Tender For Repairs/Maint Of Chlorination Plant And Pump Set Dozer, Various Capacity Pump Sets, Water Supply Distribution Lines Ci/Di/Gi And Connected Works At Singpur And Tech Area At Af Station Gwalior, gwalior-Madhya Pradesh

Military Engineer Services-MES has published Tender For Repairs/Maint Of Chlorination Plant And Pump Set Dozer, Various Capacity Pump Sets, Water Supply Distribution Lines Ci/Di/Gi And Connected Works At Singpur And Tech Area At Af Station Gwalior. Submission Date for this Tender is 16-11-2023. Submersible Pump Tenders in gwalior Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40293900
Corrigendum : Tender For Repairs/Maint Of Chlorination Plant And Pump Set Dozer, Various Capacity Pump Sets, Water Supply Distribution Lines Ci/Di/Gi And Connected Works At Singpur And Tech Area At Af Station Gwalior
Open Tender
Indian
Madhya Pradesh
gwalior
16-11-2023

Tender Details

Repairs/Maint Of Chlorination Plant And Pump Set Dozer, Various Capacity Pump Sets, Water Supply Distribution Lines Ci/Di/Gi And Connected Works At Singpur And Tech Area At Af Station Gwalior

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-

BOQ Items

Name of Work: REPAIRS/MAINT OF CHLORINATION PLANT AND PUMP SET DOZER, VARIOUS CAPACITY PUMP SETS, WATER SUPPLY DISTRIBUTION LINES CI/DI/GI AND CONNECTED WORKS AT SINGPUR AND TECH AREA AT AF STATION GWALIOR
Sl. No. Item Description
1Disconnecting the existing non functional submersible pump set from supply net work. dismantling existing CI bend from non return valve, removing and lifting out submersible pump set of any description and capacityandin any position, alongwith existing column pipe 80/50mm dia and existing submersible cable of any size from the bore well(approximately 50 mtr depth of pump set from GL) complete and lowering after repair with all accessories including testing all as specified and directed. NOTE:1. Contractor shall take proper precautions while lifting out and removing motor/pump set from bore well so as to avoid any damage to column pipe and submersible cable.All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost.Any items like cable, column pipe, clamps shall be paid separately....... 2 . Any repair to submersible pump & spares etc shall be paid and measured separately under relavant item in this schedule
2Dismantling and strip opening of submersible pump/motor of any description of Capacity up to 20 HPfor reparing /overhauling,fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts (To be paid separately) including minor parts such as washer, "O" Rings, nut bolts and any machining work required re-threading of holes, lock nut etc required for smooth functioing of pump motor and reassembling the pump andmotor, ensuring proper alignment of pump and motor,complete all as directed. Note: - (i) The replacement of defective / unserviceableparts shall be measured and paid separately as “Supply only” under appropriate item of Sch ‘A’ and fixing rate for new items are deemed to include under these item. (ii)Burnt out windings of motor shall be replaced, measured and paidseparately under appropriate item of Sch ‘A’ for rewinding.
3Supply only the following items / parts of AC submersible motor/pump of above mentioned types and capacity complete all as specified and directed:-(a) Upper & lower rubberhousing bush
4Stainless steel rotor sleeve.
5Thrust bearingcomplete set.
6MS Flange with stud.
7Motor base of cast iron.
8Neck Ring .
9Pump Key
10Sim washer
11Segment holder assembly.
12Strainer.
13Oil seal.
14Coupling set with key of stainless steel
15Discharge outlet of cast iron for pump
16Rotor For15to20 HP Submersible motor.
17Stage casing of Cast Iron
18Gun metal body bush.
19Impellar
20Rotor machining,grindingand balancing
21Motor tube boring,machining & reconditioning
22motor lamination setting with material
23Rotor reconditioning
24slote repairing in stator
25Stainless steel distance bush ( Spacer).
26Inlet bracket
27Cable Guard
28Stainless Steel Connection Piece (Adopter Piece)
29Cast iron Suction Housing including studs
30Rotor up to 12.5 HP Submersible motor.
31SS Pump shaft suitable up to 12.5 HP complete all as specified and directed.
32SS Pump shaft suitable for 15 to 20 HP complete all as specified and directed.
33M&L for water proof joint of submersible cable 3 core of any size using fine rubber and M Seal etc complete all as specified anddirected.
34Supply onlyflat copper conductor submersible cable of size 6 Sqmm, 3 core complete including necessary achoring accessies along the columm pipe etc all as specified and directed. Make: - Havells/KEI/Finolx
35Supply onlyflat copper conductor submersible cable of size 4 Sqmm, 3 core complete including necessary achoring accessies along the columm pipe etc all as specified and directed. Make: - Havells/KEI/Finolx
36Supply onlyflat copper conductor submersible cable of size 2.5 Sqmm, 3 core complete including necessary achoring accessies along the columm pipe etc all as specified and directed. Make: - Havells/KEI/Finolx
37Supply only GI socket, heavy duty, seamless, long threaded ISI marked for 80mm bore column pipes all as directed by Engineer-in-Charge.
38Supply only GI socket, heavy duty, seamless, long threaded ISI marked for 50mm bore column pipes all as directed by Engineer-in-Charge.
39Supply only Galvanised iron medium grade 3.00 mtr long 80 mm bore column pipe both ended threaded and long socket complete all as directed.
40Supply onlyGalvanised iron medium grade 3.00 mtr long 50 mm bore column pipe both ended threaded and long socket complete all as directed.
41Taking out and removing old burnt out windings of the submersible electric motors 15to20 HP, 3 Phase, 415 Volts of following capacity and re winding of submersible electric motors with existing size super enamelinsulated, copper winding wire including cleaning the slots with carbon- tetra-chloride solution before re winding includingrepairing of stator including grinding, re condintioning required lamination insulation material etc complete all as specified and directed. Note :- Required transpertaiton from the site to workshop and back is deemed to be included in the quoted rate.
42All as per item No.12 above but submersible electric motor of 10 /12.5 HP
43All as per item No.12 above but submersible electric motor of 5 /7.5 HP
44Repair to stage casing outer & inner diffuser of submersible pump of any description by cutting,balancing, brazing , welding, turning and Grindingcomplete all as specified and directedfor the following capacities of the pumps coupled with submersible motorsof capacity 15 to 20 HP
45All as per item no.15 above but submersible pump capacity upto 5.0 to 12.5 HP
46Cutting out the unserviceable / damaged portion of the 80mm bore GI column pipe of any grade, making new threads to suitable lengths (for providing long threaded socket)for jointing the pipes with old/new pipes to replace the unserviceable length or to increase the length of column pipe specified etc completeall as directed.
47Disconnecting and taking out /lifiting out existing non-functional 2/3 HP capacity submersible/Mono-block centrifugal/Chiloronem plant motor,set of any description and in any position, dismantling and strip opening ofpumps for servicing /overhauling, cleaning, oiling / greasing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts and re-assembling the pump, fixing/lowering, in position, connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge complete all as specified and directed. Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’from item No-51 to 59 and fixing rate for new items are deemed to include under these item. (ii) The rates for above items are deemed to include for transportation of pumps/ motors to and from workshop as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at workshop replacement of necessary unserviceable screws/nuts /bots/washers/ packing etc. (iii)Burnt out windings of motor shall be replaced, measured and paid for separately under appropriate item of Sch ‘A’ for re- winding. (iv) Turning/ polishing of the rotor shaft shall be measured and paid seperately
48Ditto- all as per above but, for capacity 0.25/1.5 HP,single phase, of any make & any discription complete all as specified and as directed.
49Taking out and removing old burnt out windings of the 2 / 3 HP, three phase, 415 Volts, 50 Hz, AC supplyInduction motor of mono blockboosterpump/single phase submersible pumpsets and rewinding of motor with existing size PVC insulated copper conductoras approved by the Engineer-in-charge including cleaning the slots with carbon- tetra-chloride solution before rewinding ,transportation to site, fixing in position & testing on full load complete all as specified and directed.
