Tender For Procurement Of Equipments For Nishtha Testing Laboratory Mpmkvvcl Bhopal
Tender Overview
Project Description
Procurement Of Equipments For Nishtha Testing Laboratory Mpmkvvcl Bhopal , Temperature Scanner 2 Channel With 2 No. Rtds, Communicable With Pc / Usb Port, Pc Software And Accuracy Less Than 1% As Per Specification Of Masibus , Temperature Scanner 8 Channel With 8 No. Rtds, Communicable With Pc / Usb Port, Pc Software And Accuracy Less Than 1% As Per Specification Of Masibus , Rotary Frequency Converter ( M.G. Set ) ( Specification:- 1. Ac Generator:- 20 Kva, 0-866 V, 13.3A, 150Hz, 3Ph, 1500 Rpm, Separately Excited, 2. Ac Motor: Reputed Make 9.3 Kw, Sq. Cage Induction Motor. 415, 50Hz, 3Ph, 1500 Rpm ( Approx ) Arrangement: Both The Above Machines Will Be Mounted On A Common Base Plate And Coupled To Each Other Through Flexible Coupling. , Digital Micro Ohm Meter Of Range 1 Milli Ohm To 2 K Ohm With Accuracy 0.05%, Communicable With Pc / Usb Port, Pc Software As Per Specification Rotary Frequency Converter Will Be Mounted On Anti Vibration ) , Dc High Voltage Breakdown Tester Of 10 Kv With Accuracy Class Less Than 3% As Per Specification , Insulator Of 22 Kv 220 Mm Long, 70 Mm Dia As Per Specification , Earth Resistance Tester ( Range- 0, 10Ohm, 100 Ohm ) , Megger Insulation Tester ( Digital 1±5% 500Vdc-5Kv Upto 100 Giga , Constant Temperature Conditioning Chamber With Dual Display Microprocessor Based Pid Temp. Controller With Pt-100 Sensor ( Capacity-200L, Temperature Range- 5°C To 50 °C, Humidity-10%Rh To 90%Rh, Accuracy-+ 0.5°C ) , Constant Temperature Water Bath With Dual Display Microprocessor Based Pid Temp. Controller With Pt-100 Sensor ( Capacity- 1000 Ltr, Temperature Range- 5°C To 99 °C, Accuracy- +0.5°C ) , Laser Vernier Caliper With Digital Display For Hot Set Oven ( Range- 0 Mm To 150 Mm, Least Count-0.01 Mm Accuracy ±0.01% )
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Nov-2023 | Corrigendum II | Date | 28-Nov-2023 |
| 2 | 29-Nov-2023 | Corrigendum III | Date | 05-Dec-2023 |
| 3 | 06-Dec-2023 | Corrigendum IV | Date | 12-Dec-2023 |
| 4 | 13-Dec-2023 | Corrigendum-V | Date | 19-Dec-2023 |
| 5 | 07-Nov-2023 | Corrigendum I | Date | 20-Nov-2023 |
| 6 | 19-Dec-2023 | Corrigendum VI | Date | 26-Dec-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | Temperature Scanner 2 Channel with 2 no. RTDs, communicable with PC/ USB Port, PC Software and Accuracy less than 1% as per specification of Masibus |
| 2 | Temperature Scanner 8 Channel with 8 no. RTDs, communicable with PC/ USB Port, PC Software and Accuracy less than 1% as per specification of Masibus |
| 3 | Rotary Frequency Converter (M.G. Set) (Specification:- 1. AC Generator:- 20 KVA, 0-866 V,13.3A, 150Hz, 3Ph, 1500 RPM,separately excited, 2. AC Motor: Reputed make 9.3 kW, sq. cage induction motor. 415, 50Hz,3Ph,1500 RPM (Approx) Arrangement: Both the above machines will be mounted on a common base plate and coupled to each other through flexible coupling. |
| 4 | Digital Micro ohm meter of range 1 milli ohm to 2 K ohm with Accuracy 0.05%, communicable with PC/ USB Port, PC Software as per specification Rotary Frequency Converter will be mounted on Anti Vibration) |
| 5 | DC High Voltage Breakdown Tester of 10 KV with accuracy class less than 3% as per specification |
| 6 | Insulator of 22 KV 220 mm long, 70 mm dia as per specification |
| 7 | Earth Resistance Tester ( Range- 0, 10ohm, 100 ohm) |
| 8 | Megger Insulation Tester (Digital 1±5% 500VDC-5kV upto 100 Giga |
| 9 | Constant Temperature conditioning chamber with dual display microprocessor based PID Temp. Controller with PT-100 Sensor (Capacity-200L, Temperature Range- 5°C to 50 °C, Humidity-10%RH to 90%RH, Accuracy-+ 0.5°C) |
| 10 | Constant Temperature Water bath with dual display microprocessor based PID Temp. Controller with PT-100 Sensor (Capacity- 1000 Ltr, Temperature Range- 5°C to 99 °C, Accuracy- +0.5°C) |
| 11 | Laser vernier caliper with digital display for hot set oven (Range- 0 mm to 150 mm, Least count-0.01 mm Accuracy ±0.01% ) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-5 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-6 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender