Public Works Department-PWD has published Tender For Construction Of Kailashahar Dist Jail At Kailashahar, Unakoti District Tripura/ Sh: Constn Of100 Seated Prisoners Ward(Male), 25 Seated Prisoners Ward (Female), 10 Seated Prisoners Cell, Administrative Block, Office & Visitor Room, Guard Room,. Submission Date for this Tender is 14-11-2023. Electrical Maintenance Tenders in Unakoti Tripura. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type switch including connection etc as required:-(As per TSR 2021,sl no.101) |
2 | Short Point :- |
3 | Medium Point :- |
4 | Long Point :- |
5 | Wiring for 2 way controlling lightpoint with 3 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type 2 way switch including connection etc as required:-(As per TSR-2021, Sl-102) |
6 | Short Point :- |
7 | Providing and fixing of 3 pin 5/6 amps plug point withpianotype 5/6ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required.( As per TSR 2021 Sl. 103) |
8 | Providing and fixing of 3/6 pin15/16 amps plug point withpianotype 15/16ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required.( As per TSR 2021 Sl. 104) |
9 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.( As per TSR 2021 Sl. 205) |
10 | 2x1.5 sq.mm: |
11 | 2x2.5 sq.mm: |
12 | 2x4 sq.mm: |
13 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required. ( As per TSR 2021 Sl. 503) |
14 | 1x1.5 sq.mm: |
15 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12"x 12" having locking arrangement including CC work, holes on earth pipe etc. as required.( As per TSR 2021 Sl. 701) |
16 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. ( As per TSR 2021 Sl. 702) |
17 | Providingearthing systemwith maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminalsize 32mmx 6mm including accessories with masonry enclosure of CIcover plate size 12"x 12" having locking arrangement including CC works etc as required.( As per TSR 2021 Sl. 717) |
18 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required.( As per TSR 2021 Sl. 706) |
19 | Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copperwire on surface or inexisting G.I / PVC / Polythene pipe for loop earthing as required. ( As per TSR 2021 Sl. 707) |
20 | Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required.( As per TSR 2021 Sl. 602) |
21 | 19/20 mm dia |
22 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick i/c accessories and providing masonry enclosure withCIcover plate Size 12"x 12" having locking arrangement, alongwith20 mm dia (medium gauge) watering pipe including CC work etc as required. ( As per TSR 2021 Sl. 704) |
23 | Extra for using salt (12 kg) and charcoal (96kg) for plate earth electrode as required. ( As per TSR 2021 Sl. 705) |
24 | Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. ( As per TSR 2021 Sl. 712) |
25 | Supply and fixing of 32mm x 6 mm GI strip on walls/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. ( As per TSR 2021 Sl. 713) |
26 | Supply and fixing of the following sizes GIprongwith necessary nuts & bolts etc as required grouted on roof for Lightning protection.( As per TSR 2021 Sl. 713) |
27 | G.I Prong 450 mm long |
28 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required.( As per TSR 2021 Sl.1202) |
29 | 32 amps 240 volts DP main switch (rewireable) |
30 | Supplying and installation of change over switch of following ratings with enclosure including necessary connection etc. as required.( As per TSR 2021 Sl.1204) |
31 | 160 amps FP on load change over switch (Front handle with enclosure) |
32 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required.( As per TSR 2021 Sl.1208) |
33 | 4 way SPN MCB DB (double door) |
34 | (2+4) / 6way SPN MCB DB (double door) |
35 | (2+6) / 8way SPN MCB DB (double door) |
36 | (2+10) / 12way SPN MCB DB (double door) |
37 | 4way horizontal TPN MCB DB (Double door) |
38 | 6way horizontal TPN MCB DB (Double door) |
39 | 12way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door) |
40 | 4 way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door) |
41 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required.( As per TSR 2021 Sl.1215) |
42 | 6 to 32 amps SP MCB |
43 | 6 to 32 amps DP MCB |
44 | 40/50/63 amps TP MCB |
45 | 40/50/63 amps TPN MCB |
46 | Supplying & installation of Surge Protection Device (SPD) of following ratings in the existing Panels/MCB DBs including necessay connections etc as required.( As per TSR 2021 Sl.1216) |
47 | Surge Protection Device (SPD, withdrawable) (Type-2) with Imax 70 KA (3P+N). |
48 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings)( As per TSR 2021 Sl.1219) |
49 | 125 amps FP MCCB, Breakingcapacity 25KA (Thermal Magnetic) |
50 | Supplying and fixing of following luminaries complete withnecessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours)( As per TSR 2021 Sl.1001) |
51 | Box type single FTL fittings of CRCA steel sheet housing complete with 36/40 W FTL,electronic ballast and high quality reflector cover. |
52 | Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp) |
53 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc.as required (with 50000 burning hours and minimum lumen output of 100 lm/watt)( As per TSR 2021 Sl.1101) |
54 | Surface mounted integrated 10 watt LED batten with polycarbonate diffuser. |
55 | Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser. |
56 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt)( As per TSR 2021 Sl.1102) |
57 | 6 watt/10 watt LED Bulkhead light with high quality polycarbonate diffuser (IP 65) |
58 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required.( As per TSR 2021 Sl.1103) |
59 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink |
60 | Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR)(ISI marked, BEE 1star/minimum service value 4.0 m3/min/W) ( As per TSR 2021 Sl.802) |
61 | Supplying & installation of 400 mm sweep AC wall mounting fan with plastic blade including connection etc as required. ( As per TSR 2021 Sl.811) |
62 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required. ( As per TSR 2021 Sl.817) |
63 | Supplying & installation of 300 mm sweep 900 rpm metalic body exhaust fan including connection etc as required (ISI marked)( As per TSR 2021 Sl.818) |
64 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required. ( As per TSR 2021 Sl.821) |
65 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required. ( As per TSR 2021 Sl.831) |
66 | Supplying and fixing of Guarder for protection of 1200/ 1400 mm sweep ceiling fan made with MS flat, 6 SWG GI wire i/c painting etc as required.( As per TSR 2021 Sl.828) |
67 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 noslegs (25mmx25mmx5mm MS angle20 cm long) finishedwith red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required.( As per TSR 2021 Sl. 1502) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy