Tender For Provision Of Works Services For Sdr And Crash Bell At New Atc At 8 Fbsu Af Station Awantipur, Srinagar-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Provision Of Works Services For Sdr And Crash Bell At New Atc At 8 Fbsu Af Station Awantipur. Submission Date for this Tender is 21-11-2023. Air Conditioner Tenders in Srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

40293623
Corrigendum : Tender For Provision Of Works Services For Sdr And Crash Bell At New Atc At 8 Fbsu Af Station Awantipur
Open Tender
Indian
Jammu And Kashmir
Srinagar
21-11-2023

Tender Details

Tender For Provision Of Works Services For Sdr And Crash Bell At New Atc At 8 Fbsu Af Station Awantipur; 1 Supply And Install Hi Wall Split Type Air Conditioner Inverter Type Units Indoor / Outdoor Unit Complete With Heating And Cooling Function With Cordless Remote Control Unit And With In Built Air Ioniser And Plasma Filter For Better Air Quality With 4 Star Rating Of Capacity 1.5 Tr Split Unit Air Conditioner Electric Driven Single Phase Copper Condensor, Complete All As Specified And Directed. 2 Supply And Fix Copper Tubing 1 / 4 Inches Dia Suitable For Ac Ducting Complete With Brazing And Jointing, Complete All As Specified And Directed. 3 Supply And Fix Copper Tubing 1 / 2 Inches Dia Suitable For Ac Ducting Complete With Brazing And Jointing, Complete All As Specified And Directed. 4 Supply And Fix Pvc Rigid Drain Pipe 20 Mm Dia Along With Connecting Accessories And Fixing Saddle At Every 1M, Complete All As Specified And Directed. 5 Supply And Fix Copper Cable 4 Sqmm 3 Core With Necessary Bottle Lugs And Connecting, Complete All As Specified And Directed. 6 M&L Sub Main Wiring With Multistranded Frls Copper Conductor Cable Pvc Sheathed In And Including Pvc Casing Capingwith Two Runs Of 4.0 Sqmm And One Run Of 4.0 Sqmm Frls Copper Conductor As Earth Wire And Connected To Earth Dolly, Completeall As Specified And As Directed. 7 Suuply & Fix Voltage Stabilizer 4 Kva Capacity, Copper Wound Suitable For Input Voltage 90 V To 270 V & Output Voltage Stabilized 220 V, Copper Wound Single Phase 50 Hz Along With Time Delay Relay Along With Lcd Display Complete With All Mounting Accessories, Completeall As Specified And As Directed. 8 S&F Sheet Metal Enclosure Double Door Type For Dbs ( When Mcb To Be Used ) 8 Way 240 Volts With 200 Amps Rated Busbar And Neutral Link, Completeall As Specified And As Directed. 9 S&F Single Pole & Neutral Sheet Metal Enclosure With A Two Pin And Earth Plug And Socket Complete With One Single Pole Mcb 20 Amps, Complete All As Specified And As Directed 10 S & F Mcb C Series Single Pole, 240 V5 To 32 Breaking Capacity 10 Ka Amps, Completeall As Specified And As Directed. 11 S & F Mcb C Series Single Pole & Neutral, 240 V 40 Amps Breaking Capacity 10 Ka Amps, Completeall As Specified And As Directed. 12 M&L For Earthing Complete With Gi Earth Plate 600 X 600 X 6 Mm Thick Buried Directly In Ground ( Earth Pit Not Less That 2.25Mtr Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5Mr Below Normal Ground Levelconnected To Galvanised Earth Lead Wire 4.0Mm By Means Of Brazing After Tighten By Bolts, Nuts, Check Nuts And Washersfrom Earth Pit To Test Point With Protection Gi Pipe Of Size 25 Mm Dia Light Grade With Watering Pipe 20 Mm Diaand Providing Masonry Enclosureearth Pit In Pcc 1:2:4 Type B0 Using 12 Mm Graded Crushed Stone Aggregate, Rcc Cover, Funnel, Wire Mesh Including Necessary Excavation And Earth Work In Any Type Of Soil, Returning Filling In And Removal Of Surplus Soil, Completeall As Specified And As Directed. Note: Gi Wire Included In The Quoted Rate From Earth Pit To Test Point 13 Supply And Laying Cable Xlpe Insulated Screened Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 70 Sqmm 3.5 Core, Completeall As Specified And As Directed. 