50All as per item No. 19 here in before but ofcapacity 0.25 / 1.5 HP,Single phase, of any make & any description complete all as specified and as directed.
51Supply onlyCI impeller for multistage booster pump
52Supply only CI impeller for centrifugal pump
53Supply only CI gland bush with pump forbooster pump/centrifugal pump
54Supply only Cast iron gland plate for booster pump / centrifugal pump
55Supply onlyStainless steel main shaft
56Supply only PVC Fan along with fan cover
57Supply only Ball Bearing No 6202for Induction motor & booster pump of any description, any capacity compete all as specified and directed.Make : NBC/SKF / TATA
58Supply only Ball Bearing No 6205for Induction motor & booster pump of any description, any capacity compete all as specified and directed.Make : NBC/SKF / TATA
59Supply onlyBall Bearing No 6206for Induction motor & booster pump of any description, any capacity compete all as specified and directed.Make : NBC/SKF / TATA
60Supply & fixing100/150 mm diaPrassur gage range 150kg/cm
61Supply fabrication & installation out door type MS Cover factory fabricated with 3.00 mm thick CRCA sheet duly painted with two coats of synthic enamelled paint over a coat of red oxide primer of suitable size mounted on MS angle iron of 50X50X6 mm and having 4 legs of 1.00 mtr including grouting in PCC 1:3:6,below ground level of saze 100x100x10cm including 125 Amps MCCB 4 Pole 25 KA Make Legrand DPX Model-01 No and Star dalta Starter cum pump controllerfully automatic in sheet )-01 No including metal enclosure MUG type 3 Phase,415 Volt AC Cat part No MUG 30 (CS 96008)-01 No including connected with copper cable of suitable size all as directed.
62Supply fabrication & installation out door type MS Cover factoryfabricated with 3.00 mm thick CRCA sheet duly painted with two coats of synthic enamelled paint over a cot of red oxide primer of suitable size mounted on MS angle iron of 50X50X6 mm and having 4 legs of 1.00 mtr including grouting in PCC 1:3:6 Below ground Level of size 100x100x10 CM including 100 Amps MCCB 4 Pole 25 KA Make Legrand DPX Model-01 No and Star dalta Starter cum pump controllerfully automatic in sheet )-01 No including metal enclosure MUG type 3 Phase,415 Volt AC Cat part No MUG 20 (SS95975)-01 No including connected with copper cable of suitable size all as directed.
63S & F in repair, star dalta starter fully automatic cum pump controller in sheet matel enclosure type MU-G complete with MCB Amp/Volt meter indicators 3 phase 415 Volts AC 50 Hz Cat part No MUG-30 (CS 96008) of L&T make.
64S & F in repair, star dalta starter fully automatic cum pump controller in sheet matel enclosure type MU-G complete with MCB Amp/Volt meter indicators 3 phase 415 Volts AC 50 HzCat part No MUG 20 (SS95975) of L&T Make.
65Periodical inspection& carryout preventive Maintenance of chlorination system/plant /BP Dozer to make system serviceableall time to maintain proper chlorination, with allchiloronem plant, including dismentling, re-fixing and installation of plants/dozing pump after repairing (Major spare paid separately as supply only) including minor spare parts refitting in same position & testing complete as specified and directed :- (a) 9- squiden pump house (b) ETB PUMP HOUSE (c) BOMBDUMP pump house (d) Logistic Pump House (e) NOR Pump House (f) SOR pump House (g)Tropo/RCPO (h)HQ P/H (I)AFlt pump house (j)C Fltpump house (K) singpur range pump house Note :- (i) Plant shall be made functional within a 48 Hours otherwise a penalty @ Rs 500- per day shall be recovered. (ii) Spare parts shall be measured and paid as supply only. (iii) During repairing period of plant manual system will be arrranged by contractor for maintaining chlorination and cost of it shall be included in quoted rates.
66Supply only 7X pump tubecomplete all as specified and directed.
67Supply only injection check valve 3/8" complete all as specified and directed.
68Supply only weighted suction line strainer 3/8" complete all as specified and directed.
69Supply only 3/8" white suction /discharge tubing .complete all as specified and directed.
70Supply only check valve duckbill only (PK of 5)complete all as specified and directed.
71Supply only connected nut 3/8".complete all as specified and directed.
72Supply onlyconnecting nut 3/8"with adapter (PK of 5)
73Supply only ferrule 1/4"(PK of 24).complete all as specified and directed.
74Supply only Rotor assembly with bearings brackets & tolerance Ringsfor Dosing Pump complete all as specified and directed.
75Supply only COIL 250V, 50 HZ Dosing Pump complete all as specified and directed.
76Supply only ROLLER Assembly for Dosing Pump complete all as specified and directed.
77Supply only Single Head feed rate control with shaft complete for Dosing Pump complete all as specified and directed.
78Supply only PUMPHEAD (FERRULES 1/4"&DUCKBILL INCLUDED) complete for Dosing Pump complete all as specified and directed.
79Supply onlyset of pipe and accessories required for preparation & service tank complete all as specified and directed.
80Supply, installation, testing & commissioning of Reciprocating Chlorine dosing pump(Decrin dosing pump model 96NGQ51) high pressure, single head, gear motored adjustable dosing pump having output of 2 U.S. GPD to 40 U.S. GPD, adjustable high pressure of up to 100 PSI with accessories including lead , tubing, connection nuts, injection check valve, clay weight, ferrule etcall as speacified and directed ,Make : Declibac, or equvlent
81supply onlyAgitator:of capacity120watts, 900 RPM, single phase flange mounted motor with plastic shaft & impeller all as speacified and directed Make : Declibac, or equvlent
82supply onlyPrep aration tank (170 Ltrs FRP )with all accessories, Water inlet line,Outlet with strainer, Drain ,Overflow,Conical bottom for sludge disposal, port whole with cover,Level gage, all as speacified and directed Make : Declibac, or equvlent
83Supply & fixingFRP Service Tank 100 ltr:with all accessories ,Water inlet,Dosing Pump mounting provision on lid / wall ,Overflow, Level Gauge, Inspection Port. all as speacified and directed ,Make : Declibac, or equvlent
84Supply only Complete 230V 50HZ Gear Motor all as specified and directedMake :- Declibac, or equvlent
85Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep, in any type of soil including forming sides and bottom surfaces to required level / slope / gradients etc for taking down/laying of the pipe linescomplete all as specified and directed at site. Note: The disturbed surfaces of roads/paths/plinth etc shall be made good by the contractor to match with the existing surfaces without any extra cost).
86Returning, fillingin, excavated soil in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
87Removing of excavated surplus soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
88Disconnecting and taking down old existing steel tubing and connections of any description/ grade and in any position in trenches/under floors / on walls etc including all fittings/accessories and fixtures such as bends, union,elbow socket etc,and supply and lay GI pipe medium gradeall as directed and specified for the following sizes :- (a) 80 mm bore
89(b) 50 mm bore
90(c) 40 mm bore
91(d) 25 mm bore
92(e) 20 mm bore
93(F) 15 mm bore Note :- Excavation & earth work shall be measured and paid separetely under respective item of Sch "A".
94M & L forISI Marked, gun metal globe/gate valve with iron wheel head, both ends screwed for iron pipe complete all as specified and directed including taking down for following bore of pipes:- (a) 50mm bore
95(b)40mm bore
96(c)25mm bore
97(d)20mm bore
98(e)15mm bore
99M&L for Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed for the sizes :-15mm
100Dismentling of leaked flaged joint and M&L for rubber gasket joints in flanged end cast iron pipes and fittings complete with and including minimum 3 mm thick rubber/fibre gasket and necessary mild steel nuts, bolts & washers all as specified and directed for following sizes:- (a) 150mm bore
101(b)100 mm bore
102(c)80 mm bore
103M&L for cutting of existing CI/GI pipe line in position forinsertion of collars or other fittings including dewatering etc complete all as specified anddirected for the following bore of pipes:- (a)150 mm bore
104(b)100 mm bore
105(c)80 mm bore. Note :S&F of insertion of fittings etc shall be measured & paid for separately under appropriate item of Sch "A").
106M& L for new run lead joint by new lead pig and making new joint by spun yarn and caulking etc all as specified and directed for the following sizes :- (a)150 mm
107(b) 100mm
108(c) 80 mm
109M&L for repairing of leaked lead joint by taking out lead and making lead joint by retrived lead and extra lead required including spun yarn and caucking etc all as specified and directed for the following sizes :- (a)150mm Note :1-leakage shall be made functional within a 48 Hrs otherwise a penalty @ Rs 1000/- per day shall be recovered from the payment due .
110(b)100mm
111(c)80mm
112M& L for repairing of leaked /broken GIpipeincluding necessary cutting threading and Re fixing with new GI Fitting, excavation and earth work, bailingout water etc complete all as specified and directed for the following sizes : Note;1 :S&F of insertion of GI fittings and excavation shall be measured & paid for separately under appropriate item of Sch "A"/BOQ Note :2-leakage shall be made functional within a 48 Hrs otherwise a penalty @ Rs 1000/- per day shall be recovered from the payment due . (a) GI PIPE 80mm bore
113(c) GI pipe50 mm dia
114(d) GI pipe40 mm dia
115(e) GI pipe25 mm dia
116(f) GI pipe20 mm dia
117(h) GI pipe15 mm dia
118Supply only GI umion 50 mm
119Supply only GI umion 40 mm
120Supply only GI umion 25 mm
121Supply only GI umion 20 mm
122Supply onlyGI umion 15 mm
123Supply only nipple 80mm
124Supply only nipple 50mm
125Supply only nipple 40mm
126Supply only nipple 25mm
127Supply only nipple 20mm
128Supply onlynipple 15mm
129Supply only GI Soket 80 mm
130Supply only GI Soket 50 mm
131Supply only GI Soket 40 mm
132Supply only GI Soket 25 mm
133Supply only GI Soket 20 mm
134Supply onlyGI Soket 15 mm
135Supply only GITee 50 mm
136Supply only GITee 40 mm
137Supply only GITee 25 mm
138Supply only GITee 20 mm
139Supply only GITee 15mm
140Supply only GIelbo 50mm
141Supply only GIelbo 40mm
142Supply only GIelbo 25mm
143Supply only GIelbo 20mm
144Supply only GIelbo 15mm
145Supply onlyCI " D" Joint 80 mm
146M&L for construction of brick masonry valve pit / chamber complete with 3mm thick MS sheet cover with locking arrangement of size 1050 mm x 1050 mm x 1050 mm (depth) (internal dimensions) all as shown on CE(AF)/TD/EM/01 Sheet 1/1 dt 16 Mar 1993with and including necessary excavation & earth work in any type of soil complete all as specified and directed.
147All as per item No 94 here-in-beforebut,size 750 mm x 750 mm x 750 mm (depth) (internal dimensions)
148All as per item No 94 here-in-beforebut,size 600 mm x 600 mm x 600 mm (depth) (internal dimensions)
149Taking up or down existing cast iron sluice valves of any description and in any position, removing from site including taking out joints complete all as specified and directed for the following sizes :- (NOTE :Sluice valves other than those dismantled with taking up or down of cast iron pipe lines shall be measured and paid for under this item) (a) 150mm bore
150(b) 100 mm bore
151(c) 80 mm bore
152Supply, installation, fixing, jointing and testing, ISI Marked, cast iron sluice valve of class PN-1.6 conforming to IS-14846 of 2000 both ends flanged with iron wheel head and stainless steel spindle, jointedwith and including jointing material such as rubber or fibre gasket, nuts, bolts washers etc and tested complete all as specified and directed for following bores :- (a) 150mm bore
153(b) 100 mm bore
154(c)80 mm bore
155Taking up or down exiting cast iron non return valves of any description and in any position, removing to stores including taking out joints complete all as specified and directed for the following sizes: -(a)100 mm bore
156(b) 80 mm Bore
157Supply and fixing, 100mm bore, ISI Marked, cast iron non return valve, both ends flanged jointed and tested complete all as specified and directed. MakeKirlosker/Upadhaya/Kajriwal as approved by GE.
158Supply and fixing, 80mm bore, ISI Marked, cast iron non return valve, both ends flanged jointed and tested complete all as specified and directed. MakeKirlosker/Upadhaya/Kajriwal as approved by GE.
159Disconnecting and taking down old existing cast iron/DIpipe line/ water main and connections of any description/ grade including lead if any and in any position in trenches/under floors / etc including all fittings/accessories and fixtures such as bends, union,elbow socket etc, all as directed and specified for the following sizes :- (a)150 mm bore
160(b) 100 mm bore
161(c) 80 mm bore
162Supplying ,laying, jointing & testing in trenches ductile iron pipes with spigot and socketed ends centrifugally cast (spun cast) class K-9 suitable for Titen jointscomplete all as specified and directed for the following size:- (a)150 mm bore
163(b)100 mm bore
164(c)80 mm bore NOTE :- Earth work,and CI specials/ fittings of the pipes shall be measured and paid for separately under respective item of Schedule `A".
165Titen joint suitable for K-9 Ductileiron pipe complete all as specifiedand directed by Engineer-in-Charge for the following size:- (a)150 mm bore
166(b)100 mm bore
167(c)80 mm bore
168supply & fixing in Replacement of PVC float valve complete all as specified and directed for the following sizes: (a) 40 mmbore
169(b) 25mm bore
170(c) 20 mm bore
171(c) 15 mm bore
172Supplying, fixing, jointing and testingcast iron/ductile iron specials/fittings such as bend, tee, socket, color, Reducer, Tail Pieces etc. suitable for spigot and socketed/ flanged end pipes of 150 mm bore and below complete all as specified and directed by Engineer-in-Charge.
173M&L for fabricating and fixing of pipe line MS clamp of flat iron made to shape alongwith nuts, bolt washers etc suitable for folloing pipe line all as specified and directed for stopping leaking of pipe lines of any description and in any position. Clamps shall be made toshape and size as approved, tightened with suitable nuts, bolts washers as directed. (a) 150mm bore
174(b) 100 mm bore
175(c) 80 mm bore.
176(d) 50 mm bore
177(e) 40 mm bore. Note :S&F of insertion of fittings etc shall be measured & paid for separately under appropriate item of Sch "A").
178Cutting of Road/floor by electric hammer/manual, for dismaintling/laying ofpipe line, complete all as specified and directed,
179M & L for cement plastering15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finish even and fair complete all as specified and directed.
180M & L for cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
181Supply and fixing Stop valves PTMT any colour screwed down, high pressure screwed both ends for iron pipe complete all as specified and directed for the following size :- (a) 15mm
182(b) 20mm
183M & Lfor carrying out chemical analysis of water as per IS- 10500- 2012from any govt Approved lab/Institute after collecting the water sample(SIXTEN NO) in separate suitable container as prescribed by the labs from following each pump house / borewell complete all as specified and directed by Engr-in-Charge :- (a) 9 Sqn Pump House, (b) ETB Pump House, (c) BOMBDUMP pump house, (d) Logistic Pump House, (e) NOR Pump House, (f) SOR pump House, (g) Tech Flt Pump House, (h) 06 Ens bore well, (j) CSD Old bore well, (k) BPCL bore well, (l) 1 Sqn bore well,(m) ‘A’ Flt pump House, (n) Tropo Pump House, (o) CCR new Pump House, (p) Singpur range pump House, (q) HQ Pump house
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail