Charkhi: Augmentation Of Water Supply Scheme Of Village Charkhi By Renovation Of Existing Structures, Construction Of 1 B/Stations, Laying The Di Pipe Lines,District Charkhi Dadri (Under Cm Announcement) `Construction Of Raw Water Pumping Station, Layi, Charki Dadri-Haryana

Public Health Engineering Department-PHED has published Charkhi: Augmentation Of Water Supply Scheme Of Village Charkhi By Renovation Of Existing Structures, Construction Of 1 B/Stations, Laying The Di Pipe Lines,District Charkhi Dadri (Under Cm Announcement) `Construction Of Raw Water Pumping Station, Layi. Submission Date for this Tender is 25-10-2023. Water Pipe Line Tenders in Charki Dadri Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

40296525
Charkhi: Augmentation Of Water Supply Scheme Of Village Charkhi By Renovation Of Existing Structures, Construction Of 1 B/Stations, Laying The Di Pipe Lines,District Charkhi Dadri (Under Cm Announcement) `Construction Of Raw Water Pumping Station, Layi
Open Tender
Indian
Haryana
Charki Dadri
25-10-2023

Tender Details

Charkhi: Augmentation Of Water Supply Scheme Of Village Charkhi By Renovation Of Existing Structures, Construction Of 1 B / Stations, Laying The Di Pipe Lines, District Charkhi Dadri ( Under Cm Announcement ) `Construction Of Raw Water Pumping Station, Laying The Rising Main Line, Construction Of Rcc Sands Tanks, Filter Bed, Clear Water Tank, Repair Of Existing Structures And All Other Works Contingent Thereto. Oandm For 5 Years After Defect Liability Period Of 1 Year And Trial Run Of 3 Months Complete In All Respect.`

Key Value

Document Fees
INR 20000 /-
EMD
INR 1394996.0 /-
Tender Value
INR 6.97 Crore /-

BOQ Items

Name of Work
Sl. No. Item Description
1NS Item
2Provision for light fitting at Pumping station complete in all respect
3`RAW WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked ` 4400 LPM x 25.00 m x 42.50 BHP
4COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd. 35mm2 3core
5HT. ALLUMINIUM CABLE: Supply erection testing of standard make XLPE 3 core HT / 11 KV grade ISI marked Stranded compact circular aluminium conductor, conductor screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, innersheath of PVC, galvanised steel flat strip armoured, and overall PVC sheathed cable conforming to is 7098 (part-2) 2011 with up to date amendments for making following connectiona) from G.O switch to metering equipment . b) from metering equipment to transformer complete in all respect. Make: Indian Cables Ltd./ Polycab / RR Cables / CAPP / Finolex / Havells / Gloster / Universal / Fort Gloster Industries Ltd./ Indian Cable Co. / Asian Cables Corporation Ltd. 35 Sqmm size
6LT CABLE ALLUMINIUM: Supply, erection, testing and commissioning of IS marked 3.5 core Cables, Solid Aluminum conductor up to 10sqmm and balance stranded conductor, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Aluminium wire for single core up to 70sqmm and balance Aluminium strip, Glavanised wire for cables up to2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip) extruded PVC type ST2 Outer sheathed, 650/1100V grade as per IS7098 (Part-1) 1988 with up to date amendments along with all accessories complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd. 70 Sqmm size
7Dismantling old D.I. pipe rising main including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking joints, including stacking of pipes and lead at site within 50 metre lead as per direction of Engineer in-charge: Existing150 mm i/d DI pipe R/W pumping station to W/W
8Panel Boards for Motors Supply, erection, testing and commissioning of wall mounted electrical L.T panel Board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm having following items complete in all respect as per approved NIT. For raw water pump sets for 4400 LPM x 25 Mtr. Head = 2 No. a) Main switch 100 Amp 1 No. (LandT, Siemens, ABB) b) Volt Mtr. 100x100mm range 0 to 500 volt 1 No. (AE/KAPPA?LandT) c) Amp.mtr. 100x100mm range 0 to 100 Amp. 1 No. (AE/KAPPA/LandT) d) CT 100/1 No. (AE/KAPPA/LandT) e) VSS 1 No. and ASS 1 No. each of approved make f) SPP 1 No. approved make g) Motor starter , star delta 1 No. for 4400 LPM x 25 Mtr. head motor (LandT, Siemens, ABB) h) Capacity of suitable capacity i) Indicating Lamp- j) Change over switch Amp
9Operation and Maintenance for complete scope of work mentioned in the DNIT including existing Boosting Station (Disinfection material supplied by PHED) as per schedule-IV for a period of5 year after 12 month during defect liability period and 03 Months trial run will be charged to the A/Mtc. estimate complete in all respect as per approved NIT. (i) Operation and Maintenance during defect liability period (Operation only) after 3 month trial run.
10(ii) Operation and Maintenance during 1st year after defect liability period.
11Operation and maintenance during 2nd year
12Operation and maintenance during 3rd year
13Operation and maintenance during 4th year
14Operation and maintenance during 5th year