Tender For Special Repair, diphu-Nagaland

Assam Rifles-AR has published Tender For Special Repair. Submission Date for this Tender is 08-11-2023. Control Panel Tenders in diphu Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

40294512
Tender For Special Repair
Open Tender
Indian
Nagaland
diphu
08-11-2023

Tender Details

Special Repair Special Repair Of Filtration System Of Pump Houses Including Replacement Of Filter Media Multiport Valves Distribution System, Resuscitation Of Bore Well, Change Of Panels And Allied Services For Artc S At Diphu, Amc Including Replacement And Maint

Key Value

Document Fees
INR 1500 /-
EMD
INR 167500.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: (a) Special repair of filtration system of pump houses including replacement of filter media, multiport valves, distribution system, resuscitation of bore well, change of panels and allied services for ARTC at Diphu. ARTC&S at Shokhuvi. (b) Special repair and AMC incl replacement and maint of filtration plant and pipe line works of swimming pool of ARTC & S at Shokhuvi. (c)Replacement of Genr Distr Panel Board and Ancillary works at ARCH at Shokhuvi.
Sl. No. Item Description
1JOB 1 Special repair of filtration system of pump houses including replacement of filter media, multiport valves, distribution system, resuscitation of bore well, change of panels and allied services for ARTC at Diphu. ARTC&S at Shokhuvi Excavating trenches of required width for pipes cables etc including excavation for sockets, depth upto 1.5 m incl getting out the excavated material , returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layers by ramming, watering etc stacking serviceable material for measurement and disposal of unserviceable materials as directed within a lead of 50m pipes, cables etc not exceeding 80mm dia.
2Supply and lay pipe galvanized, “ Heavy class” including fittings 100mm (4”) dia.
3Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc of 80mm dia.
4Supply and fixing GI flange suitable for fitting the pipes including nut bolts and gaskets complete
5Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc of 80mm dia.
6Supply and fixing GI flange suitable for fitting the pipes including nut bolts and gaskets complete
7Supply and fix valves, sluice, flanged of class IPN 16 100mm (4”) dia.
8JOB 2Special repair and AMC incl replacement and maint of filtration plant and pipe line works of swimming pool of ARTC & S at Shokhuvi M/L dismantling and taking out filter media from frp vessel and disposal of same to 50 mtr distance all as specified and directed at site (from 3x vessels)
9M/L overhauling of filtration unit by replacement of following items as listed below :- (a)Gravels & pebbles of approved quality- 3500 kgs
10(b) Quartz sand of approved quality- 12000 kgs
11Replacement of pipes and fittings and accessories (UPVC pipe and fitting 6-10 Kgs/sqcm of Finolex/supreme/astral)(a) UPVC flange 140mm dia
12(b) UPVC falnge adapter 140mm dia
13(c) UPVC falnge adapter 110mm dia
14(d) UPVC falnge110mm dia
15(e) Butterfly valve 140 mm dia (Make : Astral/Equivalent)
16(f) Wafer type check valve 110 mm (Make : Astral/equivalent)
17(g)Header pipe repairing complete
18(h)Curved brush (as per sample)
19(j) Deep leaf net
20(k) Astral flexible hose pipe 50mm dia as per sample (Make : Astral) (Length of pipe 15 Mtrs)
21CHEMICALS (a) Soda Ash light (NIRMA)
22(b) Poly Aluminium Chloride (PAC)
23(c ) Copper sulphate 500 Gms Pkts
24(d) Trichloroscynuric acid (5-8) mesh
25Maint and operation of swimming pool 08 hours per day in one shift by back washing of filter unit complete , maint of PAR (parabolic Aluminized Reflector) lights, pool cleaning, assistance for suction sweeping etc complete all as per site requirement and as directed by Engr-in-charge.
26JOB 3 SReplacement of Genr Distr Panel Board and Ancillary works at ARCH at Shokhuvi Dismantling and taking out old Unsv panel board from Genr Room incl disconnecting of feeders from DG set and deposited to store yard of ARCH.