14 Supply And Fix Servo Controlled Voltage Stabilizer For Automatic Operation, Three Phase, Naturally Oil Cooled, Indoor Type, Suitable For Unbalanced Type Load & Designed For Input Variation Between 360 V To 480 V With Output Voltage Stabilized At 415 With Accuracy ± 2.5% And Speed Of Correction 8 Volts Per Second And Of Capacity 1 X 25 Kva Alongwith Protection For Short Circuit / Overload High Low Voltage Cut Off By Pass Arrangement In Case Of Emergency With Efficiency More Than 95% Along With Single Phase Sequence Change Phase Fail Protection, Completeall As Specified And As Directed. 15 Supply, Installation, Testing & Commisioning In Replacement Of Factory Made ( Cpri Test Certified Manufacturer ) Lt Feeder Pillar Box Of Minimum Size 40Cm ( Height ) X 30Cm ( Width ) X 30 Cm ( Depth ) , Outdoor Type, Floor Mounted, Double Door, Cubical Compartmentalized Type Suitable For 415 Volts, 3 Phase, 4 Wire, 50 Hz Supply System All As Specified And Directed Having Busbar Chamber With Insulated Aluminium Busbar 200 Amps Rating ( 100% Neutral ) Installed On Porcelain Insulators. The Panel Shall Be Dust And Vermin Proof Made Of 3 Mm ( Outer ) & 2 Mm ( Inner Compartment Door ) Crca Sheet Duly Powder Coated, Panel Mounted On Angle Iron 40X40x6 Mm Frame Having 4 Nos Legs 45 Cm Long Of 40X40x6 Mm Angle Iron, 15 Cm Grouted In Pcc Of Ratio 1:2:4 And 30 Cm Clear Space Front Ground Level. Front & Back Opening Type With Aprons For Cable Entry With Locking Arrangement Including Internal Wiring With Pvc Insulated Multistranded Copper Conductor Cables Of Suitable Size, Thimbling And Cable Entry Boxes With Cable Glands. The Scope Of The Work Also Includes Supply And Fixing The Following:-Incoming:- ( A ) Mccb 63 Amps, 25 Ka Rupturing Capacity, 4 Pole, 415 Volts, 50 Hz, Adjustable Thermal Fixed Magnetic Release Type - 01 No. ( B ) Voltmeter Digital Type 0-500 Volts, Flush Type With 3 Way Rotary Selector Switch -01 No ( C ) Ammeter Digital Type 0-100 Amps, Flush Type With 3 Way Rotary Selector Switch And 3 Nos Cts Of Ratio 100 / 5 Amps - 01 No ( D ) Indicating Lamp ( Led Type ) Ryb - 01 Set Of Threeoutgoing:- ( A ) Mcbtpn 63 Amps, 25 Ka Rupturing Capacity, 4 Pole -03 No. 16 M&L For Earthing Complete With Gi Earth Plate 600 X 600 X 6 Mm Thick Buried Directly In Ground ( Earth Pit Not Less That 2.25Mtr Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Levelconnected To32x6 Mm Gi Strip As Earthing Lead By Means Of Brazing After Tighten By Bolts, Nuts, Check Nuts And Washersfrom Earth Pit To Test Point With Protection Gi Pipe Of Size 50Mm Dia Light Grade And Providing Masonry Enclosureincluding Watering Gi Pipe ( Medium Grade ) 20 Mm Bore From Bottom Of Earth Pit To Top Of Electrode And 20 Mm Gi Pipe Light Grade For Earth Strip Protection Complete With Earth Pit In Pcc 1:2:4 Type B0 Using 12 Mm Graded Crushed Stone Aggregate, Rcc Cover, Funnel, Wire Mesh Including Necessary Excavation And Earth Work In Any Type Of Soil, Returning Filling In And Removal Of Surplus Soil, Complete All As Specified And As Directed. Note: Gi Strip 7.5 Mtr Included In The Quoted Rate From Earth Pit To Test Point 17 M&L For Excavation In Trenches In Soft / Loose Soil Not Exceeding 1.5 M In Depth And Width And Getting Out, Complete All As Specified And As Directed. 18 M&L For Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm, Complete All As Specified And As Directed. 19 M&L For Removal Of Excess Soil From Site N Exc. 50M And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point, Completeall As Specified And As Directed. 20 M&L For Sand Cushioning ( Dry Sand ) To Underground Cable For Cable Protectionlaid In Trenches / In Existingcable Ducts, Complete All As Specified And As Directed.Note: For Payment Point Of View, Compacted Thickness Of Sand Shall Be Measured. 21 M&L For Brick Laying With Subclass B Bricks Well Burnt, Laid Dry Flat In Trenches For Protection Of Cable Over Lt Cable, Complete All As Specified And As Directed. 22 Supply, Install, Testing & Commissioning Horizontal Double Mounting Siren Single Phase 220 / 250 V 6000 Rpm 0.5 Hp 50Hz, Ac Including Mounting Complete With All Accessories. Make- Kheraj Or As Equivalent 23 Supply, Install, Testing & Commissioning Electric Gong Call Bell Single Phase 220 V, Ac Including Mounting Complete With All Accessories.Make- Kheraj Or As Equivalent 24 Supply, Install, Test And Commissioning Of Out-Door Type Sheet Metal Enclosure 3.00 Mm Thick Crca Sheet, Cpri Approved, Double Door Totally Enclosed, Weather, Dust And Vermin Proof As Per Iswith Front And Rearopening, Suitable Locking Arrangement, Top With Sloping Canopy Having Following:- ( A ) Mcb Tpn 32 Amp Rating Breaking Capacity 10 Ka - 01 No. ( Incoming ) , ( B ) Outgoing 32 A Mcb Sp-04 Nos With Breaking Capacity 10 Ka. 25 Supply And Laying Cable Xlpe Insulated Screened Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 16 Sqmm 3 Core, Completeall As Specified And As Directed. 26 Supply And Laying Cable Xlpe Insulated Screened Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 4 Sqmm 3 Core, Complete All As Specified And As Directed. 27 M&L For Laying Of Hdpe Pipe 50 Mm Dia Suitable For Pn10 Pressure Along With Connected Accessories For Cable / Ofc Protection, Complete All As Specified And As Directed By Engr-In-Charge . 28 Material And Labour Forsub Main Wiring With 3 Run Of 4 Sqmm Pvc Insulated Unsheathed Stranded Copper Conductor Frls-694 1100V Grade Concealed Wiring On Wall ( Including All The Accessories Like Clamp, Nut Bolt Etc. ) And Surface Wiring On Ceilingand Inclusive Non Metallic Conduit Med Grade Isi Marked ( Not Less Than 20Mm Dia ) Inclusive One Run Of Earth Pvc Insulated Single Core Unsheathed Stranded Copper Conductor Of Size 4 Sqmm, Complete All As Specified And Directed By Engineer In Charge. 29 S&F In Replacement Of Piano Type Bell Push Switch One Way, Sp, Flush Type, 5 / 6 Amps, 230 Volts Ac, 50 Hz, Complete All As Specified And Directed By Engineer In Charge. 30 Supply And Fix In Replacement Cablofil Wire Meshedstainless Steel ( Ss304 ) Cable Tray 54Mm ( H ) X 65 Mm ( W ) Complete With Nuts Bolts Washers ( Gi ) And All Accessories For Mounting And Supporting The Cable Tray System, Along With Vertical Bends. Make- Legrand / Schneider Or As Equivalent

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-11-2023
2 16-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-11-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 13700.0 /-
Tender Value
INR 6.85 Lakhs /-

BOQ Items

Name of Work: PROVN OF WORKS SERVICES FOR SDR AND CRASH BELL AT NEW ATC AT 8 FBSU AF STN AWANTIPUR
Sl. No. Item Description
1Supply and install hi wall split type Air Conditioner inverter type units indoor/outdoor unit complete with heating and cooling function with cordless remote control unit and with in built air ioniser and Plasma filter for better air quality with 4 star rating of capacity 1.5 TR split unit air conditioner electric driven single phase copper condensor, complete all as specified and directed.
2Supply and fix copper tubing 1/4 inches dia suitable for AC ducting complete with brazing and jointing, complete all as specified and directed.
3Supply and fix copper tubing 1/2 inches dia suitable for AC ducting complete with brazing and jointing, complete all as specified and directed.
4Supply and fix PVC rigid drain pipe 20 mm dia along with connecting accessories and fixing saddle at every 1m, complete all as specified and directed.
5Supply and fix copper cable 4 sqmm 3 core with necessary bottle lugs and connecting, complete all as specified and directed.
6M&L sub main wiring with multistranded FRLS copper conductor cable PVC sheathed in and including PVC casing capingwith two runs of 4.0 Sqmm and one run of 4.0 Sqmm FRLS copper conductor as earth wire and connected to earth dolly, completeall as specified and as directed.
7Suuply & fix Voltage Stabilizer 4 KVA capacity, copper wound suitable for input voltage 90 V to 270 V & output voltage stabilized 220 V, copper wound single phase 50 Hz along with time delay relay along with LCD display complete with all mounting accessories, completeall as specified and as directed.
8S&F sheet metal enclosure double door type for DBs (when MCB to be used) 8 way 240 volts with 200 Amps rated busbar and neutral link, completeall as specified and as directed.
9S&F Single pole & neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and as directed
10S & F MCB " C" series single pole, 240 V5 to 32 breaking capacity 10 KA Amps, completeall as specified and as directed.
11S & F MCB " C" series single pole & neutral, 240 V 40 Amps breaking capacity 10 kA Amps, completeall as specified and as directed.
12M&L for Earthing complete with GI earth plate 600 x 600 x 6 mm thick buried directly in ground (earth pit not less that 2.25mtr deep below ground level ) with top edge of the plate not less than 1.5mr below normal ground levelconnected to galvanised earth lead wire 4.0mm by means of brazing after tighten by bolts, nuts, check nuts and washersfrom earth pit to test point with protection GI pipe of size 25 mm dia light grade with watering pipe 20 mm diaand providing masonry enclosureearth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil, completeall as specified and as directed. Note: GI wire included in the quoted rate from earth pit to test point
13Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core, completeall as specified and as directed.
14Supply and fix Servo controlled Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type, suitable for unbalanced type load & designed for input variation between 360 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 1 x 25 KVA alongwith protection for short circuit/ overload high low voltage cut off by pass arrangement in case of emergency with efficiency more than 95% along with single phase sequence change phase fail protection, completeall as specified and as directed.
15Supply, installation, testing & commisioning in replacement of factory made (CPRI test certified manufacturer) LT feeder pillar box of minimum size 40cm (Height) x 30cm (Width) x 30 cm (Depth), outdoor type, floor mounted, double door, cubical compartmentalized type suitable for 415 volts, 3 phase, 4 wire, 50 Hz supply system all as specified and directed having busbar chamber with insulated aluminium busbar 200 Amps rating (100% neutral) installed on porcelain insulators. The panel shall be dust and vermin proof made of 3 mm (outer) & 2 mm (inner compartment door) CRCA sheet duly powder coated, panel mounted on angle iron 40x40x6 mm frame having 4 Nos legs 45 cm long of 40x40x6 mm angle iron, 15 cm grouted in PCC of ratio 1:2:4 and 30 cm clear space front ground level. Front & back opening type with aprons for cable entry with locking arrangement including internal wiring with PVC insulated multistranded copper conductor cables of suitable size, thimbling and cable entry boxes with cable glands. The scope of the work also includes supply and fixing the following:- INCOMING:- (a)MCCB 63 Amps, 25 kA rupturing capacity, 4 pole, 415 volts, 50 Hz, Adjustable thermal Fixed magnetic release type - 01 No. (b ) Voltmeter digital type 0-500 Volts, flush type with 3 way rotary selector switch -01 No (c)Ammeter digital type 0-100 Amps, flush type with 3 way rotary selector switch and 3 Nos CTs of ratio 100/5 Amps - 01 No (d)Indicating lamp (LED type) RYB - 01 Set of three OUTGOING:- (a)MCBTPN 63 Amps, 25 kA rupturing capacity, 4 pole -03 No.
16M&L for Earthing complete with GI earth plate 600 x 600 x 6 mm thick buried directly in ground (earth pit not less that 2.25mtr deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground levelconnected to32x6 mm GI strip as earthing lead by means of brazing after tighten by bolts, nuts, check nuts and washersfrom earth pit to test point with protection GI pipe of size 50mm dia light grade and providing masonry enclosureincluding watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil, complete all as specified and as directed. Note: GI strip 7.5 mtr included in the quoted rate from earth pit to test point
17M&L for excavation in trenches in soft/loose soil not exceeding 1.5 m in depth and width and getting out, complete all as specified and as directed.
18M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and as directed.
19M&L for removal of excess soil from site n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, completeall as specified and as directed.
20M&L for sand cushioning (dry sand) to underground cable for cable protectionlaid in trenches / in existingcable ducts, complete all as specified and as directed. Note: For payment point of view, compacted thickness of sand shall be measured.
21M&L for brick laying with subclass "B" bricks well burnt, laid dry flat in trenches for protection of cable over LT cable, complete all as specified and as directed.
22Supply, install, testing & commissioning Horizontal Double Mounting Siren Single Phase 220/250 V 6000 RPM 0.5 HP 50Hz, AC including mounting complete with all accessories. Make- Kheraj or as Equivalent
23Supply, install, testing & commissioning electric gong call bell single phase 220 V, AC including mounting complete with all accessories.Make- Kheraj or as Equivalent
24Supply, install, test and commissioning of out-door type sheet metal enclosure 3.00 mm thick CRCA sheet, CPRI approved, double door totally enclosed, weather, dust and vermin proof as per ISwith front and rearopening, suitable locking arrangement, top with sloping canopy having following:-(a)MCB TPN 32 Amp rating breaking capacity 10 KA - 01 No. (incoming), (b) Outgoing 32 A MCB SP-04 Nos with breaking capacity 10 kA.
25Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 3 core, completeall as specified and as directed.
26Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 sqmm 3 core, complete all as specified and as directed.
27M&L for laying of HDPE pipe 50 mm dia suitable for PN10 pressure along with connected accessories for cable/OFC protection, complete all as specified and as directed by Engr-in-charge .
28Material and labour forsub main wiring with 3 run of 4 sqmm PVC insulated unsheathed stranded copper conductor FRLS-694 1100V grade concealed wiring on wall(including all the accessories like clamp, nut bolt etc.) and surface wiring on ceilingand inclusive non metallic conduit Med grade ISI marked (not less than 20mm dia) inclusive one run of earth PVC insulated single core unsheathed stranded copper conductor of size 4 sqmm, complete all as specified and directed by engineer in charge.
29S&F in replacement of piano type bell push switch one way, SP, flush type, 5/6 Amps, 230 volts AC, 50 Hz, complete all as specified and directed by engineer in charge.
30Supply and fix in replacement CABLOFIL wire meshedstainless steel (SS304) cable tray 54mm (h) x 65 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends. Make- Legrand/Schneider or as Equivalent
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail