Delhi Development Authority-DDA has published Tender For Devlopment Of Golf Course And Golf Facilities At Sector-24, Dwarka. Sub Head : Supply, Installation, Testing And Commissioning Key Telephone And Data Networking System At Dwarka Golf Course Sector-24.. Submission Date for this Tender is 09-11-2023. Fixed Phones Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 23-Oct-2023 | Corrigendum-1 | Other | 30-10-2023 |
2 | 30-Oct-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 04-11-2023 |
3 | 04-Nov-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 07-11-2023 |
4 | 07-Nov-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-11-2023 |
Sl. No. | Item Description |
1 | Supply & Installation of 6x32 Digital Key Telephone System for 6 P&T lines, & 32 extension, expandable up to 64 extensions having CLI facility with system connecting cable from Exchange to DP Box etc. i/c testing complete etc as required. |
2 | Supply & Installation of Digital 24 Keys Programmable Key Telephone with Display, CLI, Speaker, hand free facility i/c connection, testing etc. i/c testing complete etc as required. |
3 | Supplying & Installation of the Push Button Telephone having following features including testing, commissioning etc. complete as required:(a) Calller ID display (b) Redial(c) Flash |
4 | Supply, installation of MDF box for following pairs with standard metallic enclosure with locking arrangement consisting Krone make 2/10 Connection/disconnection moduleincluding connection, interconnection testing, commissioning etc. complete as as required.a)100 Pair |
5 | b)10 Pair |
6 | Supplying & installation of150VA C.V.T. for EPABX system i/c testing etc. complete as required. |
7 | Supplying & installation of12V, 7AH battery inBattery Bank (24 Volt 7 A.H.) for EPABX system including terminals for battery backup for 30 Minutes i/c testing etc. complete as required. |
8 | Supplying & installation of Telephone Patch Cord i/c testing etc. complete as required. |
9 | Supply, Installation and testing of 24 port managed switch with 24/10/100/1000BASE-T Ports, 4x Combo 10/100/1000BASE-T/SFP Ports, Full/half duplex for 10/100 Mbps speeds; Full duplex for Gigabit speed, Auto or configurable MDI/MDIX Switching bandwidth 56 Gbps, 8K MAC Address Table complete etc as required. |
10 | Supply, Installation, Testing and commissioning of 16 port PoE 1000 Mbps managed switch with 2 SFP Ports 16/10/100/1000BASE-T Ports, 2x SFP Ports, Full/half duplex for 10/100 Mbps speeds; Full duplex for Gigabit speed, Auto or configurable MDI/MDIX Switching bandwidth 36 Gbps, 8K MAC Address Table complete etc as required. |
11 | Supply, Installation, and testing of 8 port PoE switch with 2 SFP Ports 8/10/100/1000BASE-T Ports, 2x SFP Ports, Full/half duplex for 10/100 Mbps speeds; Full duplex for Gigabit speed, Auto or configurable MDI/MDIX Switching bandwidth 20 Gbps, 8K MAC Address Table complete etc as required. |
12 | Supply & Installation of following size of Rack with PDU, Fan, Hardware accessories etc. i/c testing complete etc as required.a)12U Rack (Indoor) |
13 | b)6U Rack (Indoor) |
14 | b)6U Rack (Outdoor) |
15 | Supply & Installation of Cat6 UTP loaded 24 Port Patch Panel: SPCC, 1.5mm thickness with Black (RAL 9005) color painted, RJ45 Jack, Compatible with both 110& Krone punch down tools, Six Port RJ45 modules applied,of with necessary accessories etc. i/c testing complete etc as required. |
16 | Supply & Installation of LIU loaded following Port with necessary accessories etc. i/c testing complete etc as required.A)24 Port LIU |
17 | B)12 Port LIU |
18 | A)6 Port LIU |
19 | Supply & Installation of Optical Fibre Patch Cord SM LC to LC Fibre Duplex Patch Cord 3Mtr, i/c testing complete etc as required. |
20 | Supply & Installation of Gigabit interface Converter Module single mode, Transmitter and Receiver for Fibre Cable, complete as per specification attached etc i/c testing complete etc as required. |
21 | Supply & Installation of Wall and ceiling mountable Indoor Wireless AC Access Points Dual-Band AC1200, F/W ver. 2.0, 3 x internal dual-band antennas, Supports 802.3at Power over Ethernet for remote installation, High-Performance Connectivity-IEEE 802.11ac Wave 2 wireless1, Up to 1750 Mbps1 speed, Gigabit PoE-capable LAN port, Multiple Operation Modes-Access Point, Wireless Distribution System (WDS), WDS with AP, Wireless Client, Data Signal Rate-2.4 GHz: Up to 450 Mbps, 5 GHz: Up to 1300 Mbps, Security-WEP 64/128-bit encryption etc i/c testing complete etc as required. |
22 | Supplying, Installation & testing of CAT 6 I/O with necessary accessories including complete etc as required |
23 | Supplying, Installation & testing of Dual Face Plate with necessary accessories including complete etc as required |
24 | Supplying of following size HDPE pipe ISI marked along with all accessories etc. complete with fitting and cutting, jointing etc. in the existing trench, complete as required.a)32 mm dia |
25 | Supplying and laying of following pair of 0.5 mm dia PVC insulated annealed copper conductor, PVC armored telephone cable in the existing HDPE pipe/fixing on surface etc completeas required. a) 10 pair |
26 | b) 5pair |
27 | Supplying of UTP 4 pair CAT 6 LAN armoured Cable with accessories i/c connection & testing etc. complete as required. |
28 | Supply & drawing of 06F (core) Single Mode Multi TubeOptical Fibre armoured cablein the existing HDPE pipe i/c connection, testing etc. as required. |
29 | Supply of 2 x 2.5 sqmm copper conductor PVC armoured XLPE cable of 1.1 K.V grade including testing etc. as required. |
30 | Supplying and fixing of following size of medium class PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR2022_1.21.2)a)25 mm |
31 | b)32 mm(DSR2022_1.21.3) |
32 | Supplying and drawing following pair of 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required. (DSR2022_1.18.2)a) 2 pair |
33 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required. (DSR2022_1.24.6) a) Telephone socket outlet |
34 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.(DSR202_1.53.1) a)1 run of cable |
35 | Laying of one number PVC insulated and PVC sheathed XLP power cable of 1.1 K.V grade of following size direct in ground including excavation and refilling the trench etc as required but excluding cushioning and protective covering etc. as required. (DSR2022_7.3.1) |
36 | Supplying, Installation & testing of 1 K.V.A. On-Line UPS for 30 minutes Battery Backup consisting with suitable size battery with accessories i/c testing etc. complete as required. |
37 | Supplying, Installation & testing of 42 AH sealed maintenance free battery for the existing On-Line UPS for 30 minutes Battery Backup with accessories etc. complete as required. |
38 | Supplying & fixing of battery trolly for existing (UPS) & Batteryi/c testing etc. as required. |