27Supply, installation, testing and commissioning complete 800 amps DG set panel board made out of 2mm thick CRCA sheet steel, outdoor front fascia, powder coated for long lasting finish cubical type suitable cable entry provision including of all necessary electrical protection including aluminum bus bar comprising the following :- ( Panel size : 3.65 mtr(l)x1.85mtr (ht) x0.45mm width).(a) MCCB 4 pole, 50 KA 800 Amps breaking capacity with fixed type thermal magnetic protection complete including spreader link, extended rotary handle, phase indicating lamps, MCB SP 16 Amps for control protection including digital multifunction ,meter complete with CT coil with rotary handle and phase indictor complete – 01 No (MCCB : SIEMEN/L&T/SCHNEIDER). (b) MCCB 4 pole, 35 KA 400 Amps breaking capacity with fixed type thermal magnetic protection complete including spreader link, extended rotary handle, phase indicating lamps, MCB SP 16 Amps for control protection including digital multifunction ,meter complete with CT coil with rotary handle and phase indictor complete – 01 No (MCCB : SIEMEN/L&T/SCHNEIDER).(c) MCCB 4 pole, 35 KA 200 Amps breaking capacity with fixed type thermal magnetic protection complete including spreader link, extended rotary handle, phase indicating lamps, MCB SP 16 Amps for control protection including digital multifunction ,meter complete with CT coil with rotary handle and phase indictor complete – 01 No (MCCB : SIEMEN/L&T/SCHNEIDER). (d) MCCB 4 pole, 35 KA 125 Amps breaking capacity with fixed type thermal magnetic protection complete including spreader link, extended rotary handle, phase indicating lamps, MCB SP 16 Amps for control protection including digital multifunction ,meter complete with CT coil with rotary handle and phase indictor complete – 01 No (MCCB : SIEMEN/L&T/SCHNEIDER).(e) MCCB 4 pole, 35 KA 100 Amps breaking capacity with fixed type thermal magnetic protection complete including spreader link, extended rotary handle, phase indicating lamps, MCB SP 16 Amps for control protection including digital multifunction ,meter complete with CT coil with rotary handle and phase indictor complete – 01 No (MCCB : SIEMEN/L&T/SCHNEIDER). (f) MCCB 4 pole, 35 KA 125 Amps breaking capacity with fixed type thermal magnetic protection complete including spreader link, extended rotary handle, phase indicating lamps, MCB SP 16 Amps for control protection including digital multifunction ,meter complete with CT coil with rotary handle and phase indictor complete – 05 No (MCCB : SIEMEN/L&T/SCHNEIDER). Note :- Load Bearing member will be Fabricated from 2 mm thick CRCA MS sheets, Inside partitions are made with 1.6mm CRCA MS sheet steel and Cable Gland plate with 3mm CRCA MS Sheet steel. The panel shall have wall and floor grouting system. The panel shall have minimum200 mm bottom stand (if necessary for bottom cable entry). The panel operation height shall not exceed 1800 mm. structural reinforcement with suitable angle/channel/T/flat sections including lifting hooks and GI earth strip of required size with 2 nos earthing terminals. Painting :- Powder coated paint finish of approved shade over metal surface cleaned and treated with all anticorrosive process and seven tank process before painting, with 2 coats of zinc chromate primer upto 75 micron thickness and colour RAL7035 of enameled paint as per as per specifications.. Labeling:- All Panels shall be duly metal labeled with scheme diagram and Danger mark with 415V AC operation. Cable Entry:- The panel shall have a provision of cable entry at the bottom and top as per site requirement. Busbar:- Busbar shall be sized with current density of Amperage 1A/sq.mm for Aluminum Busbars .Heat Shrinkable Color Coded PVC Sleeves for all Busbars, minimum bus bar gap of 32mm shall be maintained, busbar shall be of E91E Grade for Al.. MCB Connectivity:-MCB shall be connected using FR cables of proper rating from Vertical busbars.
28M/L dismantling and taking out unsv XLPE cable from existing connection for replacement upto 240 sqmm cable complete.
29Supply and laying one number PVC insulated sheathed/XLPE power cable of 1.1KV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc as required of size 95 sqmm (Make : Havells/Gloster/Polycab/KEI) (for 63 KVA Gen Set Connection).
30Supply and laying one number PVC insulated sheathed/XLPE power cable of 1.1KV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc as required of size 120 sqmm (Make : Havells/Gloster/Polycab/KEI) (for 125 KVA Gen Set Connection).
31Supply and laying one number PVC insulated sheathed/XLPE power cable of 1.1KV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc as required of size 400 sqmm (Make : Havells/Gloster/Polycab/KEI) (for 250 KVA Gen Set Connection).
32Earthing of machinery/equipment installed at power house/sub station, using 32x6mm galvanized GI strip and galvanized plate 600x600x6mm as earth electrode (set of 2).
33Providing and fixing 25mmx5mm GI strip on surface or in recess for connections etc as required.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail