part-GSl.No.7A(iii) All Floors
105B- Single Tee with door i) 75 x 75 x 75 mm dia PVC SWR coupler Part-GSl.No.7B(i) All Floors
106ii) 90 x 90 x 90 mm dia PVC SWR coupler Part-GSl.No.7B(ii) All Floors
107iii) 110 x 110 x 110 mm dia PVC SWR coupler Part-GSl.No.7B(iii) All Floors
108C- SWR Plain Bend 87.5° i) 75mm diaP.V.C. SWR plain bend 87.5 Part-GSl.No.7C(i) All Floors
109ii) 90mm diaP.V.C. SWR plain bend 87.5 Part-GSl.No.7C(ii) All Floors
110iii) 110 mm diaP.V.C. SWR plain bend 87.5 Part-GSl.No.7C(iii) All Floors
111D- SWR Plain Door Bend 87.5° i) 75mm diaP.V.C. SWR plain bend 87.5 Part-GSl.No.7D(i) All Floors
112ii) 90mm diaP.V.C. SWR plain bend 87.5 Part-GSl.No.7D(ii) All Floors
113iii) 110 mm diaP.V.C. SWR plain bend 87.5 Part-GSl.No.7D(iii) All Floors
114Fixing 100mm size ‘P’ or ‘S’ trap (with horn or without horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1) as per specification. etc complete as per direction of Engineer-in-Charge.‘P’trap (with horn or without horn)(All Floor)
115‘S’trap (with horn or without horn)(All Floor)
116Fixing water closet, squatting pan (Indian type W.C pan) conforming to IS 2556 : Part 3-2004 duly embedded in cement concrete (1:4:8) using hard granite metal 4cm nominal size all complete as per specification alletc. complete as per direction of Engg. in charge.(All Floor)
117Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixersetc. completeas per direction of Engg. in charge.(All Floor)
118FixingWash Basinwith hole for pillar type with cast iron or M S bracket painted white including cutting holes in the walls and making good the damagesetc. complete as per direction of Engg. in charge. For Wash Room Porcelain Counter Top Basin Oval Shape (550x430)(All Floor)
119FixingWash Basinwith hole for pillar type with cast iron or M S bracket painted white including cutting holes in the walls and making good the damagesetc. complete as per direction of Engg. in charge. Porcelain 22"x 16"(550x400) W.H.B.(All Floor)
120Fixing bowl pattern urinal conforming to IS 2556 : Part 6-1996 including connecting the urinal of 430x260x350 mm or 340x410x265 mm sizes respectively with waste pipe by means of white lead mixed with chopped hemp etc all complete as per specification.etc. complete as per direction of Engg. in charge Porcelain Flat back stall type magnum Urinal . (All Floor)
121Fixing glazed earthenware squatting plate of size 600mm x 350mm conforming to IS:2556- Part-6-1995 with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:4:8) using 40mm hard granite metal all complete as per specification etc. complete as per direction of Engg. in charge. One-seated Urinal 1m x 0.50m x 0.15m size.(All Floor)
122Fixing PVC waste pipe of following nominal diameter for wash basin or sink including brass check nut complete as per specificationetc. complete as per direction of Engg. in charge. (All Floor)
123Fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin complete as per specificationetc. complete as per direction of Engg. in charge.(All Floor)
124Fixing of Brass Screw-down Bib Cocks (Taps) polished bright conforming to IS:781-1995 of the following nominal sizes as per specificationetc. complete as per direction of Engg. in charge.15mm Short Body Bib Cock (All Floor)
12515mm Long Body Bib Cock. (All Floor)
126Fixing of Brass Screw-down Angle/Counseales stop cock Cocks polished bright conforming to IS:781-1995 of the following nominal sizes as per specificationetc. complete as per direction of Engg. in charge. 20mm dia CP Brass Concealed Stop Cock (All Floor)
127Fixing of Brass 15mm dia CP flange of the following nominal sizes as per specificationetc. complete as per direction of Engg. in charge.15mm dia CP flange(All Floor)
128Fixing Bib Cock capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of the following nominal bore as per specificationetc. complete as per direction of Engg. in charge. 15mm dia C.P. Pillar cock with swinging spout.(All Floor)
129C.P.revolving shower (bend type).(All Floor)
130CP Health Foucet with 1.0 mtr PVC Tube(All Floor)
131Fixing 600mm x 450mm bevelled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with chromium plated brass screws and washers complete as per specificationetc. complete as per direction of Engg. in charge. 600mm x 450mm bevelled edge mirror. (All Floor)
132Fixing standard sized glass-shelf with Chromium Plated brass brackets and guard rails complete, fixed to woden plugs with Chromium Plated brass screws as per specification complete as per direction of Engg. in charge. C.P. glass self with glass(All Floor)
133Fixing standard sized Chromium Plated brass towel rail complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws, complete as per specification. complete as per direction of Engg. in charge. C.P. towel rail.(600x20)mm(All Floor)
134Fixing (a) Liquid Soap Container – Glass container or Plastic container with Chromium Plated brass lid and brackets fixed to wooden plugs with Chromium Plated brass screws or (b) Chromium Plated brass soap dish complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws or (c) white glazed tooth brush holder fixed to wooden plugs with Chromium Plated brass screws as per specification complete as per direction of Engg. in charge. C.P Soap holder/disc.(All Floor)
135Fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position etc all complete as per specification complete as per direction of Engg. in charge.1000 litre capacity Double Layer Cylinderical Vertical water storage tanks
136Supply , fitting and fixing of following fixers including all materials and labours etc all complete as per specification complete as per direction of Engg. in charge.450x450mm Square Man Hole Cover -16.0 kg
13790mm dia P.V.C. Nahani Trap
138110mm dia PVC SWR Single Y with door
139PVC SWR Jalli 110mm dia
140110 mm dia P.V.C. SWR Vent Cowl
141UPVC BALL VALVE Sch-80 (Solvent Welded with Metal Ball)25mmdia
14240mmdia
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail